27 resultados para robotic welding
Resumo:
Neuroimaging of the self has focused on high-level mechanisms such as language, memory or imagery of the self and implicated widely distributed brain networks. Yet recent evidence suggests that low-level mechanisms such as multisensory and sensorimotor integration may play a fundamental role in self-related processing. In the present study we used visuotactile multisensory conflict, robotics, virtual reality, and fMRI to study such low-level mechanisms by experimentally inducing changes in self-location. Participants saw a video of a person's back (body) or an empty room (no-body) being stroked while a MR-compatible robotic device stroked their back. The latter tactile input was synchronous or asynchronous with respect to the seen stroking. Self-location was estimated behaviorally confirming previous data that self-location only differed between the two body conditions. fMRI results showed a bilateral activation of the temporo-parietal cortex with a significantly higher BOLD signal increase in the synchronous/body condition with respect to the other conditions. Sensorimotor cortex and extrastriate-body-area were also activated. We argue that temporo-parietal activity reflects the experience of the conscious 'I' as embodied and localized within bodily space, compatible with clinical data in neurological patients with out-of-body experiences.
Resumo:
BACKGROUND: Living in a multisensory world entails the continuous sensory processing of environmental information in order to enact appropriate motor routines. The interaction between our body and our brain is the crucial factor for achieving such sensorimotor integration ability. Several clinical conditions dramatically affect the constant body-brain exchange, but the latest developments in biomedical engineering provide promising solutions for overcoming this communication breakdown. NEW METHOD: The ultimate technological developments succeeded in transforming neuronal electrical activity into computational input for robotic devices, giving birth to the era of the so-called brain-machine interfaces. Combining rehabilitation robotics and experimental neuroscience the rise of brain-machine interfaces into clinical protocols provided the technological solution for bypassing the neural disconnection and restore sensorimotor function. RESULTS: Based on these advances, the recovery of sensorimotor functionality is progressively becoming a concrete reality. However, despite the success of several recent techniques, some open issues still need to be addressed. COMPARISON WITH EXISTING METHOD(S): Typical interventions for sensorimotor deficits include pharmaceutical treatments and manual/robotic assistance in passive movements. These procedures achieve symptoms relief but their applicability to more severe disconnection pathologies is limited (e.g. spinal cord injury or amputation). CONCLUSIONS: Here we review how state-of-the-art solutions in biomedical engineering are continuously increasing expectances in sensorimotor rehabilitation, as well as the current challenges especially with regards to the translation of the signals from brain-machine interfaces into sensory feedback and the incorporation of brain-machine interfaces into daily activities.
Resumo:
Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.
Resumo:
The goal of this study was to compare the quantity and purity of DNA extracted from biological tracesusing the QIAsymphony robot with that of the manual QIAamp DNA mini kit currently in use in ourlaboratory. We found that the DNA yield of robot was 1.6-3.5 times lower than that of the manualprotocol. This resulted in a loss of 8% and 29% of the alleles correctly scored when analyzing 1/400 and 1/800 diluted saliva samples, respectively. Specific tests showed that the QIAsymphony was at least 2-16times more efficient at removing PCR inhibitors. The higher purity of the DNA may therefore partlycompensate for the lower DNA yield obtained. No case of cross-contamination was observed amongsamples. After purification with the robot, DNA extracts can be automatically transferred in 96-wellsplates, which is an ideal format for subsequent RT-qPCR quantification and DNA amplification. Lesshands-on time and reduced risk of operational errors represent additional advantages of the robotic platform.
