26 resultados para infrared, spectroscopy


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction ICM+ software encapsulates our 20 years' experience in brain monitoring. It collects data from a variety of bedside monitors and produces time trends of parameters defi ned using confi gurable mathematical formulae. To date it is being used in nearly 40 clinical research centres worldwide. We present its application for continuous monitoring of cerebral autoregulation using near-infrared spectroscopy (NIRS). Methods Data from multiple bedside monitors are processed by ICM+ in real time using a large selection of signal processing methods. These include various time and frequency domain analysis functions as well as fully customisable digital fi lters. The fi nal results are displayed in a variety of ways including simple time trends, as well as time window based histograms, cross histograms, correlations, and so forth. All this allows complex information from bedside monitors to be summarized in a concise fashion and presented to medical and nursing staff in a simple way that alerts them to the development of various pathological processes. Results One hundred and fi fty patients monitored continuously with NIRS, arterial blood pressure (ABP) and intracranial pressure (ICP), where available, were included in this study. There were 40 severely headinjured adult patients, 27 SAH patients (NCCU, Cambridge); 60 patients undergoing cardiopulmonary bypass (John Hopkins Hospital, Baltimore) and 23 patients with sepsis (University Hospital, Basel). In addition, MCA fl ow velocity (FV) was monitored intermittently using transcranial Doppler. FV-derived and ICP-derived pressure reactivity indices (PRx, Mx), as well as NIRS-derived reactivity indices (Cox, Tox, Thx) were calculated and showed signifi cant correlation with each other in all cohorts. Errorbar charts showing reactivity index PRx versus CPP (optimal CPP chart) as well as similar curves for NIRS indices versus CPP and ABP were also demonstrated. Conclusions ICM+ software is proving to be a very useful tool for enhancing the battery of available means for monitoring cerebral vasoreactivity and potentially facilitating autoregulation guided therapy. Complexity of data analysis is also hidden inside loadable profi les, thus allowing investigators to take full advantage of validated protocols including advanced processing formulas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: It is unknown whether cerebral perfusion in geriatric and younger patients under general anaesthesia differs. Methods: We compared 2 groups of patients undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Group 1: 18-40 yrs (n = 20), Group 2: >65 yrs (n = 37). Cerebral perfusion was investigated with transcranial Doppler and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Data are shown as mean } SD. Results: MAP (86 } 9.6 vs 79 } 10.9 mm Hg, p = 0.02), end-tidal concentration of sevoflurane (1.9 } 0.3 vs 1.6 } 0.3%, p <0.01), and the cerebral tissue oxygenation index measured by NIRS (72 } 4 vs 68 } 5%, p = 0.01), were significantly lower in Group 2. The end-tidal concentration of O2 was significantly higher in Group 2 (46 } 4 vs 48 } 4% p = 0.04). There were no significant differences between Group 1 and 2 for cerebral blood flow velocity (41 } 10 vs 43 } 18 cm/s), end tidal CO2 (4.7 } 0.3 vs 4.6 } 0.3 kPa) and cerebrovascular autoregulation (Mx 0.42 } 0.2 vs 0.48 } 0.2). In Group 1 35% and in Group 2 43% of the patients had an index of autoregulation suggesting disturbed cerebrovascular autoregulation (p = n.s.). Conclusions: In elderly patients under general anaesthesia with sevoflurane the cerebral tissue oxygenation index was significantly lower than in younger patients despite higher end-tidal oxygen concentrations. Our data suggest subtle differences in cerebral perfusion between geriatric and younger

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examined the electromyographic, cerebral and muscle hemodynamic responses during intermittent isometric contractions of biceps brachii at 20, 40, and 60% of maximal voluntary contraction (MVC). Eleven volunteers completed 2 min of intermittent isometric contractions (12/min) at an elbow angle of 90° interspersed with 3 min rest between intensities in systematic order. Surface electromyography (EMG) was recorded from the right biceps brachii and near infrared spectroscopy (NIRS) was used to simultaneously measure left prefrontal and right biceps brachii oxyhemoglobin (HbO2), deoxyhemoglobin (HHb), and total hemoglobin (Hbtot). Transcranial Doppler ultrasound was used to measure middle cerebral artery velocity (MCAv) bilaterally. Finger photoplethysmography was used to record beat-to-beat blood pressure and heart rate. EMG increased with force output from 20 to 60% MVC (P < 0.05). Cerebral HbO2 and Hbtot increased while HHb decreased during contractions with differences observed between 60% vs. 40% and 20% MVC (P < 0.05). Muscle HbO2 decreased while HHb increased during contractions with differences being observed among intensities (P < 0.05). Muscle Hbtot increased from rest at 20% MVC (P < 0.05), while no