Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0 degrees to 150 degrees of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90 degrees of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it. This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.
Resumo:
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.
Resumo:
HYPOTHESIS: The nonanatomical design of reverse shoulder prostheses induce medial displacement of the center of rotation, impingements and may reduce the mobility of the shoulder. The aim of this study is to test the hypothesis that during activities of daily living functional mobility of the shoulder can be restored by scapular compensation. MATERIAL AND METHODS: A numerical 3-dimensional model was developed to reproduce the movement of the scapula and humerus, during 4 activities of daily living measured experimentally. This hypothesis was tested in 4 configurations of the aequalis reverse prosthesis (standard 36-mm glenosphere, 42-mm glenosphere, lateralized 36-mm glenosphere, lateralized Bony Increased-Offset Reverse Shoulder Arthroplasty [BIO-RSA]), which were implanted in the virtual model. All impingement positions were evaluated, as the required scapular compensation to avoid impingements. RESULTS: With the 36-mm glenosphere, impingements occurred only for rest of hand to back-pocket positions. The 42-mm partly improved the mobility. The 2 lateralized glenospheres were free of impingement. When impingements occurred, the scapular compensation was less than 10°. CONCLUSION: Most reverse prostheses impingements reported in clinical and biomechanical studies can be avoided, either by scapular compensation or by a glenosphere lateralization. After reverse shoulder arthroplasty, a fraction of the mobility of the gleno-humeral is transferred to the scapulo-thoracic joint.
Resumo:
Total shoulder arthroplasty (TSA) is an accepted and most successfully used treatment for different shoulder pathologies. Different risk factors for the failure of the prosthesis are known. A pathological scapular orientation, observed in elderly people or in patients suffering from neuromuscular diseases, could be a cause of failure, which has not been investigated yet. To test this hypothesis, a numerical musculoskeletal model of the glenohumeral joint was used to compare two TSA cases: a reference normal case and a case with a pathological anterior tilt of the scapula. An active abduction of 150° was simulated. Joint force, contact pattern, polyethylene and cement stress were evaluated for both cases. The pathological tilt slightly increased the joint force and the contact pressure, but also shifted the contact pattern. This eccentric contact increased the stress level within the polyethylene of the glenoid component and within the surrounding cement layer. This adverse effect occurred mainly during the first 60° of abduction. Therefore, a pathological orientation of the scapula may increase the risk of a failure of the cement layer around the glenoid component. These preliminary numerical results should be confirmed by a clinical study.
Resumo:
Given the important role of the shoulder sensorimotor system in shoulder stability, its assessment appears of interest. Force platform monitoring of centre of pressure (CoP) in upper-limb weight-bearing positions is of interest as it allows integration of all aspects of shoulder sensorimotor control. This study aimed to determine the feasibility and reliability of shoulder sensorimotor control assessment by force platform. Forty-five healthy subjects performed two sessions of CoP measurement using Win-Posturo(®) Medicapteurs force platform in an upper-limb weight-bearing position with the lower limbs resting on a table to either the anterior superior iliac spines (P1) or upper patellar poles (P2). Four different conditions were tested in each position in random order: eyes open or eyes closed with trunk supported by both hands and eyes open with trunk supported on the dominant or non-dominant side. P1 reliability values were globally moderate to high for CoP length, CoP velocity and CoP standard deviation (SD), standard error of measurement ranged from 6·0% to 26·5%, except for CoP area. P2 reliability values were globally low and not clinically acceptable. Our results suggest that shoulder sensorimotor control assessment by force platform is feasible and has good reliability in upper-limb weight-bearing positions when the lower limbs are resting on a table to the anterior superior iliac spines. CoP length, CoP velocity and CoP SD velocity appear to be the most reliable variables.
