316 resultados para Congenital aortic valve stenosis
Resumo:
OBJECTIVES: The purpose of this study was to determine whether thoracic endovascular aortic repair (TEVAR) reduces death and morbidity compared with open surgical repair for descending thoracic aortic disease. BACKGROUND: The role of TEVAR versus open surgery remains unclear. Metaregression can be used to maximally inform adoption of new technologies by utilizing evidence from existing trials. METHODS: Data from comparative studies of TEVAR versus open repair of the descending aorta were combined through meta-analysis. Metaregression was performed to account for baseline risk factor imbalances, study design, and thoracic pathology. Due to significant heterogeneity, registry data were analyzed separately from comparative studies. RESULTS: Forty-two nonrandomized studies involving 5,888 patients were included (38 comparative studies, 4 registries). Patient characteristics were balanced except for age, as TEVAR patients were usually older than open surgery patients (p = 0.001). Registry data suggested overall perioperative complications were reduced. In comparative studies, all-cause mortality at 30 days (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.33 to 0.59) and paraplegia (OR: 0.42, 95% CI: 0.28 to 0.63) were reduced for TEVAR versus open surgery. In addition, cardiac complications, transfusions, reoperation for bleeding, renal dysfunction, pneumonia, and length of stay were reduced. There was no significant difference in stroke, myocardial infarction, aortic reintervention, and mortality beyond 1 year. Metaregression to adjust for age imbalance, study design, and pathology did not materially change the results. CONCLUSIONS: Current data from nonrandomized studies suggest that TEVAR may reduce early death, paraplegia, renal insufficiency, transfusions, reoperation for bleeding, cardiac complications, pneumonia, and length of stay compared with open surgery. Sustained benefits on survival have not been proven.
Resumo:
OBJECTIVES: To evaluate prenatal diagnosis of congenital heart diseases by ultrasound investigation in well-defined European populations. DESIGN: Data from 20 registries of congenital malformations in 12 European countries were included. The prenatal ultrasound screening programs in the countries ranged from no routine screening to three ultrasound investigations per patient routinely performed. RESULTS: There were 2454 cases with congenital heart disease with an overall prenatal detection rate of 25%. Termination of pregnancy was performed in 293 cases (12%). There was considerable variation in prenatal detection rate between regions, with the lowest detection rates being in countries without ultrasound screening (11%) and in Eastern European countries (Croatia, Lithuania and Ukraine; 8%). In Western European countries with ultrasound screening, detection rate ranged from 19-48%. There was a significant difference in prenatal detection rate and proportion of induced abortions between isolated congenital heart disease and congenital heart disease associated with chromosome anomalies, multiple malformations and syndromes (P < 0.0001). There were 1694 cases with isolated congenital heart disease of which 16% were diagnosed prenatally. Malformations affecting the size of the ventricles were detected prenatally in half of the cases. CONCLUSIONS: Prenatal detection rate of congenital heart disease varies significantly between countries even with the same screening recommendations. The presence of associated malformations significantly increases the prenatal detection rate.
Resumo:
Congenital stationary night blindness (CSNB) is a heterogeneous retinal disorder characterized by visual impairment under low light conditions. This disorder is due to a signal transmission defect from rod photoreceptors to adjacent bipolar cells in the retina. Two forms can be distinguished clinically, complete CSNB (cCSNB) or incomplete CSNB; the two forms are distinguished on the basis of the affected signaling pathway. Mutations in NYX, GRM6, and TRPM1, expressed in the outer plexiform layer (OPL) lead to disruption of the ON-bipolar cell response and have been seen in patients with cCSNB. Whole-exome sequencing in cCSNB patients lacking mutations in the known genes led to the identification of a homozygous missense mutation (c.1807C>T [p.His603Tyr]) in one consanguineous autosomal-recessive cCSNB family and a homozygous frameshift mutation in GPR179 (c.278delC [p.Pro93Glnfs(∗)57]) in a simplex male cCSNB patient. Additional screening with Sanger sequencing of 40 patients identified three other cCSNB patients harboring additional allelic mutations in GPR179. Although, immunhistological studies revealed Gpr179 in the OPL in wild-type mouse retina, Gpr179 did not colocalize with specific ON-bipolar markers. Interestingly, Gpr179 was highly concentrated in horizontal cells and Müller cell endfeet. The involvement of these cells in cCSNB and the specific function of GPR179 remain to be elucidated.
