47 resultados para 3D data


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative information from magnetic resonance imaging (MRI) may substantiate clinical findings and provide additional insight into the mechanism of clinical interventions in therapeutic stroke trials. The PERFORM study is exploring the efficacy of terutroban versus aspirin for secondary prevention in patients with a history of ischemic stroke. We report on the design of an exploratory longitudinal MRI follow-up study that was performed in a subgroup of the PERFORM trial. An international multi-centre longitudinal follow-up MRI study was designed for different MR systems employing safety and efficacy readouts: new T2 lesions, new DWI lesions, whole brain volume change, hippocampal volume change, changes in tissue microstructure as depicted by mean diffusivity and fractional anisotropy, vessel patency on MR angiography, and the presence of and development of new microbleeds. A total of 1,056 patients (men and women ≥ 55 years) were included. The data analysis included 3D reformation, image registration of different contrasts, tissue segmentation, and automated lesion detection. This large international multi-centre study demonstrates how new MRI readouts can be used to provide key information on the evolution of cerebral tissue lesions and within the macrovasculature after atherothrombotic stroke in a large sample of patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Xenobiotic exposure is a risk factor in the etiology of neurodegenerative disease. It was recently hypothesized that restricted exposure during brain development could predispose for a neurodegenerative disease later in life. As neuroinflammation contributes to progressive neurodegeneration, it is suspected that neurodevelopmental xenobiotic exposure could elicit a neuroinflammatory process, which over time may assume a detrimental character. We investigated the neurotoxic effects of paraquat (PQ) in three-dimensional whole rat brain cell cultures, exposed during an early differentiation stage, comparing immediate effects-directly post exposure-with long-term effects, 20 days after interrupted PQ-administration. Adverse effects and neuroinflammatory responses were assessed by measuring changes in gene- and protein-expression as well as by determining cell morphology changes. Differentiating neural cultures were highly susceptible to PQ and showed neuronal damage and strong astrogliosis. After the 20-day washout period, neurons partially recovered, whereas astrogliosis persisted, and was accompanied by microglial activation of a neurodegenerative phenotype. Our data shows that immediate and long-term effects of subchronic PQ-exposure differ. Also, PQ-exposure during this window of extensive neuronal differentiation led to a delayed microglial activation, of a character that could promote further pro-inflammatory signals that enable prolonged inflammation, thereby fueling further neurodegeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: To compare the different schemes that have been proposed during the last thirteen years to explain the renewal of the corneal epithelium. Material and Methods:We analyzed all the data present in the literature to explain the renewal of the corneal epithelium in mammals. According to the schemes proposed in the literature we developed a 3D animation to facilitate the understanding of the different concepts. Results:Three different schemes have been proposed to explain the renewal of the corneal epithelium in mammals during the last thirteen years. 1950-1981: the corneal epithelium was thought being renewed by mitosis of cells located in the basal layer. At this time scientist were not talking about stem cells. 1981-1986 was the period of the "XYZ hypothesis" or the transdifferentiation paradigm. At this time the conjunctival epithelium renewed the corneal epithelium in a centripetal migration. 1986-2008: the limbal stem cell paradigm, there were no stem cells in the corneal epithelium, all the corneal stem cells were located in the limbus and renewed the central cornea after a migration of 6 to 7 mm of transient amplifying cells toward the centre of the cornea. 