36 resultados para air thickness, axial length, Lenstar, partial coherence interferometry, refractive index


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although exposure to secondhand smoke (SHS) is reportedly high in prison, few studies have measured this in the prison environment, and none have done so in Europe. We measured two indicators of SHS exposure (particulate matter PM10 and nicotine) in fixed locations before (2009) and after (2010) introduction of a partial smoking ban in a Swiss prison. Access to smoking cessation support was available to detainees throughout the study. Objectives To measure SHS before and after the introduction of a partial smoking ban. Methods Assessment of particulate matter PM10 (suspended microparticles of 10 μm) and nicotine in ambient air, collected by real-time aerosol monitor and nicotine monitoring devices. Results The authors observed a significant improvement of nicotine concentrations in the air after the introduction of the smoking ban (before: 7.0 μg/m(3), after: 2.1 μg/m(3), difference 4.9 μg/m(3), 95% CI for difference: 0.52 to 9.8, p=0.03) but not in particulate matter PM10 (before: 0.11 mg/m(3), after: 0.06 mg/m(3), difference 0.06 mg/m(3), 95% CI for difference of means: -0.07 to 0.19, p=0.30). Conclusions The partial smoking ban was followed by a decrease in nicotine concentrations in ambient air. These improvements can be attributed to the introduction of the smoking ban since no other policy change occurred during this period. Although this shows that concentrations of SHS decreased significantly, protection was still incomplete and further action is necessary to improve indoor air quality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This study investigated maximal cardiometabolic response while running in a lower body positive pressure treadmill (antigravity treadmill (AG)), which reduces body weight (BW) and impact. The AG is used in rehabilitation of injuries but could have potential for high-speed running, if workload is maximally elevated. METHODS: Fourteen trained (nine male) runners (age 27 ± 5 yr; 10-km personal best, 38.1 ± 1.1 min) completed a treadmill incremental test (CON) to measure aerobic capacity and heart rate (V&#729;O2max and HRmax). They completed four identical tests (48 h apart, randomized order) on the AG at BW of 100%, 95%, 90%, and 85% (AG100 to AG85). Stride length and rate were measured at peak velocities (Vpeak). RESULTS: V&#729;O2max (mL·kg·min) was similar across all conditions (men: CON = 66.6 (3.0), AG100 = 65.6 (3.8), AG95 = 65.0 (5.4), AG90 = 65.6 (4.5), and AG85 = 65.0 (4.8); women: CON = 63.0 (4.6), AG100 = 61.4 (4.3), AG95 = 60.7 (4.8), AG90 = 61.4 (3.3), and AG85 = 62.8 (3.9)). Similar results were found for HRmax, except for AG85 in men and AG100 and AG90 in women, which were lower than CON. Vpeak (km·h) in men was 19.7 (0.9) in CON, which was lower than every other condition: AG100 = 21.0 (1.9) (P < 0.05), AG95 = 21.4 (1.8) (P < 0.01), AG90 = 22.3 (2.1) (P < 0.01), and AG85 = 22.6 (1.6) (P < 0.001). In women, Vpeak (km·h) was similar between CON (17.8 (1.1) ) and AG100 (19.3 (1.0)) but higher at AG95 = 19.5 (0.4) (P < 0.05), AG90 = 19.5 (0.8) (P < 0.05), and AG85 = 21.2 (0.9) (P < 0.01). CONCLUSIONS: The AG can be used at maximal exercise intensities at BW of 85% to 95%, reaching faster running speeds than normally feasible. The AG could be used for overspeed running programs at the highest metabolic response levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography of the wrist with regard to joint space width and amount of contrast material between the opposing cartilage surfaces. MATERIALS AND METHODS: Fifteen consecutive patients (12 male, mean age 38.1 years) were included in this Institutional Review Board-approved prospective study. Three-compartment wrist MR arthrographies were performed between October and December 2009 on a 3 T unit using a fat-suppressed T1-weighted isotropic high-resolution volumetric interpolated breathhold examination (VIBE) sequence in the coronal plane, with and without axial traction (3 kg). Two radiologists measured radiocarpal (radioscaphoid, radiolunate) and midcarpal (lunocapitate, hamatolunate) joint space widths, with and without traction, and assessed the amount of contrast material between the opposing cartilage surfaces using a three-point scale: 0 = absence, 1 = partial, 2 = complete. RESULTS: With traction, joint space width increased significantly at the radioscaphoid (Delta = 0.78 mm, P &lt; 0.01), radiolunate (Delta = 0.18 mm, P &lt; 0.01), and lunocapitate (Delta = 0.45 mm, P &lt; 0.01) spaces, and both observers detected significantly more contrast material between the cartilage surfaces. At the hamatolunate space, the differences in joint space width (Delta = 0.14 mm, P = 0.54) and amount of contrast material were not significant. CONCLUSION: Direct wrist MR arthrography with axial traction of 3 kg increases joint space width at the radiocarpal and lunocapitate spaces, and prompts better coverage of the articular cartilage by the contrast material. J. Magn. Reson. Imaging 2011;. (c) 2011 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Axial deflection of DNA molecules in solution results from thermal motion and intrinsic curvature related to the DNA sequence. In order to measure directly the contribution of thermal motion we constructed intrinsically straight DNA molecules and measured their persistence length by cryo-electron microscopy. The persistence length of such intrinsically straight DNA molecules suspended in thin layers of cryo-vitrified solutions is about 80 nm. In order to test our experimental approach, we measured the apparent persistence length of DNA molecules with natural "random" sequences. The result of about 45 nm is consistent with the generally accepted value of the apparent persistence length of natural DNA sequences. By comparing the apparent persistence length to intrinsically straight DNA with that of natural DNA, it is possible to determine both the dynamic and the static contributions to the apparent persistence length.