417 resultados para Rectangular Pressure Pulse
Resumo:
P>Aim: To determine the effects of imperfect adherence (i.e. occasionally missing prescribed doses), and the influence of rate of loss of antihypertensive effect during treatment interruption, on the predicted clinical effectiveness of antihypertensive drugs in reducing mean systolic blood pressure (SBP) and cardiovascular disease (CVD) risk.Method:The effects of imperfect adherence to antihypertensive treatment regimens were estimated using published patterns of missed doses, and taking into account the rate of loss of antihypertensive effect when doses are missed (loss of BP reduction in mmHg/day; the off-rate), which varies between drugs. Outcome measures were the predicted mean SBP reduction and CVD risk, determined from the Framingham Risk Equation for CVD.Results:In patients taking 75% of prescribed doses (typical of clinical practice), only long-acting drugs with an off-rate of similar to 1 mmHg/day were predicted to maintain almost the full mean SBP-lowering effect throughout the modelled period. In such patients, using shorter-acting drugs (e.g. an off-rate of similar to 5-6 mmHg/day) was predicted to lead to a clinically relevant loss of mean SBP reduction of > 2 mmHg. This change also influenced the predicted CVD risk reduction; in patients with a baseline 10-year CVD risk of 27.0% and who were taking 75% of prescribed doses, a difference in off-rate from 1 to 5 mmHg/day led to a predicted 0.5% absolute increase in 10-year CVD risk.Conclusions:In patients who occasionally miss doses of antihypertensives, modest differences in the rate of loss of antihypertensive effect following treatment interruption may have a clinically relevant impact on SBP reduction and CVD risk. While clinicians must make every effort to counsel and encourage each of their patients to adhere to their prescribed medication, it may also be prudent to prescribe drugs with a low off-rate to mitigate the potential consequences of missing doses.
Resumo:
Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are alpha-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom (R) TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom (R) DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 +/- 15% for plutonium and 73 +/- 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring Pu-239 in water samples at the mu Bq/l level, if ICP-SMS is used for the measurement.
Resumo:
Rapport de synthèseLe syndrome d'apnées obstructives du sommeil (SAOS) est une pathologie respiratoire fréquente. Sa prévalence est estimée entre 2 et 5% de la population adulte générale. Ses conséquences sont importantes. Notamment, une somnolence diurne, des troubles de la concentration, des troubles de la mémoire et une augmentation du risque d'accident de la route et du travail. Il représente également un facteur de risque cardiovasculaire indépendant.Ce syndrome est caractérisé par la survenue durant le sommeil d'obstructions répétées des voies aériennes supérieures. L'arrêt ou la diminution d'apport en oxygène vers les poumons entraîne des épisodes de diminution de la saturation en oxygène de l'hémoglobine. Les efforts ventilatoires visant à lever l'obstacle présent sur les voies aériennes causent de fréquents réveils à l'origine d'une fragmentation du sommeil.La polysomnographie (PSG) représente le moyen diagnostic de choix. Il consiste en l'enregistrement dans un laboratoire du sommeil et en présence d'un technicien diplômé, du tracé électroencéphalographique (EEG), de l'électrooculogramme (EOG), de l'électromyogramme mentonnier (EMG), du flux respiratoire nasal, de l'oxymétrie de pouls, de la fréquence cardiaque, de l'électrocardiogramme (ECG), des mouvements thoraciques et abdominaux, de la position du corps et des mouvements des jambes. L'examen est filmé par caméra infrarouge et les sons sont enregistrés.Cet examen permet entre autres mesures, de déterminer les événements respiratoires obstructifs nécessaires au diagnostic de syndrome d'apnée du sommeil. On définit une apnée lors d'arrêt complet du débit aérien durant au moins 10 secondes et une hypopnée en cas, soit de diminution franche de l'amplitude du flux respiratoire supérieure à 50% durant au moins 10 secondes, soit de diminution significative (20%) de l'amplitude du flux respiratoire pendant au minimum 10 secondes