313 resultados para intraocular prosthesis
Resumo:
Glucocorticoids have been used for decades in the treatment of ocular disorders via topical, periocular, and more recently intravitreal routes. However, their exact mechanisms of action on ocular tissues remain imperfectly understood. Fortunately, two recently approved intravitreal sustained-release drug delivery systems have opened new perspectives for these very potent drugs. To date, among other retinal conditions, their label includes diabetic macular edema, for which a long-lasting therapeutic effect has been demonstrated both morphologically and functionally in several randomized clinical trials. The rate of ocular complications of intravitreal sustained-release steroids, mainly cataract formation and intraocular pressure elevation, is higher than with anti-vascular endothelial growth factor agents. Yet, a better understanding of the mechanisms underlying these adverse effects and the search for the minimal efficient dose should help optimize their therapeutic window.
Resumo:
OBJECTIVES: To learn upon incidence, underlying mechanisms and effectiveness of treatment strategies in patients with central airway and pulmonary parenchymal aorto-bronchial fistulation after thoracic endovascular aortic repair (TEVAR). METHODS: Analysis of an international multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2012 with a total caseload of 4680 TEVAR procedures (14 centres). RESULTS: Twenty-six patients with a median age of 70 years (interquartile range: 60-77) (35% female) were identified. The incidence of either central airway (aorto-bronchial) or pulmonary parenchymal (aorto-pulmonary) fistulation (ABPF) in the entire cohort after TEVAR in the study period was 0.56% (central airway 58%, peripheral parenchymal 42%). Atherosclerotic aneurysm formation was the leading indication for TEVAR in 15 patients (58%). The incidence of primary endoleaks after initial TEVAR was n = 10 (38%), of these 80% were either type I or type III endoleaks. Fourteen patients (54%) developed central left bronchial tree lesions, 11 patients (42%) pulmonary parenchymal lesions and 1 patient (4%) developed a tracheal lesion. The recognized mechanism of ABPF was external compression of the bronchial tree in 13 patients (50%), the majority being due to endoleak formation, further ischaemia due to extensive coverage of bronchial feeding arteries in 3 patients (12%). Inflammation and graft erosion accounted for 4 patients (30%) each. Cumulative survival during the entire study period was 39%. Among deaths, 71% were attributed to ABPF. There was no difference in survival in patients having either central airway or pulmonary parenchymal ABPF (33 vs 45%, log-rank P = 0.55). Survival with a radical surgical approach was significantly better when compared with any other treatment strategy in terms of overall survival (63 vs 32% and 63 vs 21% at 1 and 2 years, respectively), as well as in terms of fistula-related survival (63 vs 43% and 63 vs 43% at 1 and 2 years, respectively). CONCLUSIONS: ABPF is a rare but highly lethal complication after TEVAR. The leading mechanism behind ABPF seems to be a continuing external compression of either the bronchial tree or left upper lobe parenchyma. In this setting, persisting or newly developing endoleak formation seems to play a crucial role. Prognosis does not differ in patients with central airway or pulmonary parenchymal fistulation. Radical bronchial or pulmonary parenchymal repair in combination with stent graft removal and aortic reconstruction seems to be the most durable treatment strategy.
Resumo:
Segment poses and joint kinematics estimated from skin markers are highly affected by soft tissue artifact (STA) and its rigid motion component (STARM). While four marker-clusters could decrease the STA non-rigid motion during gait activity, other data, such as marker location or STARM patterns, would be crucial to compensate for STA in clinical gait analysis. The present study proposed 1) to devise a comprehensive average map illustrating the spatial distribution of STA for the lower limb during treadmill gait and 2) to analyze STARM from four marker-clusters assigned to areas extracted from spatial distribution. All experiments were realized using a stereophotogrammetric system to track the skin markers and a bi-plane fluoroscopic system to track the knee prosthesis. Computation of the spatial distribution of STA was realized on 19 subjects using 80 markers apposed on the lower limb. Three different areas were extracted from the distribution map of the thigh. The marker displacement reached a maximum of 24.9mm and 15.3mm in the proximal areas of thigh and shank, respectively. STARM was larger on thigh than the shank with RMS error in cluster orientations between 1.2° and 8.1°. The translation RMS errors were also large (3.0mm to 16.2mm). No marker-cluster correctly compensated for STARM. However, the coefficient of multiple correlations exhibited excellent scores between skin and bone kinematics, as well as for STARM between subjects. These correlations highlight dependencies between STARM and the kinematic components. This study provides new insights for modeling STARM for gait activity.
