197 resultados para Surgical implants
Resumo:
The 2009 International Society of Urological Pathology Consensus Conference in Boston, made recommendations regarding the standardization of pathology reporting of radical prostatectomy specimens. Issues relating to surgical margin assessment were coordinated by working group 5. Pathologists agreed that tumor extending close to the 'capsular' margin, yet not to it, should be reported as a negative margin, and that locations of positive margins should be indicated as either posterior, posterolateral, lateral, anterior at the prostatic apex, mid-prostate or base. Other items of consensus included specifying the extent of any positive margin as millimeters of involvement; tumor in skeletal muscle at the apical perpendicular margin section, in the absence of accompanying benign glands, to be considered organ confined; and that proximal and distal margins be uniformly referred to as bladder neck and prostatic apex, respectively. Grading of tumor at positive margins was to be left to the discretion of the reporting pathologists. There was no consensus as to how the surgical margin should be regarded when tumor is present at the inked edge of the tissue, in the absence of transected benign glands at the apical margin. Pathologists also did not achieve agreement on the reporting approach to benign prostatic glands at an inked surgical margin in which no carcinoma is present.
Resumo:
Background/Objectives:There is strong evidence for the beneficial effects of perioperative nutrition in patients undergoing major surgery. We aimed to evaluate implementation of current guidelines in Switzerland and Austria.Subjects/Methods:A survey was conducted in 173 Swiss and Austrian surgical departments. We inquired about nutritional screening, perioperative nutrition and estimated clinical significance.Results:The overall response rate was 55%, having 69% (54/78) responders in Switzerland and 44% (42/95) in Austria. Most centres were aware of reduced complications (80%) and shorter hospital stay (59%). However, only 20% of them implemented routine nutritional screening. Non-compliance was because of financial (49%) and logistic restrictions (33%). Screening was mainly performed in the outpatient's clinic (52%) or during admission (54%). The nutritional risk score was applied by 14% only; instead, various clinical (78%) and laboratory parameters (56%) were used. Indication for perioperative nutrition was based on preoperative screening in 49%. Although 23% used preoperative nutrition, 68% applied nutritional support pre- and postoperatively. Preoperative nutritional treatment ranged from 3 days (33%), to 5 (31%) and even 7 days (20%).Conclusions:Although malnutrition is a well-recognised risk factor for poor post-operative outcome, surgeons remain reluctant to implement routine screening and nutritional support according to evidence-based guidelines.
Resumo:
Posterolateral corner (PLC) injuries of the knee are uncommon injury patterns that may result in significant degrees of functional disability. When surgery is necessary to address this injury a good knowledge of anatomy and a good surgical exposure is the mainstay. This report reviews the complex anatomy of the posterolateral corner (PLC) of knee and describes the osteotomy of Gerdy tubercle as a technical variant to approach this anatomical region. This surgical step allowing a good mobilisation of the multiple layers of ilio-tibial tract from distal to proximal makes an excellent exposure of the PLC structures with absence of morbidity.
Resumo:
Treatment of retinal detachment frequently uses biocompatible materials to obtain scleral buckling. These materials are not devoid of consequences on surrounding tissues. In 3 eyes enucleated for failure of surgical treatment using scleral buckling materials, the changes prompted by episcleral implants could be observed. The sclera underwent both an inversion of its curvature and a reduction of its thickness under the material, as well as an encapsulation of the material was observed. While a silicone sponge was used in part to encircle one of these eyes, its capsular inner surface was regular and smooth. In contrast, hydrogel implants used in the three eyes showed a peripheral fragmentation prompting in two of them a typical foreign body giant cell granulomatous reaction. Changes in scleral curvature and scleral thinning were observed reflecting the consequences of the buckling procedure. The capsule formation occurred as it does for any nonabsorbable matérial implanted in tissues. Degradation and fragmentation of the hydrogel material suscitated a granuloma in response to fragments. These hydrogel specific changes should be recognized on microscopic examination of slides of either capsule or eyes previously in contact with this implanted material. They attested of the instability of hydrogel after implantation.
Resumo:
INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
Vitamin K deficiency bleeding within the first 24 h of life is caused in most cases by maternal drug intake (e.g. coumarins, anticonvulsants, tuberculostatics) during pregnancy. Haemorrhage is often life-threatening and usually not prevented by vitamin K prophylaxis at birth. We report a case of severe intracranial bleeding at birth secondary to phenobarbital-induced vitamin K deficiency and traumatic delivery. Burr hole trepanations of the skull were performed and the subdural haematoma was evacuated. Despite the severe prognosis, the infant showed an unexpected good recovery. At the age of 3 years, neurological examinations were normal as was the EEG at the age of 9 months. CT showed close to normal intracranial structures. CONCLUSION: This case report stresses the importance of antenatal vitamin K prophylaxis and the consideration of a primary Caesarean section in maternal vitamin K deficiency states and demonstrates the successful management of massive subdural haemorrhage by a limited surgical approach.
Resumo:
There is a clinical need to enhance functional recovery of injured peripheral nerves. Local administration of neurotrophic factors (NTFs) after surgical repair has been proposed for this purpose. Little is known, however, on the optimal local dose and dosing frequency of NTFs in a peripheral nerve defect. For increasing our knowledge on biologically relevant local NTFs concentrations and for making available an in vitro assay for assessing the bioactivity of NTFs in connection with implantable localized delivery systems, we developed in this study a bioassay for NTFs, which is based on dorsal root ganglion (DRG) explants from E9 (9 days old) chicken embryos. Axonal elongation and extent of axonal branching was analyzed microscopically after addition of glial cell line-derived neurotrophic factor (GDNF) and nerve growth factor (NGF), each alone and in combination. GDNF significantly promoted axonal elongation, but only little axonal branching, whereas NGF induced extensive axonal branching with modest axonal elongation. The combination of GDNF and NGF exerted a synergistic effect on the axonal elongation, axonal branching and growth kinetics. GDNF and NGF also enhanced the expression of their respective functional receptors Ret and TrkA on the DRG neurons. This information should be relevant for the development of implants containing NTFs and on drug therapy of damaged peripheral nerves.
Resumo:
It is debated whether chronic hypertension increases the risk of cardiovascular incidents during anaesthesia. We studied all elective surgical operations performed in adults under general or regional anaesthesia between 2000 and 2004, in 24 hospitals collecting computerised clinical data on all anaesthetics since 1996. The focus was on cardiovascular incidents, though other anaesthesia-related incidents were also evaluated. Among 124,939 interventions, 27,881 (22%) were performed in hypertensive patients. At least one cardiovascular incident occurred in 7549 interventions (6% (95% CI 5.9-6.2%)). The average adjusted odds ratio of cardiovascular risk for chronic hypertension was 1.38 (95% CI 1.27-1.49). However, across hospitals, adjusted odd ratios varied from 0.41 up to 2.25. Hypertension did not increase the risk of other incidents. Hypertensive patients are still at risk of intra-operative cardiovascular incidents, while risk heterogeneity across hospitals, despite taking account of casemix and hospital characteristics, suggests variations in anaesthetic practices.