140 resultados para testis volume


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary artery calcification (CAC) is quantified based on a computed tomography (CT) scan image. A calcified region is identified. Modified expectation maximization (MEM) of a statistical model for the calcified and background material is used to estimate the partial calcium content of the voxels. The algorithm limits the region over which MEM is performed. By using MEM, the statistical properties of the model are iteratively updated based on the calculated resultant calcium distribution from the previous iteration. The estimated statistical properties are used to generate a map of the partial calcium content in the calcified region. The volume of calcium in the calcified region is determined based on the map. The experimental results on a cardiac phantom, scanned 90 times using 15 different protocols, demonstrate that the proposed method is less sensitive to partial volume effect and noise, with average error of 9.5% (standard deviation (SD) of 5-7mm(3)) compared with 67% (SD of 3-20mm(3)) for conventional techniques. The high reproducibility of the proposed method for 35 patients, scanned twice using the same protocol at a minimum interval of 10 min, shows that the method provides 2-3 times lower interscan variation than conventional techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Da Bisanzio alla Santa Russia Résumé Ivan Foletti Le texte du premier volume de YIkonografija Bogomatri (Iconographie de la mère de Dieu), publié en 1914 à Saint Pétersbourg par Nikodim Kondakov et traduit dans le cadre de ce travail, soulève chez le lecteur contemporain de nombreuses questions quant au développement des études byzantines, entre la fin du XIXe et le début du XXe siècle. Il s'agit, avant tout, de comprendre les enjeux fondamentaux de la naissance de cette discipline, dans le cadre de l'Europe romantique et plus particulièrement de son acculturation à la réalité russe. En se concentrant sur le personnage de Nikodim Kondakov, considéré par ses contemporains comme le patriarche des études byzantines, ce travail propose d'articuler la réflexion autour de deux axes principaux. Il s'agit d'une part de la relation entre histoire de l'art et société : dans le contexte russe et plus largement dans celui de l'Europe, la recherche semble se développer en étroite relation avec les tendances politiques et sociales de ces années. C'est probablement la raison du choix pour Nikodim Kondakov de se dédier aux études de Byzance, dans les années où la Russie prépare sa guerre contre la Turquie (1877-1878), tandis que l'opinion publique est martelée avec un revival de l'ancienne idéologie de Moscou comme « troisième Rome » et héritière de Byzance. Un autre aspect significatif est la décision de ce même chercheur d'étudier les antiquités russes sous le règne de Alexandre III, le tzar « contre-réformateur », quand la Russie se replie sur elle même autour de trois mots d'ordre: Orthodoxie, autocratie, et nationalité. D'autre part, la réception de Kondakov en Occident, semble aussi dépendre de questions politiques. Son accueil très favorable en France et en Angleterre contraste avec une perception bien plus négative en Autriche et en Allemagne ; il s'agit là d'une position en étonnante harmonie avec les traités politiques - l'alliance franco-russe de 1891 et la triple entente de 1911 qui opposent les pays membres aux empires centraux. Le deuxième axe considéré est celui d'une analyse systématique de la naissance des études sur les images cultuelles russes, les icônes. Les pages dédiées à ce phénomène dans Γ Ikonograflja Bogomatri, mais également dans les autres ouvrages de Kondakov, posent clairement la question des raisons nationalistes et populistes de la redécouverte, autour de 1900, en Russie et en Europe de cette expression visuelle. Conclusion logique de la tradition historiographique du XIXe siècle - qui s'est préoccupé des icônes perçues comme documents historiques - cette nouvelle vague d'intérêt pose la question de l'icône commé"oeuvre d'art. C'est autour de ce débat, alimenté également par l'apparition des avant-gardes, que se situent les plus importants savants russes de ces années en opposant deux manières radicalement différentes de percevoir l'art : à l'approche positiviste s'oppose celle d'un renouveau d'Hegel. Ce débat sera brusquement interrompu par la révolution, suivie par les années staliniennes qui vont définitivement « discerner » laquelle des deux méthodes et approches est la « juste », en congelant de fait, pour des décennies, toute possibilité de discussion. Cette thèse souhaiterait donc ouvrir en Occident un débat pour l'instant marginal dans les études : celui de la naissance d'une histoire de l'art moderne en Russie, mais également de l'émergence d'une nouvelle Europe savante autour de 1900 où l'histoire de l'art byzantin s'affirme comme un domaine émergent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Black-blood fast spin-echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold-over artifacts, using a sufficiently large field of view in phase-encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner-volume approach, the combination of a black-blood fast spin-echo sequence with a two-dimensionally selective radiofrequency pulse is proposed for selective "local excitation" small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user-specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel hybrid (or multiphysics) algorithm, which couples pore-scale and Darcy descriptions of two-phase flow in porous media. The flow at the pore-scale is described by the Navier?Stokes equations, and the Volume of Fluid (VOF) method is used to model the evolution of the fluid?fluid interface. An extension of the Multiscale Finite Volume (MsFV) method is employed to construct the Darcy-scale problem. First, a set of local interpolators for pressure and velocity is constructed by solving the Navier?Stokes equations; then, a coarse mass-conservation problem is constructed by averaging the pore-scale velocity over the cells of a coarse grid, which act as control volumes; finally, a conservative pore-scale velocity field is reconstructed and used to advect the fluid?fluid interface. The method relies on the localization assumptions used to compute the interpolators (which are quite straightforward extensions of the standard MsFV) and on the postulate that the coarse-scale fluxes are proportional to the coarse-pressure differences. By numerical simulations of two-phase problems, we demonstrate that these assumptions provide hybrid solutions that are in good agreement with reference pore-scale solutions and are able to model the transition from stable to unstable flow regimes. Our hybrid method can naturally take advantage of several adaptive strategies and allows considering pore-scale fluxes only in some regions, while Darcy fluxes are used in the rest of the domain. Moreover, since the method relies on the assumption that the relationship between coarse-scale fluxes and pressure differences is local, it can be used as a numerical tool to investigate the limits of validity of Darcy's law and to understand the link between pore-scale quantities and their corresponding Darcy-scale variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An 18-year-old man presented with a growing painless left scrotal mass. Sonography showed a hydrocele and a homogeneous, well-encapsulated left extratesticular mass with similar echogenicity as the normal testis, suggestive of a splenogonadal fusion. To substantiate the diagnosis, the patient underwent Tc-99m heat-denatured red blood cell scintigraphy showing normal physiological hyperactivity in the spleen but activity similar to the blood pool projecting on the upper part of the left testis. This made testicular splenic tissue less likely. The patient underwent resection and histopathology revealed a well-differentiated papillary mesothelioma. Inguinal orchidectomy was subsequently performed and the patient was free of recurrence at 18 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) is a new ventilatory mode in which ventilator settings are adjusted based on the electrical activity detected in the diaphragm (Eadi). This mode offers significant advantages in mechanical ventilation over standard pressure support (PS) modes, since ventilator input is determined directly from patient ventilatory demand. Therefore, it is expected that tidal volume (Vt) under NAVA would show better correlation with Eadi compared with PS, and exhibit greater variability due to the variability in the Eadi input to the ventilator. OBJECTIVES. To compare tidal volume variability in PS and NAVA ventilation modes, and its correlation with patient ventilatory demand (as characterized by maximum Eadi). METHODS. Acomparative study of patient-ventilator interaction was performed for 22 patients during standard PS with clinician determined ventilator settings; and NAVA, with NAVA gain set to ensure the same peak airway pressure as the total pressure obtained in PS. A 20 min continuous recording was performed in each ventilator mode. Respiratory rate, Vt, and Eadi were recorded. Tidal volume variance and Pearson correlation coefficient between Vt and Eadi were calculated for each patient. A periodogram was plotted for each ventilator mode and each patient, showing spectral power as a function of frequency to assess variability. RESULTS. Median, lower quartile and upper quartile values for Vt variance and Vt/Eadi correlation are shown in Table 1. The NAVA cohort exhibits substantially greater correlation and variance than the PS cohort. Power spectrums for Vt and Eadi are shown in Fig. 1 (PS and NAVA) for a typical patient. The enlarged section highlights how changes in Eadi are highly synchronized with NAVA ventilation, but less so for PS. CONCLUSIONS. There is greater variability in tidal volume and correlation between tidal volume and diaphragmatic electrical activity with NAVA compared to PS. These results are consistent with the improved patient-ventilator synchrony reported in the literature.