370 resultados para pressure equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Little is known on the relative importance of growth at different periods between birth and adolescence on blood pressure (BP). Objective: To assess the association between birth weight, change in body weight (growth) and BP across the entire span of childhood and adolescence. Methods: School-based surveys were conducted annually between 1998 and 2006 among all children in four school grades (kindergarten, 4th, 7th, and 10th year of compulsory school) in the Seychelles, Indian Ocean. Height and weight and BP were measured. Three cohorts of children examined twice were analyzed: 1606 children surveyed at age 5.5 and 9.1, 2557 at age 9.2 and 12.5, and 2065 at age 12.5 and 15.5, respectively. Weights at birth and at one year were extracted from medical files. Weights were expressed as Z-scores and growth was defined as a change in weight Z-scores (corresponding to weight centile crossing). The association between BP (at age 5.5, 9.2, 12.5, and 15.5) and weight at different times was assessed by linear regression. Using results of regression models of BP on all successive weights, life course plots were drawn by plotting regression coefficients against age at which weight was measured. The figure shows a life course plot of systolic BP in boys aged 15.5. Results: Without adjustment for current weight (at the time of BP measurement), birth weight was not associated with current BP, irrespective of age, excepted for girls at age 15.5 for whom a modest positive association was found. When adjusted for current weight, birth weight was negatively and modestly associated with current BP. BP was strongly associated with current weight, irrespective of age. Life course plots showed that BP was strongly associated with growth during the few preceding years but not with growth during earlier years, except for growth during the first year of life which tended to be associated with systolic BP. Conclusions: Our findings suggest that BP during childhood and adolescence is mainly determined by current body weight and recent growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comment on: Cutler JA, Sorlie PD, Wolz M, Thom T, Fields LE, Roccella EJ. Trends in hypertension prevalence, awareness, treatment, and control rates in United States adults between 1988-1994 and 1999-2004. Hypertension. 2008 Nov;52(5):818-27. PMID: 18852389.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac hypertrophy is frequent in chronic hypertension. The renin-angiotensin system, via its effector angiotensin II (Ang II), regulates blood pressure and participates in sustaining hypertension. In addition, a growing body of evidence indicates that Ang II acts also as a growth factor. However, it is still a matter of debate whether the trophic effect of Ang II can trigger cardiac hypertrophy in the absence of elevated blood pressure. To address this question, transgenic mice overexpressing the rat angiotensinogen gene, specifically in the heart, were generated to increase the local activity of the renin-angiotensin system and therefore Ang II production. These mice develop myocardial hypertrophy without signs of fibrosis independently from the presence of hypertension, demonstrating that local Ang II production is important in mediating the hypertrophic response in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé de l'étude. L'application d'une pression positive (PEEP) pendant la phase d'induction d'une anesthésie générale peut prévenir la formation d'atélectasies pulmonaires. Ceci pourrait permettre d'accroître la durée d'apnée non hypoxique par l'augmentation de la capacité pulmonaire résiduelle fonctionnelle (CRF). Nous avons étudié le bénéfice de l'application d'une PEEP durant la phase d'induction d'une anesthésie générale sur la durée d'apnée avant que la saturation périphérique en oxygène atteigne 90%. Quarante patients ASA I-II ont été randomisés en deux groupes distincts. - Dans le groupe PEEP (n=20), les patients ont été pré-oxygénés durant 5 minutes avec une Fi02 à l00% par l'intermédiaire d'un appareil de CPAP (6cmH2O). Après induction de l'anesthésie, les patients furent ventilés mécaniquement (PEEP 6cmH2O) durant 5 minutes supplémentaires. - Dans le groupe ZEEP (n=20), aucune pression positive (ni CPAP, ni PEEP) ne fut utilisée. La durée d'apnée pour atteindre une saturation périphérique de 90% fut mesurée. La durée d'apnée non hypoxique était plus longue dans le groupe PEEP par rapport au groupe ZEEP (599 +/- 135 s vs 470 +/- 150 s, p= 0,007). Nous concluons que l'application d'une pression positive durant la phase d'induction d'une anesthésie générale chez l'adulte prolonge la durée d'apnée non hypoxique de plus de 2 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a prospective investigation of 17 children with severe croup, we analyzed the effect of epinephrine inhalations and mild sedation with chloral hydrate on transcutaneous carbon dioxide pressure (tcPCO2), pulse oximetry measurements, and croup scores. There was a highly significant reduction (p less than 0.001) in the tcPCO2 values and croup scores after inhalation of epinephrine. The changes in the tcPCO2 values correlated with the clinical findings. Mild sedation also significantly improved the croup scores but failed to influence the tcPCO2 values. There was not statistically significant difference in pulse oximetry saturation, fraction of administered oxygen, heart rate, or respiratory rate before and after inhalation of epinephrine or chloral hydrate administration. Monitoring tcPCO2 appears to be a reliable and objective tool for managing patients with upper airway obstruction, whereas croup scores may be misleading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether infusion line compliance contributes to irregular drug delivery during vertical displacement of syringe pumps. DESIGN: Five different commercially available infusion lines were studied at infusion rates of 0.5, 1.0, and 1.5 ml/h. Zero drug delivery time was measured after acute line loop formation (70 cm) using an electronic balance. Compliance of each infusion line was calculated using a pressure transducer and measurement of the occlusion release bolus at 300 mmHg occlusion pressure. Finally, the influence of infusion line compliance on drug delivery during acute lowering of the syringe pump was studied using low- and high-compliance infusion lines. RESULTS: Acute line loop formation resulted in zero drug delivery time from 5.1 +/- 1.5 to 44.0 +/- 6.8 s at flow rates of 0.5 ml/h. Increased flow rates significantly reduced loop-induced flow variability. A close correlation was found between zero drug delivery time and calculated infusion line compliance at 0.5 ml/h (linear regression R2 = 0.79). Lowering of