350 resultados para Budget Pressure
Resumo:
Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.
Resumo:
The Manival near Grenoble (French Prealps) is a very active debris-flow torrent equipped with a large sediment trap (25 000 m3) protecting an urbanized alluvial fan from debris-flows. We began monitoring the sediment budget of the catchment controlled by the trap in Spring 2009. Terrestrial laser scanner is used for monitoring topographic changes in a small gully, the main channel, and the sediment trap. In the main channel, 39 cross-sections are surveyed after every event. Three periods of intense geomorphic activity are documented here. The first was induced by a convective storm in August 2009 which triggered a debris-flow that deposited ~1,800 m3 of sediment in the trap. The debris-flow originated in the upper reach of the main channel and our observations showed that sediment outputs were entirely supplied by channel scouring. Hillslope debris-flows were initiated on talus slopes, as revealed by terrestrial LiDAR resurveys; however they were disconnected to the main channel. The second and third periods of geomorphic activity were induced by long duration and low intensity rainfall events in September and October 2009 which generate small flow events with intense bedload transport. These events contribute to recharge the debris-flow channel with sediments by depositing important gravel dunes propagating from headwaters. The total recharge in the torrent subsequent to bedload transport events was estimated at 34% of the sediment erosion induced by the August debris-flow.
Resumo:
OBJECTIVES: To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN: Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING: The study was performed in a PICU. PATIENTS: From 4 weeks to 5 years. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support (PS), three levels of expiratory trigger (ETS) setting were compared: initial ETS (PSinit), and ETS value decreased and increased by 15%. Of the three sessions, the period allowing for the lowest number of asynchrony events was defined as PSbest. Neurally adjusted ventilator assist level was adjusted to match the maximum airway pressure during PSinit. Positive end-expiratory pressure was the same during pressure support and neurally adjusted ventilator assist. Asynchrony events, trigger delay, and cycling-off delay were quantified for each period. RESULTS: Six infants and children were studied. Trigger delay was lower with neurally adjusted ventilator assist versus PSinit and PSbest (61 ms [56-79] vs 149 ms [134-180] and 146 ms [101-162]; p = 0.001 and 0.02, respectively). Inspiratory time in excess showed a trend to be shorter during pressure support versus neurally adjusted ventilator assist. Main asynchrony events during PSinit were autotriggering (4.8/min [1.7-12]), ineffective efforts (9.9/min [1.7-18]), and premature cycling (6.3/min [3.2-18.7]). Premature cycling (3.4/min [1.1-7.7]) was less frequent during PSbest versus PSinit (p = 0.059). The asynchrony index was significantly lower during PSbest versus PSinit (40% [28-65] vs 65.5% [42-76], p < 0.001). With neurally adjusted ventilator assist, all types of asynchronies except double triggering were reduced. The asynchrony index was lower with neurally adjusted ventilator assist (2.3% [0.7-5] vs PSinit and PSbest, p < 0.05 for both comparisons). CONCLUSION: Asynchrony events are frequent during noninvasive ventilation with pressure support in infants and in children despite adjusting the cycling-off criterion. Compared with pressure support, neurally adjusted ventilator assist allows improving patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events. Further studies should determine the clinical impact of these findings.
Resumo:
Short-term exposure to ambient particulate matter with aerodynamic diameters<10 µm were found to be positively associated with blood pressure. Yet, little information exists regarding the association between particles and circadian rhythm of blood pressure. Hence, we analyzed the association of exposure to particulate matter with aerodynamic diameters<10 µm on the day of examination and ≤7 days before with ambulatory blood pressure and with sodium excretion in 359 adults from the general population using multiple linear regression. After controlling for potential confounders, a 10-µg/m3 increase in particulate matter with aerodynamic diameters<10 µm levels was associated with nighttime systolic blood pressure (β=1.32 mm Hg 95% CI, 0.06-2.58 mm Hg at lag 0; P=0.04), nighttime diastolic blood pressure (0.72 mm Hg 95% CI, 0.03-1.42 mm Hg at lag 2; P=0.04), nocturnal systolic blood pressure dipping (-0.96 mm Hg 95% CI, -1.89 to -0.03 mm Hg at lag 0; P=0.044), and daytime urinary sodium excretion (-0.05 log-mmol/min 95% CI, -0.10 to -0.01 log-mmol/min at lag 0; P=0.027) but not with nighttime sodium excretion. The associations with blood pressure rapidly diminished with increasing lag days, and the associations with daytime sodium excretion were maximal with particulate matter with aerodynamic diameters<10 µm in exposures 2 to 5 days before. The associations of short-term increases in particulate matter with aerodynamic diameters<10 µm with higher nighttime blood pressure and blunted systolic blood pressure dipping were preceded by associations with reduced ability of the kidney to excrete sodium during daytime. The underlying mechanism linking air pollution to increased cardiovascular risk may include disturbed circadian rhythms of renal sodium handling and blood pressure.
