43 resultados para Vacuum extraction
Resumo:
The aim of this study was to evaluate the forensic protocol recently developed by Qiagen for the QIAsymphony automated DNA extraction platform. Samples containing low amounts of DNA were specifically considered, since they represent the majority of samples processed in our laboratory. The analysis of simulated blood and saliva traces showed that the highest DNA yields were obtained with the maximal elution volume available for the forensic protocol, that is 200 ml. Resulting DNA extracts were too diluted for successful DNA profiling and required a concentration. This additional step is time consuming and potentially increases inversion and contamination risks. The 200 ml DNA extracts were concentrated to 25 ml, and the DNA recovery estimated with real-time PCR as well as with the percentage of SGM Plus alleles detected. Results using our manual protocol, based on the QIAamp DNA mini kit, and the automated protocol were comparable. Further tests will be conducted to determine more precisely DNA recovery, contamination risk and PCR inhibitors removal, once a definitive procedure, allowing the concentration of DNA extracts from low yield samples, will be available for the QIAsymphony.
Resumo:
Objectifs: Exposer une nouvelle technique permettant le retrait de ciment extra-vertebral par fuite accidentelle lors du retrait du matériel. Matériels et méthodes: Nous injectons le ciment lorsque sa densité est celle d'une pâte dentifrice pour éviter les passages vasculaires. Lorsque la vertèbre est parfaitement remplie,nous patientons quelques minutes pour éviter la fuite de ciment le long du trajet (environ 4 a 6 cc en moyenne par vertèbre sont injectés). Malgré ces précautions,une fuite de ciment peut survenir lors du retrait du trocart. Cette complication est rare lorsque l'on prend les précautions nécessaires. Cependant, si la pressionintra-vertébrale est importante, le ciment peut être aspiré en dehors de la vertèbre. Résultats: L'aiguille du trocart est retirée pour être remplacée par une pince d'endoscopie 13 gauges. Sous guidage scopique, l'extraction se fait sous contrôle continu ; lapince retirant la fuite de ciment. Conclusion: La connaissance de cette intervention peut être très utile pour les équipes de radiologie interventionnelle , d'orthopédie et de neurochirurgie réalisant desvertébroplasties, pouvant être confrontées à ce type de problèmes.
Resumo:
The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.
Endoscopic extraction of a prevertebral migrated guidewire after posterior cervical instrumentation.
Resumo:
Images of Spine Care
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Resumo:
The goal of this study was to compare the quantity and purity of DNA extracted from biological tracesusing the QIAsymphony robot with that of the manual QIAamp DNA mini kit currently in use in ourlaboratory. We found that the DNA yield of robot was 1.6-3.5 times lower than that of the manualprotocol. This resulted in a loss of 8% and 29% of the alleles correctly scored when analyzing 1/400 and 1/800 diluted saliva samples, respectively. Specific tests showed that the QIAsymphony was at least 2-16times more efficient at removing PCR inhibitors. The higher purity of the DNA may therefore partlycompensate for the lower DNA yield obtained. No case of cross-contamination was observed amongsamples. After purification with the robot, DNA extracts can be automatically transferred in 96-wellsplates, which is an ideal format for subsequent RT-qPCR quantification and DNA amplification. Lesshands-on time and reduced risk of operational errors represent additional advantages of the robotic platform.
