361 resultados para GROUNDWATER MONITORING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Table des matières] 1. Introduction. 2. Méthode. 3. Prévention. 4. Thérapies. 5. Réduction des risques. 6. Formation. 7. Coordination nationale. 8. Migration et santé. 9. Epidémiologie. 10. Recherche. 11. Evaluation. 12. Annexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Steep mountain catchments typically experience large sediment pulses from hillslopes which are stored in headwater channels and remobilized by debris-flows or bedload transport. Event-based sediment budget monitoring in the active Manival debris-flow torrent in the French Alps during a two-year period gave insights into the catchment-scale sediment routing during moderate rainfall intensities which occur several times each year. The monitoring was based on intensive topographic resurveys of low- and high-order channels using different techniques (cross-section surveys with total station and high-resolution channel surveys with terrestrial and airborne laser scanning). Data on sediment output volumes from the main channel were obtained by a sediment trap. Two debris-flows were observed, as well as several bedload transport flow events. Sediment budget analysis of the two debris-flows revealed that most of the debris-flow volumes were supplied by channel scouring (more than 92%). Bedload transport during autumn contributed to the sediment recharge of high-order channels by the deposition of large gravel wedges. This process is recognized as being fundamental for debris-flow occurrence during the subsequent spring and summer. A time shift of scour-and-fill sequences was observed between low- and high-order channels, revealing the discontinuous sediment transfer in the catchment during common flow events. A conceptual model of sediment routing for different event magnitude is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proteins can switch between different conformations in response to stimuli, such as pH or temperature variations, or to the binding of ligands. Such plasticity and its kinetics can have a crucial functional role, and their characterization has taken center stage in protein research. As an example, Topoisomerases are particularly interesting enzymes capable of managing tangled and supercoiled double-stranded DNA, thus facilitating many physiological processes. In this work, we describe the use of a cantilever-based nanomotion sensor to characterize the dynamics of human topoisomerase II (Topo II) enzymes and their response to different kinds of ligands, such as ATP, which enhance the conformational dynamics. The sensitivity and time resolution of this sensor allow determining quantitatively the correlation between the ATP concentration and the rate of Topo II conformational changes. Furthermore, we show how to rationalize the experimental results in a comprehensive model that takes into account both the physics of the cantilever and the dynamics of the ATPase cycle of the enzyme, shedding light on the kinetics of the process. Finally, we study the effect of aclarubicin, an anticancer drug, demonstrating that it affects directly the Topo II molecule inhibiting its conformational changes. These results pave the way to a new way of studying the intrinsic dynamics of proteins and of protein complexes allowing new applications ranging from fundamental proteomics to drug discovery and development and possibly to clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cell death is essential for a plethora of physiological processes, and its deregulation characterizes numerous human diseases. Thus, the in-depth investigation of cell death and its mechanisms constitutes a formidable challenge for fundamental and applied biomedical research, and has tremendous implications for the development of novel therapeutic strategies. It is, therefore, of utmost importance to standardize the experimental procedures that identify dying and dead cells in cell cultures and/or in tissues, from model organisms and/or humans, in healthy and/or pathological scenarios. Thus far, dozens of methods have been proposed to quantify cell death-related parameters. However, no guidelines exist regarding their use and interpretation, and nobody has thoroughly annotated the experimental settings for which each of these techniques is most appropriate. Here, we provide a nonexhaustive comparison of methods to detect cell death with apoptotic or nonapoptotic morphologies, their advantages and pitfalls. These guidelines are intended for investigators who study cell death, as well as for reviewers who need to constructively critique scientific reports that deal with cellular demise. Given the difficulties in determining the exact number of cells that have passed the point-of-no-return of the signaling cascades leading to cell death, we emphasize the importance of performing multiple, methodologically unrelated assays to quantify dying and dead cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans le cadre de la planification de l'entraînement d'un athlète, l'affûtage précompétitif consiste à réduire les charges d'entraînement et éliminer le stress des séances précédentes afin d'optimiser les performances futures. Il existe des outils pour analyser les changements physiologiques qui se manifestent dans l'organisme des sportifs pendant cette période et qui sont responsables du gain de performance. L'analyse des indices corporels par bioimpédancemétrie pourrait constituer un outil simple et non invasif pour monitorer les performances et l'entraînement des sportifs d'élites. Méthodologie : Treize nageurs élites ont été analysés sur trois affûtages (T1, N=7 ; T2, N=6 et T3, N=8) qui précèdent trois objectifs nationaux majeurs. Un bioimpédancemètre multifréquence, le Z-Métrix, a été utilisé pour mesurer les indices avant et après l'affûtage. Sur le même principe, les performances des sujets ont été comparées entre la compétition qui suit l'affûtage et une compétition précédente sans affûtage. Pour compléter l'analyse, la charge d'entraînement pendant l'affûtage a été quantifiée puis comparée à la charge qui précède. L'évolution des indices corporels pourra donc être mise en relation avec les différences de performance et la variation de la charge d'entraînement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variety of technologies have been developed to assist decision-making during the management of patients with acute brain injury who require intensive care. A large body of research has been generated describing these various technologies. The Neurocritical Care Society (NCS) in