83 resultados para Software testing. Test generation. Grammars


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This study investigated maximal cardiometabolic response while running in a lower body positive pressure treadmill (antigravity treadmill (AG)), which reduces body weight (BW) and impact. The AG is used in rehabilitation of injuries but could have potential for high-speed running, if workload is maximally elevated. METHODS: Fourteen trained (nine male) runners (age 27 ± 5 yr; 10-km personal best, 38.1 ± 1.1 min) completed a treadmill incremental test (CON) to measure aerobic capacity and heart rate (V˙O2max and HRmax). They completed four identical tests (48 h apart, randomized order) on the AG at BW of 100%, 95%, 90%, and 85% (AG100 to AG85). Stride length and rate were measured at peak velocities (Vpeak). RESULTS: V˙O2max (mL·kg·min) was similar across all conditions (men: CON = 66.6 (3.0), AG100 = 65.6 (3.8), AG95 = 65.0 (5.4), AG90 = 65.6 (4.5), and AG85 = 65.0 (4.8); women: CON = 63.0 (4.6), AG100 = 61.4 (4.3), AG95 = 60.7 (4.8), AG90 = 61.4 (3.3), and AG85 = 62.8 (3.9)). Similar results were found for HRmax, except for AG85 in men and AG100 and AG90 in women, which were lower than CON. Vpeak (km·h) in men was 19.7 (0.9) in CON, which was lower than every other condition: AG100 = 21.0 (1.9) (P < 0.05), AG95 = 21.4 (1.8) (P < 0.01), AG90 = 22.3 (2.1) (P < 0.01), and AG85 = 22.6 (1.6) (P < 0.001). In women, Vpeak (km·h) was similar between CON (17.8 (1.1) ) and AG100 (19.3 (1.0)) but higher at AG95 = 19.5 (0.4) (P < 0.05), AG90 = 19.5 (0.8) (P < 0.05), and AG85 = 21.2 (0.9) (P < 0.01). CONCLUSIONS: The AG can be used at maximal exercise intensities at BW of 85% to 95%, reaching faster running speeds than normally feasible. The AG could be used for overspeed running programs at the highest metabolic response levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

C.E.R.A., a continuous erythropoietin receptor activator, is a new third-generation erythropoiesis-stimulating agent (ESA) that has recently been linked with abuse in endurance sports. In order to combat this new form of doping, we examined an enzyme-linked immunosorbent assay (ELISA) designed to detect the presence of C.E.R.A. in serum samples. The performance of the assay was evaluated using a pilot excretion study that involved six subjects receiving C.E.R.A. Validation data demonstrated an excellent reproducibility and ensured the applicability of the assay for anti-doping purposes. To maximize the chances of detecting the drug in serum samples, we propose the use of this specific ELISA test as a high-throughput screening method, combined with a classic isoelectric focusing test as a confirmatory assay. This strategy should make C.E.R.A. abuse relatively easy to detect, thereby preventing the future use of this drug as a doping agent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The National Institute of Mental Health developed the semi-structured Diagnostic Interview for Genetic Studies (DIGS) for the assessment of major mood and psychotic disorders and their spectrum conditions. The DIGS was translated into French in a collaborative effort of investigators from sites in France and Switzerland. Inter-rater and test-retest reliability of the French version have been established in a clinical sample in Lausanne. Excellent inter-rater reliability was found for schizophrenia, bipolar disorder, major depression, and unipolar schizoaffective disorder while fair inter-rater reliability was demonstrated for bipolar schizoaffective disorder. Using a six-week test-retest interval, reliability for all diagnoses was found to be fair to good with the exception of bipolar schizoaffective disorder. The lower test-retest reliability was the result of a relatively long test-retest interval that favored incomplete symptom recall. In order to increase reliability for lifetime diagnoses in persons not currently affected, best-estimate procedures using additional sources of diagnostic information such as medical records and reports from relatives should supplement DIGS information in family-genetic studies. Within such a procedure, the DIGS appears to be a useful part of data collection for genetic studies on major mood disorders and schizophrenia in French-speaking populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compares the clientele of a Swiss anonymous test centre with the general population tested. Information was obtained through similar questionnaires submitted to two samples of HIV-tested people aged from 17 to 45 years: the first administered in the context of a general population telephone survey (n = 245) and the second completed during face-to-face interviews of the clientele of an anonymous test centre (n = 250). The test centre sample has higher proportions of younger and single people. Attenders for anonymous testing were more likely to have acquired a new regular partner during the year preceding the interview (48.0% versus 14.4%). These differences remain when controlling for age and gender. Decision to test comes mostly from the respondent's own initiative, but suggestion