further change was observed at 40 and 60% MVC (P > 0.05). MCAv increased from rest to exercise but was not different among intensities (P > 0.05). Force output correlated with the root mean square EMG and changes in muscle HbO2 (P < 0.05), but not changes in cerebral HbO2 (P > 0.05) at all three intensities. Force output declined by 8% from the 1st to the 24th contraction only at 60% MVC and was accompanied by systematic increases in RMS, cerebral HbO2 and Hbtot with a leveling off in muscle HbO2 and Hbtot. These changes were independent of alterations in mean arterial pressure. Since cerebral blood flow and oxygenation were elevated at 60% MVC, we attribute the development of fatigue to reduced muscle oxygen availability rather than impaired central neuronal activation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Management of neurocritical care patients is focused on the prevention and treatment of secondary brain injury, i.e. the number of pathophysiological intracerebral (edema, ischemia, energy dysfunction, seizures) and systemic (hyperthermia, disorders of glucose homeostasis) events that occur following the initial insult (stroke, hemorrhage, head trauma, brain anoxia) that may aggravate patient outcome. The current therapeutic paradigm is based on multimodal neuromonitoring, including invasive (intracranial pressure, brain oxygen, cerebral microdialysis) and non-invasive (transcranial doppler, near-infrared spectroscopy, EEG) tools that allows targeted individualized management of acute coma in the early phase. The aim of this review is to describe the utility of multimodal neuromonitoring for the critical care management of acute coma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: This study aimed to determine the neuro-mechanical and metabolic adjustments in the lower limbs induced by the running anaerobic sprint test (the so-called RAST). METHODS: Eight professional football players performed 6 × 35 m sprints interspersed with 10 s of active recovery on artificial turf with their football shoes. Sprinting mechanics (plantar pressure insoles), root mean square activity of the vastus lateralis (VL), rectus femoris (RF), and biceps femoris (BF) muscles (surface electromyography, EMG) and VL muscle oxygenation (near-infrared spectroscopy) were monitored continuously. RESULTS: Sprint time, contact time and total stride duration increased from the first to the last repetition (+17.4, +20.0 and +16.6 %; all P < 0.05), while flight time and stride length remained constant. Stride frequency (-13.9 %; P < 0.001) and vertical stiffness decreased (-27.2 %; P < 0.001) across trials. Root mean square EMG activities of RF and BF (-18.7 and -18.1 %; P < 0.01 and 0.001, respectively), but not VL (-1.2 %; P > 0.05), decreased over sprint repetitions and were correlated with the increase in running time (r = -0.82 and -0.90; both P < 0.05). Together with a better maintenance of RF and BF muscles activation levels over sprint repetitions, players with a better repeated-sprint performance (lower cumulated times) also displayed faster muscle de- (during sprints) and re-oxygenation (during recovery) rates (r = -0.74 and -0.84; P < 0.05 and 0.01, respectively). CONCLUSION: The repeated anaerobic sprint test leads to substantial alterations in stride mechanics and leg-spring behaviour. Our results also strengthen the link between repeated-sprint ability and the change in neuromuscular activation as well as in muscle de- and re-oxygenation rates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In traffic accidents involving motorcycles, paint traces can be transferred from the rider's helmet or smeared onto its surface. These traces are usually in the form of chips or smears and are frequently collected for comparison purposes. This research investigates the physical and chemical characteristics of the coatings found on motorcycles helmets. An evaluation of the similarities between helmet and automotive coating systems was also performed.Twenty-seven helmet coatings from 15 different brands and 22 models were considered. One sample per helmet was collected and observed using optical microscopy. FTIR spectroscopy was then used and seven replicate measurements per layer were carried out to study the variability of each coating system (intravariability). Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were also performed on the infrared spectra of the clearcoats and basecoats of the data set. The most common systems were composed of two or three layers, consistently involving a clearcoat and basecoat. The coating systems of helmets with composite shells systematically contained a minimum of three layers. FTIR spectroscopy results showed that acrylic urethane and alkyd urethane were the most frequent binders used for clearcoats and basecoats. A high proportion of the coatings were differentiated (more than 95%) based on microscopic examinations. The chemical and physical characteristics of the coatings allowed the differentiation of all but one pair of helmets of the same brand, model and color. Chemometrics (PCA and HCA) corroborated classification based on visual comparisons of the spectra