Resumo:
Needle fibre calcite is one of the most ubiquitous habits of calcite in vadose environments (caves deposits, soil pores, etc.). Its origin, either through inorganic, indirect or direct biological processes, has long been debated. In this study, investigations at 11 sites in Europe, Africa and Central America support arguments for its biogenic origin. The wide range of needle morphologies is the result of a gradual evolution of the simplest type, a rod. This rod is the elementary brick which, by aggregation and welding, builds more complex needles. The absence of cross-welded needles implies that they are welded in a mould, or under a longitudinal and unidirectional constraint, before being released inside the soil pores. The difference between the lengthening of the needles and the c axis can be explained by the existence of needles observed under a scanning electron microscope in organic sleeves, which can act as a mould during rod growth. Complex morphologies with epitaxial outgrowths on straight rods cannot have grown entirely inside organic microtubes; they must result from soil diagenesis after the release of straight rods in a soil-free medium. Whisker crystals are interpreted as the result of growth and coalescence of euhedral crystals on a rod. Rhomb chains are considered to be the consequence of successive epitaxial growth steps on a needle during variations in growth conditions. Isotopic signatures for needle fibre calcite vary from -16.63[per mille] to +1.10[per mille] and from -8.63[per mille] to -2.25[per mille] for Delta13C and Delta18O, respectively. The absence of high Delta18O values for needle fibre calcite precludes a purely physicochemical origin (evaporative) for this particular habit of calcite. As epitaxial growth cannot precipitate in the same conditions as initial needles, needle fibre calcite stable isotopic signatures should be used with caution as a proxy for palaeoenvironmental reconstructions. In addition, it is suggested that the term needle fibre calcite should be kept for the original biogenic form. The other habit should be referred to as epitaxial forms of needle fibre calcite.
Resumo:
Laparoscopic surgery has become a standard approach for many interventions, including oncologic surgery. Laparoscopic instruments have been developed to allow advanced surgical procedure. Imaging and computer assistance in virtual reality or robotic procedure will certainly improve access to this surgery.
Resumo:
Congenital hemiparesis is one of the most frequent pediatric motor disorders. Upper limb rehabilitation of the hemiparetic child has considerably evolved during the last decade by the use of focal chemical denervation (intramuscular botulinum toxin) and the introduction of novel rehabilitation techniques such as constraint induced movement therapy or robotic reeducation.
Resumo:
"MotionMaker (TM)" is a stationary programmable test and training system for the lower limbs developed at the 'Ecole Polytechnique Federale de Lausanne' with the 'Fondation Suisse pour les Cybertheses'.. The system is composed of two robotic orthoses comprising motors and sensors, and a control unit managing the trans-cutaneous electrical muscle stimulation with real-time regulation. The control of the Functional Electrical Stimulation (FES) induced muscle force necessary to mimic natural exercise is ensured by the control unit which receives a continuous input from the position and force sensors mounted on the robot. First results with control subjects showed the feasibility of creating movements by such closed-loop controlled FES induced muscle contractions. To make exercising with the MotionMaker (TM) safe for clinical trials with Spinal Cord Injured (SCI) volunteers, several original safety features have been introduced. The MotionMaker (TM) is able to identify and manage the occurrence of spasms. Fatigue can also be detected and overfatigue during exercise prevented.
Resumo:
The objective of the present study was longitudinal evaluation of the volumetric tumor response and functional results after Gamma Knife radiosurgery of vestibular schwannomas, performed according to the modern standards of treatment. From October 2003 to September 2007, 133 consecutive patients with vestibular schwannomas were treated according to the concept of robotic Gamma Knife microradiosurgery, which is based on precise irradiation of the lesion, sparing adjacent structures, and delivery of the high radiation energy to the target. Multiple small-sized isocenters located within the border of the neoplasm were applied. The mean marginal dose was 11.5 Gy (range, 11-12 Gy). In total, 126 cases with a minimum posttreatment follow-up of 2 years (range, 2-7 years; median, 4 years) were analyzed. Temporary enlargement was noted in 25 % of tumors at 6 months after radiosurgery. At 3 years of follow-up, tumor shrinkage, stabilization, and increase in volume were marked in 73 %, 23 %, and 4 % of cases, respectively. All progressing lesions spontaneously stabilized later on and did not require additional management. In 3 % of patients, transitory impairment of the facial nerve function was marked; however, neither its permanent dysfunction nor trigeminal neuropathy attributed to radiosurgery was noted. Impairment of hearing compared to its pretreatment level was revealed in 4 %, 12 %, 13 %, and 16 % of patients at 6 months, 1 year, 2 years, and 3 years after radiosurgery, respectively, and this trend was statistically significant (P = 0.0042). Overall, 77 % of patients with serviceable hearing before treatment preserved it 3 years thereafter. In conclusion, modern Gamma Knife radiosurgery provides effective and safe management of vestibular schwannomas. Nevertheless, possible temporary tumor enlargement, delay of its growth arrest, transient dysfunction of the cranial nerves, and gradual deterioration of hearing after irradiation should be always taken into consideration.