Resumo:
Aim Background The expected benefit of transvaginal specimen extraction is reduced incision-related morbidity. Objectives A systematic review of transvaginal specimen extraction in colorectal surgery was carried out to assess this expectation. Method Search strategy The following keywords, in various combinations, were searched: NOSE (natural orifices specimen extraction), colorectal, colon surgery, transvaginal, right hemicolectomy, left hemicolectomy, low anterior resection, sigmoidectomy, ileocaecal resection, proctocolectomy, colon cancer, sigmoid diverticulitis and inflammatory bowel diseases. Selection criteria Selection criteria included large bowel resection with transvaginal specimen extraction, laparoscopic approach, human studies and English language. Exclusion criteria were experimental studies and laparotomic approach or local excision. All articles published up to February 2011 were included. Results Twenty-three articles (including a total of 130 patients) fulfilled the search criteria. The primary diagnosis was colorectal cancer in 51% (67) of patients, endometriosis in 46% (60) of patients and other conditions in the remaining patients. A concurrent gynaecological procedure was performed in 17% (22) of patients. One case of conversion to laparotomy was reported. In two patients, transvaginal extraction failed. In left- and right-sided resections, the rate of severe complications was 3.7% and 2%, respectively. Two significant complications, one of pelvic seroma and one of rectovaginal fistula, were likely to have been related to transvaginal extraction. The degree of follow up was specified in only one study. Harvested nodes and negative margins were adequate and reported in 70% of oncological cases. Conclusion Vaginal extraction of a colorectal surgery specimen shows potential benefit, particularly when associated with a gynaecological procedure. Data from prospective randomized trials are needed to support the routine use of this technique.
Resumo:
Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.
Resumo:
Capillary electrophoresis has drawn considerable attention in the past few years, particularly in the field of chiral separations because of its high separation efficiency. However, its routine use in therapeutic drug monitoring is hampered by its low sensitivity due to a short optical path. We have developed a capillary zone electrophoresis (CZE) method using 2mM of hydroxypropyl-β-cyclodextrin as a chiral selector, which allows base-to-base separation of the enantiomers of mianserin (MIA), desmethylmianserin (DMIA), and 8-hydroxymianserin (OHMIA). Through the use of an on-column sample concentration step after liquid-liquid extraction from plasma and through the presence of an internal standard, the quantitation limits were found to be 5 ng/mL for each enantiomer of MIA and DMIA and 15 ng/mL for each enantiomer of OHMIA. To our knowledge, this is the first published CE method that allows its use for therapeutic monitoring of antidepressants due to its sensitivity down to the low nanogram range. The variability of the assays, as assessed by the coefficients of variation (CV) measured at two concentrations for each substance, ranged from 2 to 14% for the intraday (eight replicates) and from 5 to 14% for the interday (eight replicates) experiments. The deviations from the theoretical concentrations, which represent the accuracy of the method, were all within 12.5%. A linear response was obtained for all compounds within the range of concentrations used for the calibration curves (10-150 ng/mL for each enantiomer of MIA and DMIA and 20-300 ng/mL for each enantiomer of OHMIA). Good correlations were calculated between [(R) + (S)]-MIA and DMIA concentrations measured in plasma samples of 20 patients by a nonchiral gas chromatography method and CZE, and between the (R)- and (S)-concentrations of MIA and DMIA measured in plasma samples of 37 patients by a previously described chiral high-performance liquid chromatography method and CZE. Finally, no interference was noted from more than 20 other psychotropic drugs. Thus, this method, which is both sensitive and selective, can be routinely used for therapeutic monitoring of the enantiomers of MIA and its metabolites. It could be very useful due to the demonstrated interindividual variability of the stereoselective metabolism of MIA.