and allowed the study of the whole data set at once (i.e., all spectra of the same layer). Thus, the intravariability of each helmet and its proximity to the others (intervariability) could be more readily assessed. It was also possible to determine the most discriminative chemical variables based on the study of the PCA loadings. Chemometrics could therefore be used as a complementary decision-making tool when many spectra and replicates have to be taken into account. Similarities between automotive and helmet coating systems were highlighted, in particular with regard to automotive coating systems on plastic substrates (microscopy and FTIR). However, the primer layer of helmet coatings was shown to differ from the automotive primer. If the paint trace contains this layer, the risk of misclassification (i.e., helmet versus vehicle) is reduced. Nevertheless, a paint examiner should pay close attention to these similarities when analyzing paint traces, especially regarding smears or paint chips presenting an incomplete layer system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La spectroscopie infrarouge (FTIR) est une technique de choix dans l'analyse des peintures en spray (traces ou bonbonnes de référence), grâce à son fort pouvoir discriminant, sa sensibilité, et ses nombreuses possibilités d'échantillonnage. La comparaison des spectres obtenus est aujourd'hui principalement faite visuellement, mais cette procédure présente des limitations telles que la subjectivité de la prise de décision car celle-ci dépend de l'expérience et de la formation suivie par l'expert. De ce fait, de faibles différences d'intensités relatives entre deux pics peuvent être perçues différemment par des experts, même au sein d'un même laboratoire. Lorsqu'il s'agit de justifier ces différences, certains les expliqueront par la méthode analytique utilisée, alors que d'autres estimeront plutôt qu'il s'agit d'une variabilité intrinsèque à la peinture et/ou à son vécu (par exemple homogénéité, sprayage, ou dégradation). Ce travail propose d'étudier statistiquement les différentes sources de variabilité observables dans les spectres infrarouges, de les identifier, de les comprendre et tenter de les minimiser. Le deuxième objectif principal est de proposer une procédure de comparaison des spectres qui soit davantage transparente et permette d'obtenir des réponses reproductibles indépendamment des experts interrogés. La première partie du travail traite de l'optimisation de la mesure infrarouge et des principaux paramètres analytiques. Les conditions nécessaires afin d'obtenir des spectres reproductibles et minimisant la variation au sein d'un même échantillon (intra-variabilité) sont présentées. Par la suite une procédure de correction des spectres est proposée au moyen de prétraitements et de sélections de variables, afin de minimiser les erreurs systématiques et aléatoires restantes, et de maximiser l'information chimique pertinente. La seconde partie présente une étude de marché effectuée sur 74 bonbonnes de peintures en spray représentatives du marché suisse. Les capacités de discrimination de la méthode FTIR au niveau de la marque et du modèle sont évaluées au moyen d'une procédure visuelle, et comparées à diverses procédures statistiques. Les limites inférieures de discrimination sont testées sur des peintures de marques et modèles identiques mais provenant de différents lots de production. Les résultats ont montré que la composition en pigments était particulièrement discriminante, à cause des étapes de corrections et d'ajustement de la couleur subies lors de la production. Les particularités associées aux peintures en spray présentes sous forme de traces (graffitis, gouttelettes) ont également été testées. Trois éléments sont mis en évidence et leur influence sur le spectre infrarouge résultant testée : 1) le temps minimum de secouage nécessaire afin d'obtenir une homogénéité suffisante de la peinture et, en conséquence, de la surface peinte, 2) la dégradation initiée par le rayonnement ultra- violet en extérieur, et 3) la contamination provenant du support lors du prélèvement. Finalement une étude de population a été réalisée sur 35 graffitis de la région lausannoise et les résultats comparés à l'étude de marché des bonbonnes en spray. La dernière partie de ce travail s'est concentrée sur l'étape de prise de décision lors de la comparaison de spectres deux-à-deux, en essayant premièrement de comprendre la pratique actuelle au sein des laboratoires au moyen d'un questionnaire, puis de proposer une méthode statistique de comparaison permettant d'améliorer l'objectivité et la transparence lors de la prise de décision. Une méthode de comparaison basée sur la corrélation entre les spectres est proposée, et ensuite combinée à une évaluation Bayesienne de l'élément de preuve au niveau de la source et au niveau de l'activité. Finalement des exemples pratiques sont présentés et la méthodologie est discutée afin de définir le rôle précis de l'expert et des statistiques dans la procédure globale d'analyse des peintures. -- Infrared spectroscopy (FTIR) is a technique of choice for analyzing spray paint speciments (i.e. traces) and