533 resultados para Radionuclide Angiography
Resumo:
BACKGROUND: Indocyanine green video-angiography (ICG) is a recent examination technique, its possibilities and limitations as far as intraocular tumours are concerned, haven't been fully explored yet. MATERIAL AND METHODS: We have studied 50 cases of non-pigmented choroidal tumours, including 14 cases of choroidal hemangioma's, 11 cases of posterior uveal metastases and 25 cases of non-pigmented melanoma's. RESULTS: Characteristic images were obtained when examining choroidal hemangioma's and, until a certain point, posterior choroidal metastases. Non pigmented melanoma's on the contrary, presented a great variety of different indocyanine green angiographic pictures. CONCLUSION: Indocyanine green video-angiography (ICG) has a definite value in the differential diagnosis of non-pigmented posterior choroidal tumours.
Resumo:
BACKGROUND: The SYNTAX score (SXscore), an angiographic score reflecting coronary lesion complexity, predicts clinical outcomes in patients with left main or multivessel disease, and in patients with ST-segment elevation myocardial infarction undergoing primary PCI. The clinical SXscore (CSS) integrates the SXscore and clinical variables (age, ejection fraction, serum creatinine) into a single score. We analyzed these scores in elderly patients with acute coronary syndrome (ACS) undergoing primary PCI. The purpose of this analysis was not to decide which patients should undergo PCI, but to predict clinical outcomes in this population. METHODS: The SXscore was determined in a consecutive series of 114 elderly patients (mean age, 79.6 ± 4.1 years) undergoing primary PCI for ACS. Outcomes were stratified according to SXscore tertiles: SXLOW ≤15 (n = 39), 15< SXMID <23 (n = 40), and SXHIGH ≥23 (n = 35). The primary endpoint was all-cause mortality at 30 days. Secondary endpoints were nonfatal major adverse cardiac and cerebrovascular events (MACCE) at 30 days, and 1-year outcomes in patients discharged alive. RESULTS: Mortality at 30 days was higher in the SXHIGH group compared with the aggregate SXLOW+MID group (37.1% vs 5.1%; P<.0001), and in the CSSHIGH group compared with the aggregate CSSLOW+MID group (25.5% vs 1.4%; P=.0001). MACCE rates at 30 days were similar among SXscore tertiles. The CSS predicted 1-year MACCE rates (12.1% for CSSHIGH vs 3.1% for CSSLOW+MID; P=.03). CONCLUSIONS: The SXscore predicts 30-day mortality in elderly patients with ACS undergoing primary PCI. In patients discharged alive, the CSS predicts risk of MACCE at 1 year.
Resumo:
OBJECTIVE: Ultrasounds are a useful tool when looking for indirect evidence in favor of pulmonary embolism. The aim of this study was to determine the incidence of acute cor pulmonale and deep venous thrombosis revealed by ultrasonographic techniques in a population of patients presenting with pulmonary embolism. METHODS: 96 consecutive patients with a mean (+/- SD) age of 65 +/- 15 years, admitted to our hospital for pulmonary embolism were included in this study. The diagnosis of pulmonary embolism was made either by spiral computed tomography or selective pulmonary angiography. Each patient subsequently underwent both trans-thoracic echocardiography and venous ultrasonography. The diagnostic criterion used for defining acute cor pulmonale by echocardiography was the right to left ventricular end-diastolic area ratio over (or equal to) 0.6. Diagnosis of deep venous thrombosis was supported by the visualization of thrombi or vein incompressibility and/or the absence of venous flow or loss of flow variability by venous ultrasonography. RESULTS: Using ultrasounds, an acute cor pulmonale was found in 63% of our patients while 79% were found to have deep venous thrombosis and 92% of the patients had either acute cor pulmonale or deep venous thrombosis or both. All of the patients with proximal pulmonary embolism had acute cor pulmonale and/or deep venous thrombosis. The presence of acute cor pulmonale on echocardiography was significantly higher in patients with proximal pulmonary embolism (p < 0.0001). CONCLUSION: This study emphasizes the potential value of ultrasonographic techniques in the diagnosis of acute pulmonary embolism.
Resumo:
Perfusion lung scan, whether associated with a ventilation lung scan or not, is frequently used in the diagnosis of pulmonary emboli. The characteristics of perfusion lung scan are reviewed. The added diagnostic value of standard chest X-ray and of ventilation scan is discussed, as well as its use in the intensive care unit.
Resumo:
F(ab')2-fragments of the anti-melanoma monoclonal antibody MeI-14 were labelled with 123I for external scanning and with 125I for tissue measurement of radioactivity and injected intravenously into patients scheduled for surgical resection of a glioma. The paired-label study was performed by injecting simultaneously 131I-labelled control (F(ab')2-fragments. The patients were scanned by computerised tomoscintigraphy. After surgery, the activities of 125I and 131I were counted in tumour and normal tissues. The results indicate that there was a low but definite uptake of the antibody in the tumour due to its specificity. The external detection was difficult because of accumulation of antibody fragments in the skull.
