52 resultados para Speed and torque observers
Resumo:
Challenging environmental conditions, including heat and humidity, cold, and altitude, pose particular risks to the health of Olympic and other high-level athletes. As a further commitment to athlete safety, the International Olympic Committee (IOC) Medical Commission convened a panel of experts to review the scientific evidence base, reach consensus, and underscore practical safety guidelines and new research priorities regarding the unique environmental challenges Olympic and other international-level athletes face. For non-aquatic events, external thermal load is dependent on ambient temperature, humidity, wind speed and solar radiation, while clothing and protective gear can measurably increase thermal strain and prompt premature fatigue. In swimmers, body heat loss is the direct result of convection at a rate that is proportional to the effective water velocity around the swimmer and the temperature difference between the skin and the water. Other cold exposure and conditions, such as during Alpine skiing, biathlon and other sliding sports, facilitate body heat transfer to the environment, potentially leading to hypothermia and/or frostbite; although metabolic heat production during these activities usually increases well above the rate of body heat loss, and protective clothing and limited exposure time in certain events reduces these clinical risks as well. Most athletic events are held at altitudes that pose little to no health risks; and training exposures are typically brief and well-tolerated. While these and other environment-related threats to performance and safety can be lessened or averted by implementing a variety of individual and event preventative measures, more research and evidence-based guidelines and recommendations are needed. In the mean time, the IOC Medical Commission and International Sport Federations have implemented new guidelines and taken additional steps to mitigate risk even further.
Resumo:
The aim of this study was to determine potential relationships between anthropometric parameters and athletic performance with special consideration to repeated-sprint ability (RSA). Sixteen players of the senior male Qatar national soccer team performed a series of anthropometric and physical tests including countermovement jumps without (CMJ) and with free arms (CMJwA), straight-line 20 m sprint, RSA (6 × 35 m with 10 s recovery) and incremental field test. Significant (P < 0.05) relationships occurred between muscle-to-bone ratio and both CMJs height (r ranging from 0.56 to 0.69) as well as with all RSA-related variables (r < -0.53 for sprinting times and r = 0.54 for maximal sprinting speed) with the exception of the sprint decrement score (Sdec). The sum of six skinfolds and adipose mass index were largely correlated with Sdec (r = 0.68, P < 0.01 and r = 0.55, P < 0.05, respectively) but not with total time (TT, r = 0.44 and 0.33, P > 0.05, respectively) or any standard athletic tests. Multiple regression analyses indicated that muscular cross-sectional area for mid-thigh, adipose index, straight-line 20 m time, maximal sprinting speed and CMJwA are the strongest predictors of Sdec (r(2) = 0.89) and TT (r(2) = 0.95) during our RSA test. In the Qatar national soccer team, players' power-related qualities and RSA are associated with a high muscular profile and a low adiposity. This supports the relevance of explosive power for the soccer players and the larger importance of neuromuscular qualities determining the RSA.
Resumo:
In this paper, we present an efficient numerical scheme for the recently introduced geodesic active fields (GAF) framework for geometric image registration. This framework considers the registration task as a weighted minimal surface problem. Hence, the data-term and the regularization-term are combined through multiplication in a single, parametrization invariant and geometric cost functional. The multiplicative coupling provides an intrinsic, spatially varying and data-dependent tuning of the regularization strength, and the parametrization invariance allows working with images of nonflat geometry, generally defined on any smoothly parametrizable manifold. The resulting energy-minimizing flow, however, has poor numerical properties. Here, we provide an efficient numerical scheme that uses a splitting approach; data and regularity terms are optimized over two distinct deformation fields that are constrained to be equal via an augmented Lagrangian approach. Our approach is more flexible than standard Gaussian regularization, since one can interpolate freely between isotropic Gaussian and anisotropic TV-like smoothing. In this paper, we compare the geodesic active fields method with the popular Demons method and three more recent state-of-the-art algorithms: NL-optical flow, MRF image registration, and landmark-enhanced large displacement optical flow. Thus, we can show the advantages of the proposed FastGAF method. It compares favorably against Demons, both in terms of registration speed and quality. Over the range of example applications, it also consistently produces results not far from more dedicated state-of-the-art methods, illustrating the flexibility of the proposed framework.