Resumo:
PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.
Resumo:
OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.
Resumo:
Purpose:We previously observed that anti- and pro-apoptotic genes of the Bcl-2 family were differentially expressed during the development of LCA in the Rpe65-/- mouse model (Cottet et al. 2006). Moreover, we reported that activation and translocation of pro-apoptotic Bax to the mitochondria was associated with apoptosis of rod photoreceptors as the disease progressed (Cottet et al. 2008). In this study we challenged whether disruption of the pro-apoptotic pro-apoptotic Bax protein is sufficient to protect photoreceptor cells against apoptosis. Methods:Apoptosis of photoreceptor cells was addressed by TUNEL assay on flatmounted retinas. Counting of the rod nuclei within the ONL was performed following hematoxylin/eosin histological staining of retina sections. Expression level and localization of photoreceptor gene markers were assessed by quantitative PCR and immunohistological analyses. Results:While expression of rod photoreceptor genes was decreased in Rpe65-deficient retina, expression level remained unchanged in Rpe65-/- / Bax-/- mice. Moreover, OS dysorganization and shortening as well as decrease in ONL thickness observed in diseased retina were prevented in mice lacking functional Bax protein. TUNEL assay confirmed that Bax-dependent rod photoreceptor apoptosis was abolished in Rpe65-/- / Bax-/- mice. However, early and fast degeneration of cone cells was not prevented in Rpe65-/- / Bax-/- mice, indicating that Bax-induced apoptotic pathway was not involved in the degenerating process of cones in Rpe65-deficient retina. Conclusions:Altogether, these data show for the first time that a single genetic mutation can trigger two independent apoptotic pathways in rod and cone photoreceptors in LCA disease. While pro-apoptotic Bax is essential to trigger rod photoreceptor apoptosis, early degeneration of cones is not dependent on Bax-mediated apoptotic pathway in Rpe65-deficientmice.
Resumo:
BACKGROUND: Genetic predisposition to life-threatening cardiac arrhythmias such as congenital long-QT syndrome (LQTS) and catecholaminergic polymorphic ventricular tachycardia (CPVT) represent treatable causes of sudden cardiac death in young adults and children. Recently, mutations in calmodulin (CALM1, CALM2) have been associated with severe forms of LQTS and CPVT, with life-threatening arrhythmias occurring very early in life. Additional mutation-positive cases are needed to discern genotype-phenotype correlations associated with calmodulin mutations. METHODS AND RESULTS: We used conventional and next-generation sequencing approaches, including exome analysis, in genotype-negative LQTS probands. We identified 5 novel de novo missense mutations in CALM2 in 3 subjects with LQTS (p.N98S, p.N98I, p.D134H) and 2 subjects with clinical features of both LQTS and CPVT (p.D132E, p.Q136P). Age of onset of major symptoms (syncope or cardiac arrest) ranged from 1 to 9 years. Three of 5 probands had cardiac arrest and 1 of these subjects did not survive. The clinical severity among subjects in this series was generally less than that originally reported for CALM1 and CALM2 associated with recurrent cardiac arrest during infancy. Four of 5 probands responded to β-blocker therapy, whereas 1 subject with mutation p.Q136P died suddenly during exertion despite this treatment. Mutations affect conserved residues located within Ca(2+)-binding loops III (p.N98S, p.N98I) or IV (p.D132E, p.D134H, p.Q136P) and caused reduced Ca(2+)-binding affinity. CONCLUSIONS: CALM2 mutations can be associated with LQTS and with overlapping features of LQTS and CPVT.