associée à un micro-éveil ou à une désaturation d'au moins 3% par rapport à la ligne de base. La détection des micro-éveils se fait en utilisant les dérivations électroencéphalographiques, électromyographiques et électrooculographiques. Il existe des critères visuels de reconnaissance de ces éveils transitoire: apparition de rythme alpha (8.1 à 12.0 Hz) ou beta (16 à 30 Hz) d'une durée supérieure à 3 secondes [20-21].Le diagnostic de S AOS est retenu si l'on retrouve plus de 5 événements respiratoires obstructifs par heure de sommeil associés soit à une somnolence diurne évaluée selon le score d'Epworth ou à au moins 2 symptômes parmi les suivants: sommeil non réparateur, étouffements nocturne, éveils multiples, fatigue, troubles de la concentration. Le S AOS est gradué en fonction du nombre d'événements obstructifs par heure de sommeil en léger (5 à 15), modéré (15 à 30) et sévère (>30).La polysomnographie (PSG) comporte plusieurs inconvénients pratiques. En effet, elle doit être réalisée dans un laboratoire du sommeil avec la présence permanente d'un technicien, limitant ainsi son accessibilité et entraînant des délais diagnostiques et thérapeutiques. Pour ces mêmes raisons, il s'agit d'un examen onéreux.La polygraphie respiratoire (PG) représente l'alternative diagnostique au gold standard qu'est l'examen polysomnographique. Cet examen consiste en l'enregistrement en ambulatoire, à savoir au domicile du patient, du flux nasalrespiratoire, de l'oxymétrie de pouls, de la fréquence cardiaque, de la position du corps et du ronflement (par mesure de pression).En raison de sa sensibilité et sa spécificité moindre, la PG reste recommandée uniquement en cas de forte probabilité de SAOS. Il existe deux raisons principales à l'origine de la moindre sensibilité de l'examen polygraphique. D'une part, du fait que l'état de veille ou de sommeil n'est pas déterminé avec précision, il y a dilution des événements respiratoires sur l'ensemble de l'enregistrement et non sur la période de sommeil uniquement. D'autre part, en l'absence de tracé EEG, la quantification des micro-éveils est impossible. Il n'est donc pas possible dans l'examen poly graphique, de reconnaître une hypopnée en cas de diminution de flux respiratoire de 20 à 50% non associée à un épisode de désaturation de l'hémoglobine de 3% au moins. Alors que dans l'examen polysomnographique, une telle diminution du flux respiratoire pourrait être associée à un micro-éveil et ainsi comptabilisée en tant qu'hypopnée.De ce constat est né la volonté de trouver un équivalent de micro-éveil en polygraphie, en utilisant les signaux à disposition, afin d'augmenter la sensibilité de l'examen polygraphique.Or plusieurs études ont démontrés que les micro-éveils sont associés à des réactions du système nerveux autonome. Lors des micro-éveils, on met en évidence la survenue d'une vasoconstriction périphérique. La variation du tonus sympathique associée aux micro-éveils peut être mesurée par différentes méthodes. Les variations de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie représentant un marqueur fiable de la vasoconstriction périphérique associée aux micro-réveils, il paraît donc opportun d'utiliser ce marqueur autonomique disponible sur le tracé des polygraphies ambulatoires afin de renforcer la sensibilité de cet examen.Le but de l'étude est d'évaluer la sensibilité des variations de l'amplitude de l'onde de pouls pour détecter des micro-réveils corticaux afin de trouver un moyen d'augmenter la sensibilité de l'examen polygraphique et de renforcer ainsi sont pouvoir diagnostic.L'objectif est de démontrer qu'une diminution significative de l'amplitude de l'onde pouls est concomitante à une activation corticale correspondant à un micro¬réveil. Cette constatation pourrait permettre de déterminer une hypopnée, en polygraphie, par une diminution de 20 à 50% du flux respiratoire sans désaturation de 3% mais associée à une baisse significative de l'amplitude de pouls en postulant que l'événement respiratoire a entraîné un micro-réveil. On retrouve par cette méthode les mêmes critères de scoring d'événements respiratoires en polygraphie et en polysomnographie, et l'on renforce la sensibilité de la polygraphie par rapport au gold standard polysomnographique.La méthode consiste à montrer en polysomnographie qu'une diminution significative de l'amplitude