287 resultados para average toxicity score


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trabecular bone score (TBS, Med-Imaps, Pessac, France) is an index of bone microarchitecture texture extracted from anteroposterior dual-energy X-ray absorptiometry images of the spine. Previous studies have documented the ability of TBS of the spine to differentiate between women with and without fractures among age- and areal bone mineral density (aBMD)-matched controls, as well as to predict future fractures. In this cross-sectional analysis of data collected from 3 geographically dispersed facilities in the United States, we investigated age-related changes in the microarchitecture of lumbar vertebrae as assessed by TBS in a cohort of non-Hispanic US white American women. All subjects were 30 yr of age and older and had an L1-L4aBMDZ-score within ±2 SD of the population mean. Individuals were excluded if they had fractures, were on any osteoporosis treatment, or had any illness that would be expected to impact bone metabolism. All data were extracted from Prodigy dual-energy X-ray absorptiometry devices (GE-Lunar, Madison, WI). Cross-calibrations between the 3 participating centers were performed for TBS and aBMD. aBMD and TBS were evaluated for spine L1-L4 but also for all other possible vertebral combinations. To validate the cohort, a comparison between the aBMD normative data of our cohort and US non-Hispanic white Lunar data provided by the manufacturer was performed. A database of 619 non-Hispanic US white women, ages 30-90 yr, was created. aBMD normative data obtained from this cohort were not statistically different from the non-Hispanic US white Lunar normative data provided by the manufacturer (p = 0.30). This outcome thereby indirectly validates our cohort. TBS values at L1-L4 were weakly inversely correlated with body mass index (r = -0.17) and weight (r = -0.16) and not correlated with height. TBS values for all lumbar vertebral combinations decreased significantly with age. There was a linear decrease of 16.0% (-2.47 T-score) in TBS at L1-L4 between 45 and 90 yr of age (vs. -2.34 for aBMD). Microarchitectural loss rate increased after age 65 by 50% (-0.004 to -0.006). Similar results were obtained for other combinations of lumbar vertebra. TBS, an index of bone microarchitectural texture, decreases with advancing age in non-Hispanic US white women. Little change in TBS is observed between ages 30 and 45. Thereafter, a progressive decrease is observed with advancing age. The changes we observed in these American women are similar to that previously reported for a French population of white women (r(2) > 0.99). This reference database will facilitate the use of TBS to assess bone microarchitectural deterioration in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Screening of peripheral atherosclerosis is increasingly used, but few trials have examined its clinical impact. We aimed to assess whether carotid plaque screening helps smokers to improve their health behaviors and cardiovascular risk factors. METHODS: We randomly assigned 536 smokers aged 40 to 70 years to carotid plaque ultrasonographic screening (US group) vs no screening (control group) in addition to individual counseling and nicotine replacement therapy for all participants. Smokers with at least 1 plaque received pictures of their plaques with a 7-minute structured explanation. The outcomes included biochemically validated smoking cessation at 12 months (primary outcome) and changes in cardiovascular risk factor levels and Framingham risk score. RESULTS: At baseline, participants (mean age, 51.1 years; 45.0% women) smoked an average of 20 cigarettes per day with a median duration of 32 years. The US group had a high prevalence of carotid plaques (57.9%). At 12 months, smoking cessation rates were high, but did not differ between the US and control groups (24.9% vs 22.1%; P = .45). In the US group, cessation rates did not differ according to the presence or absence of plaques. Control of cardiovascular risk factors (ie, blood pressure and low-density lipoprotein cholesterol and hemoglobin A(1c) levels in diabetic patients) and mean absolute risk change in Framingham risk score did not differ between the groups. The mean absolute risk change in Framingham risk score was +0.6 in the US group vs +0.3 in the control group (P = .56). CONCLUSION: In smokers, carotid plaque screening performed in addition to thorough smoking cessation counseling is not associated with increased rates of smoking cessation or control of cardiovascular risk factors. Trial Registration  clinicaltrials.gov Identifier: NCT00548665.