302 resultados para ULTRAFAST COMPUTED-TOMOGRAPHY
Resumo:
UNLABELLED: Bone microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) was assessed in adult patients with mild, moderate, and severe osteogenesis imperfecta (OI). The trabecular bone score (TBS), bone mineral density (BMD) by dual-energy X-ray absorptiometry (DXA), and dual X-ray and laser (DXL) at the calcaneus were likewise assessed in patients with OI. Trabecular microstructure and BMD in particular were severely altered in patients with OI. INTRODUCTION: OI is characterized by high fracture risk but not necessarily by low BMD. The main purpose of this study was to assess bone microarchitecture and BMD at different skeletal sites in different types of OI. METHODS: HR-pQCT was performed in 30 patients with OI (mild OI-I, n = 18 (41.8 [34.7, 55.7] years) and moderate to severe OI-III-IV, n = 12 (47.6 [35.3, 58.4] years)) and 30 healthy age-matched controls. TBS, BMD by DXA at the lumbar spine and hip, as well as BMD by DXL at the calcaneus were likewise assessed in patients with OI only. RESULTS: At the radius, significantly lower trabecular parameters including BV/TV (p = 0.01 and p < 0.0001, respectively) and trabecular number (p < 0.0001 and p < 0.0001, respectively) as well as an increased inhomogeneity of the trabecular network (p < 0.0001 and p < 0.0001, respectively) were observed in OI-I and OI-III-IV in comparison to the control group. Similar results for trabecular parameters were found at the tibia. Microstructural parameters were worse in OI-III-IV than in OI-I. No significant differences were found in cortical thickness and cortical porosity between the three subgroups at the radius. The cortical thickness of the tibia was thinner in OI-I (p < 0.001), but not OI-III-IV, when compared to controls. CONCLUSIONS: Trabecular BMD and trabecular bone microstructure in particular are severely altered in patients with clinical OI-I and OI-III-IV. Low TBS and DXL and their significant associations to HR-pQCT parameters of trabecular bone support this conclusion.
Resumo:
Le nombre d'examens tomodensitométriques (Computed Tomography, CT) effectués chaque année étant en constante augmentation, différentes techniques d'optimisation, dont les algorithmes de reconstruction itérative permettant de réduire le bruit tout en maintenant la résolution spatiale, ont étés développées afin de réduire les doses délivrées. Le but de cette étude était d'évaluer l'impact des algorithmes de reconstruction itérative sur la qualité image à des doses effectives inférieures à 0.3 mSv, comparables à celle d'une radiographie thoracique. Vingt CT thoraciques effectués à cette dose effective ont été reconstruits en variant trois paramètres: l'algorithme de reconstruction, rétroprojection filtrée versus reconstruction itérative iDose4; la matrice, 5122 versus 7682; et le filtre de résolution en densité (mou) versus spatiale (dur). Ainsi, 8 séries ont été reconstruites pour chacun des 20 CT thoraciques. La qualité d'image de ces 8 séries a d'abord été évaluée qualitativement par deux radiologues expérimentés en aveugle en se basant sur la netteté des parois bronchiques et de l'interface entre le parenchyme pulmonaire et les vaisseaux, puis quantitativement en utilisant une formule de merit, fréquemment utilisée dans le développement de nouveaux algorithmes et filtres de reconstruction. La performance diagnostique de la meilleure série acquise à une dose effective inférieure à 0.3 mSv a été comparée à celle d'un CT de référence effectué à doses standards en relevant les anomalies du parenchyme pulmonaire. Les résultats montrent que la meilleure qualité d'image, tant qualitativement que quantitativement a été obtenue en utilisant iDose4, la matrice 5122 et le filtre mou, avec une concordance parfaite entre les classements quantitatif et qualitatif des 8 séries. D'autre part, la détection des nodules pulmonaires de plus de 4mm étaient similaire sur la meilleure série acquise à une dose effective inférieure à 0.3 mSv et le CT de référence. En conclusion, les CT thoraciques effectués à une dose effective inférieure à 0.3 mSv reconstruits avec iDose4, la matrice 5122 et le filtre mou peuvent être utilisés avec confiance pour diagnostiquer les nodules pulmonaires de plus de 4mm.
