446 resultados para patient-ventilator synchrony
Resumo:
INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) [1] is a new spontaneousassisted ventilatory mode which uses the diaphragmatic electrical activity (Eadi) to pilot the ventilator. Eadi is used to initiate the ventilator's pressurization and cycling off. Delivered inspiratory assistance is proportional to Eadi. NAVA can improve patient-ventilator synchrony [2] compared to pressure support (PS), but little is known about its effect on minute ventilation and oxygenation. OBJECTIVES. To compare the effects of NAVA and PS on minute ventilation and oxygenation and to analyze potential determinant factors for oxygenation. METHODS. Comparison between two 20-min periods under NAVA and PS. NAVA gain (proportionality factor between Eadi and delivered pressure) set as to obtain the same peak pressure as in PS. FIO2 and positive end-expiratory pressure (PEEP) were the same in NAVA and PS. Blood gas analyses were performed at the end of both recording periods. Statistical analysis: groups were compared with paired t tests or non parametric Wilcoxon signed-rank tests. p\0.05 was considered significant. RESULTS. [Mean ± SD]: 22 patients (age 66 ± 12 year, 7 M/15F, BMI 23.4 ± 3.1 kg/m2), 8 patients with COPD. Initial settings: PS 13 ± 3 cmH2O, PEEP 7 ± 2 cmH2O, NAVA gain 2.2 ± 1.8. Minute ventilation and PaCO2 were the same with both modes (p = 0.296 and 0.848, respectively). Tidal volume was lower with NAVA (427 ± 102 vs. 477 ± 102 ml, p\0.001). In contrast respiratory rate was higher with NAVA (25.6 ± 9.5 vs. 22.3 ± 8.9 cycles/min). Arterial oxygenation was improved with NAVA (PaO2 85.1 ± 28.9 vs. 75.8 ± 11.9 mmHg, p = 0.017, PaO2/FIO2 210 ± 53 vs. 195 ± 58 mmHg, p = 0.019). Neural inspiratory time (Tin) was comparable between NAVA and PS (p = 0.566). Among potential determinant factors for oxygenation, mean airway pressure (Pmean) was lower with NAVA (10.6 ± 2.6 vs. 11.1 ± 2.4 cmH2O, p = 0.006), as was the pressure time product (PTP) (6.8 ± 3.0 vs. 9.2 ± 3.5 cmH2O 9 s, p = 0.004). There were less asynchrony events with NAVA (2.3 ± 2.0 vs. 4.4 ± 3.8, p = 0.009).Tidal volume variability was higher with NAVA (variation coefficient: 30 ± 19.5 vs. 13.5 ± 8.6, p\0.001). Inspiratory time in excess (Tiex) was lower with NAVA (56 ± 23 vs. 202 ± 200 ms, p = 0.001). CONCLUSION. Despite lower Pmean and PTP in NAVA, arterial oxygenation was improved compared to PS. As asynchronies may be associated with an increased work of breathing and a higher oxygen consumption, their decrease in number with NAVA could be an explanation for oxygenation improvement. Another explanation could be the increase in VT variability. Further studies should now be performed to confirm the potential of NAVA in improving arterial oxygenation and explore the underlying mechanisms.
Resumo:
Neurally adjusted ventilatory assist or NAVA is a new assisted ventilatory mode which, in comparison with pressure support, leads to improved patient-ventilator synchrony and a more variable ventilatory pattern. It also improves arterial oxygenation. With NAVA, the electrical activity of the diaphragm is recorded through a nasogastric tube equipped with electrodes. This electrical activity is then used to pilot the ventilator. With NAVA, the patient's respiratory pattern controls the ventilator's timing of triggering and cycling as well as the magnitude of pressurization, which is proportional to inspiratory demand. The effect of NAVA on patient outcome remains to be determined through well-designed prospective studies.
Resumo:
BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.
Resumo:
To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.