reference samples (i.e. cans seized from suspects) due to its high discriminating power, sensitivity and sampling possibilities. The comparison of the spectra is currently carried out visually, but this procedure has limitations such as the subjectivity in the decision due to its dependency on the experience and training of the expert. This implies that small differences in the relative intensity of two peaks can be perceived differently by experts, even between analysts working in the same laboratory. When it comes to justifying these differences, some will explain them by the analytical technique, while others will estimate that the observed differences are mostly due to an intrinsic variability from the paint sample and/or its acquired characteristics (for example homogeneity, spraying, or degradation). This work proposes to statistically study the different sources of variability observed in infrared spectra, to identify them, understand them and try to minimize them. The second goal is to propose a procedure for spectra comparison that is more transparent, and allows obtaining reproducible answers being independent from the expert. The first part of the manuscript focuses on the optimization of infrared measurement and on the main analytical parameters. The necessary conditions to obtain reproducible spectra with a minimized variation within a sample (intra-variability) are presented. Following that a procedure of spectral correction is then proposed using pretreatments and variable selection methods, in order to minimize systematic and random errors, and increase simultaneously relevant chemical information. The second part presents a market study of 74 spray paints representative of the Swiss market. The discrimination capabilities of FTIR at the brand and model level are evaluated by means of visual and statistical procedures. The inferior limits of discrimination are tested on paints coming from the same brand and model, but from different production batches. The results showed that the pigment composition was particularly discriminatory, because of the corrections and adjustments made to the paint color during its manufacturing process. The features associated with spray paint traces (graffitis, droplets) were also tested. Three elements were identified and their influence on the resulting infrared spectra were tested: 1) the minimum shaking time necessary to obtain a sufficient homogeneity of the paint and subsequently of the painted surface, 2) the degradation initiated by ultraviolet radiation in an exterior environment, and 3) the contamination from the support when paint is recovered. Finally a population study was performed on 35 graffitis coming from the city of Lausanne and surroundings areas, and the results were compared to the previous market study of spray cans. The last part concentrated on the decision process during the pairwise comparison of spectra. First, an understanding of the actual practice among laboratories was initiated by submitting a questionnaire. Then, a proposition for a statistical method of comparison was advanced to improve the objectivity and transparency during the decision process. A method of comparison based on the correlation between spectra is proposed, followed by the integration into a Bayesian framework at both source and activity levels. Finally, some case examples are presented and the recommended methodology is discussed in order to define the role of the expert as well as the contribution of the tested statistical approach within a global analytical sequence for paint examinations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Brain injury is frequently observed after sepsis and may be primarily related to the direct effects of the septic insult on the brain (e.g., brain edema, ischemia, seizures) or to secondary/indirect injuries (e.g., hypotension, hypoxemia, hypocapnia, hyperglycemia). Management of brain injury in septic patients is first focused to exclude structural intracranial complications (e.g., ischemic/hemorrhagic stroke) and possible confounders (e.g., electrolyte alterations or metabolic disorders, such as dysglycemia). Sepsis-associated brain dysfunction is frequently a heterogeneous syndrome. Despite increasing understanding of main pathophysiologic determinants, therapy is essentially limited to protect the brain against further cerebral damage, by way of "simple" therapeutic manipulations of cerebral perfusion and oxygenation and by avoiding over-sedation. Non-invasive monitoring of cerebral perfusion and oxygenation with transcranial Doppler (TCD) and near-infrared spectroscopy (NIRS) is feasible in septic patients. Electroencephalography (EEG) allows detection of sepsis-related seizures and holds promise also as sedation monitoring. Brain CT-scan detects intra-cerebral structural lesions, while magnetic resonance imaging (MRI) provides important insights into primary mechanisms of sepsis-related direct brain injury, (e.g., cytotoxic vs. vasogenic edema) and the development of posterior reversible encephalopathy. Together with EEG and evoked potentials (EP), MRI is also important for coma prognostication. Emerging clinical evidence suggests monitoring of the brain in septic patients can be implemented in the ICU. The objective of this review was to summarize recent clinical data about the role of brain monitoring - including TCD, NIRS, EEG, EP, CT, and MRI - in patients with sepsis and to illustrate its potential utility for the diagnosis, management and prognostication.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