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at identifying clinical factors for predicting hematologic toxicity after radioimmunotherapy with (90)Y-ibritumomab tiuxetan or (131)I-tositumomab in clinical practice. Hematologic data were available from 14 non-Hodgkin lymphoma patients treated with (90)Y-ibritumomab tiuxetan and 18 who received (131)I-tositumomab. The percentage baseline at nadir and 4 wk post nadir and the time to nadir were selected as the toxicity indicators for both platelets and neutrophils. Multiple linear regression analysis was performed to identify significant predictors (P < 0.05) of each indicator. For both platelets and neutrophils, pooled and separate analyses of (90)Y-ibritumomab tiuxetan and (131)I-tositumomab data yielded the time elapsed since the last chemotherapy as the only significant predictor of the percentage baseline at nadir. The extent of bone marrow involvement was not a significant factor in this study, possibly because of the short time elapsed since the last chemotherapy of the 7 patients with bone marrow involvement. Because both treatments were designed to deliver a comparable bone marrow dose, this factor also was not significant. None of the 14 factors considered was predictive of the time to nadir. The R(2) value for the model predicting percentage baseline at nadir was 0.60 for platelets and 0.40 for neutrophils. This model predicted the platelet and neutrophil toxicity grade to within ±1 for 28 and 30 of the 32 patients, respectively. For the 7 patients predicted with grade I thrombocytopenia, 6 of whom had actual grade I-II, dosing might be increased to improve treatment efficacy. The elapsed time since the last chemotherapy can be used to predict hematologic toxicity and customize the current dosing method in radioimmunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aims: Cognitive dysfunction after medical treatment is increasingly being recognized. Studies on this topic require repeated cognitive testing within a short time. However, with repeated testing, practice effects must be expected. We quantified practice effects in a demographically corrected summary score of a neuropsychological test battery repeatedly administered to healthy elderly volunteers. Methods: The Consortium to Establish a Registry for Alzheimer's Disease (CERAD) Neuropsychological Assessment Battery (for which a demographically corrected summary score was developed), phonemic fluency tests, and trail-making tests were administered in healthy volunteers aged 65 years or older on days 0, 7, and 90. This battery allows calculation of a demographically adjusted continuous summary score. Results: Significant practice effects were observed in the CERAD total score and in the word list (learning and recall) subtest. Based on these volunteer data, we developed a threshold for diagnosis of postoperative cognitive dysfunction (POCD) with the CERAD total score. Conclusion: Practice effects with repeated administration of neuropsychological tests must be accounted for in the interpretation of such tests. Ignoring practice effects may lead to an underestimation of POCD. The usefulness of the proposed demographically adjusted continuous score for cognitive function will have to be tested prospectively in patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As most metabolic studies are conducted in male animals, understanding the sex specificity of the underlying molecular pathways has been broadly neglected; for example, whether PPARs elicit sex-dependent responses has not been determined. Here we show that in mice, PPARalpha has broad female-dependent repressive actions on hepatic genes involved in steroid metabolism and immunity. In male mice, this effect was reproduced by the administration of a synthetic PPARalpha ligand. Using the steroid oxysterol 7alpha-hydroxylase cytochrome P4507b1 (Cyp7b1) gene as a model, we elucidated the molecular mechanism of this sex-specific PPARalpha-dependent repression. Initial sumoylation of the ligand-binding domain of PPARalpha triggered the interaction of PPARalpha with GA-binding protein alpha (GABPalpha) bound to the target Cyp7b1 promoter. Histone deacetylase and DNA and histone methylases were then recruited, and the adjacent Sp1-binding site and histones were methylated. These events resulted in loss of Sp1-stimulated expression and thus downregulation of Cyp7b1. Physiologically, this repression conferred on female mice protection against estrogen-induced intrahepatic cholestasis, the most common hepatic disease during pregnancy, suggesting a therapeutic target for prevention of this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: School-based intervention studies promoting a healthy lifestyle have shown favorable immediate health effects. However, there is a striking paucity on long-term