369 resultados para Seasonal monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

New oral targeted anticancer therapies are revolutionizing cancer treatment by transforming previously deadly malignancies into chronically manageable conditions. Nevertheless, drug resistance, persistence of cancer stem cells, and adverse drug effects still limit their ability to stabilize or cure malignant diseases in the long term. Response to targeted anticancer therapy is influenced by tumor genetics and by variability in drug concentrations. However, despite a significant inter-patient pharmacokinetic variability, targeted anticancer drugs are essentially licensed at fixed doses. Their therapeutic use could however be optimized by individualization of their dosage, based on blood concentration measurements via the therapeutic drug monitoring (TDM). TDM can increase the probability of therapeutic responses to targeted anticancer therapies, and would help minimize the risk of major adverse reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. We elaborated a model that predicts the centiles of the 25(OH)D distribution taking into account seasonal variation. Methods. Data from two Swiss population-based studies were used to generate (CoLaus) and validate (Bus Santé) the model. Serum 25(OH)D was measured by ultra high pressure LC-MS/MS and immunoassay. Linear regression models on square-root transformed 25(OH)D values were used to predict centiles of the 25(OH)D distribution. Distribution functions of the observations from the replication set predicted with the model were inspected to assess replication. Results. Overall, 4,912 and 2,537 Caucasians were included in original and replication sets, respectively. Mean (SD) 25(OH)D, age, BMI, and % of men were 47.5 (22.1) nmol/L, 49.8 (8.5) years, 25.6 (4.1) kg/m(2), and 49.3% in the original study. The best model included gender, BMI, and sin-cos functions of measurement day. Sex- and BMI-specific 25(OH)D centile curves as a function of measurement date were generated. The model estimates any centile of the 25(OH)D distribution for given values of sex, BMI, and date and the quantile corresponding to a 25(OH)D measurement. Conclusions. We generated and validated centile curves of 25(OH)D in the general adult Caucasian population. These curves can help rank vitamin D centile independently of when 25(OH)D is measured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A headspace-gas chromatography-tandem mass spectrometry (HS-GC-MS/MS) method for the trace measurement of perfluorocarbon compounds (PFCs) in blood was developed. Due to oxygen carrying capabilities of PFCs, application to doping and sports misuse is speculated. This study was therefore extended to perform validation methods for F-tert-butylcyclohexane (Oxycyte(®)), perfluoro(methyldecalin) (PFMD) and perfluorodecalin (PFD). The limit of detection of these compounds was established and found to be 1.2µg/mL blood for F-tert-butylcyclohexane, 4.9µg/mL blood for PFMD and 9.6µg/mL blood for PFD. The limit of quantification was assumed to be 12µg/mL blood (F-tert-butylcyclohexane), 48µg/mL blood (PFMD) and 96µg/mL blood (PFD). HS-GC-MS/MS technique allows detection from 1000 to 10,000 times lower than the estimated required dose to ensure a biological effect for the investigated PFCs. Thus, this technique could be used to identify a PFC misuse several hours, maybe days, after the injection or the sporting event. Clinical trials with those compounds are still required to evaluate the validation parameters with the calculated estimations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study shows how a new generation of terrestrial laser scanners can be used to investigate glacier surface ablation and other elements of glacial hydrodynamics at exceptionally high spatial and temporal resolution. The study area is an Alpine valley glacier, Haut Glacier d'Arolla, Switzerland. Here we use an ultra-long-range lidar RIEGL VZ-6000 scanner, having a laser specifically designed for measurement of snow- and ice-cover surfaces. We focus on two timescales: seasonal and daily. Our results show that a near-infrared scanning laser system can provide high-precision elevation change and ablation data from long ranges, and over relatively large sections of the glacier surface. We use it to quantify spatial variations in the patterns of surface melt at the seasonal scale, as controlled by both aspect and differential debris cover. At the daily scale, we quantify the effects of ogive-related differences in ice surface debris content on spatial patterns of ablation. Daily scale measurements point to possible hydraulic jacking of the glacier associated with short-term water pressure rises. This latter demonstration shows that this type of lidar may be used to address subglacial hydrologic questions, in addition to motion and ablation measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the tools proposed to assess the athlete's "fatigue," the analysis of heart rate variability (HRV) provides an indirect evaluation of the settings of autonomic control of heart activity. HRV analysis is performed through assessment of time-domain indices, the square root of the mean of the sum of the squares of differences between adjacent normal R-R intervals (RMSSD) measured during short (5 min) recordings in supine position upon awakening in the morning and particularly the logarithm of RMSSD (LnRMSSD) has been proposed as the most useful resting HRV indicator. However, if RMSSD can help the practitioner to identify a global "fatigue" level, it does not allow discriminating different types of fatigue. Recent results using spectral HRV analysis highlighted firstly that HRV profiles assessed in supine and standing positions are independent and complementary; and secondly that using these postural profiles allows the clustering of distinct sub-categories of "fatigue." Since, cardiovascular control settings are different in standing and lying posture, using the HRV figures of both postures to cluster fatigue state embeds information on the dynamics of control responses. Such, HRV spectral analysis appears more sensitive and enlightening than time-domain HRV indices. The wealthier information provided by this spectral analysis should improve the monitoring of the adaptive training-recovery process in athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of testosterone abuse in sports is routinely achieved through the 'steroidal module' of the Athlete Biological