«Quel est l'âge de cette trace digitale?» Cette question est relativement souvent soulevée au tribunal ou lors d'investigations, lorsque la personne suspectée admet avoir laissé ses empreintes digitales sur une scène de crime mais prétend l'avoir fait à un autre moment que celui du crime et pour une raison innocente. Toutefois, aucune réponse ne peut actuellement être donnée à cette question, puisqu'aucune méthodologie n'est pour l'heure validée et acceptée par l'ensemble de la communauté forensique. Néanmoins, l'inventaire de cas américains conduit dans cette recherche a montré que les experts fournissent tout de même des témoignages au tribunal concernant l'âge de traces digitales, même si ceux-­‐ci sont majoritairement basés sur des paramètres subjectifs et mal documentés. Il a été relativement aisé d'accéder à des cas américains détaillés, ce qui explique le choix de l'exemple. Toutefois, la problématique de la datation des traces digitales est rencontrée dans le monde entier, et le manque de consensus actuel dans les réponses données souligne la nécessité d'effectuer des études sur le sujet. Le but de la présente recherche est donc d'évaluer la possibilité de développer une méthode de datation objective des traces digitales. Comme les questions entourant la mise au point d'une telle procédure ne sont pas nouvelles, différentes tentatives ont déjà été décrites dans la littérature. Cette recherche les a étudiées de manière critique, et souligne que la plupart des méthodologies reportées souffrent de limitations prévenant leur utilisation pratique. Néanmoins, certaines approches basées sur l'évolution dans le temps de composés intrinsèques aux résidus papillaires se sont montrées prometteuses. Ainsi, un recensement détaillé de la littérature a été conduit afin d'identifier les composés présents dans les traces digitales et les techniques analytiques capables de les détecter. Le choix a été fait de se concentrer sur les composés sébacés détectés par chromatographie gazeuse couplée à la spectrométrie de masse (GC/MS) ou par spectroscopie infrarouge à transformée de Fourier. Des analyses GC/MS ont été menées afin de caractériser la variabilité initiale de lipides cibles au sein des traces digitales d'un même donneur (intra-­‐variabilité) et entre les traces digitales de donneurs différents (inter-­‐variabilité). Ainsi, plusieurs molécules ont été identifiées et quantifiées pour la première fois dans les résidus papillaires. De plus, il a été déterminé que l'intra-­‐variabilité des résidus était significativement plus basse que l'inter-­‐variabilité, mais que ces deux types de variabilité pouvaient être réduits en utilisant différents pré-­‐ traitements statistiques s'inspirant du domaine du profilage de produits stupéfiants. Il a également été possible de proposer un modèle objectif de classification des donneurs permettant de les regrouper dans deux classes principales en se basant sur la composition initiale de leurs traces digitales. Ces classes correspondent à ce qui est actuellement appelé de manière relativement subjective des « bons » ou « mauvais » donneurs. Le potentiel d'un tel modèle est élevé dans le domaine de la recherche en traces digitales, puisqu'il permet de sélectionner des donneurs représentatifs selon les composés d'intérêt. En utilisant la GC/MS et la FTIR, une étude détaillée a été conduite sur les effets de différents facteurs d'influence sur la composition initiale et le vieillissement de molécules lipidiques au sein des traces digitales. Il a ainsi été déterminé que des modèles univariés et multivariés pouvaient être construits pour décrire le vieillissement des composés cibles (transformés en paramètres de vieillissement par pré-­‐traitement), mais que certains facteurs d'influence affectaient ces modèles plus sérieusement que d'autres. En effet, le donneur, le substrat et l'application de techniques de révélation semblent empêcher la construction de modèles reproductibles. Les autres facteurs testés (moment de déposition, pression, température et illumination) influencent également les résidus et leur vieillissement, mais des modèles combinant différentes valeurs de ces facteurs ont tout de même prouvé leur robustesse dans des situations bien définies. De plus, des traces digitales-­‐tests ont été analysées par GC/MS afin d'être datées en utilisant certains des modèles construits. Il s'est avéré que des estimations correctes étaient obtenues pour plus de 60 % des traces-­‐tests datées, et jusqu'à 100% lorsque les conditions de stockage étaient connues. Ces résultats sont intéressants mais il est impératif de conduire des recherches supplémentaires afin d'évaluer les possibilités d'application de ces modèles dans des cas réels. Dans une perspective plus