Resumo:
The management of primary CNS lymphoma is one of the most controversial topics in neuro-oncology because of the complexity of the disease and the very few controlled studies available. In 2013, the European Association of Neuro-Oncology created a multidisciplinary task force to establish evidence-based guidelines for immunocompetent adults with primary CNS lymphoma. In this Review, we present these guidelines, which provide consensus considerations and recommendations for diagnosis, assessment, staging, and treatment of primary CNS lymphoma. Specifically, we address aspects of care related to surgery, systemic and intrathecal chemotherapy, intensive chemotherapy with autologous stem-cell transplantation, radiotherapy, intraocular manifestations, and management of elderly patients. The guidelines should aid clinicians in their daily practice and decision making, and serve as a basis for future investigations in neuro-oncology.
Resumo:
Different therapeutic options for prosthetic joint infections exist, but surgery remains the key. With a two-stage exchange procedure, a success rate above 90% can be expected. Currently, there is no consensus regarding the optimal duration between explantation and the reimplantation in a two-stage procedure. The aim of this study was to retrospectively compare treatment outcomes between short-interval and long-interval two-stage exchanges. Patients having a two-stage exchange of a hip or knee prosthetic joint infection at Lausanne University Hospital (Switzerland) between 1999 and 2013 were included. The satisfaction of the patient, the function of the articulation and the eradication of infection, were compared between patients having a short (2 to 4 weeks) versus a long (4 weeks and more) interval during a two-stage procedure. Patient satisfaction was defined as good if the patient did not have pain and bad if the patient had pain. Functional outcome was defined good if the patient had a prosthesis in place and could walk, medium if the prosthesis was in place but the patient could not walk, and bad if the prosthesis was no longer in place. Infection outcome was considered good if there had been no re-infection and bad if there had been a re-infection of the prosthesis 145 patients (100 hips, 45 knees) were identified with a median age of 68 years (range 19-103). The median hospital stay was 58 days (range 10-402). The median follow-up was 12.9 months (range 0.5-152). 28 % and 72 % of the patients had a short-interval and long-interval exchange of the prosthesis, respectively. Patient satisfaction, functional outcome and infection outcome for patients having a short versus a long interval are reported in the Table. The patient satisfaction was higher when a long interval was performed whereas the functional and infection outcomes were higher when a short interval was performed. According to this study a short-interval exchange appears preferable to a long interval, especially in the view of treatment effectiveness and functional outcome.
Resumo:
The management of intraocular retinoblastoma is rapidly changing, and even recent reviews on the subject are behind existing practices. The 4 authors of this report collectively represent their management strategies with an emphasis on areas of agreement and disagreement. Ophthalmic artery chemosurgery and intravitreous chemotherapy have completely replaced external beam radiotherapy, reduced the use of systemic chemotherapy, and diminished enucleations by 90% without evidence of compromising patient survival.
Resumo:
Biocompatibility is a requirement for the development of nanofibers for ophthalmic applications. In this study, nanofibers were elaborated using poly(ε-caprolactone) via electrospinning. The ocular biocompatibility of this material was investigated. MIO-M1 and ARPE-19 cell cultures were incubated with nanofibers and cellular responses were monitored by viability and morphology. The in vitro biocompatibility revealed that the nanofibers were not cytotoxic to the ocular cells. These cells exposed to the nanofibers proliferated and formed an organized monolayer. ARPE-19 and MIO-M1 cells were capable of expressing GFAP, respectively, demonstrating their functionality. Nanofibers were inserted into the vitreous cavity of the rat's eye for 10days and the in vivo biocompatibility was investigated using Optical Coherence Tomography (OCT), histology and measuring the expression of pro-inflammatory genes (IL-1β, TNF-α, VEGF and iNOS) (real-time PCR). The OCT and the histological analyzes exhibited the preserved architecture of the tissues of the eye. The biomaterial did not elicit an inflammatory reaction and pro-inflammatory cytokines were not expressed by the retinal cells, and the other posterior tissues of the eye. Results from the biocompatibility studies indicated that the nanofibers exhibited a high degree of cellular biocompatibility and short-term intraocular tolerance, indicating that they might be applied as drug carrier for ophthalmic use.
