23 resultados para machine and metal product industry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Beryllium (Be) is increasingly used in various industrial applications. Occupational exposure to Be may lead to chronic beryllium disease (CBD), a pulmonary granulomatous disorder closely similar to sarcoidosis, which develop in 1 to 15% of exposed workers. Although Switzerland is one of the major Be importers worldwide, little information is available about occurrence of exposure and the number of workers exposed in this country. Objectives: 1) evaluate the number of workers potentially exposed to Be in Switzerland; 2) construct a screening tool to allow potential Be exposure detection in a clinical setting. Methods: After identification of industrial sectors involving beryllium exposure based on expert reports and scientific literature, an estimation of the number of workers employed in these relevant industries was made using data from the Swiss federal population census and registries of economic activities. A second analysis was performed to estimate the fraction of workers really exposed to Be in each industrial sector. This adjustment was made according to the results of a French survey (INRS, Institut National de Recherche et de Sécurité) conducted by questionnaire addressed to 4500 companies in relevant industries on their use of beryllium and other issues such as percentage of employees really exposed. These realistic data were used to develop a self-administrated screening questionnaire allowed to identify patients with possible Be exposure. Results: In Switzerland, the number of workers employed in industries using Be was nearly 150 000. The estimated number of workers exposed to beryllium in these industries ranged from 2000 to 4000. Relevant sectors were: microengineering, precision turning, watchmaking and metal waste treatment and recycling. The validation of the self-administrated questionnaire containing a list of jobs and leisure activities associated with potential Be exposure is in progress within the framework of a national study. Conclusions: The number of workers potentially exposed to Be in Switzerland is rather high compared to estimations for other industrialized countries and might constitute an underestimated occupational health problem. Undetected Be exposure in patients with sarcoidosis may occur and result in misdiagnosis. Once validated, the self-administrated questionnaire could be used by clinicians to screen for Be exposure in patients with granulomatous lung disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. MATERIALS AND METHODS: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. RESULTS: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10cm from the PTV border the Tomotherapy up to 35cm. CONCLUSIONS: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35cm from the PTV border (for a 390 cm(3) large PTV).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phosphate is a crucial and often limiting nutrient for plant growth. To obtain inorganic phosphate (P(i) ), which is very insoluble, and is heterogeneously distributed in the soil, plants have evolved a complex network of morphological and biochemical processes. These processes are controlled by a regulatory system triggered by P(i) concentration, not only present in the medium (external P(i) ), but also inside plant cells (internal P(i) ). A 'split-root' assay was performed to mimic a heterogeneous environment, after which a transcriptomic analysis identified groups of genes either locally or systemically regulated by P(i) starvation at the transcriptional level. These groups revealed coordinated regulations for various functions associated with P(i) starvation (including P(i) uptake, P(i) recovery, lipid metabolism, and metal uptake), and distinct roles for members in gene families. Genetic tools and physiological analyses revealed that genes that are locally regulated appear to be modulated mostly by root development independently of the internal P(i) content. By contrast, internal P(i) was essential to promote the activation of systemic regulation. Reducing the flow of P(i) had no effect on the systemic response, suggesting that a secondary signal, independent of P(i) , could be involved in the response. Furthermore, our results display a direct role for the transcription factor PHR1, as genes systemically controlled by low P(i) have promoters enriched with P1BS motif (PHR1-binding sequences). These data detail various regulatory systems regarding P(i) starvation responses (systemic versus local, and internal versus external P(i) ), and provide tools to analyze and classify the effects of P(i) starvation on plant physiology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Postmortem computed tomography angiography (PMCTA) was introduced into forensic investigations a few years ago. It provides reliable images that can be consulted at any time. Conventional autopsy remains the reference standard for defining the cause of death, but provides only limited possibility of a second examination. This study compares these two procedures and discusses findings that can be detected exclusively using each method. MATERIALS AND METHODS: This retrospective study compared radiological reports from PMCTA to reports from conventional autopsy for 50 forensic autopsy cases. Reported findings from autopsy and PMCTA were extracted and compared to each other. PMCTA was performed using a modified heart-lung machine and the oily contrast agent Angiofil® (Fumedica AG, Muri, Switzerland). RESULTS: PMCTA and conventional autopsy would have drawn similar conclusions regarding causes of death. Nearly 60 % of all findings were visualized with both techniques. PMCTA demonstrates a higher sensitivity for identifying skeletal and vascular lesions. However, vascular occlusions due to postmortem blood clots could be falsely assumed to be vascular lesions. In contrast, conventional autopsy does not detect all bone fractures or the exact source of bleeding. Conventional autopsy provides important information about organ morphology and remains the only way to diagnose a vital vascular occlusion with certitude. CONCLUSION: Overall, PMCTA and conventional autopsy provide comparable findings. However, each technique presents advantages and disadvantages for detecting specific findings. To correctly interpret findings and clearly define the indications for PMCTA, these differences must be understood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been used successfully in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits; to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Two important risk factors for abnormal neurodevelopment are preterm birth and neonatal hypoxic ischemic encephalopathy. The new revisions of Griffiths Mental Development Scale (Griffiths-II, [1996]) and the Bayley Scales of Infant Development (BSID-II, [1993]) are two of the most frequently used developmental diagnostics tests. The Griffiths-II is divided into five subscales and a global development quotient (QD), and the BSID-II is divided into two scales, the Mental scale (MDI) and the Psychomotor scale (PDI). The main objective of this research was to establish the extent to which developmental diagnoses obtained using the new revisions of these two tests are comparable for a given child. MATERIAL AND METHODS: Retrospective study of 18-months-old high-risk children examined with both tests in the follow-up Unit of the Clinic of Neonatology of our tertiary care university Hospital between 2011 and 2012. To determine the concurrent validity of the two tests paired t-tests and Pearson product-moment correlation coefficients were computed. Using the BSID-II as a gold standard, the performance of the Griffiths-II was analyzed with receiver operating curves. RESULTS: 61 patients (80.3% preterm, 14.7% neonatal asphyxia) were examined. For the BSID-II the MDI mean was 96.21 (range 67-133) and the PDI mean was 87.72 (range 49-114). For the Griffiths-II, the QD mean was 96.95 (range 60-124), the locomotors subscale mean was 92.57 (range 49-119). The score of the Griffiths locomotors subscale was significantly higher than the PDI (p<0.001). Between the Griffiths-II QD and the BSID-II MDI no significant difference was found, and the area under the curve was 0.93, showing good validity. All correlations were high and significant with a Pearson product-moment correlation coefficient >0.8. CONCLUSIONS: The meaning of the results for a given child was the same for the two tests. Two scores were interchangeable, the Griffiths-II QD and the BSID-II MDI.