313 resultados para intraocular prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Purpose: To describe viral retinitis following intravitreal and periocular corticosteroid administration. Methods: Retrospective case series and comprehensive literature review. Results: We analyzed 5 unreported and 25 previously published cases of viral retinitis following local corticosteroid administration. Causes of retinitis included 23 CMV (76.7%), 5 HSV (16.7%), and 1 each VZV and unspecified (3.3%). Two of 22 tested patients (9.1%) were HIV positive. Twenty-one of 30 (70.0%) cases followed one or more intravitreal injections of triamcinolone acetonide (TA), 4 (13.3%) after one or more posterior sub-Tenon injections of TA, 3 (10.0%) after placement of a 0.59-mg fluocinolone acetonide implant (Retisert), and 1 (3.3%) each after an anterior subconjunctival injection of TA (together with IVTA), an anterior chamber injection, and an anterior sub-Tenon injection. Mean time from most recent corticosteroid administration to development of retinitis was 4.2 months (median 3.8; range 0.25-13.0). Twelve patients (40.0%) had type II diabetes mellitus. Treatments used included systemic antiviral agents (26/30, 86.7%), intravitreal antiviral injections (20/30, 66.7%), and ganciclovir intravitreal implants (4/30, 13.3%). Conclusions: Viral retinitis may develop or reactivate following intraocular or periocular corticosteroid administration. Average time to development of retinitis was 4 months, and CMV was the most frequently observed agent. Diabetes was a frequent co-morbidity and several patients with uveitis who developed retinitis were also receiving systemic immunosuppressive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the effect of intraocular straylight (IOS) induced by white opacity filters (WOF) on threshold measurements for stimuli employed in three perimeters: standard automated perimetry (SAP), pulsar perimetry (PP) and the Moorfields motion displacement test (MDT).¦METHODS: Four healthy young (24-28 years old) observers were tested six times with each perimeter, each time with one of five different WOFs and once without, inducing various levels of IOS (from 10% to 200%). An increase in IOS was measured with a straylight meter. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the SD of normative values) for each instrument.¦RESULTS: SAP and PP thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%). The drop in motion displacement (MD) from baseline with WOF 5, was approximately 5 dB, in both SAP and PP which represents a clinically significant loss; in contrast the change in MD with MDT was on average 1 minute of arc, which is not likely to indicate a clinically significant loss.¦CONCLUSIONS: The Moorfields MDT is more robust to the effects of additional straylight in comparison with SAP or PP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The vascular access steal syndrome is a complication occurring in 1-6% after native arterio-venous (AV) fistulas, often due to huge diameter of the vein. This results in very high flow, which could also be responsible for cardiac overload. The aim of this study is to evaluate the efficiency of a new approach in the treatment of this pathology using open-pore external scaffolding prosthesis.Methods: This a retrospective review of all patients presenting symptomatic high flow after native AV fistula between January 2007 and December 2009 in 3 vascular centers. Pre-operative duplex exam confirmed the diagnosis of high flow. The operation consisted in preparation of the whole fistula, measurement of the flow and section on the venous side. The vein was wrapped with this 6 to 8 mm open-pore external scaffolding prosthesis (ProVena, BBraun, Germany) according to its diameter and to the flow and then sutured. Measurement of the flow was repeated. Patients were followed by duplex exam at 1 week and at 1, 3, 6 and 12 months. Procedural success was defined as complete implantation of the prosthesis and reduction of the flow. Primary outcomes were reduction of the flow and recovery of the symptoms and secondary endpoint was patency of the fistula.Results: During the study period, 14 patients, with a mean age of 65・8 years old, have been operated with this technique.There were 2 native forearmfistulas and 12 on the armwith a mean pre-operative flow of 2600 ml/min (1800-3800). The mode of presentation was pain in 6 patients, neurological disorders in 10 and necrosis in 4. Moreover, 3 patients had cardiac insufficiency due to high flow in the fistula. The procedure was technically successful in 100% of cases. Re-intervention was necessary in 2 patients due to hematoma. Recovery of the initial symptoms occurred in 13 patients (93%). The mean flow reduction was 1200 ml/min (600-2000). In 1 patient, a persistent steal syndrome despite flow reduction to 1400 ml/min resulted in fistula closure 2 months later. At a mean follow-up of 22 months (4-35), all remaining patients (13/14) presented a patent fistula without recurrence.Conclusion: This new approach seems to be safe and effective in the treatment of symptomatic high flow native AV fistulas by significantly reducing the flow and avoiding closure of the vascular access. Longer follow-up with more patients are necessary to evaluate the risk of recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We developed a population model that describes the ocular penetration and pharmacokinetics of penciclovir in human aqueous humour and plasma after oral administration of famciclovir. METHODS: Fifty-three patients undergoing cataract surgery received a single oral dose of 500 mg of famciclovir prior to surgery. Concentrations of penciclovir in both plasma and aqueous humour were measured by HPLC with fluorescence detection. Concentrations in plasma and aqueous humour were fitted using a two-compartment model (NONMEM software). Inter-individual and intra-individual variabilities were quantified and the influence of demographics and physiopathological and environmental variables on penciclovir pharmacokinetics was explored. RESULTS: Drug concentrations were fitted using a two-compartment, open model with first-order transfer rates between plasma and aqueous humour compartments. Among tested covariates, creatinine clearance, co-intake of angiotensin-converting enzyme inhibitors and body weight significantly influenced penciclovir pharmacokinetics. Plasma clearance was 22.8 ± 9.1 L/h and clearance from the aqueous humour was 8.2 × 10(-5) L/h. AUCs were 25.4 ± 10.2 and 6.6 ± 1.8 μg · h/mL in plasma and aqueous humour, respectively, yielding a penetration ratio of 0.28 ± 0.06. Simulated concentrations in the aqueous humour after administration of 500 mg of famciclovir three times daily were in the range of values required for 50% growth inhibition of non-resistant strains of the herpes zoster virus family. CONCLUSIONS: Plasma and aqueous penciclovir concentrations showed significant variability that could only be partially explained by renal function, body weight and comedication. Concentrations in the aqueous humour were much lower than in plasma, suggesting that factors in the blood-aqueous humour barrier might prevent its ocular penetration or that redistribution occurs in other ocular compartments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Reconstructions of the fronto-orbital area remain a challenge to the reconstructive surgeon, due to the functional and esthetic impact. OBSERVATION: The authors present a case of a complex fronto-orbital reconstruction with a PEEK (PolyEtherEtherKetone) implant, associated with a skin expansion. DISCUSSION: With a follow-up of over three years, the cosmetic result is excellent. The authors believe that this technique is reliable, fast with long-term good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between September 1979 and December 1982, 56 St Jude Medical valvular prostheses were implanted in 54 patients over 65 years of age. Surgery consisted in simple aortic valve replacement (35 cases), simple mitral valve replacement (12 cases), double aortic and mitral valve replacement (2 cases), valve replacement and coronary artery bypass surgery (3 cases), aortic valve replacement and replacement of the ascending aorta (1 case) and mitral valve replacement and tricuspid annuloplasty (1 case). The operative mortality (within 30 days of surgery) was 3.5% (2 cases). Patients were assessed by clinical examination, ECG, chest X-ray, echocardiogram and laboratory investigations on average 19 months after surgery. There were 3 late deaths (1 endocarditis, 1 cardiac failure and 1 subdural haematoma). No cases of significant haemolysis were observed. There were no cases of thrombosis of the valve or any deaths directly related to the valve. Four patients had cerebral embolism (4.9% per patient/year). None were fatal and only 1 patient had sequellae. Clinical improvement was very significant; 96% of the patients are now in the NYHA Classes I and II whilst 80% were in Class III or IV before surgery. The cardiothoracic ratio decreased significantly from 0.56 to 0.51 (p less than 0.01). The authors conclude that elderly patients may derive great benefits from valvular cardiac surgery and that age in itself is not a contraindication to this type of surgery. The St Jude Medical prosthesis is an excellent prosthesis but thromboembolism remains a major problem as with other mechanical prostheses. Anticoagulation for life is essential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of intraocular administration of nitric oxide (NO) donors in the rabbit eye on intraocular pressure (IOP), inflammation, and toxicity. METHODS: Intravitreal and intracameral injections of two NO donors, SIN-1 and SNAP, and SIN-1C and BSS were performed. Clinical examination, IOP measurements, protein evaluation in aqueous humor, and histologic analysis of the ocular globes were realized. Nitric oxide release was demonstrated