Resumo:
The Gene Ontology (GO) Consortium (http://www.geneontology.org) (GOC) continues to develop, maintain and use a set of structured, controlled vocabularies for the annotation of genes, gene products and sequences. The GO ontologies are expanding both in content and in structure. Several new relationship types have been introduced and used, along with existing relationships, to create links between and within the GO domains. These improve the representation of biology, facilitate querying, and allow GO developers to systematically check for and correct inconsistencies within the GO. Gene product annotation using GO continues to increase both in the number of total annotations and in species coverage. GO tools, such as OBO-Edit, an ontology-editing tool, and AmiGO, the GOC ontology browser, have seen major improvements in functionality, speed and ease of use.
Resumo:
BACKGROUND: Health risks associated with subclinical hypothyroidism in older adults are unclear. Our objective was to compare the functional mobility of people aged 70 to 79 years by thyroid function categorized by thyrotropin (TSH) level as euthyroid (>or=0.4 to <4.5 mIU/L), mild subclinical hypothyroid (>or=4.5 to <7.0 mIU/L), or moderate subclinical hypothyroid (>or=7.0 to <or=20.0 mIU/L with a normal free thyroxine level) cross-sectionally and over 2 years. METHODS: A total of 2290 community-dwelling residents participating in the year 2 clinic visit (July 1998-June 1999) of the Health, Aging, and Body Composition (Health ABC) Study, who had measured TSH level, had the capacity to walk 20 m unaided, and were not taking thyroid medication or had TSH levels consistent with hyperthyroidism or hypothyroidism. Main outcome measures included self-reported and performance-based measures of mobility (usual and rapid gait speed and endurance walking ability) assessed at study baseline (year 2) and 2 years later. RESULTS: In age- and sex-adjusted analyses, the mild subclinical hypothyroid group (vs the euthyroid group) demonstrated better mobility (faster mean usual and rapid gait speed [1.20 vs 1.15 m/s and 1.65 vs 1.56 m/s, respectively; P < .001] and had a higher percentage of those with good cardiorespiratory fitness and reported walking ease [39.2% vs 28.0% and 44.7% vs 36.5%, respectively; P < .001]). After 2 years, persons with mild subclinical hypothyroidism experienced a similar decline as the euthyroid group but maintained their mobility advantage. Persons with moderate subclinical hypothyroidism had similar mobility and mobility decline as the euthyroid group. CONCLUSION: Generally, well-functioning 70- to 79-year-old individuals with subclinical hypothyroidism do not demonstrate increased risk of mobility problems, and those with mild elevations in TSH level show a slight functional advantage.
Resumo:
BACKGROUND: Grip strength, walking speed, chair rising and standing balance time are objective measures of physical capability that characterise current health and predict survival in older populations. Socioeconomic position (SEP) in childhood may influence the peak level of physical capability achieved in early adulthood, thereby affecting levels in later adulthood. We have undertaken a systematic review with meta-analyses to test the hypothesis that adverse childhood SEP is associated with lower levels of objectively measured physical capability in adulthood. METHODS AND FINDINGS: Relevant studies published by May 2010 were identified through literature searches using EMBASE and MEDLINE. Unpublished results were obtained from study investigators. Results were provided by all study investigators in a standard format and pooled using random-effects meta-analyses. 19 studies were included in the review. Total sample sizes in meta-analyses ranged from N = 17,215 for chair rise time to N = 1,061,855 for grip strength. Although heterogeneity was detected, there was consistent evidence in age adjusted models that lower childhood SEP was associated with modest reductions in physical capability levels in adulthood: comparing the lowest with the highest childhood SEP there was a reduction in grip strength of 0.13 standard deviations (95% CI: 0.06, 0.21), a reduction in mean walking speed of 0.07 m/s (0.05, 0.10), an increase in mean chair rise time of 6% (4%, 8%) and an odds ratio of an inability to balance for 5s of 1.26 (1.02, 1.55). Adjustment for the potential mediating factors, adult SEP and body size attenuated associations greatly. However, despite this attenuation, for walking speed and chair rise time, there was still evidence of moderate associations. CONCLUSIONS: Policies targeting socioeconomic inequalities in childhood may have additional benefits in promoting the maintenance of independence in later life.
