336 resultados para Radiotherapy dosage
Resumo:
Hypoglycemia is a potentially serious complication of insulin therapy. Some insulin-dependent diabetic patients can benefit from continuous subcutaneous insulin infusion therapy (an "insulin pump"), which in most case improves glycemia control and decreases the occurrence of hypoglycemic episodes. However, such events may occur, particularly during initial treatment phases or pregnancy. Severe hypoglycemia is mainly managed by stopping the insulin pump and insuring an adequate carbohydrate intake. Patients with insulin pumps and their entourage should receive specific instruction in the adjustment of pump flow in the presence of dysglycemia-inducing circumstances (illness, physical exertion), as well as in anticipation of high-risk situations, such as motor-vehicle driving.
Resumo:
In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.
Resumo:
Exogenous administration of glucocorticoids is a widely used and efficient tool to investigate the effects of elevated concentrations of these hormones in field studies. Because the effects of corticosterone are dose and duration-dependent, the exact course of plasma corticosterone levels after exogenous administration needs to be known. We tested the performance of self-degradable corticosterone pellets (implanted under the skin) in elevating plasma corticosterone levels. We monitored baseline (sampled within 3min after capture) total corticosterone levels and investigated potential interactions with corticosteroid-binding-globulin (CBG) capacity and the endogenous corticosterone response to handling in Eurasian kestrel Falco tinnunculus and barn owl Tyto alba nestlings. Corticosterone pellets designed for a 7-day-release in rodents elevated circulating baseline total corticosterone during only 2-3 days compared to placebo-nestlings. Highest levels occurred 1-2days after implantation and levels decreased strongly thereafter. CBG capacity was also increased, resulting in a smaller, but still significant, increase in baseline free corticosterone levels. The release of endogenous corticosterone as a response to handling was strong in placebo-nestlings, but absent 2 and 8 days after corticosterone pellet implantation. This indicates a potential shut-down of the hypothalamo-pituitary-adrenal axis after the 2-3 days of elevated baseline corticosterone levels. 20 days after pellet implantation, the endogenous corticosterone response to handling of nestlings implanted with corticosterone pellets attained similar levels as in placebo-nestlings. Self-degradable pellets proved to be an efficient tool to artificially elevate circulating baseline corticosterone especially in field studies, requiring only one intervention. The resulting peak-like elevation of circulating corticosterone, the concomitant elevation of CBG capacity, and the absence of an endogenous corticosterone response to an acute stressor have to be taken into account.
Resumo:
BACKGROUND: Protein-energy wasting is a frequent and debilitating condition in maintenance dialysis. We randomly tested if an energy-dense, phosphate-restricted, renal-specific oral supplement could maintain adequate nutritional intake and prevent malnutrition in maintenance haemodialysis patients with insufficient intake. METHODS: Eighty-six patients were assigned to a standard care (CTRL) group or were prescribed two 125-ml packs of Renilon 7.5(R) daily for 3 months (SUPP). Dietary intake, serum (S) albumin, prealbumin, protein nitrogen appearance (nPNA), C-reactive protein, subjective global assessment (SGA) and quality of life (QOL) were recorded at baseline and after 3 months. RESULTS: While intention to treat analysis (ITT) did not reveal strong statistically significant changes in dietary intake between groups, per protocol (PP) analysis showed that the SUPP group increased protein (P < 0.01) and energy (P < 0.01) intakes. In contrast, protein and energy intakes further deteriorated in the CTRL group (PP). Although there was no difference in serum albumin and prealbumin changes between groups, in the total population serum albumin and prealbumin changes were positively associated with the increment in protein intake (r = 0.29, P = 0.01 and r = 0.27, P = 0.02, respectively). The SUPP group did not increase phosphate intake, phosphataemia remained unaffected, and the use of phosphate binders remained stable or decreased. The SUPP group exhibited improved SGA and QOL (P < 0.05). CONCLUSION: This study shows that providing maintenance haemodialysis patients with insufficient intake with a renal-specific oral supplement may prevent deterioration in nutritional indices and QOL without increasing the need for phosphate binders.