collaboration with the European Society of Intensive Care Medicine (ESICM), the Society for Critical Care Medicine (SCCM), and the Latin America Brain Injury Consortium (LABIC) organized an international, multidisciplinary consensus conference to perform a systematic review of the published literature to help develop evidence-based practice recommendations on bedside physiologic monitoring. This supplement contains a Consensus Summary Statement with recommendations and individual topic reviews on physiologic processes important in the care of acute brain injury. In this article we provide the evidentiary tables for select topics including systemic hemodynamics, intracranial pressure, brain and systemic oxygenation, EEG, brain metabolism, biomarkers, processes of care and monitoring in emerging economies to provide the clinician ready access to evidence that supports recommendations about neuromonitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Careful patient monitoring using a variety of techniques including clinical and laboratory evaluation, bedside physiological monitoring with continuous or non-continuous techniques and imaging is fundamental to the care of patients who require neurocritical care. How best to perform and use bedside monitoring is still being elucidated. To create a basic platform for care and a foundation for further research the Neurocritical Care Society in collaboration with the European Society of Intensive Care Medicine, the Society for Critical Care Medicine and the Latin America Brain Injury Consortium organized an international, multidisciplinary consensus conference to develop recommendations about physiologic bedside monitoring. This supplement contains a Consensus Summary Statement with recommendations and individual topic reviews as a background to the recommendations. In this article, we highlight the recommendations and provide additional conclusions as an aid to the reader and to facilitate bedside care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maintenance of adequate oxygenation is a mainstay of intensive care, however, recommendations on the safety, accuracy, and the potential clinical utility of invasive and non-invasive tools to monitor brain and systemic oxygenation in neurocritical care are lacking. A literature search was conducted for English language articles describing bedside brain and systemic oxygen monitoring in neurocritical care patients from 1980 to August 2013. Imaging techniques e.g., PET are not considered. A total of 281 studies were included, the majority described patients with traumatic brain injury (TBI). All tools for oxygen monitoring are safe. Parenchymal brain oxygen (PbtO2) monitoring is accurate to detect brain hypoxia, and it is recommended to titrate individual targets of cerebral perfusion pressure (CPP), ventilator parameters (PaCO2, PaO2), and transfusion, and to manage intracranial hypertension, in combination with ICP monitoring. SjvO2 is less accurate than PbtO2. Given limited data, NIRS is not recommended at present for adult patients who require neurocritical care. Systemic monitoring of oxygen (PaO2, SaO2, SpO2) and CO2 (PaCO2, end-tidal CO2) is recommended in patients who require neurocritical care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Multimodal monitoring (MMM) is routinely applied in neurointensive care. Unfortunately, there is no robust evidence on which MMM-derived physiologic variables are the most clinically relevant, how and when they should be monitored, and whether MMM impacts outcome. The complexity is even higher because once the data are continuously collected, interpretation and integration of these complex physiologic events into targeted individualized care is still embryonic. RECENT FINDINGS: Recent clinical investigation mainly focused on intracranial pressure, perfusion of the brain, and oxygen availability along with electrophysiology. Moreover, a series of articles reviewing the available evidence on all the MMM tools, giving practical recommendations for bedside MMM, has been published, along with other consensus documents on the role of neuromonitoring and electroencephalography in this setting. SUMMARY: MMM allows comprehensive exploration of the complex pathophysiology of acute brain damage and, depending on the different configuration of the pathological condition we are treating, the application of targeted individualized care. Unfortunately, we still lack robust evidence on how to better integrate MMM-derived information at the bedside to improve patient management. Advanced informatics is promising and may provide us a supportive tool to interpret physiologic events and guide pathophysiological-based therapeutic decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The need to contextualise wastewater-based figures about illicit drug consumption by comparing them with other indicators has been stressed by numerous studies. The objective of the present study was to further investigate the possibility of combining wastewater data to conventional statistics to assess the reliability of the former method and obtain a more balanced picture of illicit drug consumption in the investigated area. METHODS: Wastewater samples were collected between October 2013 and July 2014 in the metropolitan area of Lausanne (226,000 inhabitants), Switzerland. Methadone, its metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), the exclusive metabolite of heroin, 6-monoacetylmorphine (6-MAM), and morphine loads were used to estimate the amounts of methadone and heroin consumed. RESULTS: Methadone consumption estimated from EDDP was in agreement with the expectations. Heroin estimates based on 6-MAM loads were inconsistent. Estimates obtained from morphine loads, combined to prescription/sales data, were in agreement with figures derived from syringe distribution data and general population surveys. CONCLUSIONS: The results obtained for methadone allowed assessing the reliability of the selected sampling strategy, supporting its ability to capture the consumption of a small cohort (i.e., 743 patients). Using morphine as marker, in combination with prescription/sales data, estimates in accordance with other indicators about heroin use were obtained. Combining different sources of data allowed strengthening the results and suggested that the different indicators (i.e., administration route, average dosage and number of consumers) contribute to depict a realistic representation of the phenomenon in the investigated area. Heroin consumption was estimated to approximately 13gday(-1) (118gday(-1) at street level).