Resumo:
The antihypertensive effects of the beta-blocking agent betaxolol and the calcium entry blocker verapamil were compared in a crossover single-blind trial. Seventeen patients with uncomplicated essential hypertension took either betaxolol or a slow-release formulation of verapamil for two consecutive 6-week periods. The sequence of treatment phases was randomly allocated and a 2-week washout period preceded each treatment. The antihypertensive effect of the test drugs was assessed both at the physician's office and during everyday activities using a portable blood pressure recorder. The crossover design of the trial made it possible to evaluate the antihypertensive efficacy of betaxolol and verapamil both in the group as a whole and in the individual patient. The individual patient response to one of these agents was not a reliable indicator of the same patient's response to the alternative agent. Betaxolol brought both office and ambulatory recorded blood pressures under control in a larger fraction of patients than verapamil, although the magnitude of the blood pressure fall in the responders was equal for each drug. These observations stress the need for an individualized approach to the evaluation of antihypertensive therapy. The present results also demonstrate that optimal antihypertensive therapy is still a matter of trial and error. The precise methodology that ought to characterize crossover trials may make it possible to improve the therapeutic approach to hypertensive patients.
Resumo:
Left ventricular hypertrophy (LVH) is due to pressure overload or mechanical stretch and is thought to be associated with remodeling of gap-junctions. We investigated whether the expression of connexin 43 (Cx43) is altered in humans in response to different degrees of LVH. The expression of Cx43 was analyzed by quantitative polymerase chain reaction, Western blot analysis and immunohistochemistry on left ventricular biopsies from patients undergoing aortic or mitral valve replacement. Three groups were analyzed: patients with aortic stenosis with severe LVH (n=9) versus only mild LVH (n=7), and patients with LVH caused by mitral regurgitation (n=5). Cx43 mRNA expression and protein expression were similar in the three groups studied. Furthermore, immunohistochemistry revealed no change in Cx43 distribution. We can conclude that when compared with mild LVH or with LVH due to volume overload, severe LVH due to chronic pressure overload is not accompanied by detectable changes of Cx43 expression or spatial distribution.
Resumo:
1st day: Lithology and structure of the northern Adula nappe around Zervreila 2nd day: High-pressure rocks of the Suretta nappe, the middle Adula nappe and its Mesozoic cover - Eclogite near Innerferrara, Suretta nappe - Crossite-bearing prasinite from schistes lustres near Nufenen - Eclogites south of Hinterrhein, Adula nappe - Blueschists and eclogites from Neu-Wahli, Misox zone 3 days: Eclogite boudin and associated whiteschists in the uppermost Calanca valley, middle Adula nappe 4th day: Eclogites, associated metapelites and granitoid gneisses of Trescolmen, middle Adula nappe 5th day: The ultramafic-mafic suite of the Cima Lunga nappe around Cima di Gagnone 6th day: Garnet peridotites and eclogites from Alpe Arami, Cima Lunga nappe
Resumo:
OBJECTIVE: Body composition measured by dual-energy X-ray absorptiometry (DXA) is believed to be superior to crude measures such as BMI or waist circumference (WC) to assess health risks associated with adiposity in adults. We compared the ability of BMI, WC, waist-to-height ratio (WHtR), percentage body fat from skinfold thickness, and measures of total and central fat assessed by DXA to identify children with elevated blood pressure (BP). STUDY DESIGN: The QUALITY Study follows 630 Caucasian families (father, mother, and child originally aged 8-10 years). BP, height, weight, WC, and skinfold thickness were measured according to standardized protocols. Elevated BP was defined as systolic or diastolic BP at least 90th age, sex, and height-specific percentile. Total and central fat were determined with DXA. The area under the receiver operating characteristic (ROC) curve (AUC) statistic was computed from logistic models that adjusted for age, sex, height, Tanner stage, and physical activity. RESULTS: All adiposity indicators were highly correlated. WC and WHtR did not show superior ability over BMI to identify children with elevated SBP (P = 0.421 and 0.473). Measures of total and central fat from DXA did not show an improved ability over BMI or WC to identify children with elevated SBP (P = 0.325-0.662). CONCLUSION: Results support the use of BMI in clinical and public health settings, at least in this age group. As all indicators had a limited ability to identify children with elevated BP, results also support measurement of BP in all children of this age independent of a weight status.