from a doctor is more frequent in the general population (23.8% versus 0.8%), whereas suggestion from partner or friends is more frequent in the anonymous centre (44.4% versus 3.0%). The anonymous test centre clientele is not different from the general population tested except for the relational situation and origin of decision for testing. The test centre has become a place where the general population finds a response to a situation-specific need for HIV testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Crizotinib is a first-in-class oral anaplastic lymphoma kinase (ALK) inhibitor targeting ALK-rearranged non-small-cell lung cancer. The therapy was approved by the US FDA in August 2011 and received conditional marketing approval by the European Commission in October 2012 for advanced non-small-cell lung cancer. A break-apart FISH-based assay was jointly approved with crizotinib by the FDA. This assay and an immunohistochemistry assay that uses a D5F3 rabbit monoclonal primary antibody were also approved for marketing in Europe in October 2012. While ALK rearrangement has relatively low prevalence, a clinical benefit is exhibited in more than 85% of patients with median progression-free survival of 8-10 months. In this article, the authors summarize the therapy and alternative test strategies for identifying patients who are likely to respond to therapy, including key issues for effective and efficient testing. The key economic considerations regarding the joint companion diagnostic and therapy are also presented. Given the observed clinical benefit and relatively high cost of crizotinib therapy, companion diagnostics should be evaluated relative to response to therapy versus correlation alone whenever possible, and both high inter-rater reliability and external quality assessment programs are warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The prevalence of small intestinal bowel bacterial overgrowth (SIBO) in patients with irritable bowel syndrome (IBS) ranges from 43% to 78% as determined by the lactulose hydrogen breath (LHBT) test. Although rifaximine, a non-absorbable antibiotic, has been able to decrease global IBS symptoms as well as bloating in placebo-controlled randomized trials, these results were not repeated in phase IV studies in daily clinical practice. Aim: To assess the prevalence of SIBO in an IBS cohort and to evaluate the treatment response in the IBS cohort affected by SIBO. Methods: Enrolled patients were diagnosed with IBS using the following criteria: fulfillment of the Rome III criteria, absence of alarm symptoms (anemia, weight loss, nocturnal symptoms etc), normal fecal calproectin, normal endoscopic workup including histology. Celiac disease was excluded by serology and/or duodenal biopsy. All patients underwent lactulose hydrogen breath testing (LHBT) for SIBO diagnosis. Patients with SIBO were treated with rifaximine tablets (400mg twice daily for 14 days). Both before and at week 6 after rifaximin treatment, patients completed a questionnaire, where the following criteria were assessed individually using 11-point Likert scales: the bloating, flatulence, abdominal pain, diarrhea, and overall well-being. Results: Hundred-fifty IBS patients were enrolled (76% female, mean age 44 ± 16 years), of whom 106 (71%) were diagnosed with SIBO and consequently treated with rifaximine. Rifaximine treatment significantly reduced the following symptoms as assessed by the symptom questionnaire: bloating (5.5 ± 2.6 before vs. 3.6 ± 2.7 after treatment, p <0.001), flatulence (5 ± 2.7 vs. 4 ± 2.7, p = 0.015), diarrhea (2.9 ± 2.4 vs. 2 ± 2.4, p = 0.005), abdominal pain (4.8 ± 2.7 vs. 3.3 ± 2.5, p <0.001) and resulted in improved overall well-being (3.9 ± 2.4 vs. 2.7 ± 2.3, p <0.001). Thirteen of the 106 treated patients were lost to follow-up (12%). The LHBT was repeated 2-4 weeks after rifaximine treatment in 65/93 (70%) patients. Eradication of SIBO was documented in 85% of all patients (55/65), whereas 15% of patients (10/65) tested positive for SIBO as determined by the LHBT testing. Conclusions: The results of our phase IV trial indicate that a high proportion of IBS patients tested positive for SIBO. IBS symptoms (bloating, flatulence, diarrhea, pain, overall well-being) were significantly diminished following a 2-week treatment with rifaximine. These results support the previous findings of randomized controlled trials that the presence of SIBO is associated with symptom generation in IBS patients and that reduction and/or elimination of SIBO may help to alleviate IBSassociated symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interpretability and power of genome-wide association studies can be increased by imputing unobserved genotypes, using a reference panel of individuals genotyped at higher marker density. For many markers, genotypes cannot be imputed with complete certainty, and the uncertainty needs to be taken into account when testing for association with a given phenotype. In this paper, we compare currently available methods for testing association between uncertain genotypes and quantitative traits. We show that