Resumo:
Highly diverse radiolarian faunas of latest Maastrichtian to early Eocene age have been recovered from the low latitude realm in order to contribute to the clarification of radiolarian taxonomy, construct a zonation based on a discrete sequence of co-existence intervals of species ranging from the late Paleocene to early Eocene and to describe a rich low latitude latest Cretaceous to late Paleocene fauna. 225 samples of late Paleocene to early Eocene age have been collected from ODP Leg 171 B-Hole 1051 A (Blake Nose), DSDP Leg 43-Site 384 (Northwest Atlantic) and DSDP Leg 10-Sites 86, 94, 95, 96. Sequences consist of mainly pelagic oozes and chalks, with some clay and ash layers. A new imaging technique is devised to perform (in particular on topotypic material) both transmitted light microscopy and SEM imaging on individual radiolarian specimens. SEM precedes transmitted light imaging. Radiolarians are adhered to a cover slip (using nail varnish) which is secured to a stub using conductive levers. Specimens are then photographed in low vacuum (40-50Pa; 0.5mbar), which enables charge neutralization by ionized molecules of the chamber atmosphere. Thus gold coating is avoided and subsequently this allows transmitted light imaging to follow. The conductive levers are unscrewed and the cover slip is simply overturned and mounted with Canada balsam. In an attempt towards a post-Haeckelian classification, the initial spicule (Entactinaria), micro- or macrosphere (Spumellaria) and initial spicule and cephalis (Nassellaria) have been studied by slicing Entactinaria and Spumellaria, and by tilting Nassellaria in the SEM chamber. A new genus of the family Coccodiscidae is erected and Spongatractus HAECKEL is re-located to the subfamily Axopruinae. The biochronology has been carried out using the Unitary Association Method (Guex 1977, 1991). A database recording the occurrences of 112 species has been used to establish a succession of 22 Unitary Associations. Each association is correlated to chronostratigraphy via calcareous microfossils that were previously studied by other authors. The 22 UAs have been united into seven Unitary Associations Zones (UAZones) (JP10- JE4). The established zones permit to distinguish supplementary subdivisions within the existing zonation. The low-latitude Paleocene radiolarian zonation established by Sanfilippo and Nigrini (1998a) is incomplete due to the lack of radiolarian-bearing early Paleocene sediments. In order to contribute to the study of sparsely known low latitude early Paleocene faunas, 80 samples were taken from the highly siliceous Guayaquil Formation (Ecuador). The sequence consists of black cherts, shales, siliceous limestones and volcanic ash layers. The carbonate content increases up section. Age control is supplied by sporadic occurrences of silicified planktonic foraminifera casts. One Cretaceous zone and seven Paleocene zones have been identified. The existing zonation for the South Pacific can be applied to the early-early late Paleocene sequence, although certain marker species have significantly shorter ranges (notably Buryella foremanae and B. granulata). Despite missing marker species in the late Paleocene, faunal distribution correlates reasonably to the Low-Latitude zonation. An assemblage highly abundant in Lithomelissa, Lophophaena and Cycladophora in the upper RP6 zone (correlated by the presence of Pterocodon poculum, Circodiscus circularis, Pterocodon? sp. aff. P. tenellus and Stylotrochus nitidus) shows a close affinity to contemporaneous faunas reported from Site 1121, Campbell Plateau. Coupled with a high diatom abundance (notably Aulacodiscus spp. and Arachnoidiscus spp.), these faunas are interpreted as reflecting a period of enhanced biosiliceous productivity during the late Paleocene. The youngest sample is void of radiolarians, diatoms and sponge spicules yet contains many pyritized infaunal benthic foraminifera which are akin to the midway-type fauna. The presence of this fauna suggests deposition in a neritic environment. This is in contrast to the inferred bathyal slope depositional environment of the older Paleocene sediments and suggests a shoaling of the depositional environment which may be related to a coeval major accretionary event. RESUME DE LA THESE Des faunes de radiolaires de basses latitudes très diversifiées d'âge Maastrichtien terminal à Eocène inférieur, ont été étudiées afin de contribuer à la clarification de leur taxonomie, de construire une biozonation basée sur une séquence discrète d'intervalles de coexistence des espèces d'age Paléocène supérieur à Eocène inférieur et de décrire une riche faune de basse latitude allant du Crétacé terminal au Paléocène supérieur. L'étude de cette faune contribue particulièrement à la connaissance des insaisissables radiolaires de basses latitudes du Paléocène inférieur. 