Resumo:
ABSTRACT: BACKGROUND: The incidence of ventilator-associated pneumonia (VAP) within the first 48 hours of intensive care unit (ICU) stay has been poorly investigated. The objective was to estimate early-onset VAP occurrence in ICUs within 48 hours after admission. METHODS: We analyzed data from prospective surveillance between 01/01/2001 and 31/12/2009 in 11 ICUs of Lyon hospitals (France). The inclusion criteria were: first ICU admission, not hospitalized before admission, invasive mechanical ventilation during first ICU day, free of antibiotics at admission, and ICU stay >=48 hours. VAP was defined according to a national protocol. Its incidence was the number of events per 1,000 invasive mechanical ventilation-days. The Poisson regression model was fitted from day 2 (D2) to D8 to incident VAP to estimate the expected VAP incidence from D0 to D1 of ICU stay. RESULTS: Totally, 367 (10.8%) of 3,387 patients in 45,760 patient-days developed VAP within the first 9 days. The predicted cumulative VAP incidence at D0 and D1 was 5.3 (2.6-9.8) and 8.3 (6.1-11.1), respectively. The predicted cumulative VAP incidence was 23.0 (20.8-25.3) at D8. The proportion of missed VAP within 48 hours from admission was 11% (9%-17%). CONCLUSIONS: Our study indicates underestimation of early-onset VAP incidence in ICUs, if only VAP occurring [greater than or equal to]48 hours is considered to be hospital-acquired. Clinicians should be encouraged to develop a strategy for early detection after ICU admission.
Resumo:
Purpose: Recent reports have suggested that intraabdominal postoperative infection is associated with higher rates of overall and local recurrence and cancer-specific mortality. However, the mechanisms responsible for this association are unknown. We hypothesized that the greater inflammatory response in patients with postoperative intraabdominal infection is associated to an increase in local and systemic angiogenesis. Methods: We designed a prospective cohorts study with matched controls. Patients with postoperative intra-abdominal infection (abscess and/or anastomotic leakage) (group 1; n=17) after elective colorectal cancer resection operated on for cure were compared to patients with an uncomplicated postoperative course (group 2; n=17). IL-6 and VEGF levels were determined by ELISA in serum and peritoneal fluid at baseline, 48 hours and postoperative day 4 or at the time the peritoneal infection occurred. Results: No differences were observed in age, gender, preoperative CEA, tumor stage and location and type of procedure performed. Although there were no differences in serum IL-6 levels at 48 hours, this pro-inflammatory cytokine was higher in group 1 on postoperative day 4 (group 1: 21533 + 27900 vs. group 2: 1130 + 3563 pg/ml; p < 0.001). Serum VEGF levels were higher in group 1 on postoperative day 4 (group 1: 1212 + 1025 vs. group 2: 408 + 407 pg/ml; p < 0.01). Peritoneal fluid VEGF levels were also higher in group 1 at 48 hours (group 1: 4857 + 4384 vs. group 2: 630 + 461 pg/ml; p < 0.001) and postoperative day 4 (group 1: 32807 + 98486 vs. group 2: 1002 + 1229 pg/ml; p < 0.001). A positive correlation between serum IL-6 and VEGF serum levels was observed on postoperative day 4 (r=0.7; p<0.01). Conclusions: These results suggest that not only the inflammatory response but also the angiogenic pathways are stimulated in patients with intra-abdominal infection after surgery for colorectal cancer. The implications of this finding on long-term follow-up need to be evaluated.
Resumo:
Williams-Beuren syndrome (WBS; OMIM no. 194050) is a multisystemic neurodevelopmental disorder caused by a hemizygous deletion of 1.55 Mb on chromosome 7q11.23 spanning 28 genes. Haploinsufficiency of the ELN gene was shown to be responsible for supravalvular aortic stenosis and generalized arteriopathy, whereas LIMK1, CLIP2, GTF2IRD1 and GTF2I genes were suggested to be linked to the specific cognitive profile and craniofacial features. These insights for genotype-phenotype correlations came from the molecular and clinical analysis of patients with atypical deletions and mice models. Here we report a patient showing mild WBS physical phenotype and normal IQ, who carries a shorter 1 Mb atypical deletion. This rearrangement does not include the GTF2IRD1 and GTF2I genes and only partially the BAZ1B gene. Our results are consistent with the hypothesis that hemizygosity of the GTF2IRD1 and GTF2I genes might be involved in the facial dysmorphisms and in the specific motor and cognitive deficits observed in WBS patients.