Resumo:
Engineered nanomaterials (ENMs) exhibit special physicochemical properties and thus are finding their way into an increasing number of industries, enabling products with improved properties. Their increased use brings a greater likelihood of exposure to the nanoparticles (NPs) that could be released during the life cycle of nano-abled products. The field of nanotoxicology has emerged as a consequence of the development of these novel materials, and it has gained ever more attention due to the urgent need to gather information on exposure to them and to understand the potential hazards they engender. However, current studies on nanotoxicity tend to focus on pristine ENMs, and they use these toxicity results to generalize risk assessments on human exposure to NPs. ENMs released into the environment can interact with their surroundings, change characteristics and exhibit toxicity effects distinct from those of pristine ENMs. Furthermore, NPs' large surface areas provide extra-large potential interfaces, thus promoting more significant interactions between NPs and other co-existing species. In such processes, other species can attach to a NP's surface and modify its surface functionality, in addition to the toxicity in normally exhibits. One particular occupational health scenario involves NPs and low-volatile organic compounds (LVOC), a common type of pollutant existing around many potential sources of NPs. LVOC can coat a NP's surface and then dominate its toxicity. One important mechanism in nanotoxicology is the creation of reactive oxygen species (ROS) on a NP's surface; LVOC can modify the production of these ROS. In summary, nanotoxicity research should not be limited to the toxicity of pristine NPs, nor use their toxicity to evaluate the health effects of exposure to environmental NPs. Instead, the interactions which NPs have with other environmental species should also be considered and researched. The potential health effects of exposure to NPs should be derived from these real world NPs with characteristics modified by the environment and their distinct toxicity. Failure to suitably address toxicity results could lead to an inappropriate treatment of nano- release, affect the environment and public health and put a blemish on the development of sustainable nanotechnologies as a whole. The main objective of this thesis is to demonstrate a process for coating NP surfaces with LVOC using a well-controlled laboratory design and, with regard to these NPs' capacity to generate ROS, explore the consequences of changing particle toxicity. The dynamic coating system developed yielded stable and replicable coating performance, simulating an important realistic scenario. Clear changes in the size distribution of airborne NPs were observed using a scanning mobility particle sizer, were confirmed using both liquid nanotracking analyses and transmission electron microscopy (TEM) imaging, and were verified thanks to the LVOC coating. Coating thicknesses corresponded to the amount of coating material used and were controlled using the parameters of the LVOC generator. The capacity of pristine silver NPs (Ag NPs) to generate ROS was reduced when they were given a passive coating of inert paraffin: this coating blocked the reactive zones on the particle surfaces. In contrast, a coating of active reduced-anthraquinone contributed to redox reactions and generated ROS itself, despite the fact that ROS generation due to oxidation by Ag NPs themselves was quenched. Further objectives of this thesis included development of ROS methodology and the analysis of ROS case studies. Since the capacity of NPs to create ROS is an important effect in nanotoxicity, we attempted to refine and standardize the use of 2'7-dichlorodihydrofluorescin (DCFH) as a chemical tailored for the characterization of NPs' capacity for ROS generation. Previous studies had reported a wide variety of results, which were due to a number of insufficiently well controlled factors. We therefore cross-compared chemicals and concentrations, explored ways of dispersing NP samples in liquid solutions, identified sources of contradictions in the literature and investigated ways of reducing artificial results. The most robust results were obtained by sonicating an optimal sample of NPs in a DCFH-HRP solution made of 5,M DCFH and 0.5 unit/ml horseradish peroxidase (HRP). Our findings explained how the major reasons for previously conflicting results were the different experimental approaches used and the potential artifacts appearing when using high sample concentrations. Applying our advanced DCFH protocol with other physicochemical characterizations and biological analyses, we conducted several case studies, characterizing aerosols and NP samples. Exposure to aged brake wear dust engenders a risk of potential deleterious health effects in occupational scenarios. We performed microscopy and elemental analyses, as well