Resumo:
In a system where tens of thousands of words are made up of a limited number of phonemes, many words are bound to sound alike. This similarity of the words in the lexicon as characterized by phonological neighbourhood density (PhND) has been shown to affect speed and accuracy of word comprehension and production. Whereas there is a consensus about the interfering nature of neighbourhood effects in comprehension, the language production literature offers a more contradictory picture with mainly facilitatory but also interfering effects reported on word production. Here we report both of these two types of effects in the same study. Multiple regression mixed models analyses were conducted on PhND effects on errors produced in a naming task by a group of 21 participants with aphasia. These participants produced more formal errors (interfering effect) for words in dense phonological neighbourhoods, but produced fewer nonwords and semantic errors (a facilitatory effect) with increasing density. In order to investigate the nature of these opposite effects of PhND, we further analysed a subset of formal errors and nonword errors by distinguishing errors differing on a single phoneme from the target (corresponding to the definition of phonological neighbours) from those differing on two or more phonemes. This analysis confirmed that only formal errors that were phonological neighbours of the target increased in dense neighbourhoods, while all other errors decreased. Based on additional observations favouring a lexical origin of these formal errors (they exceeded the probability of producing a real-word error by chance, were of a higher frequency, and preserved the grammatical category of the targets), we suggest that the interfering effect of PhND is due to competition between lexical neighbours and target words in dense neighbourhoods.
Resumo:
PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.
Resumo:
The purpose of this study was to estimate the energy cost of linear (EC) and vertical displacement (ECvert), mechanical efficiency and main stride parameters during simulated ski mountaineering at different speeds and gradients, to identify an optimal speed and gradient that maximizes performance. 12 subjects roller skied on a treadmill at three different inclines (10, 17 and 24 %) at three different speeds (approximately 70, 80 and 85 % of estimated peak heart rate). Energy expenditure was calculated by indirect calorimetry, while biomechanical parameters were measured with an inertial sensor-based system. At 10 % there was no significant change with speed in EC, ECvert and mechanical efficiency. At 17 and 24 % the fastest speed was significantly more economical. There was a significant effect of gradient on EC, ECvert and mechanical efficiency. The most economical gradient was the steepest one. There was a significant increase of stride frequency with speed. At steep gradients only, relative thrust phase duration decreased significantly, while stride length increased significantly with speed. There was a significant effect of gradient on stride length (decrease with steepness) and relative thrust phase duration (increase with steepness). A combination of a decreased relative thrust phase duration with increased stride length and frequency decreases ECvert. To minimize the energy expenditure to reach the top of a mountain and to optimize performance, ski-mountaineers should choose a steep gradient (~24 %) and, provided they possess sufficient metabolic scope, combine it with a fast speed (~6 km h(-1)).