Resumo:
OBJECTIVE: : To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN: : In vitro, laboratory study. SETTING: : Research laboratory of a university hospital. INTERVENTIONS: : Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested in three nebulization modes in a nonhumidified bench model mimicking the ventilatory pattern of a 10-kg infant. The amounts of albuterol deposited on the inspiratory filters (inhaled drug) at the end of the endotracheal tube, on the expiratory filters, and remaining in the nebulizers or in the ventilator circuit were determined. Particle size distribution of the nebulizers was also measured. MEASUREMENTS AND MAIN RESULTS: : The inhaled drug was 2.8% ± 0.5% for the jet nebulizer, 10.5% ± 2.3% for the ultrasonic nebulizer, and 5.4% ± 2.7% for the vibrating-mesh nebulizer in intermittent nebulization during the inspiratory phase (p < 0.01). The most efficient nebulizer was the vibrating-mesh nebulizer in continuous nebulization (13.3% ± 4.6%, p < 0.01). Depending on the nebulizers, a variable but important part of albuterol was observed as remaining in the nebulizers (jet and ultrasonic nebulizers), or being expired or lost in the ventilator circuit (all nebulizers). Only small particles (range 2.39-2.70 µm) reached the end of the endotracheal tube. CONCLUSIONS: : Important differences between nebulizer types and nebulization modes were seen for albuterol deposition at the end of the endotracheal tube in an in vitro pediatric ventilator-lung model. New aerosol devices, such as ultrasonic and vibrating-mesh nebulizers, were more efficient than the jet nebulizer.
Resumo:
Introduction/objectives: Multipatient use of a single-patient CBSD occurred inan outpatient clinic during 4 to 16 months before itsnotification. We looked for transmission of blood-bornepathogens among exposed patients.Methods: Exposed patients underwent serology testing for HBV,HCV and HIV. Patients with isolated anti-HBc receivedone dose of hepatitis B vaccine to look for a memoryimmune response. Possible transmissions were investigatedby mapping visits and sequencing of the viral genomeif needed.Results: Of 280 exposed patients, 9 had died without suspicionof blood-borne infection, 3 could not be tested, and 5declined investigations. Among the 263 (93%) testedpatients, 218 (83%) had negative results. We confirmeda known history of HCV infection in 6 patients (1 coinfectedby HIV), and also identified resolved HBVinfection in 37 patients, of whom 18 were alreadyknown. 2 patients were found to have a previouslyunknown HCV infection. According to the time elapsedfrom the closest previous visit of a HCV-infected potentialsource patient, we could rule out nosocomial transmissionin one case (14 weeks) but not in the other (1day). In the latter, however, transmission was deemedvery unlikely by 2 reference centers based on thesequences of the E1 and HVR1 regions of the virus.Conclusion: We did not identify any transmission of blood-bornepathogens in 263 patients exposed to a single-patientCBSD, despite the presence of potential source cases.Change of needle and disinfection of the device betweenpatients may have contributed to this outcome.Although we cannot exclude transmission of HBV, previousacquisition in endemic countries is a more likelyexplanation in this multi-national population.