as ROS measurements, with acellular and cellular DCFH assays. TEM images revealed samples to be heterogeneous mixtures with few particles in the nano-scale. Metallic and non-metallic elements were identified, primarily iron, carbon and oxygen. Moderate amounts of ROS were detected in the cell-free fluorescent tests; however, exposed cells were not dramatically activated. In addition to their highly aged state due to oxidation, the reason aged brake wear samples caused less oxidative stress than fresh brake wear samples may be because of their larger size and thus smaller relative reactive surface area. Other case studies involving welding fumes and differently charged NPs confirmed the performance of our DCFH assay and found ROS generation linked to varying characteristics, especially the surface functionality of the samples. Les nanomatériaux manufacturés (ENM) présentent des propriétés physico-chimiques particulières et ont donc trouvés des applications dans un nombre croissant de secteurs, permettant de réaliser des produits ayant des propriétés améliorées. Leur utilisation accrue engendre un plus grand risque pour les êtres humains d'être exposés à des nanoparticules (NP) qui sont libérées au long de leur cycle de vie. En conséquence, la nanotoxicologie a émergé et gagné de plus en plus d'attention dû à la nécessité de recueillir les renseignements nécessaires sur l'exposition et les risques associés à ces nouveaux matériaux. Cependant, les études actuelles sur la nanotoxicité ont tendance à se concentrer sur les ENM et utiliser ces résultats toxicologiques pour généraliser l'évaluation des risques sur l'exposition humaine aux NP. Les ENM libérés dans l'environnement peuvent interagir avec l'environnement, changeant leurs caractéristiques, et montrer des effets de toxicité distincts par rapport aux ENM originaux. Par ailleurs, la grande surface des NP fournit une grande interface avec l'extérieur, favorisant les interactions entre les NP et les autres espèces présentes. Dans ce processus, d'autres espèces peuvent s'attacher à la surface des NP et modifier leur fonctionnalité de surface ainsi que leur toxicité. Un scénario d'exposition professionnel particulier implique à la fois des NP et des composés organiques peu volatils (LVOC), un type commun de polluant associé à de nombreuses sources de NP. Les LVOC peuvent se déposer sur la surface des NP et donc dominer la toxicité globale de la particule. Un mécanisme important en nanotoxicologie est la création d'espèces réactives d'oxygène (ROS) sur la surface des particules, et les LVOC peuvent modifier cette production de ROS. En résumé, la recherche en nanotoxicité ne devrait pas être limitée à la toxicité des ENM originaux, ni utiliser leur toxicité pour évaluer les effets sur la santé de l'exposition aux NP de l'environnement; mais les interactions que les NP ont avec d'autres espèces environnementales doivent être envisagées et étudiées. Les effets possibles sur la santé de l'exposition aux NP devraient être dérivés de ces NP aux caractéristiques modifiées et à la toxicité distincte. L'utilisation de résultats de toxicité inappropriés peut conduire à une mauvaise prise en charge de l'exposition aux NP, de détériorer l'environnement et la santé publique et d'entraver le développement durable des industries de la nanotechnologie dans leur ensemble. L'objectif principal de cette thèse est de démontrer le processus de déposition des LVOC sur la surface des NP en utilisant un environnement de laboratoire bien contrôlé et d'explorer les conséquences du changement de toxicité des particules sur leur capacité à générer des ROS. Le système de déposition dynamique développé a abouti à des performances de revêtement stables et reproductibles, en simulant des scénarios réalistes importants. Des changements clairs dans la distribution de taille des NP en suspension ont été observés par spectrométrie de mobilité électrique des particules, confirmé à la fois par la méthode dite liquid nanotracking analysis et par microscopie électronique à transmission (MET), et a été vérifié comme provenant du revêtement par LVOC. La correspondance entre l'épaisseur de revêtement et la quantité de matériau de revêtement disponible a été démontré et a pu être contrôlé par les paramètres du générateur de LVOC. La génération de ROS dû aux NP d'argent (Ag NP) a été diminuée par un revêtement passif de paraffine inerte bloquant les zones réactives à la surface des particules. Au contraire, le revêtement actif d'anthraquinone réduit a contribué aux réactions redox et a généré des ROS, même lorsque la production de ROS par oxydation des Ag NP avec l'oxygène a été désactivé. Les objectifs associés comprennent le développement de la méthodologie et des études de cas spécifique aux ROS. Etant donné que la capacité des NP à générer des ROS contribue grandement à la nanotoxicité, nous avons tenté de définir un standard pour l'utilisation de 