47 resultados para doses de resíduo
Resumo:
The development of CT applications might become a public health problem if no effort is made on the justification and the optimisation of the examinations. This paper presents some hints to assure that the risk-benefit compromise remains in favour of the patient, especially when one deals with the examinations of young patients. In this context a particular attention has to be made on the justification of the examination. When performing the acquisition one needs to optimise the extension of the volume investigated together with the number of acquisition sequences used. Finally, the use of automatic exposure systems, now available on all the units, and the use of the Diagnostic Reference Levels (DRL) should allow help radiologists to control the exposure of their patients.
Resumo:
Recent recommendations for the prophylaxis of endocarditis in humans have advocated single doses or short courses of antibiotic combinations (beta-lactam plus aminoglycoside) for susceptible patients in whom enterococcal bacteremia might develop or for patients at especially high risk of developing endocarditis (e.g., patients with prosthetic cardiac valves). We tested the prophylactic efficacy (in rats with catheter-induced aortic vegetations) of single doses of amoxicillin plus gentamicin against challenge with various streptococcal strains (two strains of Streptococcus faecalis, one of Streptococcus bovis, and three of viridans streptococci); we then compared this efficacy with that of single doses of amoxicillin alone. Successful prophylaxis against all six strains was achieved with single doses of both amoxicillin alone and amoxicillin plus gentamicin. This protection, however, was limited, for both regimens, to the lowest bacterial-inoculum size producing endocarditis in 90% of control rats and was not extended to higher inocula by using the combination of antibiotics. We concluded that a single dose of amoxicillin alone was protective against enterococcal and nonenterococcal endocarditis in the rat, but that its efficacy was limited and could not be improved by the simultaneous administration of gentamicin.
Resumo:
A new, orally active angiotensin converting enzyme (ACE) inhibitor, CGS 14824A, was evaluated in 12 healthy male volunteers. Two groups each of 6 volunteers were given 5 or 10 mg once daily p.o. for 8 days. Four hours after the first and the last morning doses, plasma angiotensin II, aldosterone and plasma converting enzyme activity had fallen, while blood angiotensin I and plasma renin activity had risen. Throughout the study, more than 90% inhibition of ACE was found immediately before giving either the 5 or 10 mg dose and 50% blockade was still present 72 h following the last dose. Based on the determination of ACE, there was no evidence of drug accumulation. No significant change in blood pressure or heart rate was observed during the course of the study. CGS 14824A was an effective, orally active, long-lasting and well tolerated converting enzyme inhibitor.
Resumo:
The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).
Resumo:
Anabolic androgenic steroids (AAS) are doping agents that are mostly used for improvement of strength and muscle hypertrophy. In some sports, athletes reported that the intake of AAS is associated with a better recovery, a higher training load capacity and therefore an increase in physical and mental performances. The purpose of this study was to evaluate, the effect of multiple doses of AAS on different physiological parameters that could indirectly relate the physical state of athletes during a hard endurance training program. In a double blind settings, three groups (n = 9, 8 and 8) were orally administered placebo, testosterone undecanoate or 19-norandrostenedione, 12 times during 1 month. Serum biomarkers (creatine kinase, ASAT and urea), serum hormone profiles (testosterone, cortisol and LH) and urinary catecholamines (noradrenalin, adrenalin and dopamine) were evaluated during the treatment. Running performance was assessed before and after the intervention phase by means of a standardized treadmill test. None of the measured biochemical variables showed significant impact of AAS on physical stress level. Data from exercise testing on submaximal and maximal level did not reveal any performance differences between the three groups or their response to the treatment. In the present study, no effect of multiple oral doses of AAS on endurance performance or bioserum recovery markers was found.
