119 resultados para Air Pollutants


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Previous studies have demonstrated that poultry-house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers, on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at 3 different stages of the birds' growth; Samples of air taken from within the breathing zones of individual poultry-house employees as they caught the chickens ready to be transported for slaughter, were also analysed. Quantitative PCR (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 31 ± 4.7 mg/m3, and endotoxin concentration was 11'080 ± 3436 UE/m3 air, more than ten-fold higher than the Swiss occupational recommended value (1000 UE/m3). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively reaching values of 72 (± 11) x107 cells/m3 air and 70 (± 16) x106/m3 air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Une veille bibliographique est organisée depuis 2005 sur la surveillance biologique aux produits chimiques en milieu de travail (SBEPC MT). Elle a été mise en place par le réseau francophone multidisciplinaire, composé de l'INRS (France), l'IRSST (Québec) et l'UCL (Belgique). Cet article dresse le bilan de l'information récoltée et analysée, de 2009 à 2012, au travers de 435 articles sélectionnés. Plusieurs thèmes d'intérêt ou d'actualités font l'objet d'une analyse plus approfondie, dont notamment les pesticides, les hydrocarbures aromatiques, le benzène, le mangannèse, la variabilité biologique, les dosages cutanés et frottis de surface, les dosages dans l'air expiré ou encore la spectrométrie de masse.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dans cette première de quatre parties, un réseau francophone multidisciplinaire présente les principaux résultats d'une veille bibliographique sur la surveillance biologique de l'exposition aux produits chimiques en milieu de travail.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Previous studies on childhood cancer and nuclear power plants (NPPs) produced conflicting results. We used a cohort approach to examine whether residence near NPPs was associated with leukaemia or any childhood cancer in Switzerland. METHODS: We computed person-years at risk for children aged 0-15 years born in Switzerland from 1985 to 2009, based on the Swiss censuses 1990 and 2000 and identified cancer cases from the Swiss Childhood Cancer Registry. We geo-coded place of residence at birth and calculated incidence rate ratios (IRRs) with 95% confidence intervals (CIs) comparing the risk of cancer in children born <5&#8201;km, 5-10&#8201;km and 10-15&#8201;km from the nearest NPP with children born >15&#8201;km away, using Poisson regression models. RESULTS: We included 2925 children diagnosed with cancer during 21&#8201;117&#8201;524 person-years of follow-up; 953 (32.6%) had leukaemia. Eight and 12 children diagnosed with leukaemia at ages 0-4 and 0-15 years, and 18 and 31 children diagnosed with any cancer were born <5&#8201;km from a NPP. Compared with children born >15&#8201;km away, the IRRs (95% CI) for leukaemia in 0-4 and 0-15 year olds were 1.20 (0.60-2.41) and 1.05 (0.60-1.86), respectively. For any cancer, corresponding IRRs were 0.97 (0.61-1.54) and 0.89 (0.63-1.27). There was no evidence of a dose-response relationship with distance (P&#8201;>&#8201;0.30). Results were similar for residence at diagnosis and at birth, and when adjusted for potential confounders. Results from sensitivity analyses were consistent with main results. CONCLUSIONS: This nationwide cohort study found little evidence of an association between residence near NPPs and the risk of leukaemia or any childhood cancer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Short-term exposure to ambient particulate matter with aerodynamic diameters<10 µm were found to be positively associated with blood pressure. Yet, little information exists regarding the association between particles and circadian rhythm of blood pressure. Hence, we analyzed the association of exposure to particulate matter with aerodynamic diameters<10 µm on the day of examination and &#8804;7 days before with ambulatory blood pressure and with sodium excretion in 359 adults from the general population using multiple linear regression. After controlling for potential confounders, a 10-µg/m3 increase in particulate matter with aerodynamic diameters<10 µm levels was associated with nighttime systolic blood pressure (&#946;=1.32 mm Hg 95% CI, 0.06-2.58 mm Hg at lag 0; P=0.04), nighttime diastolic blood pressure (0.72 mm Hg 95% CI, 0.03-1.42 mm Hg at lag 2; P=0.04), nocturnal systolic blood pressure dipping (-0.96 mm Hg 95% CI, -1.89 to -0.03 mm Hg at lag 0; P=0.044), and daytime urinary sodium excretion (-0.05 log-mmol/min 95% CI, -0.10 to -0.01 log-mmol/min at lag 0; P=0.027) but not with nighttime sodium excretion. The associations with blood pressure rapidly diminished with increasing lag days, and the associations with daytime sodium excretion were maximal with particulate matter with aerodynamic diameters<10 µm in exposures 2 to 5 days before. The associations of short-term increases in particulate matter with aerodynamic diameters<10 µm with higher nighttime blood pressure and blunted systolic blood pressure dipping were preceded by associations with reduced ability of the kidney to excrete sodium during daytime. The underlying mechanism linking air pollution to increased cardiovascular risk may include disturbed circadian rhythms of renal sodium handling and blood pressure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cet article est la seconde partie d'une série de quatre consacrée aux résultats d'une veille bibliographique sur la surveillance biologique de l'exposition aux produits chimiques en milieu de travail (SBEPC MT). Alors que la précédente partie présentait les objectifs et l'organisation de la veille, cette partie ainsi que la partie 3 vont donc présenter une vue d'ensemble de la base de données en fonction de l'indexation des articles analysés par différents mots clés.