162 resultados para vein wall


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS: Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS: The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION: MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different embolic materials for portal vein embolization (PVE) were evaluated. Twenty pigs received left and median PVE. Hydrophilic phosphorylcholine, N-butyl cyanoacrylate, hydrophilic gel, and polyvinyl alcohol (PVA) particles measuring either 50-150 microm or 700-900 microm were used in five pigs each. Portography and portal vein pressure measurement were performed before, immediately after PVE, and before being euthanized at day 7. Tissue wedges from embolized, and non-embolized liver were obtained for pathology. After complete embolization, recanalization occurred at 7 days in one gel and one 700-900 PVA embolization. Post-PVE increase in portal pressure was found in all groups (p = 0.01). The area of the hepatic lobules in non-embolized liver was larger than in the embolized liver in all groups (p = 0.001). The ratios of the areas between non-embolized/embolized livers were 1.65, 2.19, 1.57, and 1.32 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively; the ratios of fibrosis between the embolized and non-embolized livers were 1.37, 3.01, 3.49, and 2.11 for gel, NBCA, 50-150 PVA and 700-900 PVA, respectively. Hepatic lobules in non-embolized liver were significantly larger with NBCA than in other groups (p = 0.01). Fibrosis in embolized liver was significantly higher for NBCA and 50-150 PVA (p = 0.002). The most severe changes in embolized and non-embolized liver were induced by 50-150 PVA and NCBA PVE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM OF THE STUDY: To analyse the course of upper limb edema in patients with an arteriovenous fistula used for dialysis and to analyse the available therapeutic options. STUDY DESIGN: Retrospective study of patients with this type of edema, who were treated in our institution from 1992 to 1996. PATIENTS AND METHODS: Seven consecutive patients with an arterioveinous fistula treated for edema of the upper extremity, were reviewed. The fistula was created at the elbow in 6 patients and at the forearm in 1. The edema appeared immediately after operation in 4 patients and after a delay in 3 patients. Stenosis (3 patients) or occlusion (2 patients) of the subclavian vein was documented in 5 patients who were investigated by angiography. RESULTS: The edema regressed spontaneously in 4 patients because collaterals developed in 3 patients, and the fistula thrombosed in 1 patient. Surgical intervention allowed regression of the edema in the other 3 patients: excessive output of the fistula was reduced in 2 patients and an axillojugular bypass was performed in 1 patient. The fistula remained effective in 6 patients. Another fistula was performed on the contralateral arm in 1 patient. CONCLUSION: Non-operative management is recommended in patients who develop edema immediately after creation of the fistula, because spontaneous regression is likely. Measures aimed at reducing the output of the fistula or enhancing the venous capacities of the arm are required when edema appears at a later stage. The fistula can be saved in the majority of cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a technique aimed at establishing a noninvasive test for the assessment of significant coronary stenoses. There are certain boundary conditions that have hampered the clinical success of coronary MRA and coronary vessel wall imaging. Recent advances in hardware and software allow for consistent visualization of the proximal and mid portions of the native coronary arteries. Current research focuses on the use of intravascular MR contrast agents and black blood coronary angiography. One common goal is to create a noninvasive test which might allow for screening for major proximal and mid coronary artery disease. These novel approaches will represent a major step forward in diagnostic cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary MR imaging is a promising noninvasive technique for the combined assessment of coronary artery anatomy and function. Anomalous coronary arteries and aneurysms can reliably be assessed in clinical practice using coronary MR imaging and the presence of significant left main or proximal multivessel coronary artery disease detected. Technical challenges that need to be addressed are further improvements in motion suppression and abbreviated scanning times aimed at improving spatial resolution and patient comfort. The development of new and specific contrast agents, high-field MR imaging with improved spatial resolution, and continued progress in MR imaging methods development will undoubtedly lead to further progress toward the noninvasive and comprehensive assessment of coronary atherosclerotic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activation of the hepatoportal glucose sensors by portal glucose infusion leads to increased glucose clearance and induction of hypoglycemia. Here, we investigated whether glucagon-like peptide-1 (GLP-1) could modulate the activity of these sensors. Mice were therefore infused with saline (S-mice) or glucose (P-mice) through the portal vein at a rate of 25 mg/kg. min. In P-mice, glucose clearance increased to 67.5 +/- 3.7 mg/kg. min as compared with 24.1 +/- 1.5 mg/kg. min in S-mice, and glycemia decreased from 5.0 +/- 0.1 to 3.3 +/- 0.1 mmol/l at the end of the 3-h infusion period. Coinfusion of GLP-1 with glucose into the portal