2008, epithelial stem cells were found in the central cornea in mammals (Nature, Majo et al. November 2008). Discussion:We thought that the renewal of the corneal epithelium was completely defined. According to the last results we published in Nature, the current paradigm will be revisited. The experiments we made were on animals and the final demonstration on human has still to be done. If we find the same results in human, a new paradigm will be define and will change the way we consider ocular surface therapy and reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P < 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P < 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P < 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the dramatic increase in the volume of experimental results in every domain of life sciences, assembling pertinent data and combining information from different fields has become a challenge. Information is dispersed over numerous specialized databases and is presented in many different formats. Rapid access to experiment-based information about well-characterized proteins helps predict the function of uncharacterized proteins identified by large-scale sequencing. In this context, universal knowledgebases play essential roles in providing access to data from complementary types of experiments and serving as hubs with cross-references to many specialized databases. This review outlines how the value of experimental data is optimized by combining high-quality protein sequences with complementary experimental results, including information derived from protein 3D-structures, using as an example the UniProt knowledgebase (UniProtKB) and the tools and links provided on its website ( http://www.uniprot.org/ ). It also evokes precautions that are necessary for successful predictions and extrapolations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: In the present study, the impact of the two different fat suppression techniques was investigated for free breathing 3D spiral coronary magnetic resonance angiography (MRA). As the coronary arteries are embedded in epicardial fat and are adjacent to myocardial tissue, magnetization preparation such as T(2)-preparation and fat suppression is essential for coronary discrimination. MATERIALS AND METHODS: Fat-signal suppression in three-dimensional (3D) thin- slab coronary MRA based on a spiral k-space data acquisition can either be achieved by signal pre-saturation using a spectrally selective inversion recovery pre-pulse or by spectral-spatial excitation. In the present study, the performance of the two different approaches was studied in healthy subjects. RESULTS: No significant objective or subjective difference was found between the two fat suppression approaches. CONCLUSION: Spectral pre-saturation seems preferred for coronary MRA applications due to the ease of implementation and the shorter cardiac acquisition window.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUME L'Institut de Géophysique de l'Université de Lausanne a développé au cours de ces dernières années un système d'acquisition de sismique réflexion multitrace à haute résolution 2D et 3D. L'objectif de cette thèse était de poursuivre ce développement tout améliorant les connaissances de la géologie sous le lac Léman, en étudiant en particulier la configuration des grands accidents sous-lacustres dans la Molasse (Tertiaire) qui forme l'essentiel du substratum des formations quaternaires. En configuration 2D, notre système permet d'acquérir des profils sismiques avec une distance inter-CDP de 1,25 m. La couverture varie entre 6 et 18 selon le nombre de traces et la distance inter-tir. Le canon à air (15/15 eu. in.), offre une résolution verticale de 1,25 ni et une pénétration maximale de 300 m sous le fond de l'eau. Nous avons acquis au total plus de 400 km de sections 2D dans le Grand Lac et le Haut Lac entre octobre 2000 et juillet 2004. Une campagne de sismique 3D a fourni des données au large d'Evian sur une surface de 442,5 m sur 1450 m, soit 0,64 km2. La navigation ainsi que le positionnement des hydrophones et de la source ont été réalisés avec des GPS différentiels. Nous avons utilisé un traitement sismique conventionnel, sans appliquer d'AGC et en utilisant une migration post-stack. L'interprétation du substratum antéquaternaire est basée sur l'identification des sismofaciès, sur leurs relations avec les unités géologiques adjacentes au lac, ainsi que sur quelques données de forages. Nous obtenons ainsi une carte des unités géologiques dans le Grand Lac. Nous précisons la position du chevauchement subalpin entre la ville de Lausanne, sur la rive nord, et le bassin de Sciez, sur la rive sud. Dans la Molasse de Plateau, nous avons identifié les décrochements de Pontarlier et de St. Cergue ainsi que plusieurs failles non reconnues jusqu'ici. Nous avons cartographié les accidents qui affectent la Molasse subalpine ainsi que le plan de chevauchement du flysch sur la Molasse près de la rive sud du lac. Une nouvelle carte tectonique de la région lémanique a ainsi pu être dressée. L'analyse du substratum ne montre pas de failles suggérant une origine tectonique de la cuvette lémanique. Par contre, nous suggérons que la forme du creusement glaciaire, donc de la forme du lac Léman, a été influencée par la présence de failles dans le substratum antéquaternaire. L'analyse des sédiments quaternaires nous a permis de tracer des cartes des différentes interfaces ou unités qui les composent. La carte du toit du substratum antéquaternaire montre la