follow-ups. The aim of this study was therefore to assess the 3 yr-follow-up of a cluster-randomized controlled school-based physical activity program over nine month with beneficial immediate effects on body fat, aerobic fitness and physical activity. METHODS AND FINDINGS: Initially, 28 classes from 15 elementary schools in Switzerland were grouped into an intervention (16 classes from 9 schools, n = 297 children) and a control arm (12 classes from 6 schools, n = 205 children) after stratification for grade (1st and 5th graders). Three years after the end of the multi-component physical activity program of nine months including daily physical education (i.e. two additional lessons per week on top of three regular lessons), short physical activity breaks during academic lessons, and daily physical activity homework, 289 (58%) participated in the follow-up. Primary outcome measures included body fat (sum of four skinfolds), aerobic fitness (shuttle run test), physical activity (accelerometry), and quality of life (questionnaires). After adjustment for grade, gender, baseline value and clustering within classes, children in the intervention arm compared with controls had a significantly higher average level of aerobic fitness at follow-up (0.373 z-score units [95%-CI: 0.157 to 0.59, p = 0.001] corresponding to a shift from the 50th to the 65th percentile between baseline and follow-up), while the immediate beneficial effects on the other primary outcomes were not sustained. CONCLUSIONS: Apart from aerobic fitness, beneficial effects seen after one year were not maintained when the intervention was stopped. A continuous intervention seems necessary to maintain overall beneficial health effects as reached at the end of the intervention. TRIAL REGISTRATION: ControlledTrials.com ISRCTN15360785.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the extent of quality of life (QoL) associated adverse events (AEs) following PRECISION TACE with DC Bead compared with conventional transarterial chemoembolisation (cTACE). Methods and Materials: 201 intermediate HCC patients were treated with DC Bead (PRECISION TACE) or conventional TACE (cTACE) with doxorubicin in the PRECISION V clinical study. 93 patients were treated with DC Bead and 108 Patients with cTACE every 2 months and followed up for 6 months. AEs were classified according to the South West Oncology Group criteria. QoL associated AEs were defined as alopecia, constipation, nausea, vomiting, pyrexia, chills, asthenia, fatigue, and headache. Results: The biggest difference in QoL associated AEs was for alopecia: 2 patients (2.2%) for DC-Bead versus 21 patients (19.4%) for cTACE. For other clinical symptoms, constipation (n=10; 10.8% vs. n=13; 12%), vomiting (n=10; 10.8% vs. n=14; 13.0%), pyrexia (n=16; 17.2% vs. n=26; 24.1%), chills (n=1; 1.1% vs. n=5; 4.6%), and headache (n=2; 2.2% vs. n=8; 7.4%) showed lower incidence in the DC Bead group versus cTACE. Nausea, n= 15; 13.9% (n=15; 16.1%) and fatigue, n=6; 5.6% (n=13; 14.0%) were lower for cTACE. Total dose of doxorubicin was on average 35% higher in the DC Bead group. Conclusion: Although patients in the DC Bead group received a higher doxorubicin dose, less QoL associated AEs were reported for this group. Alopecia, the most obvious outward sign of toxicity, was only reported in a tenth of DC Bead patients. Thus, PRECISION TACE with DC Bead improves quality of life associated adverse events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MOTIVATION: Microarray results accumulated in public repositories are widely reused in meta-analytical studies and secondary databases. The quality of the data obtained with this technology varies from experiment to experiment, and an efficient method for quality assessment is necessary to ensure their reliability. RESULTS: The lack of a good benchmark has hampered evaluation of existing methods for quality control. In this study, we propose a new independent quality metric that is based on evolutionary conservation of expression profiles. We show, using 11 large organ-specific datasets, that IQRray, a new quality metrics developed by us, exhibits the highest correlation with this reference metric, among 14 metrics tested. IQRray outperforms other methods in identification of poor quality arrays in datasets composed of arrays from many independent experiments. In contrast, the performance of methods designed for detecting outliers in a single experiment like Normalized Unscaled Standard Error and Relative Log Expression was low because of the inability of these methods to detect datasets containing only low-quality arrays and because the scores cannot be directly compared between experiments. AVAILABILITY AND IMPLEMENTATION: The R