200 resultados para Astronomical Instrumentation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The basal sliding surfaces in large rockslides are often composed of several surfaces and possess a complex geometry. The exact morphology and location in three dimensions of the sliding surface remains generally unknown, in spite of extensive field and subsurface investigations, such as those at the Åknes rockslide (western Norway). This knowledge is crucial for volume estimations, failure mechanisms, and numerical slope stability modeling. This paper focuses on the geomorphologic characterization of the basal sliding surface of a postglacial rockslide scar in the vicinity of Åknes. This scar displays a stepped basal sliding surface formed by dip slopes of the gneiss foliation linked together by steeply dipping fractures. A detailed characterization of the rockslide scar by means of high-resolution digital elevation models permits statistical parameters of dip angle, spacing, persistence, and roughness of foliation surfaces and step fractures to be obtained. The characteristics are used for stochastic simulations of stepped basal sliding surfaces at the Åknes rockslide. These findings are compared with previous models based on geophysical investigations. This study discusses the investigation of rockslide scars and rock outcrops for a better understanding of potential rockslides. This work identifies possible basal sliding surface locations, which is a valuable input for volume estimates, design and location of monitoring instrumentation, and numerical slope stability modeling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RATIONALE: AICAR (5-aminoimidazole-4-carboxamide 1β-D-ribofuranoside) is prohibited in sport according to rules established by the World Anti-Doping Agency. Doping control laboratories identify samples where AICAR abuse is suspected by measuring its urinary concentration and comparing the observed level with naturally occurring concentrations. As the inter-individual variance of urinary AICAR concentrations is large, this approach requires a complementary method to unambiguously prove the exogenous origin of AICAR. Therefore, a method for the determination of carbon isotope ratios (CIRs) of urinary AICAR has been developed and validated. METHODS: Concentrated urine samples were fractionated by means of liquid chromatography for analyte cleanup. Derivatization of AICAR yielding the trimethylsilylated analog was necessary to enable CIR determinations by gas chromatography/combustion/isotope ratio mass spectrometry. The method was tested for its repeatability and stability over time and a linear mixing model was applied to test for possible isotopic discrimination. A reference population of n = 63 males and females was investigated to calculate appropriate reference limits to differentiate endogenous from exogenous urinary AICAR. These limits were tested by an AICAR elimination study. RESULTS: The developed method fulfills all the requirements for adequate sports drug testing and was found to be fit for purpose. The investigated reference population showed a larger variability in the CIR of AICAR than of the endogenous steroids. Nevertheless, the calculated thresholds for differences between AICAR and endogenous steroids can be applied straightforwardly to evaluate suspicious doping control samples with the same statistical confidence as established e.g. for testosterone misuse. These thresholds enabled the detection of a single oral AICAR administration for more than 40 h. CONCLUSIONS: Determination of thee CIRs is the method of choice to distinguish between an endogenous and an exogenous source of urinary AICAR. The developed method will enable investigations into doping control samples with elevated urinary concentrations of AICAR and clearly differentiate between naturally produced/elevated and illicitly administered AICAR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dislocated compound fractures of the proximal humerus are often difficult to treat. The choice of treatment influences the final functional result. From 1984-1991 108 patients with dislocated compound fractures of the proximal humerus were operated with a T-plate osteosynthesis, retrospectively examined and classified according to the Neer-Classification. At an average follow up time of 5 years 72 patients had a clinical and radiological examination. 68% of these patients with 3-fragment fractures and 80% with 4-fragment fractures showed a modest to unsatisfactory result caused by fracture biology, imprecise fracture reduction or poor surgical procedure. Incorrect position of T-plates and inadequate material were distinguishable. The T-plate which was widely used in the late eighties for internal fixation has to be considered a failure for these particular types of fractures and should be limited for Collum chirurgicum fractures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances in signal analysis have engendered EEG with the status of a true brain mapping and brain imaging method capable of providing spatio-temporal information regarding brain (dys)function. Because of the increasing interest in the temporal dynamics of brain networks, and because of the straightforward compatibility of the EEG with other brain imaging techniques, EEG is increasingly used in the neuroimaging community. However, the full capability of EEG is highly underestimated. Many combined EEG-fMRI studies use the EEG only as a spike-counter or an oscilloscope. Many cognitive and clinical EEG studies use the EEG still in its traditional way and analyze grapho-elements at certain electrodes and latencies. We here show that this way of using the EEG is not only dangerous because it leads to misinterpretations, but it is also largely ignoring the spatial aspects of the signals. In fact, EEG primarily measures the electric potential field at the scalp surface in the same way as MEG measures the magnetic field. By properly sampling and correctly analyzing this electric field, EEG can provide reliable information about the neuronal activity in the brain and the temporal dynamics of this activity in the millisecond range. This review