some previously described methods offer poor control of the false-positive rate (FPR), and that satisfactory performance of these methods is obtained only by using ad hoc filtering rules or by using a harsh transformation of the trait under study. We propose new methods that are based on exact maximum likelihood estimation and use a mixture model to accommodate nonnormal trait distributions when necessary. The new methods adequately control the FPR and also have equal or better power compared to all previously described methods. We provide a fast software implementation of all the methods studied here; our new method requires computation time of less than one computer-day for a typical genome-wide scan, with 2.5 M single nucleotide polymorphisms and 5000 individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are no validated criteria for the diagnosis of sensory neuronopathy (SNN) yet. In a preliminary monocenter study a set of criteria relying on clinical and electrophysiological data showed good sensitivity and specificity for a diagnosis of probable SNN. The aim of this study was to test these criteria on a French multicenter study. 210 patients with sensory neuropathies from 15 francophone reference centers for neuromuscular diseases were included in the study with an expert diagnosis of non-SNN, SNN or suspected SNN according to the investigations performed in these centers. Diagnosis was obtained independently from the set of criteria to be tested. The expert diagnosis was taken as the reference against which the proposed SNN criteria were tested. The set relied on clinical and electrophysiological data easily obtainable with routine investigations. 9/61 (16.4 %) of non-SNN patients, 23/36 (63.9 %) of suspected SNN, and 102/113 (90.3 %) of SNN patients according to the expert diagnosis were classified as SNN by the criteria. The SNN criteria tested against the expert diagnosis in the SNN and non-SNN groups had 90.3 % (102/113) sensitivity, 85.2 % (52/61) specificity, 91.9 % (102/111) positive predictive value, and 82.5 % (52/63) negative predictive value. Discordance between the expert diagnosis and the SNN criteria occurred in 20 cases. After analysis of these cases, 11 could be reallocated to a correct diagnosis in accordance with the SNN criteria. The proposed criteria may be useful for the diagnosis of probable SNN in patients with sensory neuropathy. They can be reached with simple clinical and paraclinical investigations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fine particulate matter from traffic increases mortality and morbidity. An important source of traffic particles is brake wear. American studies reported cars to emit break wear particles at a rate of about 11mg/km to 20mg/km of driven distance. A German study estimated that break wear contributes about 12.5% to 21% of the total traffic particle emissions. The goal of this study was to build a system that allows the study of brake wear particle emissions during different braking behaviours of different car and brake types. The particles should be characterize in terms of size, number, metal, and elemental and organic carbon composition. In addition, the influence of different deceleration schemes on the particle composition and size distribution should be studied. Finally, this system should allow exposing human cell cultures to these particles. An exposure-box (0.25 cubic-m volume) was built that can be mounted around a car's braking system. This allows exposing cells to fresh brake wear particles. Concentrations of particle numbers, mass and surface, metals, and carbon compounds were quantified. Tests were conducted with A549 lung epithelial cells. Five different cars and two typical braking behaviours (full stop and normal deceleration) were tested. Particle number and size distribution was analysed for the first six minutes. In this time, two braking events occurred. Full stop produced significantly higher particle concentrations than normal deceleration (average of 23'000 vs. 10'400 #/cm3, p= 0.016). The particle number distribution was bi-modal with one peak at 60 to 100 nm (depending on the tested car and braking behaviour) and a second peak at 200 to 400 nm. Metal concentrations varied depending on the tested car type. Iron (range of 163 to 15'600 μg/m3) and Manganese (range of 0.9 to 135 μg/m3) were present in all samples, while Copper was absent in some samples (<6 to 1220 μg/m3). The overall "fleet" metal ratio was Fe:Cu:Mn = 128:14:1. Temperature and humidity varied little. A549-cells were successfully exposed in the various experimental settings and retained their viability. Culture supernatant was stored and cell culture samples were fixated to test for inflammatory response. Analysis of these samples is ongoing. The established system allowed testing brake wear particle emissions from real-world cars. The large variability of chemical composition and emitted amounts of brake wear particles between car models seems to be related to differences between brake pad compositions of different producers. Initial results suggest that the conditions inside the exposure box