147 resultados para iliac aneurysm


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Extrahepatic Portal vein aneurysm (EPVA) is a rare finding that may be associated with different complications, e.g. thrombosis, rupture, portal hypertension and compression of adjacent structures. It is being diagnosed more frequently with the advent of modern cross-sectional imaging. Our review of the English literature disclosed 13 cases of thrombosed EPVA. CASE PRESENTATION: A 50-years-old woman presented with acute abdominal pain but no other symptom. She had no relevant medical history. Palpation of the right upper quadrant showed tenderness. Laboratory tests were unremarkable. A computed tomography showed portal vein aneurysm measuring 88 × 65 mm with thrombosis extending to the superior mesenteric and splenic vein. The patient was treated conservatively with anticoagulation therapy. She was released after two weeks and followed on an outpatient basis. At two months, she reported decreased abdominal pain and her physical examination was normal. A computed tomography was performed showing a decreased thrombosis size and extent, measuring 80 × 55 mm. CONCLUSIONS: Although rare, surgeons should be made aware of this entity. Complications are various. Conservative therapy should be chosen in first intent in most cases. We reported the case of the second largest thrombosed extra-hepatic PVA described in the literature, treated by anticoagulation therapy with a good clinical and radiological response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stent implantation was performed on two patients to treat chronic dissecting aneurysms of the upper cervical internal carotid artery. Treatment was decided because of the youth of the patients, their medical history of subarachnoid hemorrhage, and the angiographic findings associated with the dissection. Normal arteriographic morphology was obtained after deployment of a single self-expandable stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report our results of endovascular aneurysm repair (EVAR) over a 10-year period using systematic preoperative collateral artery embolization. METHODS: From 1999 until 2009, 124 patients (117 men; mean age 70.8 years) with abdominal aortic aneurysm (AAA) underwent embolization of patent lumbar and/or inferior mesenteric arteries prior to elective EVAR procedures. Embolization was systematically attempted and, whenever possible, performed using microcoils and a coaxial technique. Follow-up included computed tomography and/or magnetic resonance imaging and abdominal radiography. RESULTS: The technical success for EVAR was 96% (119/124), with 4 patients dying within 30 days (3.2% perioperative mortality) and 1 type III endoleak accounting for the failures. Collateral arteries were occluded spontaneously or by embolization in 60 (48%) of 124 patients. The endoleak rate was 50.9% (74 in 61 patients), most of which were type II (19%). Over a mean clinical follow-up of 60.5±34.1 months (range 1-144), aneurysm sac dimensions decreased in 66 patients, increased in 19 patients, and were stable in 35. The endoleak rate was significantly higher in the patients with increasing sac diameter (p<0.001). Among the patients with patent collateral arteries, 38/64 (59.3%) developed 46 leaks, while 28 leaks appeared in 23 (41%) of 56 patients with collateral artery occlusion (p=0.069). The type II endoleak rate significantly differed between these two groups (47.8% vs. 3.6%, p<0.001). CONCLUSION: Preoperative collateral embolization seems to be a valid method of reducing the incidence of type II endoleak, improving the long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The morbidity of bone graft harvesting from the iliac crest has been widely discussed in the literature. For some authors, it is considered to be low and for others relatively high. We report on a case of a fracture of the iliac wing after graft harvesting from the anterior iliac crest despite good surgical technique. This complication is well known and most of these fractures heal uneventfully if treated conservatively. However, if anatomical and technical considerations are respected, the patient could be spared this inconvenience. Based on a literature review, we discuss the procedure's potential complications and how to avoid them in an update.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Primary venous aneurysm is a rare, but essential consideration in the differential diagnosis of an inguinal and femoral hernia. METHODS: We report a case of a 43-year-old man who was referred for evaluation and treatment of a femoral hernia. RESULTS: The patient presented with a 3-month history of an asymptomatic tumor on his right upper inner thigh. Physical examination noted a non-tender, non-indurated tumor. CONCLUSION: Surgical exploration demonstrated a primary venous aneurysm of the proximal saphenous vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Management of ischemic stroke in the presence of aneurysmal brain disease is controversial. Recent retrospective evidence suggests that in selected patients, intravenous thrombolysis (IVT) remains a safe approach for reperfusion. METHODS: We document a case of post-thrombolysis aneurysmal rupture. Supported by additional scientific literature we postulate that acute aneurysmal thrombosis leading to stroke in the culprit artery may be an ominous sign of rupture and should be considered separately from fortuitously discovered distant aneurysmal disease. RESULTS: A 71-year-old female presented with an acute right middle cerebral artery stroke syndrome. IVT allowed vessel reperfusion and revealed a previously concealed, juxtaposed non-giant M1 segment saccular aneurysm. Secondary aneurysmal rupture ensued. The aneurysm was secured by surgical clipping. Postoperative course was uneventful. CONCLUSIONS: This case shows that despite reports of thrombolysis safety in the presence of brain aneurysms, thrombolysis remains potentially hazardous and hints toward an increased risk when the stroke arises on the parent vessel itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suite à des essais cliniques randomisés démontrant l'efficacité du dépistage de l'anévrisme de l'aorte abdominale (AAA) par échographie, plusieurs recommandations ont été publiées dans de nombreux pays en faveur du dépistage dans une partie de la population générale. De plus, au-delà de la rupture aortique, le dépistage d'un petit AAA semble être une bonne occasion d'appliquer les stratégies de prévention secondaire, permettant une amélioration globale du pronostic cardiovasculaire du patient. Ces recommandations sont cependant peu suivies; les campagnes de dépistage systématique sont rares, laissant la responsabilité du dépistage au médecin généraliste. Cet article se propose de discuter les raisons de la non-implantation du dépistage de l'AAA. [Abstract] Following the evidence of benefits of ultrasound screening for abdominal aorta aneurysms (AAA), several guidelines support this screening in population. Beyond the prompt diagnosis of AAA prior to its rupture of grim vital prognosis, small AAA can beconsidered as a prognostic marker for cardiovascular diseases (CVD). Yet, its detection is an opportunity for secondary prevention to reduce CVD mortality. Despite, these guidelines are poorly applied: systematic screening campaigns are infrequent, making the screening of family physicians responsibility. While the major benefit from this screening strategy is to reduce AAA-related death (but only trivial effect on long-term total mortality), this explains only partially the lack of guidelines implementation. The reasons of the poor implementation of these guidelines are discussed herein.