163 resultados para vein insufficiency, saphenous vein surgery, duplex study, varicose ulcer.


Relevância:

100.00% 100.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Intimal hyperplasia (IH) is a vascular remodeling process which often leads to failure of arterial bypass or hemodialysis access. Experimental and clinical work have provided insight in IH development; however, further studies under precise controlled conditions are required to improve therapeutic strategies to inhibit IH development. Ex vivo perfusion of human vessel segments under standardized hemodynamic conditions may provide an adequate experimental approach for this purpose. Therefore, chronically perfused venous segments were studied and compared to traditional static culture procedures with regard to functional and histomorphologic characteristics as well as gene expression. MATERIALS AND METHODS: Static vein culture allowing high tissue viability was performed as previously described. Ex vivo vein support system (EVVSS) was performed using a vein support system consisting of an incubator with a perfusion chamber and a pump. EVVSS allows vessel perfusion under continuous flow while maintaining controlled hemodynamic conditions. Each human saphenous vein was divided in two parts, one cultured in a Pyrex dish and the other part perfused in EVVSS for 14days. Testing of vasomotion, histomorphometry, expression of CD 31, Factor VIII, MIB 1, alpha-actin, and PAI-l were determined before and after 14days of either experimental conditions. RESULTS: Human venous segments cultured under traditional or perfused conditions exhibited similar IH after 14 days as shown by histomorphometry. Smooth-muscle cell (SMC) was preserved after chronic perfusion. Although integrity of both endothelial and smooth-muscle cells appears to be maintained in both culture conditions as confirmed by CD31, factor VIII, and alpha-actin expression, a few smooth-muscle cells in the media stained positive for factor VIII. Cell-proliferation marker MIB-1 was also detected in the two settings and PAI-1 mRNA expression and activity increased significantly after 14 days of culture and perfusion. CONCLUSION: This study demonstrates the feasibility to chronically perfuse human vessels under sterile conditions with preservation of cellular integrity and vascular contractility. To gain insights into the mechanisms leading to IH, it will now be possible to study vascular remodeling not only under static conditions but also in hemodynamic environment mimicking as closely as possible the flow conditions encountered in reconstructive vascular surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Résumé de l'article : L'hyperplasie intimale est un processus de remodelage vasculaire ubiquitaire après une lésion, pouvant menacer la perméabilité de tout type de reconstruction vasculaire. Les mécanismes physiopathologiques impliqués dans le développement de l'hyperplasie intimale ne sont que partiellement élucidés. Il est par conséquent nécessaire d'effectuer des recherches complémentaires afin d'en améliorer la compréhension et ainsi permettre l'élaboration de nouvelles stratégies thérapeutiques médicamenteuses. La culture de veines en milieu statique permet le développement de l'hyperplasie intimale. Ce modèle maintient la viabilité tissulaire, comme décrit précédemment dans d'autres études, mais empêche l'analyse des paramètres hémodynamiques. La mise au point d'un modèle de perfusion in vitro permettant la perfusion de segments vasculaires représente une approche expérimentale intégrant les différents facteurs hémodynamiques. Le système de perfusion (Ex Vivo Vein Support System) que nous avons élaboré conserve l'intégrité pariétale ainsi que les propriétés vasomotrices des veines pour une durée de 14 jours. Cette étude démontre que les deux modèles permettent le développement de l'hyperplasie intimale. Toutefois, les propriétés vasomotrices ainsi que l'influence des paramètres hémodynamiques ne peuvent être analysées que par l'utilisation du système de perfusion. Ce dernier a permis de perfuser des vaisseaux humains sans contamination bactérienne tout en maintenant l'intégrité cellulaire. Ce modèle de perfusion se rapproche plus des conditions hémodynamiques rencontrées in vivo que le modèle statique. Abstract : Background. Intimal hyperplasia (IH) is a vascular remodeling process which often leads to failure of arterial bypass or hemodialysis access. Experimental and clinical work have provided insight in IH development; however, further studies under precise con-trolled conditions are required to improve therapeutic strategies to inhibit IH development. Ex