Resumo:
Introduction: Several studies have reported significant alteration of the scapula-humeral rythm after total shoulder arthroplasty. However, the biomechanical and clinical effects, particularly on implants lifespan, are still unknown. The goal of this study was to evaluate the biomechanical consequences of an altered scapula-humeral rhythm. Methods: A numerical musculoskeletal model of the shoulder was used. The model included the scapula, the humerus and 6 scapulohumeral muscles: middle, anterior, and posterior deltoid, supraspinatus, subscapularis and infraspinatus combined with teres minor. Arm motion and joint stability were achieved by muscles. The reverse and anatomic Aequalis prostheses (Tornier Inc) were inserted. Two scapula-humeral rhythms were considered for each prosthesis: a normal 2:1 rhythm, and an altered 1:2 rhythm. For the 4 configurations, a movement of abduction in the scapular plane was simulated. The gleno-humeral force and contact pattern, but also the stress in the polyethylene and cement were evaluated. Results: With the anatomical prosthesis, the gleno-humeral force increased of 23% for the altered rhythm, with a more eccentric (posterior and superior) contact. The contact pressure, polyethylene stress, and cement stress increased respectively by 20%, 48% and 64%. With the reverse prosthesis, the gleno-humeral force increased of 11% for an altered rhythm. There was nearly no effect on the contact pattern on the polyethylene component surface. Conclusion: The present study showed that alteration oft the scapula-humeral rythm induced biomechanical consequences which could preclude the long term survival of the glenoid implant of anatomic prostheses. However,an altered scapula-humeral rhythm, even severe, should not be a contra indication for the use of a reverse prosthesis.
Resumo:
BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.
Resumo:
This study was conducted to analyze whether internal (IR) and external (ER) rotator shoulder muscles weakness and/or imbalance collected through a preseason assessment could be predictors of subsequent shoulder injury during a season in handball players. In preseason, 16 female elite handball players (HPG) and 14 healthy female nonathletes (CG) underwent isokinetic IR and ER strength test with use of a Con-Trex® dynamometer in a seated position with 45° shoulder abduction in scapular plane, at 60, 120 and 240°/s in concentric and at 60°/s in eccentric, for both sides. An imbalanced muscular strength profile was determined using -statistically selected cut-offs from CG values. For HPG, all newly incurred shoulder injuries were reported during the season. There were significant differences between HPG and CG only for dominant eccentric IR strength, ER/IR ratio at 240°/s and for IRecc/ERcon ratio. In HPG, IR and ER strength was higher, and ER/IR ratios lower for dominant than for nondominant side. The relative risk was 2.57 (95%CI: 1.60-3.54; P<0.05) if handball players had an imbalanced muscular strength profile. In youth female handball players IR and ER muscle strength increases on the dominant side without ER/IR imbalances; and higher injury risk was associated with imbalanced muscular strength profile.
Resumo:
Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.
Resumo:
BACKGROUND: Anatomical total shoulder arthroplasty (TSA) for glenohumeral osteoarthritis (OA) and severe posterior glenoid wear may entail early postoperative complications (recurrence of posterior subluxation, glenoid loosening). To avoid these mechanical problems, reverse shoulder arthroplasty (RSA) has recently been proposed, mainly for its intrinsic stability. Our purpose was to present the results of TSA and RSA in glenohumeral OA with posterior glenoid wear of at least 20°. HYPOTHESIS: By virtue of its constrained design, RSA could prevent recurrence of posterior subluxation and limit the occurrence of mechanical complications. MATERIALS AND METHODS: A consecutive series of 23 patients (27 shoulders) were treated for glenohumeral OA with total shoulder prostheses: 19 TSAs and 8 RSAs. Mean age was 70years (range, 47-85years), mean retroversion angle 28° (20°-50°) and mean subluxation index 74% (57-89%). Constant Score, Subjective Shoulder Value (SSV), QuickDASH and Simple Shoulder Test (SST) were measured, and radiological examinations were performed at a mean follow-up of 52months (24-95months). RESULTS: TSA and RSA patients respectively displayed Constant Scores of 65 and 65, SSV of 79% and 74%, QuickDASH of 16 and 27, and SST of 88 and 78. Two patients underwent surgical revision of TSA because of glenoid loosening; 52% of TSA patients presented complete radiolucent lines and 11% recurrence of posterior subluxation. CONCLUSION: Complications are frequently observed after shoulder arthroplasty for OA with severe glenoid retroversion. RSA could be an alternative to TSA for selected patients, independently of rotator cuff status. Studies on RSA in this specific indication with longer follow-up are now needed. LEVEL OF EVIDENCE: Level IV; retrospective case series.
Resumo:
PURPOSE: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. MATERIALS AND METHODS: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. RESULTS: Under traction, the subacromial (Δ = 2.0 mm, P = 0.0003), superior (Δ = 0.7 mm, P = 0.0001) and inferior (Δ = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. CONCLUSION: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:1228-1233. © 2012 Wiley Periodicals, Inc.
Resumo:
HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.