225 échantillons d'âge Paléocène supérieur à Eocène inférieur provenant des ODP Leg 171B-Site 1051A (Blake Nose), Leg DSDP 43-Site 384 (Atlantique Nord -Ouest) et des DSDP Leg 10 -Sites 86, 94, 95, 96, ont été étudiés. Ces séquences sont constituées principalement de « ooze » et de « chalks »pélagiques ainsi que de quelques niveaux de cendres et d'argiles. Une nouvelle technique d'imagerie a été conçue afin de pouvoir prendre conjointement des images en lumière transmise et au Microscope Electronique à Balayage (MEB) de spécimens individuels. Ceci à été particulièrement appliqué à l'étude des topotypes. L'imagerie MEB précède l'imagerie en lumière transmise. Les radiolaires sont collés sur une lame pour micropaléontologie (au moyen de vernis à ongles) qui est ensuite fixée à un porte-objet à l'aide de bras métalliques conducteurs. Les spécimens sont ensuite photographiés en vide partiel (40-50Pa; 0.5mbar), ce qui permet la neutralisation des charges électrostatiques dues à la présence de molécules ionisées dans l'atmosphère de la chambre d'observation. Ainsi la métallisation de l'échantillon avec de l'or n'est plus nécessaire et ceci permet l'observation ultérieure en lumière transmise. Les bras conducteurs sont ensuite dévissés et la lame est simplement retournée et immergée dans du baume du Canada. Dans une approche de classification post Haeckelienne, le spicule initial (Entactinaires), la micro- ou macro -sphère (Spumellaires) et le spicule initial et cephalis (Nassellaires) ont été étudiés. Ceci a nécessité le sectionnement d'Entactinaires et de Spumellaires, et de pivoter les Nassellaires dans la chambre d'observation du MEB. Un nouveau genre de la Famille des Coccodiscidae a été érigé et Spongatractus HAECKEL à été réassigné à la sous-famille des Axopruninae. L'analyse biostratigraphique à été effectuée à l'aide de la méthode des Associations Unitaires {Guex 1977, 1991). Une base de données enregistrant les présences de 112 espèces à été utilisée poux établir une succession de 22 Associations Unitaires. Chaque association est corrélée à la chronostratigraphie au moyen de microfossiles calcaires précédemment étudiés par d'autres auteurs. Les 22 UAs ont été combinées en sept Zones d'Associations Unitaires (UAZones) (JP10- JE4). Ces Zones permettent d'insérer des subdivisions supplémentaires dans la zonation actuelle. La zonation de basses latitudes du Paléocène établie par Sanfilippo et Nigrini (1998a) est incomplète due au manque de sédiments du Paléocène inférieur contenant des radiolaires. Afin de contribuer à l'étude des faunes peu connues des basses latitudes du Paléocène inférieur, 80 échantillons ont été prélevés d'une section siliceuse de la Formation de Guayaquil (Equateur). La séquence est composée de cherts noirs, de shales, de calcaires siliceux et de couches de cendres volcaniques. La fraction carbonatée augmente vers le haut de la section. Des contraintes chronologiques sont fournies par la présence sporadique de moules de foraminifères planctoniques. Une zone d'intervalles du Crétacé et sept du Paléocène ont été mises en évidence. Bien que certaines espèces marqueur ont des distributions remarquablement plus courtes (notamment Buryella foremanae et B. granulata), la zonation existante pour le Pacifique Sud est applicable à la séquence d'age Paléocène inférieure à Paléocène supérieur basal étudiée. Malgré l'absence d'espèces marqueur du Paléocène supérieur, la succession faunistique se corrèle raisonnablement avec la zonation pour les basses latitudes. Un assemblage contenant d'abondants représentant du genre Lithomelissa, Lophophaena et Cycladophora dans la zone RP6 (correlée par la présence de Pterocodon poculum, Circodiscus circularis, Pterocodon? sp. aff. P. tenellus et Stylotrochus nitidus) montre une grande similitude avec certaines faunes issues des hauts latitudes et d'age semblable décrites par Hollis (2002, Site 1121, Campbell Plateau). Ceci, en plus d'une abondance importante en diatomés (notamment Aulacodiscus spp. et Arachnoidiscus spp.) nous mènent à interpréter cette faune comme témoin d'un épisode