38 resultados para Techniques of data analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we discuss the use of digital data by the Swiss Federal Criminal Court in a recent case of attempted homicide. We use this case to examine drawbacks for the defense when the presentation of scientific evidence is partial, especially when the only perspective mentioned is that of the prosecution. We tackle this discussion at two distinct levels. First, we pursue an essentially non-technical presentation of the topic by drawing parallels between the court's summing up of the case and flawed patterns of reasoning commonly seen in other forensic disciplines, such as DNA and particle traces (e.g., gunshot residues). Then, we propose a formal analysis of the case, using elements of probability and graphical probability models, to justify our main claim that the partial presentation of digital evidence poses a risk to the administration of justice in that it keeps vital information from the defense. We will argue that such practice constitutes a violation of general principles of forensic interpretation as established by forensic science literature and current recommendations by forensic science interest groups (e.g., the European Network of Forensic Science Institutes). Finally, we posit that argument construction and analysis using formal methods can help replace digital evidence appropriately into context and thus support a sound evaluation of the evidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This letter describes a data telemetry biomedical experiment. An implant, consisting of a biometric data sensor, electronics, an antenna, and a biocompatible capsule, is described. All the elements were co-designed in order to maximize the transmission distance. The device was implanted in a pig for an in vivo experiment of temperature monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reconstructive surgery takes an important place in breast cancer treatment. Immediate breast reconstruction is performed during the same operation as mastectomy. It is contraindicated following radiotherapy. Reconstruction performed after mastectomy is called differed breast reconstruction. It is completed 6 months after chemotherapy and 1 year after radiotherapy. Prosthetic breast reconstruction is indicated when tissues are of good qualities and breast are small. Autologous reconstruction is performed in case of radiotherapy or large breast. After breast reconstruction, imperfections can be corrected with autologous fat injection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within the framework of a retrospective study of the incidence of hip fractures in the canton of Vaud (Switzerland), all cases of hip fracture occurring among the resident population in 1986 and treated in the hospitals of the canton were identified from among five different information sources. Relevant data were then extracted from the medical records. At least two sources of information were used to identify cases in each hospital, among them the statistics of the Swiss Hospital Association (VESKA). These statistics were available for 9 of the 18 hospitals in the canton that participated in the study. The number of cases identified from the VESKA statistics was compared to the total number of cases for each hospital. For the 9 hospitals the number of cases in the VESKA statistics was 407, whereas, after having excluded diagnoses that were actually "status after fracture" and double entries, the total for these hospitals was 392, that is 4% less than the VESKA statistics indicate. It is concluded that the VESKA statistics provide a good approximation of the actual number of cases treated in these hospitals, with a tendency to overestimate this number. In order to use these statistics for calculating incidence figures, however, it is imperative that a greater proportion of all hospitals (50% presently in the canton, 35% nationwide) participate in these statistics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT: To study a scan protocol for coronary magnetic resonance angiography based on multiple breath-holds featuring 1D motion compensation and to compare the resulting image quality to a navigator-gated free-breathing acquisition. Image reconstruction was performed using L1 regularized iterative SENSE. MATERIALS AND METHODS: The effects of respiratory motion on the Cartesian sampling scheme were minimized by performing data acquisition in multiple breath-holds. During the scan, repetitive readouts through a k-space center were used to detect and correct the respiratory displacement of the heart by exploiting the self-navigation principle in image reconstruction. In vivo experiments were performed in nine healthy volunteers and the resulting image quality was compared to a navigator-gated reference in terms of vessel length and sharpness. RESULTS: Acquisition in breath-hold is an effective method to reduce the scan time by more than 30 % compared to the navigator-gated reference. Although an equivalent mean image quality with respect to the reference was achieved with the proposed method, the 1D motion compensation did not work equally well in all cases. CONCLUSION: In general, the image quality scaled with the robustness of the motion compensation. Nevertheless, the featured setup provides a positive basis for future extension with more advanced motion compensation methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Principles: Surgeon's experience is crucial for proper application of sentinel node biopsy (SNB) in patients with breast cancer. A 20-30 cases learning curve of sentinel node (SN) and axillary lymph node dissection (ALND) was widely practiced. In order to speed up this learning curve, surgeons may be trained intraoperative by an experienced surgeon. The purpose of this report is to evaluate the results of this procedure. Methods: Patients with one primary invasive breast cancer (cT1-T2[<3 cm]cN0) underwent SNB based on lymphoscintigraphy using technetium Tc 99m colloid, intraoperative gamma probe detection, with or without blue dye mapping. This was followed by completion ALND when SN was positive or not found. SNB was performed by one experienced surgeon (teacher) or by 10 junior surgeons trained by the experienced surgeon (trainees). Four groups were defined: (i) SNB with immediate ALND for the teacher's learning curve, (ii) SNB by the teacher, (iii) SNB by the trainees under the teacher's supervision, and (iv) SNB by the trainees alone. Results: Between May 1999 and December 2007, a total of 808 évaluable patients underwent SNB. The SN identification rate was 98% in the teacher's group, and 99% in the trainees' group (p = 0.196). SN were positive in respectively 28% and 29% of patients (p = 0.196). The distribution of isolated tumor cells, micrometastases and metastases was not statistically different between the teacher's and the trainees' groups (p = 0.163). Conclusion: These comparable results confirm the success with which the SNB was taught. This strategy avoided the 20-30 SNB followed by immediate ALND early required per surgeon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction ICM+ software encapsulates our 20 years' experience in brain monitoring. It collects data from a variety of bedside monitors and produces time trends of parameters defi ned using confi gurable mathematical formulae. To date it is being used in nearly 40 clinical research centres worldwide. We present its application for continuous monitoring of cerebral autoregulation using near-infrared spectroscopy (NIRS). Methods Data from multiple bedside monitors are processed by ICM+ in real time using a large selection of signal processing methods. These include various time and frequency domain analysis functions as well as fully customisable digital fi lters. The fi nal results are displayed in a variety of ways including simple time trends, as well as time window based histograms, cross histograms, correlations, and so forth. All this allows complex information from bedside monitors to be summarized in a concise fashion and presented to medical and nursing staff in a simple way that alerts them to the development of various pathological processes. Results One hundred and fi fty patients monitored continuously with NIRS, arterial blood pressure (ABP) and intracranial pressure (ICP), where available, were included in this study. There were 40 severely headinjured adult patients, 27 SAH patients (NCCU, Cambridge); 60 patients undergoing cardiopulmonary bypass (John Hopkins Hospital, Baltimore) and 23 patients with sepsis (University Hospital, Basel). In addition, MCA fl ow velocity (FV) was monitored intermittently using transcranial Doppler. FV-derived and ICP-derived pressure reactivity indices (PRx, Mx), as well as NIRS-derived reactivity indices (Cox, Tox, Thx) were calculated and showed signifi cant correlation with each other in all cohorts. Errorbar charts showing reactivity index PRx versus CPP (optimal CPP chart) as well as similar curves for NIRS indices versus CPP and ABP were also demonstrated. Conclusions ICM+ software is proving to be a very useful tool for enhancing the battery of available means for monitoring cerebral vasoreactivity and potentially facilitating autoregulation guided therapy. Complexity of data analysis is also hidden inside loadable profi les, thus allowing investigators to take full advantage of validated protocols including advanced processing formulas.