by nitrite production in the aqueous humor and in the vitreous using the Griess reaction. RESULTS: The drastic decrease of IOP, observed after a single NO donor injection, was correlated directly with nitrite production and, thus, to NO release. Injection of inactive metabolite of SIN-1, SIN-1C, which is not able to release NO, did not modulate IOP. When administered in the aqueous humor or in the vitreous, NO did not diffuse from one segment of the eye to another. No inflammation or histologic damage was observed as a result of a single NO donor administration. CONCLUSIONS: Nitric oxide is implicated directly in the regulation of IOP and its acute, and massive release into the rabbit eye did not induce inflammation or other growth toxic effects on the ocular tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: : Superselective ophthalmic artery chemotherapy (SOAC) has recently been proposed as an alternative to intravenous chemoreduction for advanced intraocular retinoblastoma. Preliminary results appear promising in terms of tumor control and eye conservation, but little is known regarding ocular toxicity and visual prognosis. In this study, we report on the vascular adverse effects observed in our initial cohort of 13 patients. METHODS: : The charts of 13 consecutive patients with retinoblastoma who received a total of 30 injections (up to 3 injections of a single agent per patient at 3-week interval) of melphalan (0.35 mg/kg) in the ophthalmic artery between November 2008 and June 2010 were retrospectively reviewed. RetCam fundus photography and fluorescein angiography were performed at presentation and before each injection. Vision was assessed at the latest visit. RESULTS: : Enucleation and external beam radiotherapy could be avoided in all cases but one, with a mean follow-up of 7 months. Sectoral choroidal occlusive vasculopathy leading to chorioretinal atrophy was observed temporally in 2 eyes (15%) 3 weeks to 6 weeks after the beginning of SOAC and retinal arteriolar emboli in 1 eye 2 weeks after injection. There was no stroke or other clinically significant systemic side effects except a perioperative transient spasm of the internal carotid artery in one patient. Vision ranged between 20/1600 and 20/32 depending on the status of the macula. CONCLUSION: : Superselective ophthalmic artery chemotherapy was effective in all patients with no stroke or other systemic vascular complications. Unlike intravenous chemoreduction, SOAC is associated with potentially sight-threatening adverse effects, such as severe chorioretinal atrophy secondary to subacute choroidal occlusive vasculopathy or central retinal artery embolism, not to mention the risk of ophthalmic artery obstruction, which was not observed in this series. Further analysis of the risks and benefits of SOAC will define its role within the therapeutic arsenal. Meanwhile, we suggest that SOAC should be given in one eye only and restricted to advanced cases of retinoblastoma, as an alternative to enucleation and/or external beam radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Purpose: We aimed to investigate the safety, tolerability, and systemic diffusion of a single escalating dose of XG-102 (a 31-D-amino-acid peptide inhibiting JNK pathway activation), administered subconjunctivally in the treatment of post-surgery or post-trauma intraocular inflammation. Methods: This is a dose-escalating, tolerance Phase Ib study. Twenty patients with post-surgery or post-traumatic intraocular inflammation were assigned to 1 of the 4 dose escalating (45, 90, 450, or 900 μg XG-102) groups of 5 patients each. Patients were evaluated at 24, 48 h, 8, and 28 days following the administration of XG-102, including laboratory tests, standard eye examinations, vital signs, and occurrence of adverse events. A single plasma quantification of XG-102 was performed 30 min after administration, according to previous pharmacokinetics studies performed on volunteers. Results: A total of 17 non-serious adverse events, considered unrelated to the study treatment, were reported for 10 patients. The adverse event incidence was not related to the drug dose. All patients experienced a decrease in intraocular inflammation as of 24 h post-administration and this decrease was sustained up to 28 days thereafter. No patient required local injection or systemic administration of corticoids following the administration of XG-102. XG-102 was undetectable in the first 3 dose groups. In the fourth-dose group (900 μg) the XG-102 plasma levels were above the limit of detection for 3 patients and above the limit of quantification for 1 patient. Conclusions: In this first clinical trial using XG-102, administered as a single subconjunctival injection as adjunct therapy, in patients with recent post-surgery or post-trauma intraocular inflammation is safe and well tolerated. Further studies are required to evaluate its efficacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.