Resumo:
Aims: To evaluate the effectiveness and safety of Posterior Sub-Tenon (PST) Triamcinolone Acetonide (TA) injection for persistent macular oedema associated with non-ischemic Central Retinal Vein Occlusion (CRVO) or Branch Retinal Vein Occlusion (BRVO) in non-vitrectomized eye. Methods: Fourteen consecutive eyes of 14 patients characterized by macular oedema lasting more than 3 months and with a visual acuity of less than 20/40 were enrolled. Six eyes presented with BRVO, 8 eyes with CRVO. PST injection of 40 mg TA was performed in topical anaesthesia. All patients were phakic, and followed for at least 6 months. Snellen visual acuity converted to LogMAR units and anatomic responses were evaluated before, and at 1, 3, 6, and 12 (if required) months after injections and re-injection considered. Results: In the BRVO group, mean foveal thickness was 548.2±49.50 μm preoperatively, and 452.8±56.2 μm and 280.8±62.5 μm at 1 and 12 month follow-up, respectively. Statistical analysis showed significant differences between preoperative and postoperative measurements (P<.05, paired t test) 3 months after injections. Improvement of visual acuity by at least 0.2 LogMAR was seen in 3(50%) of the 6 eyes. No re-injection was needed. In the CRVO group, mean foveal thickness was 543.7±34.4 μm preoperatively, and 283.0±29.0 μm and 234.8±23.6 μm at 1 and 12 month follow-up, respectively. Statistical analysis showed significant differences between preoperative and postoperative measurements (P<.05, paired t test). Improvement of visual acuity by at least 0.2 LogMAR was seen in 7 eyes (88%). Mean number of re-injection was of 2.1±0.3. Intraocular pressure elevation of 22 mm Hg or higher was found in 2/14 eyes (14%). Cataract progression was noted in 5/14 eyes (36%). Conclusions: PST injection of TA appears to be as safe and effective treatment for chronic macular oedema associated due to both non-ischemic BRVO or CRVO, with a better efficacy in BRVO.
Resumo:
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.
Resumo:
Aortic root (AoR) components provide synchronous and precise 3D deformation of the aortic root during the cardiac cycle in order to ensure closure and opening of the three leaflets over a lifetime. Any deviation from the natural 3D morphology, such as with AoR annulus dilatation, enlarged sinuses and/or dilatation of the sinotubular junction, as in the case of ascending aortic dilatation, may result in disruption of the natural AoR function. Surgical treatment of AoR pathology has two modalities: the replacement of the aortic valve by artificial prosthesis or by preservation of the three leaflets and reconstruction of the aortic root components. Currently, there are two basic aortic root reconstruction procedures: aortic root sparing and aortic valve reimplantation techniques. Regardless of the technique used, the restoration of adequate cusp coaptation, is from a technical point of view, the most important element to consider. To achieve this, there are two requirements that need to be met: (i) the valve coaptation should be superior to the level of the aortic root base by at least 8 mm and (ii) the coaptation height per se has to be ≥5 mm. Successful restoration of the aortic root requires adequate technical skills, detailed knowledge of aortic root anatomy and topography, and also knowledge of the spatial pattern of AoR elements. Recently, there has been growing interest in aortic root reconstructive procedures as well their modifications. As such, the aim of this review is to analyse aortic root topography and 3D anatomy from a surgical point of view. The review also focuses on potential risk regions that one should be aware of before the surgical journey into the 'deep waters area' of the AoR begins.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
We report a case of ascending aortic graft infection by an atypical bacteria, Mycoplasma hominis, with mediastinitis, a dreaded complication after cardiac surgery. A 55-year-old patient underwent ascending aorta replacement for acute type A dissection. He developed sternal instability and purulent discharge, requiring sternal wire removal and debridement. Cultures were initially sterile, but showed M. hominis infection after a significant delay and in specific culture media. The patient was treated with doxycycline and moxifloxacine. Cultures became negative and the sternum was closed on the 28th postoperative day after the first debridement. Recovery was favorable, with no signs of infection. Antibiotics were continued for one year. The patient is still asymptomatic 16 months after antibiotic interruption. Atypical organisms should be considered in the differential diagnosis of acute mediastinitis of unknown etiology after routine microbiological investigations.
Resumo:
Since routine eubacterial 16S rRNA PCR does not amplify members of the Chlamydiales order, we tested all samples received in our laboratory during a 10 months period using a pan-Chlamydiales real-time PCR. 3 of 107 samples (2.8%) revealed to be positive, suggesting a role of some Chlamydiales in the pathogenesis of chronic bronchial stenosis or bronchial stenosis superinfection and as agents of orthopaedic prosthesis infections.