Resumo:
Introduction: Surgical decision making in lumbar spinal stenosis (LSS) takes into account primarily clinical symptoms as well as concordant radiological findings. We hypothesized that a wide variation of operative threshold would be found in particular as far as judgment of severity of radiological stenosis is concerned. Patients and methods: The number of surgeons who would proceed to decompression was studied relative to the perceived severity of radiological stenosis based either on measurements of dural sac cross sectional area (DSCA) or on the recently described morphological grading as seen on axial T2 MRI images. A link to an electronic survey page with a set of ten axial T2 MRI images taken from ten patients with either low back pain or LSS were sent to members of three national or international spine societies. Those 10 images were randomly presented initially and re-shuffled on a second page including this time DSCA measurements in mm2, ranging from 14 to 226 mm2, giving a total of 20 images to appraise. Morphological grades were ranging from grade A to D. Surgeons were asked if they would consider decompression given the radiological appearance of stenosis and that symptoms of neurological claudication were severe in patients who were otherwise fit for surgery. Fisher's exact test was performed following dichotomization of data when appropriate. Results: A total of 142 spine surgeons (113 orthopedic spine surgeons, 29 neurosurgeons) responded from 25 countries. A substantial agreement was observed in operating patients with severe (grade C) or extreme (grade D) stenosis as defined by the morphological grade compared to lesser stenosis (A&B) grades (p<0.0001). Decision to operate was not dependent on number of years in practice, medical density in practicing country or specialty although more neurosurgeons would operate on grade C stenosis (p<0.005). Disclosing the DSCA measurement did not alter the decision to operate. Although 20 surgeons only had prior knowledge of the description of the morphological grading, their responses showed no statistically significant difference with those of the remaining 122 physicians. Conclusions: This study showed that surgeons across borders are less influenced by DSCA in their decision making than by the morphological appearance of the dural sac. Classifying LSS according to morphology rather than surface measurements appears to be consistent with current clinical practice.
Resumo:
Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.
Resumo:
There is no doubt that the European Association for Cardio-Thoracic Surgery is a success story. In 2011, we celebrated the 25th anniversary of this professional organization. In 2012, we will celebrate the 25th anniversary of the European Journal of Cardio-Thoracic Surgery. In addition, two other journals have been initiated, Interactive CardioVascular and Thoracic Surgery and the Multimedia Manual of Cardio-Thoracic Surgery, and all of them can be accessed through CTSnet (www.ctsnet.org). The most recent development was the birth of EACTS House, and it was to celebrate the official opening of EACTS House on 10 February 2011, that we held the second Strategic meeting, 'EACTS in the Future'. On this occasion, the EACTS council and delegates of the EACTS Domains (Domain of Thoracic Disease, Domain of Vascular Disease, Domain of Congenital Cardiac Disease and Domain of Adult Cardiac Disease) came together with representative thoracic and cardio-vascular surgeons from North America, Asia and BRICS countries as well as senior managers from industry in order to decide where to go from there. As a basis for starting the discussions, a sector analysis of the activities of the Department of Cardio-Vascular Surgery at CHUV in Lausanne, Switzerland was performed in order to identify the trends in the activities of our group of surgeons by pulling the consolidated data for the period running from 1 January 1995 to 31 December 2010. Interestingly enough, the most frequent procedures like coronary artery bypass graft and valve repair/replacement did not increase despite a growing programme. In our setting, the compensation came mainly from vascular surgery and mechanical circulatory support. These data have to be put in perspective by the reports provided by the EACTS domain chairs in order to identify the challenges and opportunities for the future development of our specialties.
Resumo:
BACKGROUND: Maternal pregestational diabetes is a well-known risk factor for congenital anomalies. This study analyses the spectrum of congenital anomalies associated with maternal diabetes using data from a large European database for the population-based surveillance of congenital anomalies. METHODS: Data from 18 population-based EUROCAT registries of congenital anomalies in 1990-2005. All malformed cases occurring to mothers with pregestational diabetes (diabetes cases) were compared to all malformed cases in the same registry areas to mothers without diabetes (non-diabetes cases). RESULTS: There were 669 diabetes cases and 92,976 non diabetes cases. Odds ratios in diabetes pregnancies relative to non-diabetes pregnancies comparing each EUROCAT subgroup to all other non-chromosomal anomalies combined showed significantly increased odds ratios for neural tube defects (anencephaly and encephalocele, but not spina bifida) and several subgroups of congenital heart defects. Other subgroups with significantly increased odds ratios were anotia, omphalocele and bilateral renal agenesis. Frequency of hip dislocation was significantly lower among diabetes (odds ratio 0.15, 95% CI 0.05-0.39) than non-diabetes cases. Multiple congenital anomalies were present in 13.6 % of diabetes cases and 6.1 % of non-diabetes cases. The odds ratio for caudal regression sequence was very high (26.40,95% CI 8.98-77.64), but only 17% of all caudal regression cases resulted from a pregnancy with pregestational diabetes. CONCLUSIONS: The increased risk of congenital anomalies in pregnancies with pregestational diabetes is related to specific non-chromosomal congenital anomalies and multiple congenital anomalies and not a general increased risk.