387 resultados para CT ANGIOGRAPHY
Resumo:
Despite the undeniable advantages of postmortem angiography, numerous questions have arisen concerning the influence that the injected contrast media may exercise on biological fluids and tissues collected for toxicological and biochemical investigations. Moreover, cardiac blood for microbiological investigations cannot be obtained post-angiography. In this study, we examined whether the peripheral blood collected prior to postmortem angiography, using percutaneous access to femoral vessels after skin surface disinfection, could be suitable for microbiological investigations when postmortem angiography with femoral vessel cannulation is also performed. A total of 66 cases were included in the study and were divided into two subgroups (angiography and bacteriology group, 33 cases and control group, 33 cases). Autopsies, histology, toxicology, bacteriology, and biochemical investigations (procalcitonin, C-reactive protein, interleukin-6, and soluble triggering receptors expressed on myeloid cells type 1) were performed in all cases. No statistically significant differences between the two groups were noted, and identified category distribution (death unrelated to infection, true infection, false positive, and undetermined) was rather similar in both studied populations. These preliminary results suggest that postmortem angiography using a femoral approach does not constitute an impediment to the collection of peripheral blood for microbiology and vice versa. Moreover, the use of femoral blood for microbiology does not lead to an increased risk of doubtful results.
Resumo:
Introduction: MCTI is used to assess acute ischemic stroke (AIS) patients.We postulated that use of MCTI improves patient outcome regardingindependence and mortality.Methods: From the ASTRAL registry, all patients with an AIS and a non-contrast-CT (NCCT), angio-CT (CTA) or perfusion-CT (CTP) within24 h from onset were included. Demographic, clinical, biological, radio-logical, and follow-up caracteristics were collected. Significant predictorsof MCTI use were fitted in a multivariate analysis. Patients undergoingCTA or CTA&CTP were compared with NCCT patients with regards tofavourable outcome (mRS ≤ 2) at 3 months, 12 months mortality, strokemechanism, short-term renal function, use of ancillary diagnostic tests,duration of hospitalization and 12 months stroke recurrence.
Resumo:
BACKGROUND: Endovascular treatment for acute ischemic stroke patients was recently shown to improve recanalization rates and clinical outcome in a well-defined study population. Intravenous thrombolysis (IVT) alone is insufficiently effective to recanalize in certain patients or of little value in others. Accordingly, we aimed at identifying predictors of recanalization in patients treated with or without IVT. METHODS: In the observational Acute Stroke Registry and Analysis of Lausanne (ASTRAL) registry, we selected those stroke patients (1) with an arterial occlusion on computed tomography angiography (CTA) imaging, (2) who had an arterial patency assessment at 24 hours (CTA/magnetic resonance angiography/transcranial Doppler), and (3) who were treated with IVT or had no revascularization treatment. Based on 2 separate logistic regression analyses, predictors of spontaneous and post-thrombolytic recanalization were generated. RESULTS: Partial or complete recanalization was achieved in 121 of 210 (58%) thrombolyzed patients. Recanalization was associated with atrial fibrillation (odds ratio , 1.6; 95% confidence interval, 1.2-3.0) and absence of early ischemic changes on CT (1.1, 1.1-1.2) and inversely correlated with the presence of a significant extracranial (EC) stenosis or occlusion (.6, .3-.9). In nonthrombolyzed patients, partial or complete recanalization was significantly less frequent (37%, P < .01). The recanalization was independently associated with a history of hypercholesterolemia (2.6, 1.2-5.6) and the proximal site of the intracranial occlusion (2.5, 1.2-5.4), and inversely correlated with a decreased level of consciousness (.3, .1-.8), and EC (.3, .1-.6) and basilar artery pathology (.1, .0-.6). CONCLUSIONS: Various clinical findings, cardiovascular risk factors, and arterial pathology on acute CTA-based imaging are moderately associated with spontaneous and post-thrombolytic arterial recanalization at 24 hours. If confirmed in other studies, this information may influence patient selection toward the most appropriate revascularization strategy.
Resumo:
PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.
Resumo:
Le nombre d'examens tomodensitométriques (Computed Tomography, CT) effectués chaque année étant en constante augmentation, différentes techniques d'optimisation, dont les algorithmes de reconstruction itérative permettant de réduire le bruit tout en maintenant la résolution spatiale, ont étés développées afin de réduire les doses délivrées. Le but de cette étude était d'évaluer l'impact des algorithmes de reconstruction itérative sur la qualité image à des doses effectives inférieures à 0.3 mSv, comparables à celle d'une radiographie thoracique. Vingt CT thoraciques effectués à cette dose effective ont été reconstruits en variant trois paramètres: l'algorithme de reconstruction, rétroprojection filtrée versus reconstruction itérative iDose4; la matrice, 5122 versus 7682; et le filtre de résolution en densité (mou) versus spatiale (dur). Ainsi, 8 séries ont été reconstruites pour chacun des 20 CT thoraciques. La qualité d'image de ces 8 séries a d'abord été évaluée qualitativement par deux radiologues expérimentés en aveugle en se basant sur la netteté des parois bronchiques et de l'interface entre le parenchyme pulmonaire et les vaisseaux, puis quantitativement en utilisant une formule de merit, fréquemment utilisée dans le développement de nouveaux algorithmes et filtres de reconstruction. La performance diagnostique de la meilleure série acquise à une dose effective inférieure à 0.3 mSv a été comparée à celle d'un CT de référence effectué à doses standards en relevant les anomalies du parenchyme pulmonaire. Les résultats montrent que la meilleure qualité d'image, tant qualitativement que quantitativement a été obtenue en utilisant iDose4, la matrice 5122 et le filtre mou, avec une concordance parfaite entre les classements quantitatif et qualitatif des 8 séries. D'autre part, la détection des nodules pulmonaires de plus de 4mm étaient similaire sur la meilleure série acquise à une dose effective inférieure à 0.3 mSv et le CT de référence. En conclusion, les CT thoraciques effectués à une dose effective inférieure à 0.3 mSv reconstruits avec iDose4, la matrice 5122 et le filtre mou peuvent être utilisés avec confiance pour diagnostiquer les nodules pulmonaires de plus de 4mm.
Resumo:
Postmortem imaging techniques, especially postmortem computed tomography, have become integral tools in forensic investigations. Multiphase postmortem computed tomography angiography (MPMCTA) visualizes the vascular system in detail and makes it possible to evaluate the perfusion of even the smallest vessels. Although the technique has been well described for adults, no pediatric cases have been reported and no pediatric protocol has been established for this type of investigation. We present the case a 7-year-old child for which we used a previously described MPMCTA protocol and adapted values of perfusion, with the same technical equipment as for adult cases. Our main objective was to propose a perfusion protocol adapted for the investigation of infants and children. Moreover, we discuss both the difficulties that we encountered and possible ways to further improve the investigation of pediatric cases by MPMCTA.
Resumo:
OBJECTIVES: To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients' characteristics. METHODS: Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle. RESULTS: The mean attenuation was 46 HU (range, 17-84 HU) with mean SD 23 HU for the blood, and 39 HU (10-82 HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p < 0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%. CONCLUSIONS: Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient's characteristics, a better approach might be an adaptive threshold.