Resumo:
In 2003, the Swiss guidelines to prevent vitamin K deficiency bleeding (VKDB) were adapted. As two oral doses (2 mg, hour/day 4) of mixed micellar VK preparation had failed to abolish late VKDB, a third dose (week 4) was introduced. This report summarizes the new guidelines acceptance by Swiss pediatricians and the results of a prospective 6-year surveillance to study their influence on the incidence of VKDB. The new guidelines acceptance by Swiss pediatricians was evaluated by a questionnaire sent to all pediatricians of the Swiss Society of Paediatrics. With the help of the Swiss Paediatric Surveillance Unit, the incidence of VKDB was monitored prospectively from July 1, 2005 until June 30, 2011. Over a 6-year period (458,184 live births), there was one case of early and four cases of late VKDB. Overall incidence was 1.09/10(5) (95 % confidence intervals (CI) 0.4-2.6). Late VKDB incidence was 0.87/10(5) (95 % CI 0.24-2.24). All four infants with late VKDB had an undiagnosed cholestasis at the time of bleeding; parents of 3/4 had refused VK prophylaxis, and in 1/4, the third VK dose had been forgotten. Compared with historical control who had received only two oral doses of mixed micellar VK (18 cases for 475,372 live births), the incidence of late VKDB was significantly lower with three oral doses (Chi(2),Yates correction, P = 0.007). CONCLUSION: VKDB prophylaxis with 3 × 2 mg oral doses of mixed micellar VK seems to prevent adequately infants from VKDB. The main risk factors for VKDB in breast-fed infants are parental VK prophylaxis refusal or an unknown cholestasis.
Resumo:
BACKGROUND: In alcohol withdrawal, fixed doses of benzodiazepine are generally recommended as a first-line pharmacologic approach. This study determines the benefits of an individualized treatment regimen on the quantity of benzodiazepine administered and the duration of its use during alcohol withdrawal treatment. METHODS: We conducted a prospective, randomized, double-blind, controlled trial including 117 consecutive patients with alcohol dependence, according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, entering an alcohol treatment program at both the Lausanne and Geneva university hospitals, Switzerland. Patients were randomized into 2 groups: (1) 56 were treated with oxazepam in response to the development of signs of alcohol withdrawal (symptom-triggered); and (2) 61 were treated with oxazepam every 6 hours with additional doses as needed (fixed-schedule). The administration of oxazepam in group 1 and additional oxazepam in group 2 was determined using a standardized measure of alcohol withdrawal. The main outcome measures were the total amount and duration of treatment with oxazepam, the incidence of complications, and the comfort level. RESULTS: A total of 22 patients (39%) in the symptom-triggered group were treated with oxazepam vs 100% in the fixed-schedule group (P<.001). The mean oxazepam dose administered in the symptom-triggered group was 37.5 mg compared with 231.4 mg in the fixed-schedule group (P<.001). The mean duration of oxazepam treatment was 20.0 hours in the symptom-triggered group vs 62.7 hours in the fixed-schedule group (P<.001). Withdrawal complications were limited to a single episode of seizures in the symptom-triggered group. There were no differences in the measures of comfort between the 2 groups. CONCLUSIONS: Symptom-triggered benzodiazepine treatment for alcohol withdrawal is safe, comfortable, and associated with a decrease in the quantity of medication and duration of treatment.
Resumo:
The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10-12% increase in the number of IR examinations every year (UNSCEAR, 2010). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed.The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses.
