315 resultados para Active reconstruction
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
This study presents an innovative methodology for forensic science image analysis for event reconstruction. The methodology is based on experiences from real cases. It provides real added value to technical guidelines such as standard operating procedures (SOPs) and enriches the community of practices at stake in this field. This bottom-up solution outlines the many facets of analysis and the complexity of the decision-making process. Additionally, the methodology provides a backbone for articulating more detailed and technical procedures and SOPs. It emerged from a grounded theory approach; data from individual and collective interviews with eight Swiss and nine European forensic image analysis experts were collected and interpreted in a continuous, circular and reflexive manner. Throughout the process of conducting interviews and panel discussions, similarities and discrepancies were discussed in detail to provide a comprehensive picture of practices and points of view and to ultimately formalise shared know-how. Our contribution sheds light on the complexity of the choices, actions and interactions along the path of data collection and analysis, enhancing both the researchers' and participants' reflexivity.
Resumo:
The design of therapeutic cancer vaccines is aimed at inducing high numbers and potent T cells that are able to target and eradicate malignant cells. This calls for close collaboration between cells of the innate immune system, in particular dendritic cells (DCs), and cells of the adaptive immune system, notably CD4+ helper T cells and CD8+ cytotoxic T cells. Therapeutic vaccines are aided by adjuvants, which can be, for example, Toll¬like Receptor agonists or agents promoting the cytosolic delivery of antigens, among others. Vaccination with long synthetic peptides (LSPs) is a promising strategy, as the requirement for their intracellular processing will mainly target LSPs to professional antigen presenting cells (APCs), hence avoiding the immune tolerance elicited by the presentation of antigens by non-professional APCs. The unique property of antigen cross-processing and cross-presentation activity by DCs plays an important role in eliciting antitumour immunity given that antigens from engulfed dead tumour cells require this distinct biological process to be processed and presented to CD8+T cells in the context of MHC class I molecules. DCs expressing the XCR1 chemokine receptor are characterised by their superior capability of antigen cross- presentation and priming of highly cytotoxic T lymphocyte (CTL) responses. Recently, XCR1 was found to be also expressed in tissue-residents DCs in humans, with a simitar transcriptional profile to that of cross- presenting murine DCs. This shed light into the value of harnessing this subtype of XCR1+ cross-presenting DCs for therapeutic vaccination of cancer. In this study, we explored ways of adjuvanting and optimising LSP therapeutic vaccinations by the use, in Part I, of the XCLl chemokine that selectively binds to the XCR1 receptor, as a mean to target antigen to the cross-presenting XCR1+ DCs; and in Part II, by the inclusion of Q.S21 in the LSP vaccine formulation, a saponin with adjuvant activity, as well as the ability to promote cytosolic delivery of LSP antigens due to its intrinsic cell membrane insertion activity. In Part I, we designed and produced XCLl-(OVA LSP)-Fc fusion proteins, and showed that their binding to XCR1+ DCs mediate their chemoattraction. In addition, therapeutic vaccinations adjuvanted with XCLl-(OVA LSP)-Fc fusion proteins significantly enhanced the OVA-specific CD8+ T cell response, and led to complete tumour regression in the EL4-OVA model, and significant control of tumour growth in the B16.0VA tumour model. With the aim to optimise the co-delivery of LSP antigen and XCLl to skin-draining lymph nodes we also tested immunisations using nanoparticle (NP)-conjugated OVA LSP in the presence or absence of XCLl chemokine. The NP-mediated delivery of LSP potentiated the CTL response seen in the blood of vaccinated mice, and NP-OVA LSP vaccine in the presence of XCLl led to higher blood frequencies of OVA-specific memory-precursor effector cells. Nevertheless, in these settings, the addition XCLl to NP-OVA LSP vaccine formulation did not increase its antitumour therapeutic effect. In the Part II, we assessed in HLA-A2/DR1 mice the immunogenicity of the Melan-AA27L LSP or the Melan-A26. 35 AA27l short synthetic peptide (SSP) used in conjunction with the saponin adjuvant QS21, aiming to identify a potent adjuvant formulation that elicits a quantitatively and qualitatively strong immune response to tumour antigens. We showed a high CTL immune response elicited by the use of Melan-A LSP or SSP with QS21, which both exerted similar killing capacity upon in vivo transfer of target cells expressing the Melan-A peptide in the context of HLA-A2 molecules. However, the response generated by the LSP immunisation comprised higher percentages of CD8+T cells of the central memory phenotype (CD44hl CD62L+ and CCR7+ CD62L+) than those of SSP immunisation, and most importantly, the strong LSP+QS21 response was strictly CD4+T cell-dependent, as shown upon CD4 T cell depletion. Altogether, these results suggest that both XCLl and QS21 may enhance the ability of LSP to prime CD8 specific T cell responses, and promote a long-term memory response. Therefore, these observations may have important implications for the design of protein or LSP-based cancer vaccines for specific immunotherapy of cancer -- Les vacans thérapeutiques contre le cancer visent à induire une forte et durable réponse immunitaire contre des cellules cancéreuses résiduelles. Cette réponse requiert la collaboration entre le système immunitaire inné, en particulier les cellules dendrites (DCs), et