présence de chenaux d'origine glaciaire dont la profondeur maximale atteint la cote -200 ni. Leur pente est dirigée vers le nord-est, à l'inverse du sens d'écoulement actuel des eaux. Nous expliquons cette observation par l'existence de circulations sous-glaciaires d'eau artésienne. Les sédiments glaciaires dont l'épaisseur maximale atteint 150 ni au centre du lac ont enregistré les différentes récurrences glaciaires. Dans la zone d'Evian, nous mettons en évidence la présence de lentilles de sédiments glaciolacustres perchées sur le flanc de la cuvette lémanique. Nous avons corrélé ces unités avec des données de forage et concluons qu'il s'agit du complexe inférieur de la pile sédimentaire d'Evian. Celui-ci, âgé de plus de 30 000 ans, serait un dépôt de Kame associé à un lac périglaciaire. La sismique réflexion 3D permet de préciser l'orientation de l'alimentation en matériel détritique de l'unité. La finesse des images obtenues nous permet également d'établir quels types d'érosion ont affecté certaines unités. Les sédiments lacustres, dont l'épaisseur maximale imagée atteint plus de 225 m et sans doute 400 ni sous le delta du Rhône, indiquent plusieurs mécanismes de dépôts. A la base, une mégaturbidite, épaisse d'une trentaine de mètres en moyenne, s'étend entre l'embouchure de la Dranse et le delta du Rhône. Au-dessus, la décantation des particules en suspension d'origine biologique et détritique fournit l'essentiel des sédiments. Dans la partie orientale du lac, les apports détritiques du Rhône forment un delta qui prograde vers l'ouest en s'imbriquant avec les sédiments déposés par décantation. La structure superficielle du delta a brutalement évolué, probablement à la suite de l'évènement catastrophique du Tauredunum (563 A.D.). Sa trace probable se marque par la présence d'une surface érosive que nous avons cartographiée. Le delta a ensuite changé de géométrie, avec notamment un déplacement des chenaux sous-lacustres. Sur l'ensemble de nos sections sismiques, nous n'observons aucune faille dans les sédiments quaternaires qui attesterait d'une tectonique postglaciaire du substratum. ABSTRACT During the last few years the institute of Geophysics of the University of Lausanne cleveloped a 2D and 3D high-resolution multichannel seismic reflection acquisition system. The objective of the present work was to carry on this development white improving our knowledge of the geology under Lake Geneva, in particular by studying the configuration of the large accidents affecting the Tertiary Molasse that makes up the basement of most Quaternary deposits. In its 2D configuration, our system makes it possible to acquire seismic profiles with a CDP interval of 1.25 m. The fold varies from 6 to 18 depending on the number of traces and the shooting interval. Our air gun (15/15 cu. in.) provides a vertical resolution of 1.25 m and a maximum penetration depth of approximately 300 m under water bottom. We acquired more than 400 km of 2D sections in the Grand Lac and the Haut Lac between October 2000 and July 2004. A 3D seismic survey off the city of Evian provided data on a surface of 442.5 m x 1450 m (0.64 km2). Ship's navigation as well as hydrophone- and source positioning were carried out with differential GPS. The seismic data were processed following a conventional sequence without .applying AGC and using post-stack migration. The interpretation of the pre-Quaternary substratum is based on sismofacies, on their relationships with terrestrial geological units and on some borehole data. We thus obtained a map of the geological units in the Grand Lac. We defined the location of the subalpine thrust from Lausanne, on the north shore, to the Sciez Basin, on the south shore. Within the Molasse de Plateau, we identified the already know Pontarlier and St Cergue transforms Fault as well as faults. We mapped faults that affect subalpine Molasse as well as the thrust fault plane between alpine flysch and Molasse near the lake's south shore. A new tectonic map of the Lake Geneva region could thus be drawn up. The substratum does not show faults indicating a tectonic origin for the Lake Geneva Basin. However, we suggest that the orientation of glacial erosion, and thus the shape of Lake Geneva, vas influenced by the presence of faults in the pre-Quaternary basement. The analysis of Quaternary sediments enabled us to draw up maps of various discontinuities or internal units. The top pre-Quaternary basement map shows channels of glacial origin, the deepest of them reaching an altitude of 200 m a.s.l. The channel's slopes are directed to the North-East, in opposite direction of the present water flow. We explain this observation by the presence of artesian subglacial water circulation. Glacial sediments, the maximum thickness of which reaches 150 m in the central part of the lake, record several glacial recurrences. In the Evian area, we