vivo perfusion of human vessel segments under standardized hemodynamic conditions may provide an adequate experimental approach for this purpose. Therefore, chronically perfused venous segments were studied and compared to traditional static culture procedures with regard to functional and histomorphologic characteristics as well as gene expression. Materials and methods. Static vein culture allowing high tissue viability was performed as previously described. Ex vivo vein support system (EVVSS) was performed using a vein support system consisting of an incubator with a perfusion chamber and a pump. EVVSS allows vessel perfusion under continuous flow while maintaining controlled hemodynamic conditions. Each human saphenous vein was divided in two parts, one cultured in a Pyrex dish and the other part perfused in EVVSS for 14 days. Testing of vasomotion, histomorphometry, expression of CD 31, Factor VIII, MIB 1, α-actin, and PAI-1 were determined before and after 14 days of either experimental conditions. Results, Human venous segments cultured under traditional or perfused conditions exhibited similar IH after 14 days as shown by histomorphometry. Smooth-muscle cell ( SMC) was preserved after chronic perfusion. Although integrity of both endothelial and smooth-muscle cells appears to be maintained in both culture conditions as confirmed by CD31, factor VIII and α-actin expression, a few smooth-muscle cells in the media stained positive for factor VIII. Cell-proliferation marker MIB-1 was also detected in the two settings and PAI-1 mRNA expression and activity increased significantly after 14 days of culture and perfusion. Conclusion. This study demonstrates the feasibility to chronically perfuse human vessels under sterile conditions with preservation of cellular integrity and vascular contractility. To gain insights into the mechanisms leading to IH, it will now be possible to study vascular remodeling not only under static conditions but also in hemodynamic environment mimicking as closely as possible the flow conditions encountered in reconstructive vascular surgery.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and compare the benefits of endoscopic saphenous vein harvesting (EVH) with the traditional incision technique (TIT) for coronary artery bypass grafting (CABG) in respect to the technical procedure and clinical outcome. In a prospective nonrandomized, case-matched study the greater saphenous vein was harvested for CABG in 22 patients using the endoscopic technique and in 18 patients with the traditional method. Comparisons were made for the operating time, length of incision and vein harvested, graft quality, postoperative complications, and pain assessment. Patient demographics were well matched. EVH required smaller incisions than did the TIT (10.5 +/- 6.6 vs. 31.2 +/- 7.8 cm, respectively; p < 0.0001). Harvest time and vein quality were comparable in the two groups. Total vein operating time was shorter following the endoscopic technique (60 +/- 24 vs. 100 +/- 35 minutes, respectively; p < 0.0001). EVH had fewer complications (NS), and postoperative pain was significantly less (p = 0.0034). The major advantages of endoscopic vein harvesting are a significant reduction of postoperative pain and strikingly better cosmetic results. Wound complications seem to be less frequent.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy. DESIGN: A retrospective study over a 20-month period from a single centre. PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included. METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage. RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation. CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To demonstrate successful in situ aortoiliac reconstruction of an infected infrarenal aneurysm using one single superficial femoral vein (SFV). Methods: In situ reconstruction using the right SFV sutured in end-to-end anastomosis with the aorta and distally with the right common iliac artery and in end-to-side anastomosis with the left common iliac artery. Results: The operating time was less than reported for aortic in situ reconstruction with bilateral SFV harvesting. The duplex scan 3 months postoperatively showed permeability of the bypass without any anastomotic stenosis or pseudoaneurysm. The right common femoral, popliteal, and greater saphenous veins were patent without thrombus, and the patient did not complain about peripheral edema. Conclusions: The use of only one instead of both the SFVs for aortobiiliac in situ reconstruction might be a way to reduce operating time and allow autogenous venous reconstruction even in patients with limited availability of venous material.