de l'onde de pouls mesurée par pulsoxymétrie est associée à une activation du signal électroencéphalographique, en réalisant une analyse spectrale du tracé EEG lors des baisses d'amplitude du signal d'onde de pouls.Pour ce faire nous avons réalisé une étude rétrospective sur plus de 1000 diminutions de l'amplitude de l'onde de pouls sur les tracés de 10 sujets choisis de manière aléatoire parmi les patients référés dans notre centre du sommeil (CIRS) pour suspicion de trouble respiratoire du sommeil avec somnolence ou symptomatologie diurne.Les enregistrements nocturnes ont été effectués de manière standard dans des chambres individuelles en utilisant le système d'acquisition Embla avec l'ensemble des capteurs habituels. Les données ont été par la suite visuellement analysées et mesurées en utilisant le software Somnologica version 5.1, qui fournit un signal de l'amplitude de l'onde de pouls (puise wave amplitude - PWA).Dans un premier temps, un technicien du sommeil a réalisé une analyse visuelle du tracé EEG, en l'absence des données du signal d'amplitude d'onde de pouls. Il a déterminé les phases d'éveil et de sommeil, les stades du sommeil et les micro¬éveils selon les critères standards. Les micro-éveils sont définis lors d'un changement abrupt dans la fréquence de l'EEG avec un pattern d'ondes thêta-alpha et/ou une fréquence supérieure à 16 Hz (en l'absence de fuseau) d'une durée d'au minimum trois secondes. Si cette durée excède quinze secondes, l'événement correspond à un réveil.Puis, deux investigateurs ont analysé le signal d'amplitude d'onde de pouls, en masquant les données du tracé EEG qui inclut les micro-éveils. L'amplitude d'onde de pouls est calculée comme la différence de valeur entre le zénith et le nadir de l'onde pour chaque cycle cardiaque. Pour chaque baisse de l'amplitude d'onde de pouls, la plus grande et la plus petite amplitude sont déterminées et le pourcentage de baisse est calculé comme le rapport entre ces deux amplitudes. On retient de manière arbitraire une baisse d'au moins 20% comme étant significative. Cette limite a été choisie pour des raisons pratiques et cliniques, dès lors qu'elle représentait, à notre sens, la baisse minimale identifiable à l'inspection visuelle. Chaque baisse de PWA retenue est divisée en 5 périodes contiguës de cinq secondes chacune. Deux avant, une pendant et deux après la baisse de PWA.Pour chaque période de cinq secondes, on a pratiqué une analyse spectrale du tracé EEG correspondant. Le canal EEG C4-A1 est analysé en utilisant la transformée rapide de Fourier (FFT) pour chaque baisse de PWA et pour chaque période de cinq secondes avec une résolution de 0.2 Hz. La distribution spectrale est catégorisée dans chaque bande de fréquence: delta (0.5 à 4.0 Hz); thêta (4.1 à 8.0Hz); alpha (8.1 à 12.0 Hz); sigma (12.1 à 16 Hz) et beta (16.1 à 30.0 Hz). La densité de puissance (power density, en μΥ2 ) pour chaque bande de fréquence a été calculée et normalisée en tant que pourcentage de la puissance totale. On a déterminé, ensuite, la différence de densité de puissance entre les 5 périodes par ANOVA on the rank. Un test post hoc Tukey est été utilisé pour déterminer si les différences de densité de puissance étaient significatives. Les calculs ont été effectués à l'aide du software Sigmastat version 3.0 (Systat Software San Jose, California, USA).Le principal résultat obtenu dans cette étude est d'avoir montré une augmentation significative de la densité de puissance de l'EEG pour toutes les bandes de fréquence durant la baisse de l'amplitude de l'onde de pouls par rapport à la période avant et après la baisse. Cette augmentation est par ailleurs retrouvée dans la plupart des bande de fréquence en l'absence de micro-réveil visuellement identifié.Ce résultat témoigné donc d'une activation corticale significative associée à la diminution de l'onde de pouls. Ce résulat pourrait permettre d'utiliser les variations de l'onde de pouls dans les tracés de polygraphie comme marqueur d'une activation corticale. Cependant on peut dire que ce marqueur est plus sensible que l'analyse visuelle du tracé EEG par un technicien puisque qu'on notait une augmentation de lactivité corticale y compris en l'absence de micro-réveil visuellement identifié. L'application pratique de ces résultats nécessite donc une étude prospective complémentaire.
