18 resultados para control alternative
Resumo:
Pseudomonas fluorescens CHA0, an effective biological control agent of soilborne plant diseases, is naturally non-mucoid. We have isolated a highly mucoid Tn5 insertion mutant of strain CHA0. The mucoid phenotype was found to be due to the overproduction of exopolysaccharide (EPS), as a result of a mutation in the mucA gene. The wild-type mucA gene was cloned by a two-step, Tn5-dependent cloning procedure previously described and the deduced amino acid sequence showed 71% identity with MucA of P. aeruginosa, a negative regulator of the alternative sigma factor AlgU (=s22, sE). As in P. aeruginosa, mucA is preceded by the algU gene encoding s22 (91% identity at the amino acid sequence level). A mucA in-frame deletion mutant of CHA0 overproduced EPS and formed mucoid colonies, whereas an algU in-frame deletion mutant showed a non-mucoid phenotype. Pyoluteorin, an antibiotic produced by P. fluorescens, was found to be entrapped in EPS of a mucoid mutant. In natural soil, mucoidy negatively affected survival of the bacteria, suggesting that under these conditions the potential to produce abundant EPS does not confer a selective advantage on the bacteria.
Resumo:
Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.
Resumo:
In the last decade, an increasing number of patients over 75 years of age are starting renal replacement therapy. Frailty is highly prevalent in elderly patients with end-stage renal disease (ESRD) in the context of the increased prevalence of some ESRD-associated conditions: protein-energy wasting, inflammation, anaemia, acidosis or hormonal disturbances. There are currently no hard data to support guidance on the optimal duration of dialysis for frail/elderly ESRD patients. The current debate is not about starting dialysis or managing conservatory frail ESRD patients, but whether a more intensive regimen once dialysis is initiated (for whatever reasons and circumstances) would improve patients' outcome. The most important issue is that all studies performed with extended/alternative dialysis regimens do not specifically address this particular type of patients and therefore all the inferences are derived from the general ESRD population. Care planning should be responsive to end-of-life needs whatever the treatment modality. Care in this setting should focus on symptom control and quality of life rather than life extension. We conclude that, similar to the general dialysed population, extensive application of more intensive dialysis schedules is not based on solid evidence. However, after a thorough clinical evaluation, a limited period of a trial of intensive dialysis could be prescribed in more problematic patients.