289 resultados para Wayfaring life.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Previous studies revealed that acute depressive episodes are associated with both cognitive deficits and modified personality patterns in late life. Whether or not these psychological changes are present after remission remains a matter of debate. To date, no study provided concomitant assessment of cognition and psychological functions in this particular clinical setting. METHOD: Using a cross-sectional design, 58 remitted outpatients (36 with unipolar early-onset depression (EOD) and 22 with bipolar disorder (BD)) were compared to 62 healthy controls. Assessment included detailed neurocognitive measures and evaluation of the five factor personality dimensions (NEO-Personality Inventory). RESULTS: Group comparisons revealed significant slower processing speed, working and episodic memory performances in BD patients. EOD patients showed cognitive abilities comparable to those of elderly controls. In NEO PI assessment, both BD and EOD patients displayed higher Depressiveness facet scores. In addition, the EOD but not BD group had lower Extraversion factor, and Warmth and Positive Emotion facet scores than controls. CONCLUSIONS: After remission from acute affective symptoms, older BD patients show significant impairment in several cognitive functions while neuropsychological performances remained intact in elderly patients with EOD. Supporting a long-lasting psychological vulnerability, EOD patients are more prone to develop emotion-related personality trait changes than BD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recently, a compact cardiopulmonary support (CPS) system designed for quick set-up for example, during emergency cannulation, has been introduced. Traditional rectilinear percutaneous cannulas are standard for remote vascular access with the original design. The present study was designed to assess the potential of performance increase by the introduction of next-generation, self-expanding venous cannulas, which can take advantage of the luminal width of the venous vasculature despite a relatively small access orifice. METHODS: Veno-arterial bypass was established in three bovine experiments (69+/-10 kg). The Lifebridge (Lifebridge GmbH, Munich, Germany) system was connected to the right atrium in a trans-jugular fashion with various venous cannulas; and the oxygenated blood was returned through the carotid artery with a 17 F percutaneous cannula. Two different venous cannulas were studied, and the correlation between the centrifugal pump speed (1500-3900 RPM), flow and the required negative pressure on the venous side was established: (A) Biomedicus 19 F (Medtronic, Tolochenaz, Switzerland); (B) Smart canula 18 F/36 F (Smartcanula LLC, Lausanne, Switzerland). RESULTS: At 1500 RPM, the blood flow was 0.44+/-0.26 l min(-1) for the 19 F rectilinear cannula versus 0.73+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 2500 RPM the blood flow was 1.63+/-0.62 l min(-1) for the 19F rectilinear cannula versus 2.13+/-0.34 l min(-1) for the 18/36 F self-expanding cannula. At 3500 RPM, the blood flow was 2.78+/-0.47 l min(-1) for the 19 F rectilinear cannula versus 3.64+/-0.39 l min(-1) for the 18/36 F self-expanding cannula (p<0.01 for 18/36 F vs 19 F). At 1500 RPM, the venous line pressure was 18+/-8 mmHg for the 19F rectilinear cannula versus 19+/-5 mmHg for the 18/36 F self-expanding cannula. At 2500 RPM the venous line pressure accounted for -22+/-32 mmHg for the 19 F rectilinear cannula versus 2+/-5 mmHg for the 18/36 F self-expanding cannula. At 3500 RPM, the venous line pressure was -112+/-42 mmHg for the rectilinear cannula versus 28+/-7 mmHg for the 18/36 F self-expanding cannula (p<0.01 for 18 F/36 F vs 19 F). Conclusions: The negative pressure required to achieve adequate venous drainage with the self-expanding venous cannula accounts for approximately 31% of the pressure necessary with the 19 F rectilinear cannula. In addition, a pump flow of more than 4 l min(-1) can be achieved with the self-expanding design and a well-accepted negative inlet pressure for minimal blood trauma of less than 50 mmHg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: THC-COOH has been proposed as a criterion to help to distinguish between occasional from regular cannabis users. However, to date this indicator has not been adequately assessed under experimental and real-life conditions. Methods: We carried out a controlled administration study of smoked cannabis with a placebo. Twenty-three heavy smokers and 25 occasional smokers, between 18 and 30 years of age, participated in this study [Battistella G et al., PloS one. 2013;8(1):e52545]. We collected data from a second real case study performed with 146 traffic offenders' cases in which the whole blood cannabinoid concentrations and the frequency of cannabis use were known. Cannabinoid levels were determined in whole blood using tandem mass spectrometry methods. Results: Significantly high differences in THC-COOH concentrations were found between the two groups when measured during the screening visit, prior to the smoking session, and throughout the day of the experiment. Receiver operating characteristic (ROC) curves were determined and two threshold criteria were proposed in order to distinguish between these groups: a free THC-COOH concentration below 3 μg/L suggested an occasional consumption (≤ 1 joint/week) while a concentration higher than 40 μg/L corresponded to a heavy use (≥ 10 joints/month). These thresholds were successfully tested with the second real case study. The two thresholds were not challenged by the presence of ethanol (40% of cases) and of other therapeutic and illegal drugs (24%). These thresholds were also found to be consistent with previously published experimental data. Conclusion: We propose the following procedure that can be very useful in the Swiss context but also in other countries with similar traffic policies: If the whole blood THC-COOH concentration is higher than 40 μg/L, traffic offenders must be directed first and foremost toward medical assessment of their fitness to drive. This evaluation is not recommended if the THC-COOH concentration is lower than 3 μg/L. A THC-COOH level between these two thresholds can't be reliably interpreted. In such a case, further medical assessment and follow up of the fitness to drive are also suggested, but with lower priority.