Resumo:
For decades, lung cancer has been the most common cancer in terms of both incidence and mortality. There has been very little improvement in the prognosis of lung cancer. Early treatment following early diagnosis is considered to have potential for development. The National Lung Screening Trial (NLST), a large, well-designed randomized controlled trial, evaluated low-dose computed tomography (LDCT) as a screening tool for lung cancer. Compared with chest X-ray, annual LDCT screening reduced death from lung cancer and overall mortality by 20 and 6.7 %, respectively, in high-risk people aged 55-74 years. Several smaller trials of LDCT screening are under way, but none are sufficiently powered to detect a 20 % reduction in lung cancer death. Thus, it is very unlikely that the NLST results will be replicated. In addition, the NLST raises several issues related to screening, such as the high false-positive rate, overdiagnosis and cost. Healthcare providers and systems are now left with the question of whether the available findings should be translated into practice. We present the main reasons for implementing lung cancer screening in high-risk adults and discuss the main issues related to lung cancer screening. We stress the importance of eligibility criteria, smoking cessation programs, primary care physicians, and informed-decision making should lung cancer screening be implemented. Seven years ago, we were waiting for the results of trials. Such evidence is now available. Similar to almost all other cancer screens, uncertainties exist and persist even after recent scientific efforts and data. We believe that by staying within the characteristics of the original trial and appropriately sharing the evidence as well as the uncertainties, it is reasonable to implement a LDCT lung cancer screening program for smokers and former smokers.
Resumo:
Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.
Resumo:
In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been used successfully in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits; to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
La diverticulite colique aiguë est une pathologie fréquente en particulier chez les personnes âgées et d'origine caucasienne. La prévalence est plus importante chez les sédentaires et les personnes ayant un régime comprenant peu de fibres. Son diagnostic se base principalement sur la tomodensitométrie (CT) qui permet d'orienter la prise en charge thérapeutique. Ces dernières années, le traitement de la diverticulite aiguë a passablement changé avec notamment une évolution vers une restriction des indications du traitement chirurgical électif ou en urgence et une désescalade thérapeutique, avec réduction de l'antibiothérapie et du nombre d'hospitalisations. Cet article passe en revue l'épidémiologie, les moyens diagnostiques et la prise en charge de cette pathologie digestive courante. Acute diverticulitis of the colon is a frequent pathology especially among elderly people and people of Caucasian origin. The prevalence is higher among sedentary people and in people with low-fiber diet. Its diagnosis is mainly based on computed tomography (CT) that allows guiding the therapeutic management. Over the last few years the treatment of acute diverticulitis has passably changed with in particular an evolution toward a restriction of the elective and emergency surgery indications and a reduction of the antiobiotherapy and hospitalization number. This article reviews the epidemiology, the diagnostic tools, and the management of this frequent digestive pathology.
Resumo:
BACKGROUND AND PURPOSE: For the STroke Imaging Research (STIR) and VISTA-Imaging Investigators The purpose of this study was to collect precise information on the typical imaging decisions given specific clinical acute stroke scenarios. Stroke centers worldwide were surveyed regarding typical imaging used to work up representative acute stroke patients, make treatment decisions, and willingness to enroll in clinical trials. METHODS: STroke Imaging Research and Virtual International Stroke Trials Archive-Imaging circulated an online survey of clinical case vignettes through its website, the websites of national professional societies from multiple countries as well as through email distribution lists from STroke Imaging Research and participating societies. Survey responders were asked to select the typical imaging work-up for each clinical vignette presented. Actual images were not presented to the survey responders. Instead, the survey then displayed several types of imaging findings offered by the imaging strategy, and the responders selected the appropriate therapy and whether to enroll into a clinical trial considering time from onset, clinical presentation, and imaging findings. A follow-up survey focusing on 6 h from onset was conducted after the release of the positive endovascular trials. RESULTS: We received 548 responses from 35 countries including 282 individual centers; 78% of the centers originating from Australia, Brazil, France, Germany, Spain, United Kingdom, and United States. The specific onset windows presented influenced the type of imaging work-up selected more than the clinical scenario. Magnetic Resonance Imaging usage (27-28%) was substantial, in particular for wake-up stroke. Following the release of the positive trials, selection of perfusion imaging significantly increased for imaging strategy. CONCLUSIONS: Usage of vascular or perfusion imaging by Computed Tomography or Magnetic Resonance Imaging beyond just parenchymal imaging was the primary work-up (62-87%) across all clinical vignettes and time windows. Perfusion imaging with Computed Tomography or Magnetic Resonance Imaging was associated with increased probability of enrollment into clinical trials for 0-3 h. Following the release of the positive endovascular trials, selection of endovascular only treatment for 6 h increased across all clinical vignettes.