Passport by GC-MS(/MS) quantification of selected endogenous anabolic androgenic steroids (EAAS) from athletes' urines. To overcome some limitations of the "urinary steroid profile" such as the presence of confounding factors (ethnicity, enzyme polymorphism, bacterial contamination, and ethanol), ultrahigh performance liquid chromatography (UHPLC) measurements of blood concentrations of testosterone, its major metabolites, and precursors could represent an interesting and complementary strategy. In this work, two UHPLC-MS/MS methods were developed for the quantification of testosterone and related compounds in human serum, including major progestogens, corticoids, and estrogens. The validated methods were then used for the analyses of serum samples collected from 19 healthy male volunteers after oral and transdermal testosterone administration. Results from unsupervised multiway analysis allowed variations of target analytes to be assessed simultaneously over a 96-h time period. Except for alteration of concentration values due to the circadian rhythm, which concerns mainly corticosteroids, DHEA, and progesterone, significant variations linked to the oral and transdermal testosterone administration were observed for testosterone, DHT, and androstenedione. As a second step of analysis, the longitudinal monitoring of these biomarkers using intra-individual thresholds showed, in comparison to urine, significant improvements in the detection of testosterone administration, especially for volunteers with del/del genotype for phase II UGT2B17 enzyme, not sensitive to the main urinary marker, T/E ratio. A substantial extension of the detection window after transdermal testosterone administration was also observed in serum matrix. The longitudinal follow-up proposed in this study represents a first example of 'blood steroid profile' in doping control analysis, which can be proposed in the future as a complement to the 'urinary module' for improving steroid abuse detection capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the tools proposed to assess the athlete's "fatigue," the analysis of heart rate variability (HRV) provides an indirect evaluation of the settings of autonomic control of heart activity. HRV analysis is performed through assessment of time-domain indices, the square root of the mean of the sum of the squares of differences between adjacent normal R-R intervals (RMSSD) measured during short (5 min) recordings in supine position upon awakening in the morning and particularly the logarithm of RMSSD (LnRMSSD) has been proposed as the most useful resting HRV indicator. However, if RMSSD can help the practitioner to identify a global "fatigue" level, it does not allow discriminating different types of fatigue. Recent results using spectral HRV analysis highlighted firstly that HRV profiles assessed in supine and standing positions are independent and complementary; and secondly that using these postural profiles allows the clustering of distinct sub-categories of "fatigue." Since, cardiovascular control settings are different in standing and lying posture, using the HRV figures of both postures to cluster fatigue state embeds information on the dynamics of control responses. Such, HRV spectral analysis appears more sensitive and enlightening than time-domain HRV indices. The wealthier information provided by this spectral analysis should improve the monitoring of the adaptive training-recovery process in athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To assess seasonal, weekday, and public holiday effects on alcohol-related road accidents and drinking diaries among young Swiss men. METHODS: Federal road accident data (35,485 accidents) from Switzerland and drinking diary data from a large cohort of young Swiss men (11,930 subjects) were analysed for temporal effects by calendar week, weekday and public holiday (Christmas, New Years, National Day). Alcohol-related accidents were analysed using rate ratios for observed versus expected numbers of accidents and proportions of alcohol-related accidents relative to the total number. Drinking diaries were analysed for the proportion of drinkers, median number of drinks consumed, and the 90th percentile's number of drinks consumed. RESULTS: Several parallel peaks were identified in alcohol-related accidents and drinking diaries. These included increases on Fridays and Saturdays, with Saturday drinking extending until early Sunday morning, an increase during the summer on workdays but not weekends, an increase at the end of the year, and increases on public holidays and the evening before. CONCLUSIONS: Our results suggest specific time-windows that are associated with increases in drinking and alcohol-related harm. Established prevention measures should be enforced during these time-windows to reduce associated peaks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Biological rhythmicity has been extensively studied in animals for many decades. Although temporal patterns of physical activity have been identified in humans, no large-scale, multi-national study has been published, and no comparison has been attempted of the ubiquity of activity rhythms at different time scales (such as daily, weekly, monthly, and annual). Methods Using individually worn actigraphy devices, physical activity of 2,328 individuals from five different countries (adults of African descent from Ghana, South Africa, Jamaica, Seychelles, and the United States) was measured for seven consecutive days at different times of the year. Results Analysis for rhythmic patterns identified daily rhythmicity of physical activity in all five of the represented nationalities. Weekly rhythmicity was found in some, but not all, of the nationalities. No significant evidence of lunar rhythmicity or seasonal rhythmicity was found in any of the groups. Conclusions These findings extend previous small-scale observations of daily rhythmicity to a large cohort of individuals from around the world. The findings also confirm the existence of modest weekly rhythmicity but not lunar or seasonal rhythmicity in human activity. These differences in rhythm strength have implications for the management of health hazards of rhythm misalignment. Key Messages Analysis of the pattern of physical activity of 2,328 individuals from five countries revealed strong daily rhythmicity in all five countries, moderate weekly rhythmicity in some countries, and no lunar rhythmicity or seasonal rhythmicity in any of the countries.