found lenses of glacio-lacustrine sediments set high up on the flank of the Lake Geneva Bassin. We correlated these units with on-land borehole data and concluded that they represent the lower complex of the Evian sedimentary pile. The lower complex is aider than 30 000 years, and it could be a Kame deposit associated with a periglacial lake. Our 3D seismic reflexion survey enables us to specify the supply direction of detrital material in this unit. With detailed seismic images we established how some units were affected by different erosion types. The lacustrine sediments we imaged in Lake Geneva are thicker than 225 m and 400 m or more Linder the Rhone Delta. They indicate several depositional mechanisms. Their base is a major turbidite, thirty meters thick on average, that spreads between the Dranse mouth and the Rhone delta. Above this unit, settling of suspended biological and detrital particles provides most of the sediments. In the eastern part of the lake, detrital contribution from the Rhone builds a delta that progrades to the west and imbricates with the settling sediments. The shallow structure of the Rhone delta abruptly evolved, probably after the catastrophic Tauredunum event (563 A.D.). It probably coincides with an erosive surface that we mapped. As a result, the delta geometry changed, in particular associated with a displacement of water bottom channels. In all our seismic sections, we do not observe fault in the Quaternary sediments that would attest postglacial tectonic activity in the basement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to use the plantar pressure insole for estimating the three-dimensional ground reaction force (GRF) as well as the frictional torque (T(F)) during walking. Eleven subjects, six healthy and five patients with ankle disease participated in the study while wearing pressure insoles during several walking trials on a force-plate. The plantar pressure distribution was analyzed and 10 principal components of 24 regional pressure values with the stance time percentage (STP) were considered for GRF and T(F) estimation. Both linear and non-linear approximators were used for estimating the GRF and T(F) based on two learning strategies using intra-subject and inter-subjects data. The RMS error and the correlation coefficient between the approximators and the actual patterns obtained from force-plate were calculated. Our results showed better performance for non-linear approximation especially when the STP was considered as input. The least errors were observed for vertical force (4%) and anterior-posterior force (7.3%), while the medial-lateral force (11.3%) and frictional torque (14.7%) had higher errors. The result obtained for the patients showed higher error; nevertheless, when the data of the same patient were used for learning, the results were improved and in general slight differences with healthy subjects were observed. In conclusion, this study showed that ambulatory pressure insole with data normalization, an optimal choice of inputs and a well-trained nonlinear mapping function can estimate efficiently the three-dimensional ground reaction force and frictional torque in consecutive gait cycle without requiring a force-plate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While 3D thin-slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k-space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k-space gradient-echo and spiral k-space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T(2) preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R-R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) (both P < 0.001) and image quality. The single spiral per R-R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6-fold increase in SNR. The double-interleaf spiral approach showed a 50% reduction in scanning time, a 1.8-fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be "traded" for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The infiltration of river water into aquifers is of high relevance to drinking-water production and is a key driver of biogeochemical processes in the hyporheic and riparian zone, but the distribution and quantification of the infiltrating water are difficult to determine using conventional hydrological methods (e.g., borehole logging and tracer tests). By time-lapse inverting crosshole ERT (electrical resistivity tomography) monitoring data, we imaged groundwater flow patterns driven by river water infiltrating a perialpine gravel aquifer in northeastern Switzerland. This was possible because the electrical resistivity of the infiltrating water changed during rainfall-runoff events. Our time-lapse resistivity models indicated rather complex flow patterns as a result of spatially heterogeneous bank filtration and aquifer heterogeneity. The upper part of the aquifer was most affected by the river infiltrate, and