Resumo:
Parallel tracks for clinical scientists, basic scientists, and pediatric imagers was the novel approach taken for the highly successful 8th Annual Scientific Sessions of the Society for Cardiovascular Magnetic Resonance, held in San Francisco, California, January 21 to 23, 2005. Attendees were immersed in information on the latest scientific advances in cardiovascular magnetic resonance (CMR) from mice to man and technological advances from systems with field strengths from 0.5 T to 11.7 T. State-of-the-art applications were reviewed, spanning a wide range from molecular imaging to predicting outcome with CMR in large patient populations.
Resumo:
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Resumo:
PURPOSE: In the radiopharmaceutical therapy approach to the fight against cancer, in particular when it comes to translating laboratory results to the clinical setting, modeling has served as an invaluable tool for guidance and for understanding the processes operating at the cellular level and how these relate to macroscopic observables. Tumor control probability (TCP) is the dosimetric end point quantity of choice which relates to experimental and clinical data: it requires knowledge of individual cellular absorbed doses since it depends on the assessment of the treatment's ability to kill each and every cell. Macroscopic tumors, seen in both clinical and experimental studies, contain too many cells to be modeled individually in Monte Carlo simulation; yet, in particular for low ratios of decays to cells, a cell-based model that does not smooth away statistical considerations associated with low activity is a necessity. The authors present here an adaptation of the simple sphere-based model from which cellular level dosimetry for macroscopic tumors and their end point quantities, such as TCP, may be extrapolated more reliably. METHODS: Ten homogenous spheres representing tumors of different sizes were constructed in GEANT4. The radionuclide 131I was randomly allowed to decay for each model size and for seven different ratios of number of decays to number of cells, N(r): 1000, 500, 200, 100, 50, 20, and 10 decays per cell. The deposited energy was collected in radial bins and divided by the bin mass to obtain the average bin absorbed dose. To simulate a cellular model, the number of cells present in each bin was calculated and an absorbed dose attributed to each cell equal to the bin average absorbed dose with a randomly determined adjustment based on a Gaussian probability distribution with a width equal to the statistical uncertainty consistent with the ratio of decays to cells, i.e., equal to Nr-1/2. From dose volume histograms the surviving fraction of cells, equivalent uniform dose (EUD), and TCP for the different scenarios were calculated. Comparably sized spherical models containing individual spherical cells (15 microm diameter) in hexagonal lattices were constructed, and Monte Carlo simulations were executed for all the same previous scenarios. The dosimetric quantities were calculated and compared to the adjusted simple sphere model results. The model was then applied to the Bortezomib-induced enzyme-targeted radiotherapy (BETR) strategy of targeting Epstein-Barr virus (EBV)-expressing cancers. RESULTS: The TCP values were comparable to within 2% between the adjusted simple sphere and full cellular models. Additionally, models were generated for a nonuniform distribution of activity, and results were compared between the adjusted spherical and cellular models with similar comparability. The TCP values from the experimental macroscopic tumor results were consistent with the experimental observations for BETR-treated 1 g EBV-expressing lymphoma tumors in mice. CONCLUSIONS: The adjusted spherical model presented here provides more accurate TCP values than simple spheres, on par with full cellular Monte Carlo simulations while maintaining the simplicity of the simple sphere model. This model provides a basis for complementing and understanding laboratory and clinical results pertaining to radiopharmaceutical therapy.
Resumo:
Postmortem imaging, including postmortem computed tomography angiography, has become an integral tool in forensic investigation in recent years. A relatively new technique, multiphase postmortem computed tomography angiography, allows detailed visualization of the vascular system and makes it possible to evaluate the dynamic perfusion of aortic branches, including the coronary arteries. Here, we report a case of aortic dissection involving the ascending aorta (type A) with coronary and carotid malperfusion. This case illustrates the complementary use of many of the diagnostic tools that are now available in forensic practice, from imaging to conventional autopsy to pathologic techniques such as immunohistochemistry.
Resumo:
Current nuclear medicine techniques for the localization of inflammatory processes are based on injection of 111In labelled autologous granulocytes which need to be isolated and radiolabelled in vitro before reinjection. A new technique is presented here that obviates the need for cell isolation by the direct intravenous injection of a granulocyte specific 123I labelled monoclonal antibody. In this publication the basic parameters of the antibody granulocyte interaction are described. Antibody binding does not inhibit vital functions of the granulocytes, such as chemotaxis and superoxide generation. Scatchard analysis of binding data reveals an apparent affinity of the antibody for granulocytes of 6.8 X 10(9) l/mol and approximately 7.1 X 10(4) binding sites per cell. Due to the high specificity of the antibody, the only expected interference is from CEA producing tumors.
Resumo:
In the assessment of medical malpractice imaging methods can be used for the documentation of crucial morphological findings which are indicative for or against an iatrogenically caused injury. The clarification of deaths in this context can be usefully supported by postmortem imaging (primarily native computed tomography, angiography, magnetic resonance imaging). Postmortem imaging offers significant additional information compared to an autopsy in the detection of iatrogenic air embolisms and documentation of misplaced medical aids before dissection with an inherent danger of relocation. Additional information is supplied by postmortem imaging in the search for sources of bleeding as well as the documentation of perfusion after cardiovascular surgery. Key criteria for the decision to perform postmortem imaging can be obtained from the necessary preliminary inspection of clinical documentation.
Resumo:
PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.