Resumo:
Renal biopsy is being increasingly proposed as a diagnostic tool to characterize small renal masses (SRM). Indeed, the wide adoption of imaging in the diagnostic workup of many diseases had led to a substantial increased incidence of SRM (diameter ≤4 cm). While modern ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) techniques have high sensitivity for detecting SRM, none is able to accurately and reliably characterize them in terms of histological features. This is currently of key importance in guiding clinical decision-making in some situations, and in these cases renal biopsy should be considered. In this review, we aim to summarize the technique, diagnostic performance, and predicting factors of nondiagnostic biopsy, as well as the future perspectives.
Resumo:
BACKGROUND: Clinical guidelines are essential in implementing and maintaining nationwide stage-specific diagnostic and therapeutic standards. In 2011, the first German expert consensus guideline defined the evidence for diagnosis and treatment of early and locally advanced esophagogastric cancers. Here, we compare this guideline with other national guidelines as well as current literature. METHODS: The German S3-guideline used an approved development process with de novo literature research, international guideline adaptation, or good clinical practice. Other recent evidence-based national guidelines and current references were compared with German recommendations. RESULTS: In the German S3 and other Western guidelines, adenocarcinomas of the esophagogastric junction (AEG) are classified according to formerly defined AEG I-III subgroups due to the high surgical impact. To stage local disease, computed tomography of the chest and abdomen and endosonography are reinforced. In contrast, laparoscopy is optional for staging. Mucosal cancers (T1a) should be endoscopically resected "en-bloc" to allow complete histological evaluation of lateral and basal margins. For locally advanced cancers of the stomach or esophagogastric junction (≥T3N+), preferred treatment is preoperative and postoperative chemotherapy. Preoperative radiochemotherapy is an evidence-based alternative for large AEG type I-II tumors (≥T3N+). Additionally, some experts recommend treating T2 tumors with a similar approach, mainly because pretherapeutic staging is often considered to be unreliable. CONCLUSIONS: The German S3 guideline represents an up-to-date European position with regard to diagnosis, staging, and treatment recommendations for patients with locally advanced esophagogastric cancer. Effects of perioperative chemotherapy versus chemoradiotherapy are still to be investigated for adenocarcinoma of the cardia and the lower esophagus.
Resumo:
La tomodensitométrie (TDM) est une technique d'imagerie pour laquelle l'intérêt n'a cessé de croitre depuis son apparition au début des années 70. De nos jours, l'utilisation de cette technique est devenue incontournable, grâce entre autres à sa capacité à produire des images diagnostiques de haute qualité. Toutefois, et en dépit d'un bénéfice indiscutable sur la prise en charge des patients, l'augmentation importante du nombre d'examens TDM pratiqués soulève des questions sur l'effet potentiellement dangereux des rayonnements ionisants sur la population. Parmi ces effets néfastes, l'induction de cancers liés à l'exposition aux rayonnements ionisants reste l'un des risques majeurs. Afin que le rapport bénéfice-risques reste favorable au patient il est donc nécessaire de s'assurer que la dose délivrée permette de formuler le bon diagnostic tout en évitant d'avoir recours à des images dont la qualité est inutilement élevée. Ce processus d'optimisation, qui est une préoccupation importante pour les patients adultes, doit même devenir une priorité lorsque l'on examine des enfants ou des adolescents, en particulier lors d'études de suivi requérant plusieurs examens tout au long de leur vie. Enfants et jeunes adultes sont en effet beaucoup plus sensibles aux radiations du fait de leur métabolisme plus rapide que celui des adultes. De plus, les probabilités des évènements auxquels ils s'exposent sont également plus grandes du fait de leur plus longue espérance de vie. L'introduction des algorithmes de reconstruction itératifs, conçus pour réduire l'exposition des patients, est certainement l'une des plus grandes avancées en TDM, mais elle s'accompagne de certaines difficultés en ce qui concerne l'évaluation de la qualité des images produites. Le but de ce travail est de mettre en place une stratégie pour investiguer le potentiel des algorithmes itératifs vis-à-vis de la réduction de dose sans pour autant compromettre la qualité du diagnostic. La difficulté de cette tâche réside principalement dans le fait de disposer d'une méthode visant à évaluer la qualité d'image de façon pertinente d'un point de vue clinique. La première étape a consisté à caractériser la qualité d'image lors d'examen musculo-squelettique. Ce travail a été réalisé en étroite collaboration avec des radiologues pour s'assurer un choix pertinent de critères de qualité d'image. Une attention particulière a été portée au bruit et à la résolution des images reconstruites à l'aide d'algorithmes itératifs. L'analyse de ces paramètres a permis aux radiologues d'adapter leurs protocoles grâce à une possible estimation de la perte de qualité d'image liée à la réduction de dose. Notre travail nous a également permis d'investiguer la diminution de la détectabilité à bas contraste associée à une diminution de la dose ; difficulté majeure lorsque l'on pratique un examen dans la région abdominale. Sachant que des alternatives à la façon standard de caractériser la qualité