fondamentale, une étude pilote a également été effectuée sur l'utilisation de la spectroscopie infrarouge combinée à l'imagerie chimique (FTIR-­‐CI) afin d'obtenir des informations quant à la composition et au vieillissement des traces digitales. Plus précisément, la capacité de cette technique à mettre en évidence le vieillissement et l'effet de certains facteurs d'influence sur de larges zones de traces digitales a été investiguée. Cette information a ensuite été comparée avec celle obtenue par les spectres FTIR simples. Il en a ainsi résulté que la FTIR-­‐CI était un outil puissant, mais que son utilisation dans l'étude des résidus papillaires à des buts forensiques avait des limites. En effet, dans cette recherche, cette technique n'a pas permis d'obtenir des informations supplémentaires par rapport aux spectres FTIR traditionnels et a également montré des désavantages majeurs, à savoir de longs temps d'analyse et de traitement, particulièrement lorsque de larges zones de traces digitales doivent être couvertes. Finalement, les résultats obtenus dans ce travail ont permis la proposition et discussion d'une approche pragmatique afin d'aborder les questions de datation des traces digitales. Cette approche permet ainsi d'identifier quel type d'information le scientifique serait capable d'apporter aux enquêteurs et/ou au tribunal à l'heure actuelle. De plus, le canevas proposé décrit également les différentes étapes itératives de développement qui devraient être suivies par la recherche afin de parvenir à la validation d'une méthodologie de datation des traces digitales objective, dont les capacités et limites sont connues et documentées. -- "How old is this fingermark?" This question is relatively often raised in trials when suspects admit that they have left their fingermarks on a crime scene but allege that the contact occurred at a time different to that of the crime and for legitimate reasons. However, no answer can be given to this question so far, because no fingermark dating methodology has been validated and accepted by the whole forensic community. Nevertheless, the review of past American cases highlighted that experts actually gave/give testimonies in courts about the age of fingermarks, even if mostly based on subjective and badly documented parameters. It was relatively easy to access fully described American cases, thus explaining the origin of the given examples. However, fingermark dating issues are encountered worldwide, and the lack of consensus among the given answers highlights the necessity to conduct research on the subject. The present work thus aims at studying the possibility to develop an objective fingermark dating method. As the questions surrounding the development of dating procedures are not new, different attempts were already described in the literature. This research proposes a critical review of these attempts and highlights that most of the reported methodologies still suffer from limitations preventing their use in actual practice. Nevertheless, some approaches based on the evolution of intrinsic compounds detected in fingermark residue over time appear to be promising. Thus, an exhaustive review of the literature was conducted in order to identify the compounds available in the fingermark residue and the analytical techniques capable of analysing them. It was chosen to concentrate on sebaceous compounds analysed using gas chromatography coupled with mass spectrometry (GC/MS) or Fourier transform infrared spectroscopy (FTIR). GC/MS analyses were conducted in order to characterize the initial variability of target lipids among fresh fingermarks of the same donor (intra-­‐variability) and between fingermarks of different donors (inter-­‐variability). As a result, many molecules were identified and quantified for the first time in fingermark residue. Furthermore, it was determined that the intra-­‐variability of the fingermark residue was significantly lower than the inter-­‐variability, but that it was possible to reduce both kind of variability using different statistical pre-­‐ treatments inspired from the drug profiling area. It was also possible to propose an objective donor classification model allowing the grouping of donors in two main classes based on their initial lipid composition. These classes correspond to what is relatively subjectively called "good" or "bad" donors. The potential of such a model is high for the fingermark research field, as it allows the selection of representative donors based on compounds of interest. Using GC/MS and FTIR, an in-­‐depth study of the effects of different influence factors on the initial composition and aging of target lipid molecules found in fingermark residue was conducted. It was determined that univariate and multivariate models could be build to describe the aging of target compounds (transformed in aging parameters through pre-­‐ processing techniques), but that some influence factors were affecting these models more than others. In fact, the donor, the substrate and the application of enhancement techniques seemed to hinder the construction of reproducible models. The other tested factors (deposition