the syringe pump 50 cm prolonged zero drug delivery time from 295.8 +/- 20.7 s with the low-compliance tube to 463.3 +/- 24.0 s with the high-compliance infusion line. CONCLUSIONS: Infusion line compliance contributes to irregular drug delivery associated with vertical displacement of syringe pumps. Siphoning of the infusion line during patient care should be avoided, and flow rates of 1 ml/h or higher are recommended. Low-compliance infusion lines are indicated whenever highly short-acting vasoactive drugs at low delivery rates are administered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The screening of testosterone (T) misuse for doping control is based on the urinary steroid profile, including T, its precursors and metabolites. Modifications of individual levels and ratio between those metabolites are indicators of T misuse. In the context of screening analysis, the most discriminant criterion known to date is based on the T glucuronide (TG) to epitestosterone glucuronide (EG) ratio (TG/EG). Following the World Anti-Doping Agency (WADA) recommendations, there is suspicion of T misuse when the ratio reaches 4 or beyond. While this marker remains very sensitive and specific, it suffers from large inter-individual variability, with important influence of enzyme polymorphisms. Moreover, use of low dose or topical administration forms makes the screening of endogenous steroids difficult while the detection window no longer suits the doping habit. As reference limits are estimated on the basis of population studies, which encompass inter-individual and inter-ethnic variability, new strategies including individual threshold monitoring and alternative biomarkers were proposed to detect T misuse. The purpose of this study was to evaluate the potential of ultra-high pressure liquid chromatography (UHPLC) coupled with a new generation high resolution quadrupole time-of-flight mass spectrometer (QTOF-MS) to investigate the steroid metabolism after transdermal and oral T administration. An approach was developed to quantify 12 targeted urinary steroids as direct glucuro- and sulfo-conjugated metabolites, allowing the conservation of the phase II metabolism information, reflecting genetic and environmental influences. The UHPLC-QTOF-MS(E) platform was applied to clinical study samples from 19 healthy male volunteers, having different genotypes for the UGT2B17 enzyme responsible for the glucuroconjugation of T. Based on reference population ranges, none of the traditional markers of T misuse could detect doping after topical administration of T, while the detection window was short after oral TU ingestion. The detection ability of the 12 targeted steroids was thus evaluated by using individual thresholds following both transdermal and oral administration. Other relevant biomarkers and minor metabolites were studied for complementary information to the steroid profile, including sulfoconjugated analytes and hydroxy forms of glucuroconjugated metabolites. While sulfoconjugated steroids may provide helpful screening information for individuals with homozygotous UGT2B17 deletion, hydroxy-glucuroconjugated analytes could enhance the detection window of oral T undecanoate (TU) doping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Determining a specific death cause may facilitate individualized therapy in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) decreased mortality in the Cardiac Resynchronization in Heart Failure trial by reducing pump failure and sudden cardiac death (SCD). This study analyzes predictors of specific causes of death. METHODS AND RESULTS: Univariate and multivariate analyses used 8 baseline and 3-month post-randomization variables to predict pump failure and SCD (categorized as "definite," "probable," and "possible"). Of 255 deaths, 197 were cardiovascular. There were 71 SCDs with a risk reduction by CRT of 0.47 (95% confidence interval 0.29-0.76; P = .002) with similar reductions in SCD classified as definite, probable, and possible. Univariate SCD predictors were 3-month HF status (mitral regurgitation [MR] severity, plasma brain natriuretic peptide [BNP], end-diastolic volume, and systolic blood pressure), whereas randomization to CRT decreased risk. Multivariate SCD predictors were randomization to CRT 0.56 (0.53-0.96, P = .035) and 3-month MR severity 1.82 (1.77-2.60, P = .0012). Univariate pump failure death predictors related to baseline HF state (quality of life score, interventricular mechanical delay, end-diastolic volume, plasma BNP, MR severity, and systolic pressure), whereas randomization to CRT and nonischemic cardiomyopathy decreased risk; multivariate predictors of pump failure death were baseline plasma BNP and systolic pressure and randomization to CRT. CONCLUSION: CRT decreased SCD in patients with systolic HF and ventricular dyssynchrony. SCD risk was increased with increased severity of MR (including the 3-month value for MR as a time-dependent covariate) and reduced by randomization to CRT. HF death was increased related to the level of systolic blood pressure, log BNP, and randomization to CRT. These results emphasize the importance and interdependence of HF severity to mortality from pump failure and SCD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We assessed the association between birth weight, weight change, and current blood pressure (BP) across the entire age-span of childhood and adolescence in large school-based cohorts in the Seychelles, an island state in the African region. METHODS: Three cohorts were analyzed: 1004 children examined at age 5.5 and 9.1 years, 1886 children at 9.1 and 12.5, and 1575 children at 12.5 and 15.5, respectively. Birth and 1-year anthropometric data were gathered from medical files. The outcome was BP at age 5.5, 9.1, 12.5 or 15.5 years, respectively. Conditional linear regression analysis was used to estimate the relative contribution of changes in weight (expressed in z-score) during different age periods on BP. All analyses were adjusted for height. RESULTS: At all ages, current BP was strongly associated with current weight. Birth weight was not significantly associated with current BP. Upon adjustment for current weight, the association between birth weight and current BP tended to become negative. Conditional linear regression analyses indicated that changes in weight during successive age periods since birth contributed substantially to current BP at all ages. The strength of the association between weight change and current BP increased throughout successive age periods. CONCLUSION: Weight changes during any age period since birth have substantial impact on BP during childhood and adolescence, with BP being more responsive to recent than earlier weight changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.