implementation of IQRray is available at: ftp://lausanne.isb-sib.ch/pub/databases/Bgee/general/IQRray.R. CONTACT: Marta.Rosikiewicz@unil.ch SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This guide introduces Data Envelopment Analysis (DEA), a performance measurement technique, in such a way as to be appropriate to decision makers with little or no background in economics and operational research. The use of mathematics is kept to a minimum. This guide therefore adopts a strong practical approach in order to allow decision makers to conduct their own efficiency analysis and to easily interpret results. DEA helps decision makers for the following reasons: - By calculating an efficiency score, it indicates if a firm is efficient or has capacity for improvement. - By setting target values for input and output, it calculates how much input must be decreased or output increased in order to become efficient. - By identifying the nature of returns to scale, it indicates if a firm has to decrease or increase its scale (or size) in order to minimize the average cost. - By identifying a set of benchmarks, it specifies which other firms' processes need to be analysed in order to improve its own practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We analysed 5-year treatment with agalsidase alfa enzyme replacement therapy in patients with Fabry's disease who were enrolled in the Fabry Outcome Survey observational database (FOS). METHODS: Baseline and 5-year data were available for up to 181 adults (126 men) in FOS. Serial data for cardiac mass and function, renal function, pain, and quality of life were assessed. Safety and sensitivity analyses were done in patients with baseline and at least one relevant follow-up measurement during the 5 years (n=555 and n=475, respectively). FINDINGS: In patients with baseline cardiac hypertrophy, treatment resulted in a sustained reduction in left ventricular mass (LVM) index after 5 years (from 71.4 [SD 22.5] g/m(2.7) to 64.1 [18.7] g/m(2.7), p=0.0111) and a significant increase in midwall fractional shortening (MFS) from 14.3% (2.3) to 16.0% (3.8) after 3 years (p=0.02). In patients without baseline hypertrophy, LVM index and MFS remained stable. Mean yearly fall in estimated glomerular filtration rate versus baseline after 5 years of enzyme replacement therapy was -3.17 mL/min per 1.73 m(2) for men and -0.89 mL/min per 1.73 m(2) for women. Average pain, measured by Brief Pain Inventory score, improved significantly, from 3.7 (2.3) at baseline to 2.5 (2.4) after 5 years (p=0.0023). Quality of life, measured by deviation scores from normal EuroQol values, improved significantly, from -0.24 (0.3) at baseline to -0.17 (0.3) after 5 years (p=0.0483). Findings were confirmed by sensitivity analysis. No unexpected safety concerns were identified. INTERPRETATION: By comparison with historical natural history data for patients with Fabry's disease who were not treated with enzyme replacement therapy, long-term treatment with agalsidase alfa leads to substantial and sustained clinical benefits. FUNDING: Shire Human Genetic Therapies AB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess reproducibility and feasibility of amusculoskeletal ultrasound (US) score for rheumatoid arthritis amongrheumatologist with diverse expertise in US, working in private orhospital practice.Methods: The Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a semi-quantitative score for RA usingOMERACT criteria for synovitis and erosion. The score was taught torheumatologists trained in US through two workshops. Subsequently,they were encouraged to practice in their office. For the study, we used6 US machines of different quality, each with a different patient.19 readers randomly selected among rheumatologists who haveattended both workshops, were asked to score anonymously at leastone patient. To assess whether some factors influence the score, weasked each reader to answer questionnaire describing his experiencewith US.Results: 19 rheumatologists have performed 29 scans, each patienthaving been evaluated by 4 to 6 readers. Median time for examcompletion was 20 minutes (range 15 to 60 mn). 53% ofrheumatologists work in private practice. Graph 1 show the global greyscale score for each patient. Weighted kappa was calculated for eachpair of reader using stata11. Almost all kappa of poor agreement wereobtained with a low quality device or by an assessor who havepreviously performed less than 5 scores himself.Conclusions: This is the first study to show an US score for RAfeasible by rheumatologists with diverse expertise in US both in privateand hospital practice. Reproducibility seemed to be influenced by thequality of device and previous experience with the score.