169 resultados para Voltage measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The medulla oblongata (MO) contains a high density of glycinergic synapses and a particularly high concentration of glycine. The aims of this study were to measure directly in vivo the neurochemical profile, including glycine, in MO using a spin-echo-based (1)H MRS sequence at TE?=?2.8 ms and to compare it with three other brain regions (cortex, striatum and hippocampus) in the rat. Glycine was quantified in MO at TE?=?2.8 ms with a Cramér-Rao lower bound (CRLB) of approximately 5%. As a result of the relatively low level of glycine in the other three regions, the measurement of glycine was performed at TE?=?20 ms, which provides a favorable J-modulation of overlapping myo-inositol resonance. The other 14 metabolites composing the neurochemical profile were quantified in vivo in MO with CRLBs below 25%. Absolute concentrations of metabolites in MO, such as glutamate, glutamine, ?-aminobutyrate, taurine and glycine, were in the range of previous in vitro quantifications in tissue extracts. Compared with the other regions, MO had a three-fold higher glycine concentration, and was characterised by reduced (p?<?0.001) concentrations of glutamate (-50?±?4%), glutamine (-54?±?3%) and taurine (-78?±?3%). This study suggests that the functional specialisation of distinct brain regions is reflected in the neurochemical profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaders must scan the internal and external environment, chart strategic and task objectives, and provide performance feedback. These instrumental leadership (IL) functions go beyond the motivational and quid-pro quo leader behaviors that comprise the full-range-transformational, transactional, and laissez faire-leadership model. In four studies we examined the construct validity of IL. We found evidence for a four-factor IL model that was highly prototypical of good leadership. IL predicted top-level leader emergence controlling for the full-range factors, initiating structure, and consideration. It also explained unique variance in outcomes beyond the full-range factors; the effects of transformational leadership were vastly overstated when IL was omitted from the model. We discuss the importance of a "fuller full-range" leadership theory for theory and practice. We also showcase our methodological contributions regarding corrections for common method variance (i.e., endogeneity) bias using two-stage least squares (2SLS) regression and Monte Carlo split-sample designs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage-gated Na(+) channels (NaV channels) are specifically blocked by guanidinium toxins such as tetrodotoxin (TTX) and saxitoxin (STX) with nanomolar to micromolar affinity depending on key amino acid substitutions in the outer vestibule of the channel that vary with NaV gene isoforms. All NaV channels that have been studied exhibit a use-dependent enhancement of TTX/STX affinity when the channel is stimulated with brief repetitive voltage depolarizations from a hyperpolarized starting voltage. Two models have been proposed to explain the mechanism of TTX/STX use dependence: a conformational mechanism and a trapped ion mechanism. In this study, we used selectivity filter mutations (K1237R, K1237A, and K1237H) of the rat muscle NaV1.4 channel that are known to alter ionic selectivity and Ca(2+) permeability to test the trapped ion mechanism, which attributes use-dependent enhancement of toxin affinity to electrostatic repulsion between the bound toxin and Ca(2+) or Na(+) ions trapped inside the channel vestibule in the closed state. Our results indicate that TTX/STX use dependence is not relieved by mutations that enhance Ca(2+) permeability, suggesting that ion-toxin repulsion is not the primary factor that determines use dependence. Evidence now favors the idea that TTX/STX use dependence arises from conformational coupling of the voltage sensor domain or domains with residues in the toxin-binding site that are also involved in slow inactivation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le fonctionnement du système nerveux est sensible aux variations de la concentration d'acide. Une acidification des tissus peut se produire pendant une activité neuronale intense ou dans des situations physiopathologiques telles que l'inflammation ou les lésions cérébrales. Les canaux ioniques sensibles à l'acide (ASIC) sont activés par acidification et jouent un rôle important dans la détection des changements d'acide. Les ASICs contribuent à la dégénérescence neuronale après une lésion cérébrale, puisque leur inhibition limite la lésion neuronale. L'acidification induite par une inflammation du tissu nerveux conduit à des stimuli de douleur, qui sont détectés par ces canaux. En effet, les toxines qui bloquent spécifiquement les ASICs montrent des effets analgésiques dans des modèles animaux. La structure 3D d'ASIC peut être comparée à une main qui tient une boule entre son pouce et le doigt. Les différents domaines d'ASIC sont appelés doigt, pouce, jointure, boule-ß et paume. Les domaines transmembranaires représentent le poignet de cette main. Mon projet de thèse vise à décrire les mouvements survenant sur ce canal pendant son activité. A cet effet, j'ai utilisé une technique combinée qui permet la mesure des mouvements en temps réel durant l'activité du canal. J'ai montré les réarrangements des domaines extracellulaires pendant l'activité ASIC. Ces mouvements sont transmis au pore du canal, ou ils contrôlent