vein at a rate of 5 pmol/kg. min (P-GLP-1 mice) did not increase the glucose clearance rate (57.4 +/- 5.0 ml/kg. min) and hypoglycemia (3.8 +/- 0.1 mmol/l) observed in P-mice. In contrast, coinfusion of glucose and the GLP-1 receptor antagonist exendin-(9-39) into the portal vein at a rate of 0.5 pmol/kg. min (P-Ex mice) reduced glucose clearance to 36.1 +/- 2.6 ml/kg. min and transiently increased glycemia to 9.2 +/- 0.3 mmol/l at 60 min of infusion before it returned to the fasting level (5.6 +/- 0.3 mmol/l) at 3 h. When glucose and exendin-(9-39) were infused through the portal and femoral veins, respectively, glucose clearance increased to 70.0 +/- 4.6 ml/kg. min and glycemia decreased to 3.1 +/- 0.1 mmol/l, indicating that exendin-(9-39) has an effect only when infused into the portal vein. Finally, portal vein infusion of glucose in GLP-1 receptor(-/-) mice failed to increase the glucose clearance rate (26.7 +/- 2.9 ml/kg. min). Glycemia increased to 8.5 +/- 0.5 mmol/l at 60 min and remained elevated until the end of the glucose infusion (8.2 +/- 0.4 mmol/l). Together, our data show that the GLP-1 receptor is part of the hepatoportal glucose sensor and that basal fasting levels of GLP-1 sufficiently activate the receptor to confer maximum glucose competence to the sensor. These data demonstrate an important extrapancreatic effect of GLP-1 in the control of glucose homeostasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testosterone can benefit individual fitness by increasing ornament colour, aggressiveness, and sperm quality, but it can also impose both metabolic and immunological costs. However, evidence that testosterone causes immuno suppression in freely living populations is scant. We studied the effects of testosterone on one component of the immune system (i.e., the cell-mediated response to phytohaemagglutinin), parasite load, and metabolic rate in the common wall lizard, Podarcis muralis (Laurenti, 1768). For analyses of immunocompetence and parasitism, male lizards were implanted at the end of the breeding season with either empty or testosterone implants and were returned to their site of capture for 5-6 weeks before recapture. For analyses of the effects of testosterone on metabolic rate, male lizards were captured and implanted before hibernation and were held in the laboratory for 1 week prior to calorimetry. Experimental treatment with testosterone decreased the cell-mediated response to the T-cell mitogen phytohemagglutinin and increased mean metabolic rate. No effects of testosterone on the number of ectoparasites, hemoparasites, and resting metabolic rate could be detected. These results are discussed in the framework of the immunocompetence handicap hypothesis and the immuno-redistribution process hypothesis. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The metasomatism observed in the oceanic and continental lithosphere is generally interpreted to represent a continuous differentiation process forming anhydrous and hydrous veins plus a cryptic enrichment in the surrounding peridotite. In order to constrain the mechanisms of vein formation and potentially clarify the nature and origin of the initial metasomatic agent, we performed a series of high-pressure experiments simulating the liquid line of descent of a basanitic magma differentiating within continental or mature oceanic lithosphere. This series of experiments has been conducted in an end-loaded piston cylinder apparatus starting from an initial hydrous ne-normative basanite at 1.5 GPa and temperature varying between 1,250 and 980°C. Near-pure fractional crystallization process was achieved in a stepwise manner in 30°C temperature steps and starting compositions corresponding to the liquid composition of the previous, higher-temperature glass composition. Liquids evolve progressively from basanite to peralkaline, aluminum-rich compositions without significant SiO2 variation. The resulting cumulates are characterized by an anhydrous clinopyroxene + olivine assemblage at high temperature (1,250-1,160°C), while at lower temperature (1,130-980°C), hydrous cumulates with dominantly amphibole + minor clinopyroxene, spinel, ilmenite, titanomagnetite and apatite (1,130-980°C) are formed. This new data set supports the interpretation that anhydrous and hydrous metasomatic veins could be produced during continuous differentiation processes of primary, hydrous alkaline magmas at high pressure. However, the comparison between the cumulates generated by the fractional crystallization from an initial ne-normative liquid or from hy-normative initial compositions (hawaiite or picrobasalt) indicates that for all hydrous liquids, the different phases formed upon differentiation are mostly similar even though the proportions of hydrous versus anhydrous minerals could vary significantly. This suggests that the formation of amphibole-bearing metasomatic veins observed in the lithospheric mantle could be linked to the differentiation of initial liquids ranging from ne-normative to hy-normative in composition. The present study does not resolve the question whether the metasomatism observed in lithospheric mantle is a precursor or a consequence of alkaline magmatism; however, it confirms that the percolation and differentiation of a liquid produced by a low degree of partial melting of a source similar or slightly more enriched than depleted MORB mantle could generate hydrous metasomatic veins interpreted as a potential source for alkaline magmatism by various authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).