Resumo:
BACKGROUND: Compromised growth after operation remains a significant problem in the cardiovascular field. Some benefit of absorbable suture materials has been demonstrated for arterial anastomoses. However, for the low-pressure zone, few data are available. METHODS: To assess growth in high- versus low-pressure zones we transected the abdominal aorta (high-pressure zone) as well as the inferior vena cava (low-pressure zone) in 10 young mongrel dogs using for reanastomosis 7-0 nonabsorbable versus absorbable running sutures in random order. RESULTS: All animals survived and were evaluated over 12 months including body weight (gain, 212% +/- 45% for nonabsorbable versus 218% +/- 8% for absorbable; not significant), angiography, and, after elective sacrifice, detailed studies of aorta and vena cava. Systematic complication of angiographic data at 12 months showed at the suture level an area of 13.8 mm2 for nonabsorbable versus 24.3 +/- 14.4 mm2 for absorbable sutures in the high-pressure zone as compared with 12.9 +/- 4.9 mm2 for nonabsorbable versus 25.3 +/- 15.4 mm2 for absorbable sutures in the low-pressure zone. Residual lumen, calculated as a function of the area above and below the suture, accounted for 35% +/- 10% for nonabsorbable versus 92% +/- 12% for absorbable sutures (p < 0.001) in the high-pressure zone as compared with 37% +/- 13% for nonabsorbable versus 75% +/- 15% for absorbable sutures (p < 0.003) in the low-pressure zone (high versus low, not significant). Poststenotic dilatation accounted for 199% +/- 22% for nonabsorbable versus 126% +/- 43% for absorbable sutures (p < 0.01) in the high-pressure zone. In the low-pressure zone, poststenotic dilatation remained below the inflow area, and the residual poststenotic lumen accounted for 52% +/- 14% for nonabsorbable versus 77% +/- 16% for absorbable sutures (p < 0.004). Macroscopic, light, and scanning electron microscopic studies confirmed different growth patterns in high- versus low-pressure zones. CONCLUSIONS: Aortic narrowing resulted in poststenotic dilatation and unrestricted outflow path (hourglass-type stenosis). Caval narrowing was followed by restriction of poststenotic outflow path (funnel-type stenosis). Absorbable suture material allows for superior growth in both high- and low-pressure zones.
Resumo:
Background: Numerous studies have shown a negative association between birth weight (BW) and blood pressure (BP) later in life. To estimate the direct effect of BW on BP, it is conventional to condition on current weight (CW). However, such conditioning can induce collider stratification bias in the estimate of the direct effect. Objective: To bound the potential bias due to U, an unmeasured common cause of CW and BP, on the estimate of the (controlled) direct effect of BW on BP. Methods: Data from a school based study in Switzerland were used (N = 4,005; 2,010 B/1,995 G; mean age: 12.3 yr [range: 10.1-14.9]). Measured common causes of BW-BP (SES, smoking, body weight, and hypertension status of the mother) and CW-BP (breastfeeding and child's physical activity and diet) were identified with DAGs. Linear regression models were fitted to estimate the association between BW and BP. Sensitivity analyses were conducted to assess the potential effect of U on the association between BW and BP. U was assumed 1) to be a binary variable that affected BP by the same magnitude in low BWand in normal BW children and 2) to have a different prevalence in low BW children and in normal BW children for a given CW. Results: A small negative association was observed between BW and BP [beta: -0.3 mmHg/kg (95% CI: -0.9 to 0.3)]. The association was strengthened upon conditioning for CW [beta: -1.5 mmHg/kg (95% CI: -2.1 to -0.9)]. Upon further conditioning on common causes of BW-BP and CW-BP, the association did not change substantially [beta: -1.4 mmHg/kg (95% CI: -2.0 to -0.8)]. The negative association could be explained by U only if U was strongly associated with BP and if there was a large difference in the prevalence of U between low BWand normal BW children. Conclusion: The observed negative association between BW and BP upon adjustment for CW was not easily explained by an unmeasured common cause of CWand BP.