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: This study aims to assess the predictive value of residual venous obstruction (RVO) for recurrent venous thrombo-embolism (VTE) in a study using D-dimer to predict outcome. DESIGN: This is a multicentre randomised open-label study. METHODS: Patients with a first episode of idiopathic VTE were enrolled on the day of anticoagulation discontinuation when RVO was determined by compression ultrasonography in those with proximal deep vein thrombosis (DVT) of the lower limbs. D-dimer was measured after 1 month. Patients with normal D-dimer did not resume anticoagulation while patients with abnormal D-dimer were randomised to resume anticoagulation or not. The primary outcome measure was recurrent VTE over an 18-month follow-up. RESULTS: A total of 490 DVT patients were analysed (after excluding 19 for different reasons and 118 for isolated pulmonary embolism (PE)). Recurrent DVT occurred in 19% (19/99) of patients with abnormal D-dimer who did not resume anticoagulation and 10% (31/310) in subjects with normal D-dimer (adjusted hazard ratio: 2.1; p = 0.02). Recurrences were similar in subjects either with (11%, 17/151) or without RVO (13%, 32/246). Recurrent DVT rates were also similar for normal D-dimer, with or without RVO, and for abnormal D-dimer, with or without RVO. CONCLUSIONS: Elevated D-dimer at 1 month after anticoagulation withdrawal is a risk factor for recurrence, while RVO at the time of anticoagulation withdrawal is not.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The in situ saphenous vein bypass has been introduced in our department since 1989. A total of 26 bypasses in 22 patients have been followed prospectively. Indications for revascularisation have been severe arterial insufficiency in 73% of the cases (stage III or IV). With the exception of one postoperative death (myocardial infarction), all the patients have recovered uneventfully, with a regression to stage I. No amputation has been necessary. Morbidity has been 30%, with mainly minor local complications. The primary patency rate is 83% at one year and 78% after 2 and 3 years, whereas the secondary patency rate is 91% at one year, and remains constant thereafter up to 3 years. Considering our results and those from the literature, we believe that the in situ technique is very valuable, especially for below-knee vascular reconstruction. Technical difficulties of the method are analysed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Saphenous vein graft bypass remains the salvage option when¦endovascular procedure has failed or was contraindicated due to extensive¦occlusive lesions. However, pathological wall remodeling leading leading to¦graft failure is one of the most limiting factors of this therapy. Therefore, the¦understanding of this remodeling process of human vein is essential to the design¦of future effective therapeutics and it requires an adapted model of ex-vivo vein¦perfusion.¦Methods: We have developed an ex vivo vein support system (EVVSS), which¦uses standardized and controlled hemodynamic parameters for the pulsatile¦perfusion of saphenous vein segments. The morphological and molecular¦parameters involved in the remodeling process under an arterial shear stress¦associated to low (7 mm Hg) or high (70 mm Hg) pressure conditions can be¦analyzed.¦Results: Histomorphometric analysis showed that the vein segments perfused¦during 7 days under high pressure undergo a significant neointima development¦compared to veins exposed to low pressure conditions. The application of an¦arterial shear stress in the vein under low pressure induced an elevation of the¦MMP-2 and MMP-9 expression, activity and transcription. The application of¦higher pressure is associated to increased MMP2 expression and transcription¦and MMP9 transcription. TIMP1 expression and transcription were initiated by¦the application of an arterial shear stress but not modified by the modification¦of the pressure. However, TIMP2 expression was increased under high¦pressure conditions but its transcription was inhibited by arterial shear stress,¦independently of the pressure. The values of transcription and expression of¦PAI-1 were not modified by high pressure. Eph-B4 transcription and expression¦were significantly decreased under arterial shear stress.¦Conclusion: These data show that our EVVSS is a valuable setting to study¦ex vivo remodeling of human saphenous veins submitted to arterial conditions.¦The intimal hyperplasia as well as MMP 2, 9 and TIMP 2 seem to be influenced¦by the pressure.

Relevância:

60.00% 60.00%

Publicador: