27 resultados para spectral reflectance
Resumo:
Understanding the influence of pore space characteristics on the hydraulic conductivity and spectral induced polarization (SIP) response is critical for establishing relationships between the electrical and hydrological properties of surficial unconsolidated sedimentary deposits, which host the bulk of the world's readily accessible groundwater resources. Here, we present the results of laboratory SIP measurements on industrial-grade, saturated quartz samples with granulometric characteristics ranging from fine sand to fine gravel, which can be regarded as proxies for widespread alluvial deposits. We altered the pore space characteristics by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples. In general, the results indicate a clear connection between the SIP response and the granulometric as well as pore space characteristics. In particular, we observe a systematic correlation between the hydraulic conductivity and the relaxation time of the Cole-Cole model describing the observed SIP effect for the entire range of considered grain sizes. The results do, however, also indicate that the detailed nature of these relations depends strongly on variations in the pore space characteristics, such as, for example, the degree of compaction. The results of this study underline the complexity of the origin of the SIP signal as well as the difficulty to relate it to a single structural factor of a studied sample, and hence raise some fundamental questions with regard to the practical use of SIP measurements as site- and/or sample-independent predictors of the hydraulic conductivity.
Resumo:
Fluorescence resonance energy transfer (FRET) allows the user to investigate interactions between fluorescent partners. One crucial issue when calculating sensitized emission FRET is the correction for spectral bleed-throughs (SBTs), which requires to calculate the ratios between the intensities in the FRET and in the donor or acceptor settings, when only the donor or acceptor are present. Theoretically, SBT ratios should be constant. However, experimentally, these ratios can vary as a function of fluorophore intensity, and assuming constant values may hinder precise FRET calculation. One possible cause for such a variation is the use of a microscope set-up with different photomultipliers for the donor and FRET channels, a set-up allowing higher speed acquisitions on very dynamic fluorescent molecules in living cells. Herein, we show that the bias introduced by the differential response of the two PMTs can be circumvented by a simple modeling of the SBT ratios as a function of fluorophore intensity. Another important issue when performing FRET is the localization of FRET within the cell or a population of cells. We hence developed a freely available ImageJ plug-in, called PixFRET, that allows a simple and rapid determination of SBT parameters and the display of normalized FRET images. The usefulness of this modeling and of the plug-in are exemplified by the study of FRET in a system where two interacting nuclear receptors labeled with ECFP and EYFP are coexpressed in living cells.
Resumo:
Understanding the influence of pore space characteristics on the hydraulic conductivity and spectral induced polarization (SIP) response is critical for establishing relationships between the electrical and hydrological properties of surficial sedimentary deposits. Here, we present the results of laboratory SIP measurements on saturated quartz samples with granulometric characteristics ranging from fine sand to fine gravel. We alter the pore characteristics using three principal methods: (i) variation of the grain sizes, (ii) changing the degree of compaction, and (iii) changing the level of sorting. We then examine how these changes affect both the SIP response and the hydraulic conductivity. In general, the results indicate a clear connection between the applied changes in pore characteristics and the SIP response. In particular, we observe a systematic correlation between the hydraulic conductivity and the relaxation time of the Cole-Cole model describing the observed SIP effect for the whole range of considered grain sizes.
Resumo:
In this paper, mixed spectral-structural kernel machines are proposed for the classification of very-high resolution images. The simultaneous use of multispectral and structural features (computed using morphological filters) allows a significant increase in classification accuracy of remote sensing images. Subsequently, weighted summation kernel support vector machines are proposed and applied in order to take into account the multiscale nature of the scene considered. Such classifiers use the Mercer property of kernel matrices to compute a new kernel matrix accounting simultaneously for two scale parameters. Tests on a Zurich QuickBird image show the relevance of the proposed method : using the mixed spectral-structural features, the classification accuracy increases of about 5%, achieving a Kappa index of 0.97. The multikernel approach proposed provide an overall accuracy of 98.90% with related Kappa index of 0.985.
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Resumo:
PURPOSE: To report the time course of retinal morphologic changes in a patient with acute retinal pigment epithelitis (ARPE) using spectral domain optical coherence tomography (SD-OCT). METHODS: A 30-year old man was referred for blurred vision of his right eye after five days that appeared suddenly 15 days after recovery from a flu-like syndrome. SD-OCT was performed immediately, followed by fluorescein and infracyanine angiography at eight days and then at three weeks. RESULTS: At presentation, a bubble of sub-macular deposit was observed on the right macula with central golden micronodules in a honeycomb pattern. SD-OCT showed an "anterior dislocation" of all the retinal layers up to the inner/outer segment (IS/OS) line and irregular deposits at the OS level together with thickening of the retinal pigment epithelial (RPE) layer. As visual acuity increased, eight days later, the OCT showed reduction of the sub-retinal deposits and an abnormal hyperflectivity of the sub-retinal and RPE layers was observed. The patient showed a positive serology for picornavirus. DISCUSSION: The acute SD-OCT sections of this patient with ARPE were compared with histological sections of a 35 day old Royal College of Surgeons rat. Similar findings could be observed, with preservation of the IS/OS line and accumulation of debris at the OS level, suggesting that ARPE symptoms could result from a transient phagocytic dysfunction of the RPE at the fovea, inducing reversible accumulation of undigested OS. Picornaviruses comprising enterovirus and coxsachievirus described as being associated with acute chorioretinitis. In this case, it was responsible for ARPE. CONCLUSION: We hypothesize that ARPE syndrome results from a transient dysfunction of RPE, which can occur as a post viral reaction.
Resumo:
Metastatic melanomas are frequently refractory to most adjuvant therapies such as chemotherapies and radiotherapies. Recently, immunotherapies have shown good results in the treatment of some metastatic melanomas. Immune cell infiltration in the tumor has been associated with successful immunotherapy. More generally, tumor infiltrating lymphocytes (TILs) in the primary tumor and in metastases of melanoma patients have been demonstrated to correlate positively with favorable clinical outcomes. Altogether, these findings suggest the importance of being able to identify, quantify and characterize immune infiltration at the tumor site for a better diagnostic and treatment choice. In this paper, we used Fourier Transform Infrared (FTIR) imaging to identify and quantify different subpopulations of T cells: the cytotoxic T cells (CD8+), the helper T cells (CD4+) and the regulatory T cells (T reg). As a proof of concept, we investigated pure populations isolated from human peripheral blood from 6 healthy donors. These subpopulations were isolated from blood samples by magnetic labeling and purities were assessed by Fluorescence Activated Cell Sorting (FACS). The results presented here show that Fourier Transform Infrared (FTIR) imaging followed by supervised Partial Least Square Discriminant Analysis (PLS-DA) allows an accurate identification of CD4+ T cells and CD8+ T cells (>86%). We then developed a PLS regression allowing the quantification of T reg in a different mix of immune cells (e.g. Peripheral Blood Mononuclear Cells (PBMCs)). Altogether, these results demonstrate the sensitivity of infrared imaging to detect the low biological variability observed in T cell subpopulations.
Resumo:
INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.
Resumo:
Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.