the highest groundwater velocities and possible preferential flow occurred at shallow to intermediate depths. Time series of the reconstructed resistivity models matched groundwater electrical resistivity data recorded on borehole loggers in the upper and middle parts of the aquifer, whereas the resistivity models displayed smaller variations and delayed responses with respect to the logging data. in the lower part. This study demonstrated that crosshole ERT monitoring of natural electrical resistivity variations of river infiltrate could be used to image and quantify 3D bank filtration and aquifer dynamics at a high spatial resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The hydrogeological properties and responses of a productive aquifer in northeastern Switzerland are investigated. For this purpose, 3D crosshole electrical resistivity tomography (ERT) is used to define the main lithological structures within the aquifer (through static inversion) and to monitor the water infiltration from an adjacent river. During precipitation events and subsequent river flooding, the river water resistivity increases. As a consequence, the electrical characteristics of the infiltrating water can be used as a natural tracer to delineate preferential flow paths and flow velocities. The focus is primarily on the experiment installation, data collection strategy, and the structural characterization of the site and a brief overview of the ERT monitoring results. The monitoring system comprises 18 boreholes each equipped with 10 electrodes straddling the entire thickness of the gravel aquifer. A multi-channel resistivity system programmed to cycle through various four-point electrode configurations of the 180 electrodes in a rolling sequence allows for the measurement of approximately 15,500 apparent resistivity values every 7 h on a continuous basis. The 3D static ERT inversion of data acquired under stable hydrological conditions provides a base model for future time-lapse inversion studies and the means to investigate the resolving capability of our acquisition scheme. In particular, it enables definition of the main lithological structures within the aquifer. The final ERT static model delineates a relatively high-resistivity, low-porosity, intermediate-depth layer throughout the investigated aquifer volume that is consistent with results from well logging and seismic and radar tomography models. The next step will be to define and implement an appropriate time-lapse ERT inversion scheme using the river water as a natural tracer. The main challenge will be to separate the superposed time-varying effects of water table height, temperature, and salinity variations associated with the infiltrating water.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to compare coronary magnetic resonance angiography (MRA) data obtained with different scanning methodologies, adequate visualization and presentation of the coronary MRA data need to be ensured. Furthermore, an objective quantitative comparison between images acquired with different scanning methods is desirable. To address this need, a software tool ("Soap-Bubble") that facilitates visualization and quantitative comparison of 3D volume targeted coronary MRA data was developed. In the present implementation, the user interactively specifies a curved subvolume (enclosed in the 3D coronary MRA data set) that closely encompasses the coronary arterial segments. With a 3D Delaunay triangulation and a parallel projection, this enables the simultaneous display of multiple coronary segments in one 2D representation. For objective quantitative analysis, frequently explored quantitative parameters such as signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); and vessel length, sharpness, and diameter can be assessed. The present tool supports visualization and objective, quantitative comparisons of coronary MRA data obtained with different scanning methods. The first results obtained in healthy adults and in patients with coronary artery disease are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un système efficace de sismique tridimensionnelle (3-D) haute-résolution adapté à des cibles lacustres de petite échelle a été développé. Dans le Lac Léman, près de la ville de Lausanne, en Suisse, des investigations récentes en deux dimension (2-D) ont mis en évidence une zone de faille complexe qui a été choisie pour tester notre système. Les structures observées incluent une couche mince (<40 m) de sédiments quaternaires sub-horizontaux, discordants sur des couches tertiaires de molasse pentées vers le sud-est. On observe aussi la zone de faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau de la Molasse Subalpine. Deux campagnes 3-D complètes, d?environ d?un kilomètre carré, ont été réalisées sur ce site de test. La campagne pilote (campagne I), effectuée en 1999 pendant 