d'image (métriques de l'espace Fourier) devaient être utilisées, nous nous sommes appuyés sur l'utilisation de modèles d'observateurs mathématiques. Nos paramètres expérimentaux ont ensuite permis de déterminer le type de modèle à utiliser. Les modèles idéaux ont été utilisés pour caractériser la qualité d'image lorsque des paramètres purement physiques concernant la détectabilité du signal devaient être estimés alors que les modèles anthropomorphes ont été utilisés dans des contextes cliniques où les résultats devaient être comparés à ceux d'observateurs humain, tirant profit des propriétés de ce type de modèles. Cette étude a confirmé que l'utilisation de modèles d'observateurs permettait d'évaluer la qualité d'image en utilisant une approche basée sur la tâche à effectuer, permettant ainsi d'établir un lien entre les physiciens médicaux et les radiologues. Nous avons également montré que les reconstructions itératives ont le potentiel de réduire la dose sans altérer la qualité du diagnostic. Parmi les différentes reconstructions itératives, celles de type « model-based » sont celles qui offrent le plus grand potentiel d'optimisation, puisque les images produites grâce à cette modalité conduisent à un diagnostic exact même lors d'acquisitions à très basse dose. Ce travail a également permis de clarifier le rôle du physicien médical en TDM: Les métriques standards restent utiles pour évaluer la conformité d'un appareil aux requis légaux, mais l'utilisation de modèles d'observateurs est inévitable pour optimiser les protocoles d'imagerie. -- Computed tomography (CT) is an imaging technique in which interest has been quickly growing since it began to be used in the 1970s. Today, it has become an extensively used modality because of its ability to produce accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase in the number of CT examinations performed has raised concerns about the potential negative effects of ionising radiation on the population. Among those negative effects, one of the major risks remaining is the development of cancers associated with exposure to diagnostic X-ray procedures. In order to ensure that the benefits-risk ratio still remains in favour of the patient, it is necessary to make sure that the delivered dose leads to the proper diagnosis without producing unnecessarily high-quality images. This optimisation scheme is already an important concern for adult patients, but it must become an even greater priority when examinations are performed on children or young adults, in particular with follow-up studies which require several CT procedures over the patient's life. Indeed, children and young adults are more sensitive to radiation due to their faster metabolism. In addition, harmful consequences have a higher probability to occur because of a younger patient's longer life expectancy. The recent introduction of iterative reconstruction algorithms, which were designed to substantially reduce dose, is certainly a major achievement in CT evolution, but it has also created difficulties in the quality assessment of the images produced using those algorithms. The goal of the present work was to propose a strategy to investigate the potential of iterative reconstructions to reduce dose without compromising the ability to answer the diagnostic questions. The major difficulty entails disposing a clinically relevant way to estimate image quality. To ensure the choice of pertinent image quality criteria this work was continuously performed in close collaboration with radiologists. The work began by tackling the way to characterise image quality when dealing with musculo-skeletal examinations. We focused, in particular, on image noise and spatial resolution behaviours when iterative image reconstruction was used. The analyses of the physical parameters allowed radiologists to adapt their image acquisition and reconstruction protocols while knowing what loss of image quality to expect. This work also dealt with the loss of low-contrast detectability associated with dose reduction, something which is a major concern when dealing with patient dose reduction in abdominal investigations. Knowing that alternative ways had to be used to assess image quality rather than classical Fourier-space metrics, we focused on the use of mathematical model observers. Our experimental parameters determined the type of model to use. Ideal model observers were applied to characterise image quality when purely objective results about the signal detectability were researched, whereas anthropomorphic model observers were used in a more clinical context, when the results had to be compared with the eye of a radiologist thus taking advantage of their incorporation of human visual system elements. This work confirmed that the use of model observers makes it possible to assess image quality using a task-based approach, which, in turn, establishes a bridge between medical physicists and radiologists. It also demonstrated that statistical iterative reconstructions have the potential to reduce the delivered dose without impairing the quality of the diagnosis. Among the different types of iterative reconstructions, model-based ones offer the greatest potential, since images produced using this modality can still lead to an accurate diagnosis even when acquired at very low dose. This work has clarified the role of medical physicists when dealing with CT imaging. The use of the standard metrics used in the field of CT imaging remains quite important when dealing with the assessment of unit compliance to legal requirements, but the use of a model observer is the way to go when dealing with the optimisation of the imaging protocols.