le système immunitaire adaptatif, en l'occurrence les lymphocytes TCD4 hdper et CD8 cytotoxiques. La mise au point d'adjuvants et de molécules mimant un agent pathogène tels les ligands TLRs ou d'autres agents facilitant l'internalisation d'antigènes, est essentielle pour casser la tolérance du système immunitaire contre les cellules cancéreuses afin de générer une réponse effectrice et mémoire contre la tumeur. L'utilisation de longs peptides synthétiques (LSPs) est une approche prometteuse du fait que leur présentation en tant qu'antigénes requiert leur internalisation et leur transformation par les cellules dendrites (DCs, qui sont les mieux à même d'éviter la tolérance immunitaire. Récemment une sous-population de DCs exprimant le récepteur XCR1 a été décrite comme ayant une capacité supérieure dans la cross-présentation d'antigènes, d'où un intérêt à développer des vaccins ciblant les DCs exprimant le XCR1. Durant ma thèse de doctorat, j'ai exploré différentes approches pour optimiser les vaccins avec LSPs. La première partie visait à cibler les XCR1-DCs à l'aide de la chemokine XCL1 spécifique du récepteur XCR1, soit sou s la forme de protéine de fusion XCL1-OVA LSP-Fc, soit associée à des nanoparticules. La deuxième partie a consisté à tester l'association des LSPs avec I adjuvant QS21 dérivant d'une saponine dans le but d'optimiser l'internalisation cytosolique des longs peptides. Les protéines de fusion XCLl-OVA-Fc développées dans la première partie de mon travail, ont démontré leur capacité de liaison spécifique sur les XCRl-DCs associée à leur capacité de chemo-attractio. Lorsque inclues dans une mmunisation de souris porteuse de tumeurs établies, ces protéines de fusion XCL1-0VA LSP-Fc et XCLl-Fc plus OVA LSP ont induites une forte réponse CDS OVA spécifique permettant la complète régression des tumeurs de modèle EL4- 0VA et un retard de croissance significatif de tumeurs de type B16-0VA. Dans le but d'optimiser le drainage des LSPs vers es noyaux lymphatiques, nous avons également testé les LSPs fixés de manière covalente à des nanoparticules co- injectees ou non avec la chemokine XCL1. Cette formulation a également permis une forte réponse CD8 accompagnée d'un effet thérapeutique significatif, mais l'addition de la chemokine XCL1 n'a pas ajouté d'effet anti-tumeur supplémentaire. Dans la deuxième partie de ma thèse, j'ai comparé l'immunogénicité de l'antigène humain Melan A soit sous la forme d un LSP incluant un épitope CD4 et CD8 ou sous la forme d'un peptide ne contenant que l'épitope CD8 (SSP) Les peptides ont été formulés avec l'adjuvant QS21 et testés dans un modèle de souris transgéniques pour les MHC let II humains, respectivement le HLA-A2 et DR1. Les deux peptides LSP et SSP ont généré une forte réponse CD8 similaire assoc.ee a une capacité cytotoxique équivalente lors du transfert in vivo de cellules cibles présentant le peptide SSP' Cependant les souris immunisées avec le Melan A LSP présentaient un pourcentage plus élevé de CD8 ayant un Phénotype «centra, memory» (CD44h' CD62L+ and CCR7+ CD62L+) que les souris immunisées avec le SSP, même dix mois après I'immunisation. Par ailleurs, la réponse CD8 au Melan A LSP était strictement dépendante des lymphocytes CD4, contrairement à l'immunisation par le Melan A SSP qui n'était pas affectée. Dans l'ensemble ces résultats suggèrent que la chemokine XCL1 et l'adjuvant QS21 améliorent la réponse CD8 à un long peptide synthétique, favorisant ainsi le développement d'une réponse anti-tumeur mémoire durable. Ces observations pourraient être utiles au développement de nouveau vaccins thérapeutiques contre les tumeurs.
Resumo:
Le nombre d'examens tomodensitométriques (Computed Tomography, CT) effectués chaque année étant en constante augmentation, différentes techniques d'optimisation, dont les algorithmes de reconstruction itérative permettant de réduire le bruit tout en maintenant la résolution spatiale, ont étés développées afin de réduire les doses délivrées. Le but de cette étude était d'évaluer l'impact des algorithmes de reconstruction itérative sur la qualité image à des doses effectives inférieures à 0.3 mSv, comparables à celle d'une radiographie thoracique. Vingt CT thoraciques effectués à cette dose effective ont été reconstruits en variant trois paramètres: l'algorithme de reconstruction, rétroprojection filtrée versus reconstruction itérative iDose4; la matrice, 5122 versus 7682; et le filtre de résolution en densité (mou) versus spatiale (dur). Ainsi, 8 séries ont été reconstruites pour chacun des 20 CT thoraciques. La qualité d'image de ces 8 séries a d'abord été évaluée qualitativement par deux radiologues expérimentés en aveugle en se basant sur la netteté des parois bronchiques et de l'interface entre le parenchyme pulmonaire et les vaisseaux, puis quantitativement en utilisant une formule de merit, fréquemment utilisée dans le développement de nouveaux algorithmes et filtres de reconstruction. La performance diagnostique de la meilleure série acquise à une dose effective inférieure à 0.3 mSv a été comparée à celle d'un CT de référence effectué à doses standards en relevant les anomalies du parenchyme pulmonaire. Les résultats montrent que la meilleure qualité d'image, tant qualitativement que quantitativement a été obtenue en utilisant iDose4, la matrice 5122 et le filtre mou, avec une concordance parfaite entre les classements quantitatif et qualitatif des 8 séries. D'autre part, la détection des nodules pulmonaires de plus de 4mm étaient similaire sur la meilleure série acquise à une dose effective inférieure à 0.3 mSv et le CT de référence. En conclusion, les CT thoraciques effectués à une dose effective inférieure à 0.3 mSv reconstruits avec iDose4, la matrice 5122 et le filtre mou peuvent être utilisés avec confiance pour diagnostiquer les nodules pulmonaires de plus de 4mm.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.