explains some of these analysis methods and illustrates their potential in clinical and experimental applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study is to create a standard test to approve the efficacy of a surgical sealant. An industrial test, the bulge-and-blister test, which is very convenient for measuring adhesion energy, is applied to the surgical field to quantify adhesion of bioadhesives. METHODS: Samples were composed of two circular layers of equine pericardium glued by the surgical sealant studied. The sample was fixed to a support with an industrial glue. The support and the bottom layer were perforated in the centre to allow injection of pressurised water. Water was progressively introduced through the hole in the support and the bottom layer to create a blister with constant radius, increasing height and internal pressure during this first step. At a critical pressure, delamination started, the radius and height of the blister increased and the pressure decreased. At this point, the adhesion energy could be determined. The experimental parameters were measured with a pressure sensor and an optical profilometry device for deflection. RESULTS: Adhesion testing was carried out in eight paired equine pericardium samples bonded with a Dermabond cyanoacrylate glue. The average value of the practical adhesion energy is 2.3 Jm(-2) with a standard deviation of 1.5 Jm(-2). CONCLUSION: Application of the bulge-and-blister test to the surgical field was achieved and allowed a quantification of adhesion of a surgical glue. Such information is essential to compare the different surgical glues presently available. The study of the impact of bonding conditions such as pressure, hygrometry or setting conditions will provide a better understanding of the characteristics of adhesion in the surgical field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acute massive pulmonary embolism (PE) is a life-threatening event. Before the era of cardiopulmonary bypass, acute pulmonary embolectomy had been historically attempted in patients with severe hemodynamic compromise. The Klippel-Trenaunay syndrome (KTS) represents a significant life-long risk for major thromboembolic events. We present two young patients with Klippel-Trenaunay syndrome who survived surgical embolectomy after massive PE and cardiopulmonary resuscitation, with good postoperative recovery. Even though the role of surgical embolectomy in massive PE is not clearly defined, with current technology it can be life saving and can lead to a complete recovery, especially in young patients as described in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RAPPORT DE SYNTHÈSE : Chez les patients présentant une pathologie de la colonne cervicale, l'instrumentation des voies aériennes peut s'avérer délicate. En effet, l'impossibilité d'effectuer une extension de la nuque afin d'aligner correctement l'axe oro-pharyngo-trachéal, ainsi que l'ouverture de bouche limitée par la présence d'une minerve cervicale, rendent la laryngoscopie standard extrêmement difficile. Le but de cette étude est de démontrer que l'intubation oro-trachéale avec une minerve cervicale semi-rigide est possible à l'aide d'un vidéolaryngoscope récemment développé, le GlideScope®. Celui-ci est formé d'une lame courbe présentant une angulation accentuée à 60° à partir de son milieu, avec une petite caméra haute résolution et une source lumineuse enchâssées dans la partie inférieure au point d'inflexion. Différents travaux ont montré les avantages du GlideScope® par rapport à la lame de Macintosh standard "pour l'instrumentation des voies aériennes de routine ou en situation difficile. Après acceptation par la Commission d'Ethique, 50 patients, adultes consentants et programmés pour une intervention chirurgicale élective nécessitant une anesthésie générale ont été inclus dans cette étude. Malgré la présence d'une minerve cervicale semi-rigide Philadelphia® Patriot correctement positionnée et la tête fixée à la table d'opération, tous les patients ont pu être intubés a l'aide du GlideScope®. Aucune complication n'a été documentée pendant la procédure ou en post-opératoire. De plus, nous avons démontré que dans cette situation la visualisation des structures laryngées est significativement améliorée grâce au GlideScope®, par rapport à la lame de Macintosh utilisée lors de toute intubation standard. En conclusion, l'intubation oro-trachéale chez les patients ayant une minerve cervicale et la tête fixée est possible à l'aide du GlideScope®. La meilleure façon de sécuriser les voies aériennes chez les patients présentant une instabilité de la colonne cervicale est un sujet fortement débattu. L'utilisation du GlideScope® pourrait s'avérer une alternative intéressante, en particulier dans les situations d'urgence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anterior spinal infection (prevertebral abscess and/or discitis) after posterior instrumentation for vertebral fractures is a challenging complication, since a new implant may become necessary anteriorly, in a septic environment. Generally accepted management guidelines are yet to be established. The authors present a case of posterior instrumentation for fractures of T12 and L1, complicated after 9 months with an anterior infection (prevertebral abscess and discitis) with extended-spectrum beta-lactamase (ESBL) producing Escherichia coli (E. coli). This case is unique in that the multi-resistant organism was isolated only after the second stage of infection treatment, which consisted of anterior débridement and anterior implantation of titanium cages and rods. In this particular case, infection was controlled despite implantation of multiple cages, screws and rods, and fusion was achieved, by means of intravenous antibiotic treatment for 12 months. At the latest follow-up, 24 months post surgery, there was no evidence of infection. This problem case may be helpful for surgeons confronted with spinal deformities secondary to infections with multi-resistant organisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le présent cahier documente les différents programmes informatiques nécessaires à l'adaptation suisse des DRG.