309 resultados para percutaneous transluminal coronary angioplasty
Resumo:
The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).
Resumo:
BACKGROUND: The relationship between coronary endothelial function and coronary calcification is not well established. METHODS: Forty-six patients 17 men [37%]; age, 47.4+/-11.4 years prospectively underwent testing for coronary endothelial function and measurement of coronary artery calcification (CAC). RESULTS: Log CAC scores were not significantly different between patients with normal (n=31) and abnormal (n=15) response of epicardial coronary artery diameter to acetylcholine (%CAD(Ach)) (median (25, 75 percentile) 1.1 (0.0, 3.7) vs. 0.3 (0.0, 2.4), P=.32) and with normal (n=28) and abnormal (n=18) response of coronary blood flow to acetylcholine (%CBF(Ach)) (0.5 (0.0, 3.6) vs. 0.5 (0.0, 3.2), P=.76). Log CAC scores did not correlate with %CAD(Ach) (r=0.08, P=.59), %CBF(Ach) (r=0.14, P=.35). CONCLUSIONS: In patients without significant coronary artery disease, coronary endothelial dysfunction showed no apparent association with coronary calcification. Our findings suggest that these 2 markers may represent separate, independent processes in the progression of coronary atherosclerosis.
Resumo:
Our aim was to assess the clinical outcome of patients who were subjected to long-axis sacroplasty for the treatment of sacral insufficiency fractures. Nineteen patients with unilateral (n = 3) or bilateral (n = 16) sacral fractures were involved. Under local anaesthesia, each patient was subjected to CT-guided sacroplasty using the long-axis approach through a single entry point. An average of 6 ml of polymethylmethacrylate (PMMA) was delivered along the path of each sacral fracture. For each individual patient, the Visual Analogue pain Scale (VAS) before sacroplasty and at 1, 4, 24 and 48 weeks after the procedure was obtained. Furthermore, the use of analgesics (narcotic/non-narcotic) along with the evolution of post-interventional patient mobility before and after sacroplasty was also recorded. The mean pre-procedure VAS was 8 +/- 1.9 (range, 2 to 10). This rapidly and significantly (P < 0.001) declined in the first week after the procedure (mean 4 +/- 1.4; range, 1 to 7) followed by a gradual and significant (P < 0.001) decrease along the rest of the follow-up period at 4 weeks (mean 3 +/- 1.1; range, 1 to 5), 24 weeks (mean 2.2 +/- 1.1; range, 1 to 5) and 48 weeks (mean 1.6 +/- 1.1; range, 1 to 5). Eleven (58%) patients were under narcotic analgesia before sacroplasty, whereas 8 (42%) patients were using non-narcotics. Corresponding values after the procedure were 2/19 (10%; narcotic, one of them was on reserve) and 10/19 (53%; non-narcotic). The remaining 7 (37%) patients did not address post-procedure analgesic use. The evolution of post-interventional mobility was favourable in the study group as they revealed a significant improvement in their mobility point scale (P < 0.001). Long-axis percutaneous sacroplasty is a suitable, minimally invasive treatment option for patients who present with sacral insufficiency fractures. More studies with larger patient numbers are needed to explore any unrecognised limitations of this therapeutic approach.
Resumo:
Transapical aortic valve implantation is indicated in high-risk patients with aortic stenosis and peripheral vascular disease requiring aortic valve replacement. Minimally invasive direct coronary artery bypass grafting is also a valid, minimally invasive option for myocardial revascularization in patients with critical stenosis on the anterior descending coronary artery. Both procedures are performed through a left minithoracotomy, without cardiopulmonary bypass, aortic cross-clamping, and cardioplegic arrest. We describe a successful combined transapical aortic valve implantation and minimally invasive direct coronary bypass in a high-risk patient with left anterior descending coronary artery occlusion and severe aortic valve stenosis.
Resumo:
BACKGROUND: The optimal strategy for percutaneous coronary intervention (PCI) of ST-segment elevation myocardial infarction (STEMI) in multi-vessel disease (MVD), i.e., multi-vessel PCI (MV-PCI) vs. PCI of the infarct-related artery only (IRA-PCI), still remains unknown. METHODS: Patients of the AMIS Plus registry admitted with an acute coronary syndrome were contacted after a median of 378 days (interquartile range 371-409). The primary end-point was all-cause death. The secondary end-point included all major adverse cardiovascular and cerebrovascular events (MACCE) including death, re-infarction, re-hospitalization for cardiac causes, any cardiac re-intervention, and stroke. RESULTS: Between 2005 and 2012, 8330 STEMI patients were identified, of whom 1909 (24%) had MVD. Of these, 442 (23%) received MV-PCI and 1467 (77%) IRA-PCI. While all-cause mortality was similar in both groups (2.7% both, p>0.99), MACCE was significantly lower after MV-PCI vs. IRA-PCI (15.6% vs. 20.0%, p=0.038), mainly driven by lower rates of cardiac re-hospitalization and cardiac re-intervention. Patients undergoing MV-PCI with drug-eluting stents had lower rates of all-cause mortality (2.1% vs. 7.4%, p=0.026) and MACCE (14.1% vs. 25.9%, p=0.042) compared with those receiving bare metal stents (BMS). In multivariate analysis, MV-PCI (odds ratio, OR 0.69, 95% CI 0.51-0.93, p=0.017) and comorbidities (Charlson index ≥ 2; OR 1.42, 95% CI 1.05-1.92, p=0.025) were independent predictors for 1-year MACCE. CONCLUSION: In an unselected nationwide real-world cohort, an approach using immediate complete revascularization may be beneficial in STEMI patients with MVD regarding MACCE, specifically when drug-eluting stents are used, but not regarding mortality. This has to be tested in a randomized controlled trial.