Resumo:
BACKGROUND: Type 1 pseudohypoaldosteronism (PHA1) is a salt-wasting syndrome caused by mineralocorticoid resistance. Autosomal recessive and dominant hereditary forms are caused by Epithelial Na Channel and Mineralocorticoid Receptor mutation respectively, while secondary PHA1 is usually associated with urological problems. METHODS: Ten patients were studied in four French pediatric units in order to characterize PHA1 spectrum in infants. Patients were selected by chart review. Genetic, clinical and biochemistry data were collected and analyzed. RESULTS: Autosomal recessive PHA1 (n = 3) was diagnosed at 6 and 7 days of life in three patients presenting with severe hyperkalaemia and weight loss. After 8 months, 3 and 5 years on follow-up, neurological development and longitudinal growth was normal with high sodium supplementation. Autosomal dominant PHA1 (n = 4) was revealed at 15, 19, 22 and 30 days of life because of failure to thrive. At 8 months, 3 and 21 years of age, longitudinal growth was normal in three patients who were given salt supplementation; no significant catch-up growth was obtained in the last patient at 20 months of age. Secondary PHA1 (n = 3) was diagnosed at 11, 26 days and 5 months of life concomitantly with acute pyelonephritis in three children with either renal hypoplasia, urinary duplication or bilateral megaureter. The outcome was favourable and salt supplementation was discontinued after 3, 11 and 13 months. CONCLUSIONS: PHA1 should be suspected in case of severe hyperkalemia and weight loss in infants and need careful management. Pathogenesis of secondary PHA1 is still challenging and further studies are mandatory to highlight the link between infection, developing urinary tract and pseudohypoaldosteronism.
Resumo:
BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.
Resumo:
Résumé. Mon travail s'articule en deux parties, chacune formée de deux chapitres, consacrées successivement au faire et à l'être, pour passer sans cesse du medicus faber au medicus sapiens, deux identités en interaction constante, pour une médecine des confins de la vie qui se veut responsable. I. La question du faire pour la médecine des confins de la vie. -Le premier chapitre sera dédié à la démesure, l'hybris de notre médecine moderne. L'action de Prométhée, par le feu donné, me permettra d'acquérir le savoir, la science nécessaire à un artisanat d'honnête homme. Il s'agit de faire juste car, sans cela, la médecine est une imposture. Inverser les priorités, privilégier la culture de l'être au détriment des compétences du faire, risque bien de déboucher sur la tromperie d'un pseudo être qui recouvre une incompétence coupable. Mais la foi dans le faire seul, dans une action détachée d'une réflexion critique prenant en compte l'être, mène à l'hybris, à la démesure de l'homme qui se croit et se proclame Dieu. Et nous voici ainsi menés face à Némésis, la vengeance qui punit l'hybris. -Dans le deuxième chapitre, cette action, y compris dans sa tendance à la démesure, l'hybris, se verra plongée dans l'utilitarisme qui imprègne la pensée occidentale moderne et oriente tout notre contexte moral objectif, ce bruissement ambiant d'idées qui baigne et infléchit notre réflexion quotidienne. Nous verrons, dans le chapitre dédié à cette grammaire éthique, que lorsqu'il s'agit de donner au plus grand nombre le plus de bonheur possible, les patients des confins de la vie se trouvent toujours du côté des perdants, des sacrifiés du bonheur. Cette part de mon travail me permettra de poser les principes de l'utilitarisme et d'en critiquer tant les fondements que les applications dans le cadre de la médecine des confins de la vie. Puis la politique, qui gère les affaires de la Cité, entrera en jeu et l'étai de pénurie, de différence entre les besoins réels ou ressentis et les ressources, donnera un cadre contraignant à cette réflexion communautaire. J'examinerai de manière critique diverses facettes des solutions proposées par la pensée utilitariste puis chercherai avec John Rawls et Antigone la manière la plus sage d'atteindre, selon le mot de Ricoeur, «une vie bonne avec et pour les autres dans une société juste. » II : La question de l'être pour la médecine des confins de la vie -Dans le troisième chapitre, consacré à la dignité, je tenterai de cerner cette idée pour le patient des confins de la vie, et j'aborderai cette notion par deux chemins complémentaires et convergents : le temps congelé et le trou de dignité. Je m'interrogerai tout d'abord, réfléchissant quelque instant à propos de l'embryon congelé, sur le temps figé de celui qui, dans la démence, n'a plus