Resumo:
BACKGROUND: The effect of the increasing prevalence of obesity on blood pressure (BP) secular trends is unclear. We analyzed BP and body mass index secular trends between 1998 and 2006 in children and adolescents of the Seychelles, a rapidly developing island state in the African region. METHODS AND RESULTS: School-based surveys were conducted annually between 1998 and 2006 among all students in 4 school grades (kindergarten and 4th, 7th, and 10th years of compulsory school). We used the Centers for Disease Control and Prevention criteria to define obesity and elevated BP. The same methods and instruments were used in all surveys. Some 25 586 children and adolescents 4 to 18 years of age contributed 43 867 observations. Although the prevalence of obesity in boys and girls increased from 5.1% and 6.0%, respectively, in 1998 to 2000 to 8.0% and 8.7% in 2004 to 2006, the prevalence of elevated BP decreased from 8.4% and 9.8% to 6.9% and 7.8%. During the interval, mean age-adjusted body mass index increased by 0.57 kg/m(2) in boys and 0.58 kg/m(2) in girls. Mean age- and height-adjusted systolic BP decreased by -3.0 mm Hg in boys and -2.8 mm Hg in girls, whereas mean diastolic BP did not change substantially in boys (-0.2 mm Hg) and increased slightly in girls (0.4 mm Hg). CONCLUSIONS: At a population level, the marked increase in the prevalence of obesity in children and adolescents in the Seychelles was not associated with a commensurate secular rise in mean BP.
Resumo:
Self-measurement of blood pressure (SMBP) is increasingly used to assess blood pressure outside the medical setting. A prerequisite for the wide use of SMBP is the availability of validated devices providing reliable readings when they are handled by patients. This is the case today with a number of fully automated oscillometric apparatuses. A major advantage of SMBP is the great number of readings, which is linked with high reproducibility. Given these advantages, one of the major indications for SMBP is the need for evaluation of antihypertensive treatment, either for individual patients in everyday practice or in clinical trials intended to characterize the effects of blood-pressure-lowering medications. In fact, SMBP is particularly helpful for evaluating resistant hypertension and detecting white-coat effect in patients exhibiting high office blood pressure under antihypertensive therapy. SMBP might also motivate the patient and improve his or her adherence to long-term treatment. Moreover, SMBP can be used as a sensitive technique for evaluating the effect of antihypertensive drugs in clinical trials; it increases the power of comparative trials, allowing one to study fewer patients or to detect smaller differences in blood pressure than would be possible with the office measurement. Therefore, SMBP can be regarded as a valuable technique for the follow-up of treated patients as well as for the assessment of antihypertensive drugs in clinical trials.
Resumo:
Elevated blood pressure is a common, heritable cause of cardiovascular disease worldwide. To date, identification of common genetic variants influencing blood pressure has proven challenging. We tested 2.5 million genotyped and imputed SNPs for association with systolic and diastolic blood pressure in 34,433 subjects of European ancestry from the Global BPgen consortium and followed up findings with direct genotyping (N ≤ 71,225 European ancestry, N ≤ 12,889 Indian Asian ancestry) and in silico comparison (CHARGE consortium, N = 29,136). We identified association between systolic or diastolic blood pressure and common variants in eight regions near the CYP17A1 (P = 7 × 10(-24)), CYP1A2 (P = 1 × 10(-23)), FGF5 (P = 1 × 10(-21)), SH2B3 (P = 3 × 10(-18)), MTHFR (P = 2 × 10(-13)), c10orf107 (P = 1 × 10(-9)), ZNF652 (P = 5 × 10(-9)) and PLCD3 (P = 1 × 10(-8)) genes. All variants associated with continuous blood pressure were associated with dichotomous hypertension. These associations between common variants and blood pressure and hypertension offer mechanistic insights into the regulation of blood pressure and may point to novel targets for interventions to prevent cardiovascular disease.
Resumo:
Non-invasive ambulatory blood pressure monitoring has proved to be very useful in evaluating hypertensive patients. However, most previous studies were performed in specialised centres. Here the results of two trials are presented in which private physicians used ambulatory BP monitoring to assess the efficacy of antihypertensive drugs. The results were very similar to those observed previously in specialised clinics. In the individual patient, the level of ambulatory recorded pressure could not be predicted based on BP readings taken at the doctor's office. Also, the BP response to antihypertensive therapy was more reproducible when evaluated by ambulatory BP monitoring than by the doctor. Thus, the use of noninvasive ambulatory BP monitoring is also very appropriate in everyday practice for the management of hypertensive patients.