8 jours, a couvert 80 profils en utilisant une seule flûte. Pendant la campagne II (9 jours en 2001), le nouveau système trois-flûtes, bien paramétrés pour notre objectif, a permis l?acquisition de données de très haute qualité sur 180 lignes CMP. Les améliorations principales incluent un système de navigation et de déclenchement de tirs grâce à un nouveau logiciel. Celui-ci comprend un contrôle qualité de la navigation du bateau en temps réel utilisant un GPS différentiel (dGPS) à bord et une station de référence près du bord du lac. De cette façon, les tirs peuvent être déclenchés tous les 5 mètres avec une erreur maximale non-cumulative de 25 centimètres. Tandis que pour la campagne I la position des récepteurs de la flûte 48-traces a dû être déduite à partir des positions du bateau, pour la campagne II elle ont pu être calculées précisément (erreur <20 cm) grâce aux trois antennes dGPS supplémentaires placées sur des flotteurs attachés à l?extrémité de chaque flûte 24-traces. Il est maintenant possible de déterminer la dérive éventuelle de l?extrémité des flûtes (75 m) causée par des courants latéraux ou de petites variations de trajet du bateau. De plus, la construction de deux bras télescopiques maintenant les trois flûtes à une distance de 7.5 m les uns des autres, qui est la même distance que celle entre les lignes naviguées de la campagne II. En combinaison avec un espacement de récepteurs de 2.5 m, la dimension de chaque «bin» de données 3-D de la campagne II est de 1.25 m en ligne et 3.75 m latéralement. L?espacement plus grand en direction « in-line » par rapport à la direction «cross-line» est justifié par l?orientation structurale de la zone de faille perpendiculaire à la direction «in-line». L?incertitude sur la navigation et le positionnement pendant la campagne I et le «binning» imprécis qui en résulte, se retrouve dans les données sous forme d?une certaine discontinuité des réflecteurs. L?utilisation d?un canon à air à doublechambre (qui permet d?atténuer l?effet bulle) a pu réduire l?aliasing observé dans les sections migrées en 3-D. Celui-ci était dû à la combinaison du contenu relativement haute fréquence (<2000 Hz) du canon à eau (utilisé à 140 bars et à 0.3 m de profondeur) et d?un pas d?échantillonnage latéral insuffisant. Le Mini G.I 15/15 a été utilisé à 80 bars et à 1 m de profondeur, est mieux adapté à la complexité de la cible, une zone faillée ayant des réflecteurs pentés jusqu?à 30°. Bien que ses fréquences ne dépassent pas les 650 Hz, cette source combine une pénétration du signal non-aliasé jusqu?à 300 m dans le sol (par rapport au 145 m pour le canon à eau) pour une résolution verticale maximale de 1.1 m. Tandis que la campagne I a été acquise par groupes de plusieurs lignes de directions alternées, l?optimisation du temps d?acquisition du nouveau système à trois flûtes permet l?acquisition en géométrie parallèle, ce qui est préférable lorsqu?on utilise une configuration asymétrique (une source et un dispositif de récepteurs). Si on ne procède pas ainsi, les stacks sont différents selon la direction. Toutefois, la configuration de flûtes, plus courtes que pour la compagne I, a réduit la couverture nominale, la ramenant de 12 à 6. Une séquence classique de traitement 3-D a été adaptée à l?échantillonnage à haute fréquence et elle a été complétée par deux programmes qui transforment le format non-conventionnel de nos données de navigation en un format standard de l?industrie. Dans l?ordre, le traitement comprend l?incorporation de la géométrie, suivi de l?édition des traces, de l?harmonisation des «bins» (pour compenser l?inhomogénéité de la couverture due à la dérive du bateau et de la flûte), de la correction de la divergence sphérique, du filtrage passe-bande, de l?analyse de vitesse, de la correction DMO en 3-D, du stack et enfin de la migration 3-D en temps. D?analyses de vitesse détaillées ont été effectuées sur les données de couverture 12, une ligne sur deux et tous les 50 CMP, soit un nombre total de 600 spectres de semblance. Selon cette analyse, les vitesses d?intervalles varient de 1450-1650 m/s dans les sédiments non-consolidés et de 1650-3000 m/s dans les sédiments consolidés. Le fait que l?on puisse interpréter plusieurs horizons et surfaces de faille dans le cube, montre le potentiel de cette technique pour une interprétation tectonique et géologique à petite échelle en trois dimensions. On distingue cinq faciès sismiques principaux et leurs géométries 3-D détaillées sur des sections verticales et horizontales: les sédiments lacustres (Holocène), les sédiments glacio-lacustres (Pléistocène), la Molasse du Plateau, la Molasse Subalpine de la zone de faille (chevauchement) et la Molasse Subalpine au sud de cette zone. Les couches de la Molasse du Plateau et de la Molasse Subalpine ont respectivement un pendage de ~8° et ~20°. La zone de faille comprend de nombreuses structures très déformées de pendage d?environ 30°. Des tests préliminaires avec un algorithme de migration 3-D en profondeur avant sommation et à amplitudes préservées démontrent que la qualité excellente des données de la campagne II permet l?application de telles techniques à des campagnes haute-résolution. La méthode de sismique marine 3-D était utilisée jusqu?