sa fermeture et ouverture. La direction de ces mouvements a été évaluée pour les domaines doigt et jointure, et nous avons montré qu'ils s'éloignent de la boule-ß lors de l'acidification. J'ai également été en mesure de décrire les mouvements qui se produisent dans la poche acidique, une zone qui est considérée comme importante, car elle représente le site de liaison de certaines toxines de venin qui agissent sur les ASICs. J'ai ainsi pu montrer que les domaines doigt et le pouce qui forment la poche acidique se rapprochent l'un de l'autre pendant l'activation du canal. Ces résultats sont en accord avec des observations précédentes réalisées sur les ASICs par d'autres chercheurs. Enfin, cette analyse approfondie permet d'améliorer les connaissances sur le contrôle de l'activité ASIC; de plus, les mécanismes trouvés ici sont probablement partagés entre les canaux de la famille à laquelle appartiennent les ASICs. -- Les acid-sensing ion channels (ASICs) sont des canaux sodiques ouverts par les protons et principalement exprimés dans le système nerveux. Ils sont impliqués dans la détection des protons dans de nombreux états physiologiques et pathologiques comme l'ischémie et la perception de la douleur. La structure cristalline de l'isoforme ASIC1 de poulet a été déterminée dans l'état désensibilisé et ouvert. Les études fonctionnelles indiquent que la protonation des résidus clés dans la boucle extracellulaire déclenche des changements de conformation conduisant à l'ouverture du canal. Cependant, les mécanismes moléculaires qui relient la protonation à l'ouverture et la fermeture du canal n'ont pas encore été clarifiés. Dans cette étude, nous avons utilisé la voltage-clamp fluorimétrie (VCF) pour révéler les mouvements de l'activité associée qui se produisent dans les différents domaines de l'ASICla. Les fluorophores positionnés dans le pouce, la paume, le doigt, l'articulation et dans les domaines de l'entrée du pore extracellulaire ont montré des signaux de VCF liés à des changements de conformation au cours de l'activité du canal. La synchronisation des changements de fluorescence indique une séquence complexe de mouvements en fonction du pH. La cinétique de la fluorescence et des signaux de courant ont été comparés les uns aux autres afin de déterminer si le mouvement détecté par le signal de fluorescence correspond à une transition fonctionnelle définie du canal. Certains des résidus testés se sont révélés être étroitement liés à la désensibilisation du canal ou au rétablissement après la désensibilisation. En outre, nous avons trouvé qu'un tryptophane endogène de la boule-ß diminue le signal de fluorescence des sondes positionnées dans les domaines doigt et jointure. L'augmentation observée de ces signaux indique que ces domaines s'éloignent à une distance à partir de la boucle de la boule-ß. Sur la base de ce principe, nous avons généré des paires Trp-Cys « quencher», dans lequel le Cys est utilisé comme site d'ancrage pour attacher le fluorophore. Ensuite, nous avons évalué les changements de conformation qui se produisent au niveau de la poche acide, une zone importante pour la fonction et la régulation d'ASIC. Les signaux de fluorescence indiquent un mouvement de l'hélice supérieure du pouce vers le doigt et une rotation de la boule-ß dans le sens horaire. L'analyse de la cinétique indique que les mouvements des sous-domaines qui composent la poche acide se produisent pendant la désensibilisation du canal. Mon projet de doctorat représente la première analyse approfondie des changements conformationnels dépendants de l'activité des ASICs et fournit des informations sur les mécanismes de contrôle de l'activité du canal qui sont probablement partagés avec d'autres canaux proches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mutations in the SCN9A gene cause chronic pain and pain insensitivity syndromes. We aimed to study clinical, genetic, and electrophysiological features of paroxysmal extreme pain disorder (PEPD) caused by a novel SCN9A mutation. METHODS: Description of a 4-generation family suffering from PEPD with clinical, genetic and electrophysiological studies including patch clamp experiments assessing response to drug and temperature. RESULTS: The family was clinically comparable to those reported previously with the exception of a favorable effect of cold exposure and a lack of drug efficacy including with carbamazepine, a proposed treatment for PEPD. A novel p.L1612P mutation in the Nav1.7 voltage-gated sodium channel was found in the four affected family members tested. Electrophysiologically the mutation substantially depolarized the steady-state inactivation curve (V1/2 from -61.8 ± 4.5 mV to -30.9 ± 2.2 mV, n = 4 and 7, P < 0.001), significantly increased ramp current (from 1.8% to 3.4%, n = 10 and 12) and shortened recovery from inactivation (from 7.2 ± 5.6 ms to 2.2 ± 1.5 ms, n = 11 and 10). However, there was no persistent current. Cold exposure reduced peak current and prolonged recovery from inactivation in wild-type and mutated channels. Amitriptyline only slightly corrected the steady-state inactivation shift of the mutated channel, which is consistent with the lack of clinical benefit. CONCLUSIONS: The novel p.L1612P Nav1.7 mutation expands the PEPD spectrum with a unique combination of clinical symptoms and electrophysiological properties. Symptoms are partially responsive to temperature but not to drug therapy. In vitro trials of sodium channel blockers or temperature dependence might help predict treatment efficacy in PEPD.