Resumo:
The purpose of this study was to evaluate the contribution of renal sodium handling by the proximal tubule as an independent determinant of blood pressure responsiveness to salt in hypertension. We measured blood pressure (BP), renal hemodynamics, and segmental renal sodium handling (with lithium used as a marker of proximal sodium reabsorption) in 38 hypertensive patients and 27 normotensive subjects (15 young and 12 age-matched) on a high and low sodium diet. In control subjects, changing the diet from a low to a high sodium content resulted in no change in BP and increases in glomerular filtration rate (P<0.05), renal plasma flow (P<0.05), and fractional excretion of lithium (FE(Li), P<0.01). In hypertensive patients, comparable variations of sodium intake induced an increase in BP with no change in renal hemodynamics and proximal sodium reabsorption. When analyzed by tertiles of their BP response to salt, salt-insensitive hypertensive patients of the first tertile disclosed a pattern of adaptation of proximal sodium reabsorption comparable to that of control subjects, whereas the most salt-sensitive patients of the third tertile had an inverse pattern with a high FE(Li) on low salt and a lower FE(Li) on high salt, suggesting an inappropriate modulation of proximal sodium reabsorption. The BP response to salt correlated positively with age (r=0.34, P=0.036) and negatively with the changes in FE(Li) (r=-0.37, P=0.029). In a multivariate analysis, the changes in FE(Li) were significantly and independently associated with the salt-induced changes in BP. These results suggest that proximal sodium reabsorption is an independent determinant of the BP response to salt in hypertension.
Resumo:
The northeastern portion of the Mont Blanc massif in western Switzerland is predominantly comprised of the granitic rocks of the Mont Blanc intrusive suit, and the Mont Blanc basement gneisses. Within these metamorphic rocks are a variety of sub-economic Fe skarns. The mineral assemblages and fluid inclusions from these rocks have been used to derive age, pressure, temperature and fluid composition constraints for two Variscan events. Metamorphic hornblendes within the assemblages from the basement amphibolites and iron sk:lms have been dated using Ar-40/Ar-39, and indicate that these metamorphic events have a minimum age of approximately 334 Ma. Garnet-hornblende-plagioclase thermobarometry and stable isotope data obtained from the basement amphibolites are consistent with metamorphic temperatures in the range 515 to 580 degrees C, and pressures ranging from 5 to 8 kbar. Garnet-hornblende-magnetite thermobarometry and fluid inclusion studies indicate that the iron skarns formed at slightly lower temperatures, ranging from 400 to 500 degrees C in the presence of saline fluids at formational pressures similar to those experienced by the basement amphibolites. Late Paleozoic minimum uplift rates and geothermal gradients calculated using these data and the presence of Ladinien ichnofossils are on the order of 0.32 mm/year and 20 degrees C/km respectively. These uplift rates and geothermal gradients differ from those obtained from the neighbouring Aiguilles Rouges massif and indicate that these two massifs experienced different metamorphic conditions during the Carboniferous and Permian periods. During the early to late Carboniferous period the relative depths of the two massifs were reversed with the Aiguilles Rouges being initially unroofed at a much greater rate than the Mont Blanc, but experiencing relatively slower uplift rates near the termination of the Variscan orogeny.
Resumo:
The purpose of this study was to assess whether the administration of a calcium entry blocker can prevent the acute blood pressure rise induced by cigarette smoking. Seven male habitual smokers were included. After 45 min of equilibration, they took in randomized single-blind fashion at a 1 week interval either a placebo or nifedipine, 10 mg p.o. Thirty minutes thereafter, the subjects smoked within 10 min two cigarettes containing 1.4 mg of nicotine each. In addition to heart rate and skin blood flow (laser Doppler method), blood pressure of the median left finger was monitored continuously for 100 min using a noninvasive device (Finapres). Nifedipine induced an increase in skin blood flow that was not influenced by smoking. This skin blood flow response was observed although nifedipine had by itself no effect on systemic blood pressure. The calcium antagonist markedly attenuated the blood pressure rise induced by cigarette smoking. However, it tended to accentuate the heart rate acceleration resulting from inhalation of nicotine-containing smoke.