Resumo:
BACKGROUND: Most peripheral T-cell lymphoma (PTCL) patients have a poor outcome and the identification of prognostic factors at diagnosis is needed. PATIENTS AND METHODS: The prognostic impact of total metabolic tumor volume (TMTV0), measured on baseline [(18)F]2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography, was evaluated in a retrospective study including 108 PTCL patients (27 PTCL not otherwise specified, 43 angioimmunoblastic T-cell lymphomas and 38 anaplastic large-cell lymphomas). All received anthracycline-based chemotherapy. TMTV0 was computed with the 41% maximum standardized uptake value threshold method and an optimal cut-off point for binary outcomes was determined and compared with others prognostic factors. RESULTS: With a median follow-up of 23 months, 2-year progression-free survival (PFS) was 49% and 2-year overall survival (OS) was 67%. High TMTV0 was significantly associated with a worse prognosis. At 2 years, PFS was 26% in patients with a high TMTV0 (>230 cm(3), n = 53) versus 71% for those with a low TMTV0, [P < 0.0001, hazard ratio (HR) = 4], whereas OS was 50% versus 80%, respectively, (P = 0.0005, HR = 3.1). In multivariate analysis, TMTV0 was the only significant independent parameter for both PFS and OS. TMTV0, combined with PIT, discriminated even better than TMTV0 alone, patients with an adverse outcome (TMTV0 >230 cm(3) and PIT >1, n = 33,) from those with good prognosis (TMTV0 ≤230 cm(3) and PIT ≤1, n = 40): 19% versus 73% 2-year PFS (P < 0.0001) and 43% versus 81% 2-year OS, respectively (P = 0.0002). Thirty-one patients (other TMTV0-PIT combinations) had an intermediate outcome, 50% 2-year PFS and 68% 2-year OS. CONCLUSION: TMTV0 appears as an independent predictor of PTCL outcome. Combined with PIT, it could identify different risk categories at diagnosis and warrants further validation as a prognostic marker.
Resumo:
While the overall incidence of myocardial infarction (MI) has been decreasing since 2000 [1], there is an increasing number of younger patients presenting with MI [2]. Few studies have focused on MI in very young patients, aged 35 years or less, as they only account for a minority of all patients with myocardial infarction [3]. According to the age category, MI differs in presentation, treatment and outcome, as illustrated in table 1. Echocardiography is considered mandatory according to scientific guidelines in the management and diagnosis of MI [4,5,6]. However, new imaging techniques such as cardiac magnetic resonance (CMR) and computed tomography (CT) are increasingly performed and enable further refinement of the diagnosis of MI. These techniques allow, in particular, precise location and quantification of MI. In this case, MI was located to the septum, which is an unusual presentation of MI. The incidence of pulmonary embolism (PE) has also increased in young patients over the past years [7]. Since symptoms and signs of PE may be non-specific, establishing its diagnosis remains a challenge [8]. Therefore, PE is one of the most frequently missed diagnosis in clinical medicine. Because of the widespread use of CT and its improved visualization of pulmonary arteries, PE may be discovered incidentally [9]. In the absence of a congenital disorder, multiple and/or simultaneous disease presentation is uncommon in the young. We report the rare case of a 35 year old male with isolated septal MI and simultaneous PE. The diagnosis of this rare clinical entity was only possible by means of newer imaging techniques.