Resumo:
PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P < 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P < 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P < 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.
Resumo:
BACKGROUND: The Marburg Heart Score (MHS) aims to assist GPs in safely ruling out coronary heart disease (CHD) in patients presenting with chest pain, and to guide management decisions. AIM: To investigate the diagnostic accuracy of the MHS in an independent sample and to evaluate the generalisability to new patients. DESIGN AND SETTING: Cross-sectional diagnostic study with delayed-type reference standard in general practice in Hesse, Germany. METHOD: Fifty-six German GPs recruited 844 males and females aged ≥ 35 years, presenting between July 2009 and February 2010 with chest pain. Baseline data included the items of the MHS. Data on the subsequent course of chest pain, investigations, hospitalisations, and medication were collected over 6 months and were reviewed by an independent expert panel. CHD was the reference condition. Measures of diagnostic accuracy included the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, likelihood ratios, and predictive values. RESULTS: The AUC was 0.84 (95% confidence interval [CI] = 0.80 to 0.88). For a cut-off value of 3, the MHS showed a sensitivity of 89.1% (95% CI = 81.1% to 94.0%), a specificity of 63.5% (95% CI = 60.0% to 66.9%), a positive predictive value of 23.3% (95% CI = 19.2% to 28.0%), and a negative predictive value of 97.9% (95% CI = 96.2% to 98.9%). CONCLUSION: Considering the diagnostic accuracy of the MHS, its generalisability, and ease of application, its use in clinical practice is recommended.
Resumo:
BACKGROUND: In patients with Kawasaki disease, serial evaluation of the distribution and size of coronary artery aneurysms (CAA) is necessary for risk stratification and therapeutic management. Although transthoracic echocardiography is often sufficient for this purpose initially, visualization of the coronary arteries becomes progressively more difficult as children grow. We sought to prospectively compare coronary magnetic resonance angiography (MRA) and x-ray coronary angiography findings in patients with CAA caused by Kawasaki disease. METHODS AND RESULTS: Six subjects (age 10 to 25 years) with known CAA from Kawasaki disease underwent coronary MRA using a free-breathing T2-prepared 3D bright blood segmented k-space gradient echo sequence with navigator gating and tracking. All patients underwent x-ray coronary angiography within a median of 75 days (range, 1 to 359 days) of coronary MRA. There was complete agreement between MRA and x-ray angiography in the detection of CAA (n=11), coronary artery stenoses (n=2), and coronary occlusions (n=2). Excellent agreement was found between the 2 techniques for detection of CAA maximal diameter (mean difference=0.4 +/- 0.6 mm) and length (mean difference=1.4 +/- 1.6 mm). The 2 methods showed very similar results for proximal coronary artery diameter (mean difference=0.2 +/- 0.5 mm) and CAA distance from the ostia (mean difference=0.1 +/- 1.5 mm). CONCLUSION: Free-breathing 3D coronary MRA accurately defines CAA in patients with Kawasaki disease. This technique may provide a non-invasive alternative when transthoracic echocardiography image quality is insufficient, thereby reducing the need for serial x-ray coronary angiography in this patient group.
Resumo:
The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.
Resumo:
During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.
Resumo:
The aim of this study was to review our experience in percutaneous endoscopic gastrostomy (PEG) performed in patients with cancer of the upper aerodigestive tract. Descriptive retrospective study of 142 patients (115 males, 27 females), mean age 62.4 years (25-84 years), with head and neck or esophageal cancer, who underwent PEG tube insertion between January 2006 and December 2008. The studied parameters were indications, success rate, rate and type of complications, and their management. Percutaneous endoscopic gastrostomy was inserted before chemoradiation therapy in 80% and during or after cancer treatment in 20% of the patients. PEG placement was possible in 137 patients (96%). Major complications were observed in 9 (7%) and minor complications in 22 (17%) of the 137 patients. Seven of the 9 patients with a major complication needed revision surgery. The mortality directly related to the procedure was 0.7%. Percutaneous endoscopic gastrostomy tube insertion has a high success rate. In patients with upper aerodigestive tract cancer, PEG should be the first choice for enteral nutrition when sufficient oral intake is not possible. Although apparently easy, the procedure may occasionally lead to severe complications. Therefore, a strict technique and knowledge of clinical signs of possible complications are mandatory.