à présent quasi-exclusivement par l?industrie pétrolière. Son adaptation à une échelle plus petite géographiquement mais aussi financièrement a ouvert la voie d?appliquer cette technique à des objectifs d?environnement et du génie civil.<br/><br/>An efficient high-resolution three-dimensional (3-D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, past high-resolution two-dimensional (2-D) investigations revealed a complex fault zone (the Paudèze thrust zone), which was subsequently chosen for testing our system. Observed structures include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie southeast-dipping Tertiary Molasse beds and the Paudèze thrust zone, which separates Plateau and Subalpine Molasse units. Two complete 3-D surveys have been conducted over this same test site, covering an area of about 1 km2. In 1999, a pilot survey (Survey I), comprising 80 profiles, was carried out in 8 days with a single-streamer configuration. In 2001, a second survey (Survey II) used a newly developed three-streamer system with optimized design parameters, which provided an exceptionally high-quality data set of 180 common midpoint (CMP) lines in 9 days. The main improvements include a navigation and shot-triggering system with in-house navigation software that automatically fires the gun in combination with real-time control on navigation quality using differential GPS (dGPS) onboard and a reference base near the lake shore. Shots were triggered at 5-m intervals with a maximum non-cumulative error of 25 cm. Whereas the single 48-channel streamer system of Survey I requires extrapolation of receiver positions from the boat position, for Survey II they could be accurately calculated (error <20 cm) with the aid of three additional dGPS antennas mounted on rafts attached to the end of each of the 24- channel streamers. Towed at a distance of 75 m behind the vessel, they allow the determination of feathering due to cross-line currents or small course variations. Furthermore, two retractable booms hold the three streamers at a distance of 7.5 m from each other, which is the same distance as the sail line interval for Survey I. With a receiver spacing of 2.5 m, the bin dimension of the 3-D data of Survey II is 1.25 m in in-line direction and 3.75 m in cross-line direction. The greater cross-line versus in-line spacing is justified by the known structural trend of the fault zone perpendicular to the in-line direction. The data from Survey I showed some reflection discontinuity as a result of insufficiently accurate navigation and positioning and subsequent binning errors. Observed aliasing in the 3-D migration was due to insufficient lateral sampling combined with the relatively high frequency (<2000 Hz) content of the water gun source (operated at 140 bars and 0.3 m depth). These results motivated the use of a double-chamber bubble-canceling air gun for Survey II. A 15 / 15 Mini G.I air gun operated at 80 bars and 1 m depth, proved to be better adapted for imaging the complexly faulted target area, which has reflectors dipping up to 30°. Although its frequencies do not exceed 650 Hz, this air gun combines a penetration of non-aliased signal to depths of 300 m below the water bottom (versus 145 m for the water gun) with a maximum vertical resolution of 1.1 m. While Survey I was shot in patches of alternating directions, the optimized surveying time of the new threestreamer system allowed acquisition in parallel geometry, which is preferable when using an asymmetric configuration (single source and receiver array). Otherwise, resulting stacks are different for the opposite directions. However, the shorter streamer configuration of Survey II reduced the nominal fold from 12 to 6. A 3-D conventional processing flow was adapted to the high sampling rates and was complemented by two computer programs that format the unconventional navigation data to industry standards. Processing included trace editing, geometry assignment, bin harmonization (to compensate for uneven fold due to boat/streamer drift), spherical divergence correction, bandpass filtering, velocity analysis, 3-D DMO correction, stack and 3-D time migration. A detailed semblance velocity analysis was performed on the 12-fold data set for every second in-line and every 50th CMP, i.e. on a total of 600 spectra. According to this velocity analysis, interval velocities range from 1450-1650 m/s for the unconsolidated sediments and from 1650-3000 m/s for the consolidated sediments. Delineation of several horizons