22 resultados para True Faith


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our work was to show how a chosen normal-isation strategy can affect the outcome of quantitative gene expression studies. As an example, we analysed the expression of three genes known to be upregulated under hypoxic conditions: HIF1A, VEGF and SLC2A1 (GLUT1). Raw RT-qPCR data were normalised using two different strategies: a straightforward normalisation against a single reference gene, GAPDH, using the 2(-ΔΔCt) algorithm and a more complex normalisation against a normalisation factor calculated from the quantitative raw data from four previously validated reference genes. We found that the two different normalisation strategies revealed contradicting results: normalising against a validated set of reference genes revealed an upregulation of the three genes of interest in three post-mortem tissue samples (cardiac muscle, skeletal muscle and brain) under hypoxic conditions. Interestingly, we found a statistically significant difference in the relative transcript abundance of VEGF in cardiac muscle between donors who died of asphyxia versus donors who died from cardiac death. Normalisation against GAPDH alone revealed no upregulation but, in some instances, a downregulation of the genes of interest. To further analyse this discrepancy, the stability of all reference genes used were reassessed and the very low expression stability of GAPDH was found to originate from the co-regulation of this gene under hypoxic conditions. We concluded that GAPDH is not a suitable reference gene for the quantitative analysis of gene expression in hypoxia and that validation of reference genes is a crucial step for generating biologically meaningful data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe two cases of true dorsalis pedis artery aneurysms in men referred for pulsatile mass of the dorsal part of the foot. Both aneurysms were resected and grafted with interposition of a short segment of saphenous vein. Histological analysis showed true aneurysm associated with atherosclerosis. To our knowledge, only 12 cases of true dorsalis pedis artery aneurysm have been reported previously. On the basis of our experience and after reviewing the literature, the management of this uncommon pathology was discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by x-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-venography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: A surgical gastrostomy is mandatory in cases where a PEG is not feasible. Various minimally invasive techniques have been described, but many involve unusable materials in small children and/or have risk of disunion. We describe a technique for true Stamm gastrostomy performed by laparoscopy (LSG) with a purse string suture and four points of attachment onto the wall. METHOD: We reviewed 20 children who underwent an LSG from 2010 to 2013. After incision of the skin at the location planned for the gastrostomy, using three 3-5mm ports the stomach is fixed to the wall by three suspension stitches, which are entered and then emerged subcutaneously. A fourth stitch of attachment is used to make an award on the stomach and tie around the gastrostomy tube. RESULTS: Mean age was 4.2years, with 70% aged <2years. All children were malnourished, most often severely. All but two underwent a concomitant fundoplication. Feeding through the gastrostomy started on D0 or D1. Total feeding by gastrostomy was achieved in a mean duration of 2.9day. Mean hospital stay was 4.5days. There was no perioperative complication. Mean follow-up was 14months. Once, the balloon was accidently deflated and reinflated in the wall leading to its necrosis. Five peristomial granulomas were noticed. It was always possible to replace the tube by a gastrostomy device at least 6weeks after surgery. CONCLUSION: This new technique for true Stamm gastrostomy by laparoscopy reproduces exactly the one done by laparotomy, without special equipment. It can be made since the neonatal period, in all the circumstances when a laparoscopy is possible.