Resumo:
LRH and its agonists have been shown to exert both stimulatory and inhibitory effects on testicular function. In the present study, the dose and length of treatment were tested to determine the appearance of the stimulatory and inhibitory effects of LRH agonist on testicular axis including the three levels. Two doses of an agonist of LRH, 40 and 100 ng/100 g body weight (buserelin, 'agonist'), were administered daily for 1 to 15 days to adult male rats. Control rats received the vehicle only. On day 1, 2, 4, 8 and 15 of treatment, the pituitary, testicular and peripheral levels (weight of accessory sex organs and androgen receptors in ventral prostate) were tested 6 h after the last injection. For the 15 days of treatment with both doses, a stimulatory effect of the 'agonist' was observed on LH and FSH release. A short exposure (1-2 days) to the low dose of the 'agonist' had a stimulatory effect on the density of LH/hCG testicular receptors (326 +/- 49 vs control 185 +/- 21 fmol/mg protein, mean +/- SEM), on the weights of seminal vesicles and ventral prostate and exposure to both doses led to high plasma testosterone levels (13.8 +/- 0.5 and 13.7 +/- 0.7 ng/ml, respectively, vs control 2.6 +/- 0.3 ng/ml), and to an increased density of nuclear androgen receptors in the ventral prostate (142 +/- 9 and 144 +/- 15 fmol/mg protein respectively vs control 97 +/- 12 fmol/mg protein).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
The blood pressure, heart rate and humoral responses to single intravenous doses of the angiotensin converting enzyme inhibitor captopril were evaluated in 5 volunteers on a free salt intake. Each subject was given at one-week intervals a 1, 5 and 25 mg intravenous dose of captopril as well as the vehicle of captopril. The study was conducted in a single-blind fashion and the order of treatment phases was randomized. Captopril was found to inhibit the renin-angiotensin system in a dose-dependent fashion. A fall in circulating angiotensin II was observed with doses of 1 and 5 mg. Plasma angiotensin II was not detectable 15 min after the 25 mg dose. Acute inhibition of angiotensin converting enzyme with intravenous captopril had no effect on blood pressure and heart rate.
Resumo:
We evaluated the effectiveness of supplementation with high dose of oral vitamin D3 to correct vitamin D insufficiency. We have shown that one or two oral bolus of 300,000 IU of vitamin D3 can correct vitamin D insufficiency in 50% of patients and that the patients who benefited more from supplementation were those with the lowest baseline levels. INTRODUCTION: Adherence with daily oral supplements of vitamin D3 is suboptimal. We evaluated the effectiveness of a single high dose of oral vitamin D3 (300,000 IU) to correct vitamin D insufficiency in a rheumatologic population. METHODS: Over 1 month, 292 patients had levels of 25-OH vitamin D determined. Results were classified as: deficiency <10 ng/ml, insufficiency ≥10 to 30 ng/ml, and normal ≥30 ng/ml. We added a category using the IOM recommended cut-off of 20 ng/ml. Patients with deficient or normal levels were excluded, as well as patients already supplemented with vitamin D3. Selected patients (141) with vitamin D insufficiency (18.5 ng/ml (10.2-29.1) received a prescription for 300,000 IU of oral vitamin D3 and were asked to return after 3 (M3) and 6 months (M6). Patients still insufficient at M3 received a second prescription for 300,000 IU of oral vitamin D3. Relation between changes in 25-OH vitamin D between M3 and M0 and baseline values were assessed. RESULTS: Patients (124) had a blood test at M3. Two (2%) had deficiency (8.1 ng/ml (7.5-8.7)) and 50 (40%) normal results (36.7 ng/ml (30.5-5.5)). Seventy-two (58%) were insufficient (23.6 ng/ml (13.8-29.8)) and received a second prescription for 300,000 IU of oral vitamin D3. Of the 50/124 patients who had normal results at M3 and did not receive a second prescription, 36 (72%) had a test at M6. Seventeen (47%) had normal results (34.8 ng/ml (30.3-42.8)) and 19 (53%) were insufficient (25.6 ng/ml (15.2-29.9)). Of the 72/124 patients who receive a second prescription, 54 (75%) had a test at M6. Twenty-eight (52%) had insufficiency (23.2 ng/ml (12.8-28.7)) and 26 (48%) had normal results (33.8 ng/ml (30.0-43.7)). At M3, 84% patients achieved a 25-OH vitamin D level >20 ng/ml. The lowest the baseline value, the highest the change after 3 months (negative relation with a correlation coefficient r = -0.3, p = 0.0007). CONCLUSIONS: We have shown that one or two oral bolus of 300,000 IU of vitamin D3 can correct vitamin D insufficiency in 50% of patients.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.