342 resultados para CT scan


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To identify patients with spontaneous subarachnoid hemorrhage for whom CT angiography alone can exclude ruptured aneurysms. METHODS: An observational retrospective review was carried out of all consecutive patients with non-traumatic subarachnoid hemorrhage who underwent both CT angiography and catheter angiography to exclude an aneurysm. CT angiography negative cases (no aneurysm) were classified according to their CT hemorrhage pattern as "aneurismal", "perimesencephalic" or as "no-hemorrhage." RESULTS: Two hundred and forty-one patients were included. A CT angiography aneurysm detection sensitivity and specificity of 96.4% and 96.0% were observed. All 35 cases of perimesencephalic or no-hemorrhage out of 78 CT angiography negatives also had negative angiography findings. CONCLUSIONS: CT angiography is self-reliant to exclude ruptured aneurysms when either a perimesencephalic hemorrhage or no-hemorrhage pattern is identified on the CT within a week of symptom onset.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron emission computed tomography (PET) is a functional, noninvasive method for imaging regional metabolic processes that is nowadays most often combined to morphological imaging with computed tomography (CT). Its use is based on the well-founded assumption that metabolic changes occur earlier in tumors than morphologic changes, adding another dimension to imaging. This article will review the established and investigational indications and radiopharmaceuticals for PET/CT imaging for prostate cancer, bladder cancer and testicular cancer, before presenting upcoming applications in radiation therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: 1. To review Ct features suggestive of saprophytic aspergillosis (aspergilloma) and to correlate them with the final pathological results. 2. To illustrate the wide range of differential diagnosis. Methods and materials: The electronic database of our department from 1995 to 2007 revealed CT reports of 48 patients that had been considered very suggestive of aspergilloma. Two radiologists with 6 and 12 years experience in thoracic radiology jointly reviewed the corresponding CT features including ancillary findings and the underlying lung diseases and correlated them with the final pathological diagnosis. Results: Forty patients could be included in the study (12 women, mean age 52), while in 8 patients there was no adequate clinical follow-up. In 17 patients the diagnosis "mycetoma" due to aspergillus fumigatus infection was confirmed, either by surgery, biopsy or bronchoscopy. In 23 patients, differential diagnoses were found, such as cavitating bronchial carcinoma (n = 7), bacterial abscess (n = 3), typical (n = 2) and atypical (n = 2) tuberculosis, as well as inflammatory changes due to mucoviscidosis (n = 1), Wegener's disease (n = 1) or chronic obstructive pulmonary disease (n = 3). Fibromyxoide hamartoma, lung infarction and bronchomucocele were responsible for the typical CT feature in one patient each. Conclusion: 1. The typical CT feature suggesting mycetoma is softtissue proliferation within a pre-existing wall-thickened lung cavity, oten even considered "pathognomonic". However, this diagnosis was finally confirmed by surgery or laboratory findings in less than 50% of patients only. 2. Since differential diagnoses are very large, not only including cavitating lung cancer and tuberculosis, the individual underlying lung disease needs strongly being taken into account often giving the best clue for the correct diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Messages à retenir: Le scanner peut aider au diagnostic et la caractérisation des valvulopathies et des lésions associées (aorte, coronaires). Le scanner est un examen incontournable pour l'évaluation pré-thérapeutique des procédures TAVI (transfémorale ou transapicale). Le scanner peut être utile pour caractériser les insuffisances aortiques. Grâce aux développements récents dans les thérapies peu invasives et au progrès du CT, le rôle du radiologue est redevenu central dans la prise en charge de certaines valvulopathies aortiques. Résumé: Les valvulopathies aortiques sont des maladies fréquentes. Leur exploration repose largement sur l'échocardiographie et sur l'IRM. Les progrès technologiques en scanner cardiaque ont permis à ce dernier d'explorer la valve aortique et ses pathologies. Ce cours est principalement consacré aux méthodes d'acquisition et de traitement des images dédiées à l'exploration de la valve aortique (plan de coupes, planimétrie, scores...). Une attention particulière est réservée aux considérations anatomiques spécifiques à celle-ci (variantes anatomiques). Les indications du scanner cardiaque dans les valvulopathies seront résumées (sténoses, insuffisances, pathologie tumorale et pathologies inflammatoires). Dans la sténose de la valve, outre ses performances diagnostiques, le scanner plus ou moins couplé à l'exploration des vaisseaux périphériques, est devenu une méthode intournable dans le bilan pré-thérapeutique. La connaissance des paramètres à évaluer (taille de l'anneau, position des coronaires, orientation du plan de la valve...) et la standardisation des mesures sont un élément clé pour une prise en charge optimale. Dans les insuffisances aortiques, les méthodes de quantification (planimétrie) peuvent être utilisées pour les caractériser avec des performances comparables à celles obtenues par d'autres techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate helical CT angiography in the assessment of occlusive arterial disease of abdominal aorta and the lower extremities. Sixteen patients underwent both transcatheter angiography and helical CT. Helical CT was inconclusive in 6.2% of segments whereas angiography was inconclusive in 5%. The overall sensitivity of helical CT was 91% and specificity 93%. Segmental analysis found a sensitivity of 43% in infrapopliteal arteries, and a specificity of 86%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In oncology, positron emission computed tomography (PET/CT) has become an essential tool for initial staging, response evaluation and follow-up of cancer patients. Most of the frequent tumors (lung, breast, esophagus, and lymphomas) are highly avid for (18)F-fluorodeoxyglucose ((18)FDG), but prostate cancer has not demonstrated significant uptake of FDG. The development of new tracers labeled with (18)F such as choline analogs allowed already to obtain interesting results particularly in patients with biological relapse and inconclusive conventional imaging workup. The impact of (18)F-flurocholine PET/CT on patient management needs to be validated in large studies, but many centers use already this examination in order to guide further management, including radiotherapy planning. (C) 2011 Elsevier Masson SAS. All rights reserved.