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To explore the association of short-term exposure to particulate matter with aerodynamic diameters less than 10&#8202;&#956;m (PM10) with pulse pressure, SBP, and DBP taking outdoor temperature into account in two large population-based studies in Switzerland. METHODS: We used data from the Bus Santé study including 5605 adults in Geneva and the CoLaus study including 6183 adults in Lausanne. PM10 and meteorological data were measured from fixed monitoring stations. We analyzed the association of short-term exposure to PM10 (on the day of examination visit and up to 7 days before) with pulse pressure, SBP, and DBP by linear regression, controlling for potential confounders and effect modifiers. RESULTS: Average PM10 levels were 22.4&#8202;&#956;g/m in Geneva and 31.7&#8202;&#956;g/m in Lausanne. In adjusted models, for each 10&#8202;&#956;g/m increase in 7-day PM10 average, pulse pressure and SBP increased by 0.583 (95% confidence interval, 0.296-0.870) mmHg and 0.490 (0.056-0.925) mmHg in Geneva, and 0.183 (0.017-0.348) mmHg and 0.036 (0.042-0.561) mmHg in Lausanne, respectively. Stronger associations of pulse pressure and SBP with PM10 were observed when outdoor temperature was above 5°C. CONCLUSION: Positive associations of pulse pressure and SBP with short-term exposure to PM10 were found and replicated in the Swiss adult population. Our results suggest that even low levels of air pollution may substantially impact cardiovascular risk in the general population.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We analyzed 42 models from 14 brands of refill liquids for e-cigarettes for the presence of micro-organisms, diethylene glycol, ethylene glycol, hydrocarbons, ethanol, aldehydes, tobacco-specific nitrosamines, and solvents. All the liquids under scrutiny complied with norms for the absence of yeast, mold, aerobic microbes, Staphylococcus aureus, and Pseudomonas aeruginosa. Diethylene glycol, ethylene glycol and ethanol were detected, but remained within limits authorized for food and pharmaceutical products. Terpenic compounds and aldehydes were found in the products, in particular formaldehyde and acrolein. No sample contained nitrosamines at levels above the limit of detection (1 μg/g). Residual solvents such as 1,3-butadiene, cyclohexane and acetone, to name a few, were found in some products. None of the products under scrutiny were totally exempt of potentially toxic compounds. However, for products other than nicotine, the oral acute toxicity of the e-liquids tested seems to be of minor concern. However, a minority of liquids, especially those with flavorings, showed particularly high ranges of chemicals, causing concerns about their potential toxicity in case of chronic oral exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Voici la quatrième et dernière partie des résultats d'une veille bibliographique sur la surveillance biologique de l'exposition aux produits chimiques en milieu de travail (SBEPCMT) mise en place par un réseau francophone multidisciplinaire.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: According to estimations around 230 people die as a result of radon exposure in Switzerland. This public health concern makes reliable indoor radon prediction and mapping methods necessary in order to improve risk communication to the public. The aim of this study was to develop an automated method to classify lithological units according to their radon characteristics and to develop mapping and predictive tools in order to improve local radon prediction. METHOD: About 240 000 indoor radon concentration (IRC) measurements in about 150 000 buildings were available for our analysis. The automated classification of lithological units was based on k-medoids clustering via pair-wise Kolmogorov distances between IRC distributions of lithological units. For IRC mapping and prediction we used random forests and Bayesian additive regression trees (BART). RESULTS: The automated classification groups lithological units well in terms of their IRC characteristics. Especially the IRC differences in metamorphic rocks like gneiss are well revealed by this method. The maps produced by random forests soundly represent the regional difference of IRCs in Switzerland and improve the spatial detail compared to existing approaches. We could explain 33% of the variations in IRC data with random forests. Additionally, the influence of a variable evaluated by random forests shows that building characteristics are less important predictors for IRCs than spatial/geological influences. BART could explain 29% of IRC variability and produced maps that indicate the prediction uncertainty. CONCLUSION: Ensemble regression trees are a powerful tool to model and understand the multidimensional influences on IRCs. Automatic clustering of lithological units complements this method by facilitating the interpretation of radon properties of rock types. This study provides an important element for radon risk communication. Future approaches should consider taking into account further variables like soil gas radon measurements as well as more detailed geological information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Exposure to environmental tobacco smoke (ETS) is a major environmental risk factor. Indoor contaminants come from a variety of sources, which can include inadequate ventilation, volatile organic compounds (VOCs), biological agents, combustion products, and ETS. Because ETS is one of the most frequent causes of IAQ complaints as well as the high mortality of passive smoking, in June 2004 the University of Geneva made the decision to ban smoking inside the so called "Uni-Mail" building, the biggest Swiss University human science building of recent construction, and the ordinance was applied beginning in October 2004. This report presents the finding related to the IAQ of the "Uni-Mail" building before and after smoking bans using nicotine, suspended dust, condensate and PAHs level in air as tracers to perform an assessment of passive tobacco exposure for non-smokers inside the building. Methods: Respirable particles (RSP) A real time aerosol monitor (model DataRAM)was place at sampling post 1, level ground floor. Condensate It consists in extracting any organic matter taken on the glass fibre filters by MeOH, and then measuring the total absorbent of the MeOH extract to the UV wavelength of 447 nm. Nicotine Nicotine was taken by means of cartridges containing of XAD-4 to the fixed flow of 0.5 L/min. The analytical method used for the determination of nicotine is based on gas chromatography with Nitrogen selective detector GC-NPD. Results: Figure 1 shows the box plot density display of 3 parameters before and after smoking bans for all 7 sampling posts: dust, condensate and nicotine in air in &#956;g/m3. Conclusion: Before the smoking ban, the level of the concentrations of respirable particles (RSP) is raised more, average of the day 320 &#956;g/m3, with peaks of more than 1000 &#956;g/m3, compared with the values of the surrounding air between 22 and 30 &#956;g/m3. The nicotine level is definitely more important (average 5.53 &#956;g/m3, field 1.5 to 17.9 &#956;g/m3). Once the smoking bans inside the building were applied, one notes a clear improvement in terms of concentrations of pollutants. For dust, the concentration fell by 3 times (average: 130 &#956;g/m3, range: 40 to 160 &#956;g/m3) and that of nicotine by 10 times (average: 0.53 &#956;g/m3, range: 0 to 1.69 &#956;g/m3) compared to that found before smoking bans. The outdoor air RSP concentration was 22 &#956;g/m3 or 10 times lower. Nicotine seems to be the best tracer for ETS free of interference, independent of location or season.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neglecting health effects from indoor pollutant emissions and exposure, as currently done in Life Cycle Assessment (LCA), may result in product or process optimizations at the expense of workers' or consumers' health. To close this gap, methods for considering indoor exposure to chemicals are needed to complement the methods for outdoor human exposure assessment already in use. This paper summarizes the work of an international expert group on the integration of human indoor and outdoor exposure in LCA, within the UNEP/ SETAC Life Cycle Initiative. A new methodological framework is proposed for a general procedure to include human-health effects from indoor exposure in LCA. Exposure models from occupational hygiene and household indoor air quality studies and practices are critically reviewed and recommendations are provided on the appropriateness of various model alternatives in the context of LCA. A single-compartment box model is recommended for use as a default in LCA, enabling one to screen occupational and household exposures consistent with the existing models to assess outdoor emission in a multimedia environment. An initial set of model parameter values was collected. The comparison between indoor and outdoor human exposure per unit of emission shows that for many pollutants, intake per unit of indoor emission may be several orders of magnitude higher than for outdoor emissions. It is concluded that indoor exposure should be routinely addressed within LCA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In European countries and North America, people spend 80 to 90% of time inside buildings and thus breathe indoor air. In Switzerland, special attention has been devoted to the 16 stations of the national network of observation of atmospheric pollutants (NABEL). The results indicate a reduction in outdoor pollution over the last ten years. With such a decrease in pollution over these ten years the question becomes: how can we explain an increase of diseases? Indoor pollution can be the cause. Indoor contaminants that may create indoor air quality (IAQ) problems come from a variety of sources. These can include inadequate ventilation, temperature and humidity dysfunction, and volatile organic compounds (VOCs). The health effects from these contaminants are varied and can range from discomfort, irritation and respiratory diseases to cancer. Among such contaminants, environmental tobacco smoke (ETS) could be considered the most important in terms of both health effects and engineering controls of ventilation. To perform indoor pollution monitoring, several selected ETS tracers can be used including carbon monoxide (CO), carbon dioxide (CO2), respirable particles (RSP), condensate, nicotine, polycyclic aromatic hydrocarbons (PAHs), nitrosamines, etc. In this paper, some examples are presented of IAQ problems that have occurred following the renewal of buildings and energy saving concerns. Using industrial hygiene sampling techniques and focussing on selected priority pollutants used as tracers, various problems have been identified and solutions proposed. [Author]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.