Resumo:
PURPOSE: To assess the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography of the wrist with regard to joint space width and amount of contrast material between the opposing cartilage surfaces. MATERIALS AND METHODS: Fifteen consecutive patients (12 male, mean age 38.1 years) were included in this Institutional Review Board-approved prospective study. Three-compartment wrist MR arthrographies were performed between October and December 2009 on a 3 T unit using a fat-suppressed T1-weighted isotropic high-resolution volumetric interpolated breathhold examination (VIBE) sequence in the coronal plane, with and without axial traction (3 kg). Two radiologists measured radiocarpal (radioscaphoid, radiolunate) and midcarpal (lunocapitate, hamatolunate) joint space widths, with and without traction, and assessed the amount of contrast material between the opposing cartilage surfaces using a three-point scale: 0 = absence, 1 = partial, 2 = complete. RESULTS: With traction, joint space width increased significantly at the radioscaphoid (Delta = 0.78 mm, P < 0.01), radiolunate (Delta = 0.18 mm, P < 0.01), and lunocapitate (Delta = 0.45 mm, P < 0.01) spaces, and both observers detected significantly more contrast material between the cartilage surfaces. At the hamatolunate space, the differences in joint space width (Delta = 0.14 mm, P = 0.54) and amount of contrast material were not significant. CONCLUSION: Direct wrist MR arthrography with axial traction of 3 kg increases joint space width at the radiocarpal and lunocapitate spaces, and prompts better coverage of the articular cartilage by the contrast material. J. Magn. Reson. Imaging 2011;. (c) 2011 Wiley-Liss, Inc.
Resumo:
It has been reported in the literature that executive functions may be fractioned into updating, shifting, and inhibition. The present study aimed to explore whether these executive sub-components can be identified in a more age-heterogeneous sample and see if they are prone to an age-related decline. We tested the performances of 81 individuals aged from 18 to 88 years old in each executive sub-component, working memory, fluid intelligence and processing speed. Correlation analysis revealed only a slight positive relationship between the two updating measures. A linear decrement with age was observed only for two complex executive tests. Tasks indexing working memory, processing speed and fluid intelligence showed a stronger linear decline with age than executive tasks. In conclusion, our results did not replicate the executive structure known from the literature, and revealed that decrement in executive function is not an unavoidable concomitant of aging but rather concerns specific executive tasks.
Resumo:
Rapid neurotransmitter release depends on the ability to arrest the SNAP receptor (SNARE)-dependent exocytosis pathway at an intermediate "cocked" state, from which fusion can be triggered by Ca(2+). It is not clear whether this state includes assembly of synaptobrevin (the vesicle membrane SNARE) to the syntaxin-SNAP-25 (target membrane SNAREs) acceptor complex or whether the reaction is arrested upstream of that step. In this study, by a combination of in vitro biophysical measurements and time-resolved exocytosis measurements in adrenal chromaffin cells, we find that mutations of the N-terminal interaction layers of the SNARE bundle inhibit assembly in vitro and vesicle priming in vivo without detectable changes in triggering speed or fusion pore properties. In contrast, mutations in the last C-terminal layer decrease triggering speed and fusion pore duration. Between the two domains, we identify a region exquisitely sensitive to mutation, possibly constituting a switch. Our data are consistent with a model in which the N terminus of the SNARE complex assembles during vesicle priming, followed by Ca(2+)-triggered C-terminal assembly and membrane fusion.
Resumo:
A child's natural gait pattern may be affected by the gait laboratory environment. Wearable devices using body-worn sensors have been developed for gait analysis. The purpose of this study was to validate and explore the use of foot-worn inertial sensors for the measurement of selected spatio-temporal parameters, based on the 3D foot trajectory, in independently walking children with cerebral palsy (CP). We performed a case control study with 14 children with CP aged 6-15 years old and 15 age-matched controls. Accuracy and precision of the foot-worn device were measured using an optical motion capture system as the reference system. Mean accuracy±precision for both groups was 3.4±4.6cm for stride length, 4.3±4.2cm/s for speed and 0.5±2.9° for strike angle. Longer stance and shorter swing phases with an increase in double support were observed in children with CP (p=0.001). Stride length, speed and peak angular velocity during swing were decreased in paretic limbs, with significant differences in strike and lift-off angles. Children with cerebral palsy showed significantly higher inter-stride variability (measured by their coefficient of variation) for speed, stride length, swing and stance. During turning trajectories speed and stride length decreased significantly (p<0.01) for both groups, whereas stance increased significantly (p<0.01) in CP children only. Foot-worn inertial sensors allowed us to analyze gait spatiotemporal data outside a laboratory environment with good accuracy and precision and congruent results with what is known of gait variations during linear walking in children with CP.