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to assess the validity of the weight per square of length ratio as an index of adiposity during the neonatal period, 37 premature infants (gestational age, mean +/- SD, = 31.5 +/- 1.1 weeks, birthweight, mean +/- SD, = 1.448 +/- 147 g) were studied for weight, length and skinfold thickness at 5 sites (biceps, triceps, subscapular, suprailiac and quadriceps) during their stay in the Neonatal Unit of the University Hospital in Lausanne. The results show a significant correlation between the adiposity index and the sum of 5 skinfold thickness sites in premature infants. The adiposity index gives a fair estimate of the body fat mass during the postnatal growth in premature infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent research, both soil (root-zone) and air temperature have been used as predictors for the treeline position worldwide. In this study, we intended to (a) test the proposed temperature limitation at the treeline, and (b) investigate effects of season length for both heat sum and mean temperature variables in the Swiss Alps. As soil temperature data are available for a limited number of sites only, we developed an air-to-soil transfer model (ASTRAMO). The air-to-soil transfer model predicts daily mean root-zone temperatures (10cm below the surface) at the treeline exclusively from daily mean air temperatures. The model using calibrated air and root-zone temperature measurements at nine treeline sites in the Swiss Alps incorporates time lags to account for the damping effect between air and soil temperatures as well as the temporal autocorrelations typical for such chronological data sets. Based on the measured and modeled root-zone temperatures we analyzed. the suitability of the thermal treeline indicators seasonal mean and degree-days to describe the Alpine treeline position. The root-zone indicators were then compared to the respective indicators based on measured air temperatures, with all indicators calculated for two different indicator period lengths. For both temperature types (root-zone and air) and both indicator periods, seasonal mean temperature was the indicator with the lowest variation across all treeline sites. The resulting indicator values were 7.0 degrees C +/- 0.4 SD (short indicator period), respectively 7.1 degrees C +/- 0.5 SD (long indicator period) for root-zone temperature, and 8.0 degrees C +/- 0.6 SD (short indicator period), respectively 8.8 degrees C +/- 0.8 SD (long indicator period) for air temperature. Generally, a higher variation was found for all air based treeline indicators when compared to the root-zone temperature indicators. Despite this, we showed that treeline indicators calculated from both air and root-zone temperatures can be used to describe the Alpine treeline position.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. MATERIALS AND METHODS: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. RESULTS: Under traction, the subacromial (&#916; = 2.0 mm, P = 0.0003), superior (&#916; = 0.7 mm, P = 0.0001) and inferior (&#916; = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. CONCLUSION: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:1228-1233. © 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine whether the need for retreatment after an initial phase of 3 monthly intravitreal injections of ranibizumab shows an intra-individual regular rhythm and to what degree it varies between different patients. Methods: Prospective study with 42 patients with exudative AMD, treatment naïve. Loading dose of 3 monthly doses of ranibizumab (0,5 mg), followed by a 12 months pro re nata (PRN) regimen according to early exudative signs on HD-OCT Cirrus, Zeiss. The follow-up visits were intensified (week 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, etc after each injection) in order to detect recurrences early, and injection followed within 3 days in cases of subretinal fluid, cysts, or central thickness increase of&gt;50microns. Intervals were calculated between injections for the 12 month follow-up with PRN treatment. Variability was expressed as standard deviation (SD). Results: Visual acuity (VA) improved from a mean ETDRS score of 61.6 (SD 10.8) at baseline to 68.0 (SD 10.2) at month 3 and to 74.7(SD 9.0) at month 12. The 15 patients who have already completed the study showed maintenance of the VA improvement. Central foveal thickness improved from a mean value of 366 microns (baseline) to 253 microns (month 3), well maintained thereafter. Mean number of injections was 8.8 (SD 3.5,range 0-12) per 12 months of follow-up (after 3 doses), with mean individual treatment-recurrence (TR) intervals ranging from 28-&gt;365 days (mean 58). Intraindividual variability of TR intervals (SD) was 7.1 days as a mean value (range 1.7¡V22.6). It ranged within 20% of the mean intra-individual interval for 30 (91%) and within 15% for 21 patients (64%). The first interval was within 1 week of the mean intra-individual interval in 64% and within 2 weeks in 89% of patients. Conclusions: The majority of AMD patients showed a relatively stable rhythm for PRN injections of ranibizumab after initial loading phase, associated with excellent functional/anatomical results. The initial interval last loading dose-first recurrence may have a predictive value for further need of treatment, potentially facilitating follow-up and patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to determine the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography examination of the knee in terms of joint space width and amount of contrast material between the cartilage surfaces. Direct knee MR arthrography was performed in 11 patients on a 3-T MR imaging unit using a T1-weighted isotropic gradient echo sequence in a coronal plane with and without axial traction of 15 kg. Joint space widths were measured at the level of the medial and the lateral femorotibial joint with and without traction. The amount of contrast material in the medial and lateral femorotibial joint was assessed independently by two musculoskeletal radiologists in a semiquantitative manner using three grades ('absence of surface visualization, 'partial surface visualization or 'complete surface visualization'). With traction, joint space width increased significantly at the lateral femorotibial compartment (mean = 0.55 mm, p = 0.0105) and at the medial femorotibial compartment (mean = 0.4 mm, p = 0.0124). There was a trend towards an increased amount of contrast material in the femorotibial compartment with axial traction. Direct MR arthrography of the knee with axial traction showed a slight and significant increase of the width of the femorotibial compartment with a trend towards more contrast material between the articular cartilage surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE:To determine whether the need for retreatment after an initial loading phase of 3 monthly intravitreal injections of ranibizumab shows an intra-individual regular rhythm and to what degree it varies between different patients.SETTING:Prospective mono-centre cohort study.METHODS:Prospective study with 42 patients with exudative age-related macular degeneration (AMD), treatment na?ve, giving informed consent. Loading dose of 3 monthly doses of ranibizumab (0,5mg), followed by a 12 months pro re nata (PRN) regimen according to early exudative signs on spectral domain optical coherence tomography (HD-OCT Cirrus Zeiss?, cube 512x126). The follow-up visits were intensified (week 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, 24, etc after each injection) in order to detect exudative recurrences early, and injection followed within 3 days in cases of subretinal fluid, or intraretinal cysts, or central thickness increase of &gt;50?m. Intervals were calculated between injections and the following recurrence was calculated for the 12 month follow-up with PRN treatment. Variability was expressed as standard deviation (SD). RESULTS Visual acuity (VA) improved from a mean ETDRS letter score of 61.6 (SD 10.8) at baseline to 68.0 (SD 10.2, +6.4 letters) at month 3 and increased further to 74.7 (SD 9.0, +13.1 letters from baseline) at month 12. The 15 patients who have completed the study by October 2010 showed maintenance of the VA improvement. Retinal thickness of the central foveal subfield improved from a mean value of 366?m(baseline) to 253?m(month 3), well maintained thereafter. Mean number of injections was 8.8 (SD 3.5) per 12 months of follow-up (after 3 loading doses), ranging from 0 to 12, with mean individual treatment-recurrence intervals ranging from 28 to &gt;365 days (mean 58 days). Intraindividual variability of treatment-recurrence intervals, measured as SD of the individual intervals, was 7.1days as a mean value(range 1.7 ? 22.6 days) for the 33 patients with more than 1 injection during follow-up. SD was higher for longer intervals of an individual patient. It ranged within 20% of the mean intra-individual interval for 30 patients(91%) and within 15% for 21 patients(64%). The first interval was within 1 week of the mean intra-individual interval in 64% of patients and within 2 weeks in 89% of patients.CONCLUSIONS:The majority of AMD patients showed a relatively stable rhythm for PRN injections of intravitreal ranibizumab after initial loading phase, associated with excellent functional and anatomical results. The initial interval between last loading dose and first recurrence may have a predictive value for further need of treatment, therefore potentially facilitating follow-up and patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A linkage disequilibrium between sexually selected and life history traits can be explained by three mutually non-exclusive mechanisms. Genes coding for two traits may be located close on the same chromosome, genes responsible for variation in one of the trait may pleiotropically alter the other, and non-random pairing with respect to two traits may generate a non-physical linkage disequilibrium between their genes. Knowledge of which of these three mechanisms is responsible for a covariation between two traits is of interest to understand why differently ornamented individuals differ in several phenotypic aspects. In Switzerland, barn owls Tyto alba mate randomly with respect to a colour polymorphism generating a large range of variants between reddish-brown and white, males being lighter coloured than females. Several studies have shown that plumage coloration is not neutral with respect to some life history components. To test whether coloration is genetically associated with body size, partial cross-fostering experiments were performed by exchanging some hatchlings between nests. These experiments showed that darker biological fathers produce longer-tailed offspring. This sex-specific pattern is consistent with the hypothesis of non-physical linkage disequilibrium. In line with this hypothesis, darker coloured males were mated with longer-tailed females, whereas female coloration was not associated with tail length of their mate. The finding that dark nestlings had a longer tail than their pale siblings also supports the physical linkage and pleiotropy hypotheses. Therefore, non-random pairing can generate or strengthen a genetic covariation between a secondary sexual character and a morphological trait.