allow exposing human lung epithelial cells to freshly produced brake wear particles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hereditary non-structural diseases such as catecholaminergic polymorphic ventricular tachycardia (CPVT), long QT, and the Brugada syndrome as well as structural disease such as hypertrophic cardiomyopathy (HCM) and arrhythmogenic right ventricular cardiomyopathy (ARVC) cause a significant percentage of sudden cardiac deaths in the young. In these cases, genetic testing can be useful and does not require proxy consent if it is carried out at the request of judicial authorities as part of a forensic death investigation. Mutations in several genes are implicated in arrhythmic syndromes, including SCN5A, KCNQ1, KCNH2, RyR2, and genes causing HCM. If the victim's test is positive, this information is important for relatives who might be themselves at risk of carrying the disease-causing mutation. There is no consensus about how professionals should proceed in this context. This article discusses the ethical and legal arguments in favour of and against three options: genetic testing of the deceased victim only; counselling of relatives before testing the victim; counselling restricted to relatives of victims who tested positive for mutations of serious and preventable diseases. Legal cases are mentioned that pertain to the duty of geneticists and other physicians to warn relatives. Although the claim for a legal duty is tenuous, recent publications and guidelines suggest that geneticists and others involved in the multidisciplinary approach of sudden death (SD) cases may, nevertheless, have an ethical duty to inform relatives of SD victims. Several practical problems remain pertaining to the costs of testing, the counselling and to the need to obtain permission of judicial authorities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: According to guidelines, patients with coronary artery disease (CAD) should undergo revascularization if myocardial ischemia is present. While coronary angiography (CXA) allows the morphological assessment of CAD, the fractional flow reserve (FFR) has proved to be a complementary invasive test to assess the functional significance of CAD, i.e. to detect ischemia. Perfusion Cardiac Magnetic Resonance (CMR) has turned out to be a robust non-invasive technique to assess myocardial ischemia. The objective: is to compare the cost-effectiveness ratio - defined as the costs per patient correctly diagnosed - of two algorithms used to diagnose hemodynamically significant CAD in relation to the pretest likelihood of CAD: 1) aCMRto assess ischemia before referring positive patients to CXA (CMR + CXA), 2) a CXA in all patients combined with a FFR test in patients with angiographically positive stenoses (CXA + FFR). Methods: The costs, evaluated from the health care system perspective in the Swiss, German, the United Kingdom (UK) and the United States (US) contexts, included public prices of the different tests considered as outpatient procedures, complications' costs and costs induced by diagnosis errors (false negative). The effectiveness criterion wasthe ability to accurately identify apatient with significantCAD.Test performancesused in the model were based on the clinical literature. Using a mathematical model, we compared the cost-effectiveness ratio for both algorithms for hypothetical patient cohorts with different pretest likelihood of CAD. Results: The cost-effectiveness ratio decreased hyperbolically with increasing pretest likelihood of CAD for both strategies. CMR + CXA and CXA + FFR were equally costeffective at a pretest likelihood of CAD of 62% in Switzerland, 67% in Germany, 83% in the UK and 84% in the US with costs of CHF 5'794, Euros 1'472, £ 2'685 and $ 2'126 per patient correctly diagnosed. Below these thresholds, CMR + CXA showed lower costs per patient correctly diagnosed than CXA + FFR. Implications for the health care system/professionals/patients/society These results facilitate decision making for the clinical use of new generations of imaging procedures to detect ischemia. They show to what extent the cost-effectiveness to diagnose CAD depends on the prevalence of the disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Current nuclear medicine techniques for the localization of inflammatory processes are based on injection of 111In labelled autologous granulocytes which need to be isolated and radiolabelled in vitro before reinjection. A new technique is presented here that obviates the need for cell isolation by the direct intravenous injection of a granulocyte specific 123I labelled monoclonal antibody. In this publication the basic parameters of the antibody granulocyte interaction are described. Antibody binding does not inhibit vital functions of the granulocytes, such as chemotaxis and superoxide generation. Scatchard analysis of binding data reveals an apparent affinity of the antibody for granulocytes of 6.8 X 10(9) l/mol and approximately 7.1 X 10(4) binding sites per cell. Due to the high specificity of the antibody, the only expected interference is from CEA producing tumors.