and fault surfaces reveal the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3-D geometries can be distinguished in vertical and horizontal sections: lacustrine sediments (Holocene) , glaciolacustrine sediments (Pleistocene), Plateau Molasse, Subalpine Molasse and its thrust fault zone. Dips of beds within Plateau and Subalpine Molasse are ~8° and ~20°, respectively. Within the fault zone, many highly deformed structures with dips around 30° are visible. Preliminary tests with 3-D preserved-amplitude prestack depth migration demonstrate that the excellent data quality of Survey II allows application of such sophisticated techniques even to high-resolution seismic surveys. In general, the adaptation of the 3-D marine seismic reflection method, which to date has almost exclusively been used by the oil exploration industry, to a smaller geographical as well as financial scale has helped pave the way for applying this technique to environmental and engineering purposes.<br/><br/>La sismique réflexion est une méthode d?investigation du sous-sol avec un très grand pouvoir de résolution. Elle consiste à envoyer des vibrations dans le sol et à recueillir les ondes qui se réfléchissent sur les discontinuités géologiques à différentes profondeurs et remontent ensuite à la surface où elles sont enregistrées. Les signaux ainsi recueillis donnent non seulement des informations sur la nature des couches en présence et leur géométrie, mais ils permettent aussi de faire une interprétation géologique du sous-sol. Par exemple, dans le cas de roches sédimentaires, les profils de sismique réflexion permettent de déterminer leur mode de dépôt, leurs éventuelles déformations ou cassures et donc leur histoire tectonique. La sismique réflexion est la méthode principale de l?exploration pétrolière. Pendant longtemps on a réalisé des profils de sismique réflexion le long de profils qui fournissent une image du sous-sol en deux dimensions. Les images ainsi obtenues ne sont que partiellement exactes, puisqu?elles ne tiennent pas compte de l?aspect tridimensionnel des structures géologiques. Depuis quelques dizaines d?années, la sismique en trois dimensions (3-D) a apporté un souffle nouveau à l?étude du sous-sol. Si elle est aujourd?hui parfaitement maîtrisée pour l?imagerie des grandes structures géologiques tant dans le domaine terrestre que le domaine océanique, son adaptation à l?échelle lacustre ou fluviale n?a encore fait l?objet que de rares études. Ce travail de thèse a consisté à développer un système d?acquisition sismique similaire à celui utilisé pour la prospection pétrolière en mer, mais adapté aux lacs. Il est donc de dimension moindre, de mise en oeuvre plus légère et surtout d?une résolution des images finales beaucoup plus élevée. Alors que l?industrie pétrolière se limite souvent à une résolution de l?ordre de la dizaine de mètres, l?instrument qui a été mis au point dans le cadre de ce travail permet de voir des détails de l?ordre du mètre. Le nouveau système repose sur la possibilité d?enregistrer simultanément les réflexions sismiques sur trois câbles sismiques (ou flûtes) de 24 traces chacun. Pour obtenir des données 3-D, il est essentiel de positionner les instruments sur l?eau (source et récepteurs des ondes sismiques) avec une grande précision. Un logiciel a été spécialement développé pour le contrôle de la navigation et le déclenchement des tirs de la source sismique en utilisant des récepteurs GPS différentiel (dGPS) sur le bateau et à l?extrémité de chaque flûte. Ceci permet de positionner les instruments avec une précision de l?ordre de 20 cm. Pour tester notre système, nous avons choisi une zone sur le Lac Léman, près de la ville de Lausanne, où passe la faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau et de la Molasse Subalpine. Deux campagnes de mesures de sismique 3-D y ont été réalisées sur une zone d?environ 1 km2. Les enregistrements sismiques ont ensuite été traités pour les transformer en images interprétables. Nous avons appliqué une séquence de traitement 3-D spécialement adaptée à nos données, notamment en ce qui concerne le positionnement. Après traitement, les données font apparaître différents faciès sismiques principaux correspondant notamment aux sédiments lacustres (Holocène), aux sédiments glacio-lacustres (Pléistocène), à la Molasse du Plateau, à la Molasse Subalpine de la zone de faille et la Molasse Subalpine au sud de cette zone. La géométrie 3-D détaillée des failles est visible sur les sections sismiques verticales et horizontales. L?excellente qualité des données et l?interprétation de plusieurs horizons et surfaces de faille montrent le potentiel de cette technique pour les investigations à petite échelle en trois dimensions ce qui ouvre des voies à son application dans les domaines de l?environnement et du génie civil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.