ni hier ni demain. Suspendu dans un présent qui s'éternise, il échappe à la mortalité et à l'humaine condition jusqu'à ce que la mort le surprenne, de l'extérieur de lui-même. Pour réinscrire le patient dans sa temporalité, pour lui rendre sa mortalité propre et reconstruire ainsi son statut d'être humain, sa dignité, il nous faudra faire appel à ce que je nomme la contagion temporelle. Elle est le fait de l'entourage du patient, de celles et ceux qui forment son contexte, la famille et les proches comme les professionnels. Puis j'examinerai plusieurs significations du mot dignité, en particulier la dignité dite ontologique, liée à l'être, et celle que l'on peut dire conditionnelle, relative à divers attributs, comme le paraître ou la raison, dont l'homme peut être ou non pourvu. Entre ces deux dignités se creuse le trou de dignité toujours menaçant car il comporte l'idée d'une brisure, d'une frontière entre les hommes, qui distingue et sépare entre les humains, leur attribuant une valeur. Cette valeur réifie l'homme et menace ainsi la dignité de chacun. Le patient des confins de la vie, qu'il soit égaré dans l'intemporalité ou dans le trou de dignité, doit être impérativement maintenu dans la communauté comme dans la continuité de sa propre vie jusqu'à ce que sa propre mort marque l'achèvement de son propre chemin. Ce devoir, pour celles et ceux qui cheminent avec lui, de près ou de loin, échappe au particulier et au circonstanciel pour acquérir un statut normatif, catégorique et universel. -Dans le quatrième chapitre, deux philosophes nous permettront d'aspirer le trou de dignité jusqu'à le rendre virtuel. Avec Martin Buber, nous examinerons le rapport Je-Cela et la relation Je-Tu dans le contexte particulier des interactions qui unissent le patient des confins de sa vie et son médecin. Puis il nous faudra bien réaliser que cette relation se trouve mise en danger dans les Je-Tu brisés par la démence ou l'état confusionnel. Comment, dans les confins de la vie, maintenir la relation lorsque Tu n'en veut ou n'en peut plus ? Emmanuel Levinas, et le visage de l'autre qui m'oblige et m'en rend responsable absolument, viendra à la rescousse, nous permettant ainsi d'éviter au patient des confins la perte de son ultime dignité dans la Shoah intime qui le menace dans ce temps de la vie. Cette thèse va donc parcourir un chemin qui partant du faire ne pourra que me mener à un questionnement sur l'être. Il s'agit d'un travail d'homme actif qui a pour but, dans ma trajectoire de vie, de donner un sens à mon artisanat du soin. Nous verrons donc que le faire, l'acte, ne pourra que se montrer complémentaire de l'être, de la dignité et que ces deux approches tisseront et entremêleront leurs brins dans ce tapis chatoyant de la vie, de celle, de celui, qu'r en atteint les confins, comme de la mienne.
Resumo:
Purpose: To report a novel maculopathy in a patient with SCA1. To describe autofluorescence findings in family with SCA7 and associated cone-rod retinal dysfunction.Methods: 4 affected patients from two families were assessed to investigate a progressive loss of visual acuity (VA). Examinations included fundus photography, autofluorescence (AF) fundus fluorescein angiogragraphy (FFA) and optical coherence tomography. Electroretinogram (full-field) was performed in 2 affected patients. All patients had color vision testing using Ishihara pseudoisochromatic plates. Molecular analysis was performed in family 2.Results: The patient with known diagnosis of SCA1 had a visual acuity of 20/200 bilaterally and dyschromatopsia. He had saccadic pursuit. Fundus examination showed mild retinal pigment epithelium (RPE) changes at the macula. OCT showed bilateral macular serous detachment, which was not obvious at the FFA and explained his VA. AF imaging showed a central hyperfluorescence. The 45 year old proband from family 2 had a visual acuity of 200/20 and dyschromatopsia. ERG testing showed cone type dysfunction of photoreceptors. Her daughter affected at a younger age had the same ERGs findings. Fundus examination showed mild RPE changes in proband, normal findings in her daughter. AF imaging of both patients showed a ring of high density AF around the fovea. The ring was also obvious on near infrared AF. Later onset of gait imbalance led to the diagnosis of SCA7Conclusions: Within the group of spinocerebellar ataxias, only the type 7 is associated with retinal dysfunction. We present the first report of maculopathy associated with SCA1 causing severe vision loss. The ring of high density AF in SCA7 confirmed an early retinal photoreceptor dysfunction in patient with normal fundus.