221 resultados para unit groups


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In order to improve safety of pedicle screw placement several techniques have been developed. More recently robotically assisted pedicle insertion has been introduced aiming at increasing accuracy. The aim of this study was to compare this new technique with the two main pedicle insertion techniques in our unit namely fluoroscopically assisted vs EMG aided insertion. Material and methods: A total of 382 screws (78 thoracic,304 lumbar) were introduced in 64 patients (m/f = 1.37, equally distributed between insertion technique groups) by a single experienced spinal surgeon. From those, 64 (10 thoracic, 54 lumbar) were introduced in 11 patients using a miniature robotic device based on pre operative CT images under fluoroscopic control. 142 (4 thoracic, 138 lumbar) screws were introduced using lateral fluoroscopy in 27 patients while 176 (64 thoracic, 112 lumbar) screws in 26 patients were inserted using both fluoroscopy and EMG monitoring. There was no difference in the distribution of scoliotic spines between the 3 groups (n = 13). Screw position was assessed by an independent observer on CTs in axial, sagittal and coronal planes using the Rampersaud A to D classification. Data of lumbar and thoracic screws were processed separately as well as data obtained from axial, sagittal and coronal CT planes. Results: Intra- and interobserver reliability of the Rampersaud classification was moderate, (0.35 and 0.45 respectively) being the least good on axial plane. The total number of misplaced screws (C&D grades) was generally low (12 thoracic and 12 lumbar screws). Misplacement rates were same in straight and scoliotic spines. The only difference in misplacement rates was observed on axial and coronal images in the EMG assisted thoracic screw group with a higher proportion of C or D grades (p <0.05) in that group. Recorded compound muscle action potentials (CMAP) values of the inserted screws were 30.4 mA for the robot and 24.9mA for the freehand technique with a CI of 3.8 of the mean difference of 5.5 mA. Discussion: Robotic placement did improve the placement of thoracic screws but not that of lumbar screws possibly because our misplacement rates in general near that of published navigation series. Robotically assisted spine surgery might therefore enhance the safety of screw placement in particular in training settings were different users at various stages of their learning curve are involved in pedicle instrumentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Résumé de l'ouvrage) This volume contains the papers presented at the 47th Colloquium Biblicum Lovaniense (Leuven, 1998). The general theme of the meeting was the unity of the Gospel of Luke and the Acts of the Apostles. Main papers on this topic were read by R.L. Brawley, J. Delobel, A. Denaux, J.A. Fitzmeyer, F.W. Horn, J. Kremer, A. Lindemann, O. Mainville, D. Marguerat, F. Neirynck, W. Radl, M. Rese, J. Taylor, C.M. Tuckett, and J. Verheyden. While a large majority of scholars agree that Luke intended his work to cover both the past and the continuing history of Jesus (Gospel and Acts), the essays also illustrate the complexities of this view on the unity of Luke-Acts when it comes to interpret the various aspects of Lukan theology, christology, pneumatology, and ecclesiology, the expansion of the Church in light of its Jewish origins, the genre of Luke-Acts, and the literary and stylistic means Luke used to make his work a unity. In total the volume includes some 40 papers, of which 24 are offered papers: L. Alexander, H. Baarlink, M. Bachmann, D. Bechard, T.L. Brodie, G.P. Carras, A. del Agua, C. Focant, G. Geiger, B.J. Koet, V. Koperski, D.P. Moessner, G. Oegema, J. Pichler, E. Plümacher, A. Puig i Tarrèch, U. Schmid, B. Schwank, N. Taylor, P.J. Tomson, S. Van den Eynde, S. Walton, G. Wasserberg, F. Wilk. This collection is an invaluable contribution to current discussions in Lukan study and to a nuanced understanding of the relationship between Luke's two volumes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Evaluation of the clinical impact of multiple infections of the cervix by human papillomavirus, including human papillomavirus-16, compared with single human papillomavirus-16 infection. STUDY DESIGN: One hundred sixty-nine women were classified in 3 categories depending on their human papillomavirus profile: human papillomavirus-16 only, human papillomavirus-16 and low-risk type(s), and human papillomavirus-16 and other high-risk type(s). Cervical brush samples were analyzed for human papillomavirus DNA by polymerase chain reaction and reverse line blot hybridization. All women were evaluated with colposcopy during 24 months or more. Management was according to the Bethesda recommendations. RESULTS: Women infected with human papillomavirus-16 and other high-risk human papillomavirus type(s) presented more progression or no change in the grade of dysplasia, compared with women of the other groups (relative risk [RR], 1.39; 95% confidence interval [CI], 1.07-1.82; P = .02 at 6 months; RR, 2.10; 95% CI, 1.46-3.02; P < .001 at 12 months; RR, 1.82; 95% CI, 1.21-2.72; P = .004 at 24 months). CONCLUSION: Coinfection of women with human papillomavirus-16 and other high-risk human papillomavirus type(s) increases the risk of unfavorable evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to compare the mechanical external work (per kg) and pendular energy transduction at preferred walking speed (PWS) in obese versus normal body mass subjects to investigate whether obese adults adopt energy conserving gait mechanics. METHODS: The mechanical external work (Wext) and the fraction of mechanical energy recovered by the pendular mechanism (Rstep) were computed using kinematic data acquired by an optoelectronic system and were compared in 30 obese (OG; body mass index [BMI] = 39.6 +/- 0.6 kg m(-2); 29.5 +/- 1.3 yr) and 19 normal body mass adults (NG; BMI = 21.4 +/- 0.5 kg m(-2); 31.2 +/- 1.2 yr) walking at PWS. RESULTS: PWS was significantly lower in OG (1.18 +/- 0.02 m s(-1)) than in NG (1.33 +/- 0.02 m s(-1); P <or= 0.001). There was no significant difference in Wext per unit mass between groups (OG: 0.36 +/- 0.03 J kg(-1) m(-1); NG: 0.31 +/- 0.02 J kg(-1) m(-1); P = 0.12). Rstep was significantly lower in OG (68.4% +/- 2.0%) compared with NG (74.4% +/- 1.0%; P = 0.01). In OG only, Wext per unit mass was positively correlated with PWS (r = 0.57; P < 0.001). CONCLUSION: Obese adults do not appear to alter their gait to improve pendular energy transduction and may select slower PWS to reduce mechanical and metabolic work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suicidal behaviour among young people represents a major public health problem. This study seeks to compare the major sociological, clinical, schooling and family features of suicidal and non-suicidal subgroups of adolescents hospitalised in the Health Foundation Center for French Students of neufmoutiers en Brie (France). All these adolescents suffered from the severe mental disorders. The adolescents from the suicidal subgroup presented significantly fewer psychoses and more mood disorders than those of the non-suicidal subgroup. Half of the patients from the suicidal subgroup presented some features of personality disorders, mostly borderline personality disorders. Nevertheless, their global functioning was more frequently improved between admission and discharge than was the case for the non-suicidal group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of back pain patients refers to the biopsychosocial model of care. This model includes illness in patient's personal and relational life. In this context, it is not only the physical symptom of the patient which is focused but also his psychological distress often hidden by algic complain. Clinical interviews conducted with back pain patients have highlighted psychosocial aspects able to influence the relationship between health care user and provider. Taking account of psychosocial aspects implies an interdisciplinary approach that identify and assesses patients' needs through adequate tools. As a result, the different health care providers implied with back pain patients have to collaborate in a structured network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.