100 resultados para 3rd ventricle


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Van der Woude syndrome (VWS), caused by dominant IRF6 mutation, is the most common cleft syndrome. In 15% of the patients, lip pits are absent and the phenotype mimics isolated clefts. Therefore, we hypothesized that some of the families classified as having non-syndromic inherited cleft lip and palate could have an IRF6 mutation. We screened in total 170 patients with cleft lip with or without cleft palate (CL/P): 75 were syndromic and 95 were a priori part of multiplex non-syndromic families. A mutation was identified in 62.7 and 3.3% of the patients, respectively. In one of the 95 a priori non-syndromic families with an autosomal dominant inheritance (family B), new insights into the family history revealed the presence, at birth, of lower lip pits in two members and the diagnosis was revised as VWS. A novel lower lip sign was observed in one individual in this family. Interestingly, a similar lower lip sign was also observed in one individual from a 2nd family (family A). This consists of 2 nodules below the lower lip on the external side. In a 3rd multiplex family (family C), a de novo mutation was identified in an a priori non-syndromic CL/P patient. Re-examination after mutation screening revealed the presence of a tiny pit-looking lesion on the inner side of the lower lip leading to a revised diagnosis of VWS. On the basis of this data, we conclude that IRF6 should be screened when any doubt rises about the normality of the lower lip and also if a non-syndromic cleft lip patient (with or without cleft palate) has a family history suggestive of autosomal dominant inheritance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To produce age-related normograms for serum antimullerian hormone (AMH) level in infertile women without polycystic ovaries (non-PCO).Design: Retrospective cohort analysis.Setting: Fifteen academic reproductive centers.Patient(s): A total of 3,871 infertile women.Intervention(s): Blood sampling for AMH level.Main Outcome Measure(s): Serum AMH levels and correlation between age and different percentiles of AMH.Result(s): Age-related normograms for the 3rd, 10th, 25th, 50th, 75th, 90th, and 97th percentiles of AMH were produced. We found that the curves of AMH by age for the 3rd to 50th percentiles fit the model and appearance of linear relation, whereas the curves of >75th percentiles fit cubic relation. There were significant differences in AMH and FSH levels and in antral follicle count (AFC) among women aged 24-33 years, 34-38 years, and >= 39 years. Multivariate stepwise linear regression analysis of FSH, age, AFC, and the type of AMH kit as predictors of AMH level shows that all variables are independently associated with AMH level, in the following order: AFC, FSH, type of AMH kit, and age.Conclusion(s): Age-related normograms in non-PCO infertile women for the 3rd to 97th percentiles were produced. These normograms could provide a reference guide for the clinician to consult women with infertility. However, future validation with longitudinal data is still needed. (Fertil Steril (R) 2011; 95: 2359-63. (C) 2011 by American Society for Reproductive Medicine.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The way supervisors acknowledge specific contribution and efforts of their employees has an impact on occupational health and wellbeing. Acknowledgement is a protective factor when it is sufficiently provided. We carried out a study about occupational health in police officers with special emphasis on acknowledgment and reward. A questionnaire was sent to 1000 police officers and inspectors working for a cantonal administration in Switzerland. In total, 695 participants answered the questionnaire. We used the TST questionnaire (French version of the Langner's questionnaire on psychiatric symptoms) to identify cases characterized by potential mental health problems. Multiple choice items (5 modalities ranging from "not at all" to "tremendously") were used to measure acknowledgment. The score for psychiatric symptoms was high (TST score >or= 9) for 86 police officers and inspectors for whom health might be at risk. Compared with police officers having low or medium scores for psychiatric symptoms (TST score < 9), police officers with high TST scores were more likely to report the lack of support and attention from the supervisors (odds ratio [OR] 3.2, 95% confidence interval [CI] 2.0 to 5.1) and the lack of acknowledgment by the hierarchy (OR 3.0, 95% CI 1.9 to 4.8). They were also more likely to mention that judicial authorities have a low consideration for police officers (OR 2.7, 95% CI 1.7 to 4.3) and that the public in general have a low appreciation of police officers (OR 1.8, 95% CI 1.2 to 2.9). Preserving mental health in occupations characterized by high emotional demand is challenging. Our results show that acknowledgment and mental health are associated. Further research should address a potential causal relation of acknowledgment on mental health in police officers and inspectors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In late-diagnosed transposition of the great arteries (TGA), the left ventricle (LV) involutes as it pumps against low resistance and needs retraining by applying a pulmonary artery band (PAB) in preparation for an arterial switch operation. We report our experience with a telemetrically adaptable band compared with classic banding. METHODS: Ten patients underwent retraining of the LV, 4 patients with an adaptable band and progressive weekly tightening of the band (group 1) and 6 patients with a traditional band (group 2). RESULTS: Mean weight and age at pulmonary band placement was 5.8 ± 2.36 kg and 11.7 ± 11.1 months for group 1 and 5.0 ± 2.3 kg and 6.4 ± 7.6 months for group 2. Time between palliation and switch procedure was 4.2 months in both groups. Group 1 showed an initial mean pulmonary gradient of 25.5 ± 4.43 mm Hg with a 5% closure of the device. The mean gradient increased with progressive closure to 63.5 ± 9.8 mm Hg at the time of the arterial switch operation. There were no reinterventions or deaths in this group. In group 2, the mean pulmonary gradient increased with growth from 49 ± 21.4 mm Hg to 68.4 ± 7.86 mm Hg at the time of the switch procedure. However, 4 of these patients required reoperations during retraining: 2 needed 1 reoperation and 2 needed 2 reoperations. Two patients died-1 after banding and 1 after the switch operation. CONCLUSIONS: Retraining of the LV by the adaptable device allows precise control of the tightening, avoids repetitive operations, and diminishes morbidity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A technique for fast imaging of regional myocardial function using a spiral acquisition in combination with strain-encoded (SENC) magnetic resonance imaging (MRI) is presented in this paper. This technique, which is termed fast-SENC, enables scan durations as short as a single heartbeat. A reduced field of view (FOV) without foldover artifacts was achieved by localized SENC, which selectively excited the region around the heart. The two images required for SENC imaging (low- and high-tuning) were acquired in an interleaved fashion throughout the cardiac cycle to further shorten the scan time. Regional circumferential contraction and longitudinal shortening of both the left ventricle (LV) and right ventricle (RV) were examined in long- and short-axis views, respectively. The in vivo results obtained from five human subjects and five infarcted dogs are presented. The results of the fast-SENC technique in a single heartbeat acquisition were comparable to those obtained by conventional SENC in a long acquisition time. Therefore, fast-SENC may prove useful for imaging during stress or arrhythmia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

French verb morphology has always been a major challenge for learners as well as teachers of French as a foreign language. Learning difficulties arise not only from the inherent complexity of the conjugation system itself, but mostly from the traditional description found in specialized books, grammars, etc. French spelling alone tends to complexify the actual oral verb morphology by more than 60%, thus hindering efficient learning. Following Dubois (1967), Csécsy (1968), Pouradier Duteil (1997), etc., I suggest an alternative approach, exclusively based on phonetic transcription, and starting with plural forms instead of singular ones (Mayer 1969). For more than 500 verbs of the 2nd and 3rd groups, this strategy allows learners to first memorize the present tense plural form e.g. /illiz/ (ils lisent, "they read") and take the stem's final consonant away to get the singular /illi/ (il lit, "he reads").

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to the most widely accepted Cattell-Horn-Carroll (CHC) model of intelligence measurement, each subtest score of the Wechsler Intelligence Scale for Adults (3rd ed.; WAIS-III) should reflect both 1st- and 2nd-order factors (i.e., 4 or 5 broad abilities and 1 general factor). To disentangle the contribution of each factor, we applied a Schmid-Leiman orthogonalization transformation (SLT) to the standardization data published in the French technical manual for the WAIS-III. Results showed that the general factor accounted for 63% of the common variance and that the specific contributions of the 1st-order factors were weak (4.7%-15.9%). We also addressed this issue by using confirmatory factor analysis. Results indicated that the bifactor model (with 1st-order group and general factors) better fit the data than did the traditional higher order structure. Models based on the CHC framework were also tested. Results indicated that a higher order CHC model showed a better fit than did the classical 4-factor model; however, the WAIS bifactor structure was the most adequate. We recommend that users do not discount the Full Scale IQ when interpreting the index scores of the WAIS-III because the general factor accounts for the bulk of the common variance in the French WAIS-III. The 4 index scores cannot be considered to reflect only broad ability because they include a strong contribution of the general factor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We previously established that exogenous adenosine (ADO) induces transient arrhythmias in the developing heart via the adenosine A1 receptor (A1AR) and downstream activation of NADPH oxidase/ERK and PLC/PKC pathways. Here, we investigated the mechanisms by which accumulation of endogenous ADO and its derived compound inosine (INO) in the interstitial compartment induce rhythm and conduction troubles. The validated model of the spontaneously beating heart obtained from 4-day-old chick embryos was used. Quantitative RT-PCR showed that enzymes involved in ADO and INO metabolism (CD39, CD73 and eADA) as well as equilibrative (ENT1, -3, -4) and concentrative (CNT3) nucleoside transporters were differentially expressed in atria, ventricle and outflow tract. Inactivation of ENTs by dipyridamole, 1) increased myocardial ADO level, 2) provoked atrial arrhythmias and atrio-ventricular blocks (AVB) in 70% of the hearts, 3) prolonged P wave and QT interval without altering contractility, and 4) increased ERK2 phosphorylation. Blockade of CD73-mediated phosphohydrolysis of AMP to ADO, MEK/ERK pathway inhibition or A1AR inhibition prevented these arrhythmias. Exposure to exogenous INO also caused atrial ectopy associated with AVB and ERK2 phosphorylation which were prevented by A1AR or A2AAR antagonists exclusively or by MEK/ERK inhibitor. Inhibition of ADA-mediated conversion of ADO to INO increased myocardial ADO and decreased INO as expected, but slightly augmented heart rate variability without provoking AVB. Thus, during cardiogenesis, disturbances of nucleosides metabolism and transport, can lead to interstitial accumulation of ADO and INO and provoke arrhythmias in an autocrine/paracrine manner through A1AR and A2AAR stimulation and ERK2 activation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies have shown that CD4+ CD25+ T cells belong to two functionally different T lymphocytes, i.e. regulatory T cells (Treg) or activated T cells (Tact), which can be distinguished based on the expression of CD45RO and IL-7R: Treg (FoxP3+) are CD45RO+ IL-7R- , whereas Tact (FoxP3- ) are CD45RO+ IL- 7R+. In order to determine if a CD4+ CD25+ CD45RO+ IL-7R+ activated T cell population might be identified in kidney transplant recipients, we studied 27 healthy subjects (HS) and 23 kidney recipients, of whom 17 had stable graft function under standard immunosuppression (IS), 5 had biopsy-proven chronic humoral rejection (CHR), and one was a stable "tolerant" patient who had discontinued IS for more than 2 years. Phenotypical analysis by flow cytometry and functional assays by MLR were performed. Overall, the Tact population was found to be significantly increased in 87% of the transplant recipients (mean: 18.8±10.1% of CD4+ CD25+ T cells) compared to HS (mean: 4.5±2.0%; P<0.0001). In the 5 patients with CHR, this Tact population was highly expanded (31.3±9.3%; P<0.0001), whereas it was comparable to HS in the "tolerant" recipient (4.7%). Intermediate levels (16.0±6.9%; P<0.0001) were found in the 17 stable recipients. In CHR, the proliferative capacity of the Tact population was found to be 5-fold higher when stimulated by irradiated donor PBMC as compared to a stimulation by irradiated 3rd party PBMC. After kidney transplantation, an expanded circulating CD4+ CD25+ T cell population characterized by the expression of CD45RO and IL-7R was found in most recipients, particularly in those with CHR. In a patient with long-term operational tolerance, this Tact population was similar to HS. Measuring circulating Tact may become a useful monitoring tool after transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxidative metabolism of the isolated embryonic heart of the chick has been determined using a spectrophotometric technique allowing global as well as localized micromeasurements of the O2 uptake. Entire hearts, excised from embryos of 10 somites (primordia fused, stage 10 HH) and 40 somites (S shaped, stage 20 HH) were placed in a special chamber under controlled metabolic conditions where they continued to beat spontaneously and regularly. During the 32 h of development, the O2 consumption of the whole heart increased from 0.9 +/- 0.1 to 5.3 +/- 0.8 nmol O2/h. These values corrected for protein content were, however, comparable (0.45 nmol O2.h-1.micrograms-1). At stage 10-12, the O2 uptake varied along the cardiac tube (from 0.74 to 1.0 nmol O2.h-1.mm-2). From stage 10 to 20, the O2 uptake per unit area of ventricle wall increased from 0.7 +/- 0.2 to 1.8 +/- 0.2 nmol O2.h-1.mm-2, and the O2 uptake per myocardial volume during one cardiac cycle varied from 7 to 2.5 nmol O2/cm3. These results indicate that, despite an intense morphogenesis, the cardiac tissue has a rather low and stable oxidative metabolism, although the O2 requirement of the whole heart increases significantly. Moreover, the normalized suprabasal aerobic energy expenditure decreases throughout early cardiogenesis. The functional integrity of the isolated embryonic heart combined with the experimental possibilities of the microtechnique make the preparation appropriate for studying the changes in cardiac metabolism during development.