27- dichlorodihydrofluorescine (DCFH) adapté pour caractériser la génération de ROS par les NP. Des etudes antérieures ont rapporté une grande variété de résultats différents, ce qui était dû à un contrôle insuffisant des plusieurs facteurs. Nous avons donc comparé les produits chimiques et les concentrations utilisés, exploré les moyens de dispersion des échantillons HP en solution liquide, investigué les sources de conflits identifiées dans les littératures et étudié les moyens de réduire les résultats artificiels. De très bon résultats ont été obtenus par sonication d'une quantité optimale d'échantillons de NP en solution dans du DCFH-HRP, fait de 5 nM de DCFH et de 0,5 unité/ml de Peroxydase de raifort (HRP). Notre étude a démontré que les principales raisons causant les conflits entre les études précédemment conduites dans la littérature étaient dues aux différentes approches expérimentales et à des artefacts potentiels dus à des concentrations élevées de NP dans les échantillons. Utilisant notre protocole DCFH avancé avec d'autres caractérisations physico-chimiques et analyses biologiques, nous avons mené plusieurs études de cas, caractérisant les échantillons d'aérosols et les NP. La vielle poussière de frein en particulier présente un risque élevé d'exposition dans les scénarios professionnels, avec des effets potentiels néfastes sur la santé. Nous avons effectué des analyses d'éléments et de microscopie ainsi que la mesure de ROS avec DCFH cellulaire et acellulaire. Les résultats de MET ont révélé que les échantillons se présentent sous la forme de mélanges de particules hétérogènes, desquels une faible proportion se trouve dans l'échelle nano. Des éléments métalliques et non métalliques ont été identifiés, principalement du fer, du carbone et de l'oxygène. Une quantité modérée de ROS a été détectée dans le test fluorescent acellulaire; cependant les cellules exposées n'ont pas été très fortement activées. La raison pour laquelle les échantillons de vielle poussière de frein causent un stress oxydatif inférieur par rapport à la poussière de frein nouvelle peut-être à cause de leur plus grande taille engendrant une surface réactive proportionnellement plus petite, ainsi que leur état d'oxydation avancé diminuant la réactivité. D'autres études de cas sur les fumées de soudage et sur des NP différemment chargées ont confirmé la performance de notre test DCFH et ont trouvé que la génération de ROS est liée à certaines caractéristiques, notamment la fonctionnalité de surface des échantillons.
Resumo:
OPINION STATEMENT: Therapeutic options for early stage oropharyngeal squamous cell carcinoma (OPSCC) include both surgery and radiotherapy as single treatment modality. Retrospective data reporting on locoregional control and survival rates in early stage OPSCC have shown equivalent efficacy, although no prospective randomized trials are available to confirm these results. Given the assumed comparable oncologic results in both groups, complication rates and functional outcomes associated with each modality play a major role when making treatment decisions. Radiotherapy is used preferentially in many centers because few trials have reported higher complication rates in surgical patients. However, these adverse effects were mainly due to traditional invasive open surgical approaches used for access to the oropharynx. In order to decrease the morbidity of these techniques, transoral surgical (TOS) approaches have been developed progressively. They include transoral laser microsurgery (TLM), transoral robotic surgery (TORS), and conventional transoral techniques. Meta-analysis comparing these new approaches with radiotherapy showed equivalent efficacy in terms of oncologic results. Furthermore, studies reporting on functional outcomes in patients undergoing TOS for OPSCC did not show major long-term functional impairment following treatment. Given the abovementioned statements, it is our practice to treat early stage OPSCC as follows: whenever a single modality treatment seems feasible (T1-2 and N0-1), we advocate TOS resection of the primary tumor associated with selective neck dissection, as indicated. In our opinion, the advantage of this approach relies on the possibility to stratify the risk of disease progression based on the pathological features of the tumor. Depending on the results, adjuvant radiation treatment or chemoradiotherapy can be chosen for high-risk patients. For tumors without adverse features, no adjuvant treatment is given. This approach also allows prevention of potential radiation-induced late complications while keeping radiotherapy as an option for any second primary lesions whenever needed. Definitive radiotherapy is generally reserved for selected patients with specific anatomical location associated with poor functional outcome following surgery, such as tumor of the soft palate, or for patients with severe comorbidities that do not allow surgical treatment.