de productivité biosiliceuse accrue dans le Paléocène supérieur. L'échantillon le plus jeune, dépourvu de radiolaires, de diatomés et de spicules d'éponge contient de nombreux foraminifères benthiques infaunaux pyritisés. Les espèces identifiées sont caractéristiques d'une faune de type midway. La présence de ces foraminifères suggère un environnement de type néritique. Ceci est en contraste avec l'environnement de pente bathyale caractérisent les sédiments sous-jacent. Cette séquence de diminution de la tranche d'eau peut être associée à un événement d'accrétion majeure. RESUME DE LA THESE (POUR LE GRAND PUBLIC) Les radiolaires constituent le groupe de plancton marin le plus divers et le plus largement répandu de l'enregistrement fossile. Un taux d'évolution rapide et une variation géographique considérable des populations font des radiolaires un outil de recherche sans égal pour la biostratigraphie et la paléocéanographie. Néanmoins, avant de pouvoir les utiliser comme outils de travail, il est essentiel d'établir une solide base taxonomique. L'étude des Radiolaires peut impliquer plusieurs techniques d'extraction, d'observation et d'imagerie qui sont dépendantes du degré d'altération diagénétique des spécimens. Le squelette initial, qu'il s'agisse d'un spicule initial (Entactinaria), d'une micro- ou macro -sphère (Spumellaria) ou d'un spicule initial et d'un cephalis (Nassellaria), est l'élément le plus constant au cours de l'évolution et devrait représenter le fondement de la systématique. Des échantillons provenant de carottes de basses latitudes du Deep Sea Drilling Project et de l' Ocean Drilling ont été étudiés. De nouvelles techniques d'imagerie et de sectionnement ont été développées sur des topotypes de radiolaires préservés en opale, dans le but d'étudier les caractéristiques de leur squelette initial qui n'étaient pas visibles dans leur illustration originale. Ceci aide entre autre à comparer des spécimens recristallisés en quartz, provenant de terrains accrétés, avec les holotypes en opale de la littérature. La distribution des espèces étudiés a fourni des données biostratigraphiques qui ont été compilées à l'aide de la méthode des Associations Unitaires (Guez 1977, 1991). Il s'agit d'un modèle mathématique déterministe conçu pour exploiter la totalité de l'assemblage plutôt que de se confiner à l'utilisation de taxons marqueurs individuels. Une séquence de 22 Associations Unitaires a été établie pour la période allant du Paléocène supérieur à l'Éocène inférieur. Chaque Association Unitaire a été corrélée à l'échelle de temps absolue à l'aide de microfossiles calcaires. Les 22 UAs ont été combinées en sept Zones d'Associations Unitaires (JP10- JE4). Ces Zones permettent d'insérer des subdivisions supplémentaires dans la zonation actuelle. Les radiolaires du Paléocène inférieur à moyen des basses latitudes sont rares. Les meilleures sections connues se trouvent dans les hautes latitudes (Nouvelle Zélande). Quelques assemblages épars ont été mentionnés par le passé en Californie, en Équateur et en Russie. Une séquence siliceuse de 190 mètres dans la Formation de Guayaquil (Équateur), s'étendant du Maastrichtien supérieur au Paléocène supérieur, a fourni des faunes relativement bien préservées. L'étude de ces faunes a permis de mettre en évidence la première séquence complète de radiolaires de basses latitudes dans le Paléocène inférieure. Huit zones allant du Crétacé terminal au Paléocène supérieur ont pu être appliqués et la présence de foraminifères planctoniques a fournie plusieurs points d'attache chronologiques. Dans le Paléocène supérieur, un riche assemblage contenant d'abondants diatomés et radiolaires ayant des similitudes faunistiques marquantes avec des assemblages de hautes latitudes de Nouvelle Zélande, témoigne d'un épisode de productivité biosiliceuse accrue pendant cette période. Étant donné que la pointe du continent sud-américain et l'Antarctique étaient plus proches au cours du Paléocène, ce phénomène peut être expliqué par le transport, le long de la côte ouest de l'Amérique du Sud, d'eaux riches en nutriments en provenance de l'Océan Antarctique. Suite à cet épisode, l'enregistrement en radiolaires est interrompu. Ceci peut être associé à des événements tectoniques régionaux qui ont eu pour effet de diminuer la tranche d'eau relative, rendant l'environnement plus favorable aux foraminifères benthiques qui sont abondamment présents dans l'échantillon le plus jeune de la séquence.