Resumo:
It is established that the ratio between step length (SL) and step frequency (SF) is constant over a large range of walking speed. However, few data are available about the spontaneous variability of this ratio during unconstrained outdoor walking, in particular over a sufficient number of steps. The purpose of the present study was to assess the inter- and intra-subject variability of spatio-temporal gait characteristics [SL, SF and walk ratio (WR=SL/SF)] while walking at different freely selected speeds. Twelve healthy subjects walked three times along a 100-m athletic track at: (1). a slower than preferred speed, (2). preferred speed and (3). a faster than preferred speed. Two professional GPS receivers providing 3D positions assessed the walking speed and SF with high precision (less than 0.5% error). Intra-subject variability was calculated as the variation among eight consecutive 5-s samples. WR was found to be constant at preferred and fast speeds [0.41 (0.04) m.s and 0.41 (0.05) m.s respectively] but was higher at slow speeds [0.44 (0.05) m.s]. In other words, between slow and preferred speed, the speed increase was mediated more by a change in SF than SL. The intra-subject variability of WR was low under preferred [CV, coefficient of variation = 1.9 (0.6)%] and fast [CV=1.8 (0.5)%] speed conditions, but higher under low speed condition [CV=4.1 (1.5)%]. On the other hand, the inter-subject variability of WR was 11%, 10% and 12% at slow, preferred and fast walking speeds respectively. It is concluded that the GPS method is able to capture basic gait parameters over a short period of time (5 s). A specific gait pattern for slow walking was observed. Furthermore, it seems that the walking patterns in free-living conditions exhibit low intra-individual variability, but that there is substantial variability between subjects.
Resumo:
Introduction: Falls efficacy, defined as confidence in performing activities without falling, is a measure of fear of falling associated with gait impairment, falls and functional decline in frail older people. This relationship has not been well studied in high-functioning older people. Objective: To evaluate the relationship between falls efficacy and gait performance in a cohort of high-functioning older people. Methods: Subjects (N = 864) were a subsample of communitydwelling older people aged 65 to 70 years, enrolled in the "Lc65+" cohort, who completed gait assessment at baseline. Data were collected on demographics, functional, cognitive, affective, and health status. Falls efficacy was assessed using the Falls Efficacy Scale- International (FES-I) that measures confidence in performing 16 activities of daily life (ADL) without falling (score from 16 to 64, higher score indicates lower confidence). Gait parameters were measured over a 20 m walk at preferred gait speed using Physilog, an ambulatory gait monitoring system. Results: Participants (mean age 68.0 ± 1.4 years, 55.0% women) had excellent physical (92.2% independent in basic ADL, mean gait speed 1.13 ± 0.16 m/sec) and cognitive (98.0% with MMSE 024) performance. Nevertheless, 22.1% reported depressive symptoms and 16.1% one or more fall in the previous year. Mean FES-I score was 18.8 ± 4.1. Falls efficacy was associated with gait speed (Spearman rho -0.23, P <.001) and gait variability (Spearman rho 0.10, P = .006), measured by the coefficient of variation of stride velocity. These associations remained in multivariate analysis for both gait speed (adj [beta] coeff: -0.008, 95%CI -0.005 to -0.010, P <.001) and gait variability (adj [beta] coeff 0.024, 95%CI 0.003 to 0.045, P = .023) independent of gender, falls, functional, affective, cognitive, and frailty (Fried's criteria) status. On average, compared to subjects with poor confidence in performing one ADL without falling, those with full confidence had a 0.02 m/sec (2%) faster gait speed and a 2% decrease in gait variability. Conclusion: Even in high-functioning older people, poor falls efficacy is associated with reduced gait speed and stability, independent of health, functional, and frailty status. The direction of this relationship needs to be investigated prospectively to determine causality and design interventions to improve gait performance, reduce fall risk, and prevent functional decline.