Resumo:
Steep mountain catchments typically experience large sediment pulses from hillslopes which are stored in headwater channels and remobilized by debris-flows or bedload transport. Event-based sediment budget monitoring in the active Manival debris-flow torrent in the French Alps during a two-year period gave insights into the catchment-scale sediment routing during moderate rainfall intensities which occur several times each year. The monitoring was based on intensive topographic resurveys of low- and high-order channels using different techniques (cross-section surveys with total station and high-resolution channel surveys with terrestrial and airborne laser scanning). Data on sediment output volumes from the main channel were obtained by a sediment trap. Two debris-flows were observed, as well as several bedload transport flow events. Sediment budget analysis of the two debris-flows revealed that most of the debris-flow volumes were supplied by channel scouring (more than 92%). Bedload transport during autumn contributed to the sediment recharge of high-order channels by the deposition of large gravel wedges. This process is recognized as being fundamental for debris-flow occurrence during the subsequent spring and summer. A time shift of scour-and-fill sequences was observed between low- and high-order channels, revealing the discontinuous sediment transfer in the catchment during common flow events. A conceptual model of sediment routing for different event magnitude is proposed.
Resumo:
Continuous positive airway pressure, aimed at preventing pulmonary atelectasis, has been used for decades to reduce lung injury in critically ill patients. In neonatal practice, it is increasingly used worldwide as a primary form of respiratory support due to its low cost and because it reduces the need for endotracheal intubation and conventional mechanical ventilation. We studied the anesthetized in vivo rat and determined the optimal circuit design for delivery of continuous positive airway pressure. We investigated the effects of continuous positive airway pressure following lipopolysaccharide administration in the anesthetized rat. Whereas neither continuous positive airway pressure nor lipopolysaccharide alone caused lung injury, continuous positive airway pressure applied following intravenous lipopolysaccharide resulted in increased microvascular permeability, elevated cytokine protein and mRNA production, and impaired static compliance. A dose-response relationship was demonstrated whereby higher levels of continuous positive airway pressure (up to 6 cmH(2)O) caused greater lung injury. Lung injury was attenuated by pretreatment with dexamethasone. These data demonstrate that despite optimal circuit design, continuous positive airway pressure causes significant lung injury (proportional to the airway pressure) in the setting of circulating lipopolysaccharide. Although we would currently avoid direct extrapolation of these findings to clinical practice, we believe that in the context of increasing clinical use, these data are grounds for concern and warrant further investigation.
Resumo:
Objective: Respiratory assistance with nasal continuous positive airway pressure (n-CPAP) is an effective treatment in premature newborns presenting respiratory distress. The aim of the study was to depict cardiac function, systemic (Qs) and pulmonary output (Qp) by echocardiography in stable premature infants requiring prolonged n-CPAP. Our hypothesis was that n-CPAP could reduce pulmonary blood flow. Patients and methods: All premature infants < 32 weeks gestation, > 7 days-old, requiring n-CPAP without severe respiratory compromise nor need for additional oxygen were prospectively included. Every patient had a first echocardiography while on n-CPAP. N-CPAP was then discontinued for two hours and a second echocardiography was performed. Results: 17 premature infants were included. Mean gestational age was 28 ± 2 weeks and mean weight 1.1 ± 0.3 kg. Following retrieval of n-CPAP we observed an increase in Qp of 53 ml/kg/min (95% CI 19-87 ml/kg/min), but no significant change in Qs. Consecutively a significant increase in Qp/Qs ratio of 16% was found (95% CI 7-29%). Conclusions: Nasal continuous positive airway pressure has hemodynamic effects in preterm infants in stable pulmonary and cardiac conditions. It reduces pulmonary output without interference with systemic output.
Resumo:
To study the role of early energetic abnormalities in the subsequent development of heart failure, we performed serial in vivo combined magnetic resonance imaging (MRI) and (31)P magnetic resonance spectroscopy (MRS) studies in mice that underwent pressure-overload following transverse aorta constriction (TAC). After 3 wk of TAC, a significant increase in left ventricular (LV) mass (74 +/- 4 vs. 140 +/- 26 mg, control vs. TAC, respectively; P < 0.000005), size [end-diastolic volume (EDV): 48 +/- 3 vs. 61 +/- 8 microl; P < 0.005], and contractile dysfunction [ejection fraction (EF): 62 +/- 4 vs. 38 +/- 10%; P < 0.000005] was observed, as well as depressed cardiac energetics (PCr/ATP: 2.0 +/- 0.1 vs. 1.3 +/- 0.4, P < 0.0005) measured by combined MRI/MRS. After an additional 3 wk, LV mass (140 +/- 26 vs. 167 +/- 36 mg; P < 0.01) and cavity size (EDV: 61 +/- 8 vs. 76 +/- 8 microl; P < 0.001) increased further, but there was no additional decline in PCr/ATP or EF. Cardiac PCr/ATP correlated inversely with end-systolic volume and directly with EF at 6 wk but not at 3 wk, suggesting a role of sustained energetic abnormalities in evolving chamber dysfunction and remodeling. Indeed, reduced cardiac PCr/ATP observed at 3 wk strongly correlated with changes in EDV that developed over the ensuing 3 wk. These data suggest that abnormal energetics due to pressure overload predict subsequent LV remodeling and dysfunction.