moment, pressure, temperature and illumination) also affected the residue and their aging, but models combining different values of these factors still proved to be robust. Furthermore, test-­‐fingermarks were analysed with GC/MS in order to be dated using some of the generated models. It turned out that correct estimations were obtained for 60% of the dated test-­‐fingermarks and until 100% when the storage conditions were known. These results are interesting but further research should be conducted to evaluate if these models could be used in uncontrolled casework conditions. In a more fundamental perspective, a pilot study was also conducted on the use of infrared spectroscopy combined with chemical imaging in order to gain information about the fingermark composition and aging. More precisely, its ability to highlight influence factors and aging effects over large areas of fingermarks was investigated. This information was then compared with that given by individual FTIR spectra. It was concluded that while FTIR-­‐ CI is a powerful tool, its use to study natural fingermark residue for forensic purposes has to be carefully considered. In fact, in this study, this technique does not yield more information on residue distribution than traditional FTIR spectra and also suffers from major drawbacks, such as long analysis and processing time, particularly when large fingermark areas need to be covered. Finally, the results obtained in this research allowed the proposition and discussion of a formal and pragmatic framework to approach the fingermark dating questions. It allows identifying which type of information the scientist would be able to bring so far to investigators and/or Justice. Furthermore, this proposed framework also describes the different iterative development steps that the research should follow in order to achieve the validation of an objective fingermark dating methodology, whose capacities and limits are well known and properly documented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a preliminary study on the degradation of spray paint samples, illustrated by Optical, FTIR and Raman measurements. As opposed to automotive paints which are specifically designed for improved outdoor exposure and protected using hindered amine light absorbers (HALS) and ultra-violet absorbers (UVA), the spray paints on their side are much simpler in composition and very likely to suffer more from joint effects of solar radiation, temperature and humidity. Six different spray paint were exposed to outdoor UV-radiation for a total period of three months and both FTIR and Raman measurements were taken systematically during this time. These results were later compared to an artificial degradation using a climate chamber. For infrared spectroscopy, degradation curves were plotted using the photo-oxidation index (POI), and could be successfully approximated with a logarithmic fitting (R2 > 0.8). The degradation can appear after the first few days of exposure and be important until 2 months, where it stabilizes and follow a more linear trend afterwards. One advantage is that the degradation products appeared almost exclusively at the far end (∼3000 cm−1) of mid-infrared spectra, and that the fingerprint region of the spectra remained stable over the studied period of time. Raman results suggest that the pigments on the other side, are much more stable and have not shown any sign of degradation over the time of this study. Considering the forensic implications of this environmental degradation, care should be taken when comparing samples if weathering is an option (e.g. an exposed graffiti compared to the paint from a fresh spray paint can). Degradation issues should be kept in mind as they may induce significant differences between paint samples of common origin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cuticle is an essential diffusion barrier on aerial surfaces of land plants whose structural component is the polyester cutin. The PERMEABLE CUTICLE1/ABCG32 (PEC1) transporter is involved in plant cuticle formation in Arabidopsis. The gpat6 pec1 and gpat4 gapt8 pec1 double and triple mutants are characterized. Their PEC1-specific contributions to aliphatic cutin composition and cuticle formation during plant development are revealed by gas chromatography/mass spectrometry and Fourier-transform infrared spectroscopy. The composition of cutin changes during rosette leaf expansion in Arabidopsis. C16:0 monomers are in higher abundance in expanding than in fully expanded leaves. The atypical cutin monomer C18:2 dicarboxylic acid is more prominent in fully expanded leaves. Findings point to differences in the regulation of several pathways of cutin precursor synthesis. PEC1 plays an essential role during expansion of the rosette leaf cuticle. The reduction of C16 monomers in the pec1 mutant during leaf expansion is unlikely to cause permeability of the leaf cuticle because the gpat6 mutant with even fewer C16:0 monomers forms a functional rosette leaf cuticle at all stages of development. PEC1/ABCG32 transport activity affects cutin composition and cuticle structure in a specific and non-redundant fashion.