75 resultados para Semiconductor doping, Neutron transmutation.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This article presents a psychological approach to substance use in sport using a dynamic and situated activity framework. The aim was to analyze the various relationships between activity and the consumption of substances during the sporting life course of athletes who recognized doping violation. Design Data were collected from secondary sources and biographical and self-confrontational interviews to build traces of the past activity. Method Twelve doping athletes or those admitting to having used banned substances volunteered to participate. The data were coded and compared to identify typical activities and their intrinsic dynamics. Results Six activities were identified: "Agree to use," "Drop out of a non-viable state," Return to a former state," "Prevent a potential deficiency," "Maintain an acquired state," and "Balance the sporting life with substance use," comprising 11 patterns. Conclusions The athletes' activity embedded substance use in reciprocal relationships that consisted of freezing, exploring and exploiting fields of possible actions created and offered by the situation dynamics. Recommendations for situated and dynamic prevention are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questionnaires are used in the majority of the studies ondoping prevalence in sport. Nevertheless, prevalence is noteasy to evaluate and previous epidemiologic studies demonstrateda wide variance. This variance has mostly beenexplained by sample differences. The way to evaluate dopingprevalence in the survey is questioned in this paper. Aquestionnaire was administered to 1810 amateur athletes(993 males, 817 females). Doping use was ascertained invarious ways, using different definitions of doping and typesof question in the survey. Depending on the definition ofdoping and the type of question used, the prevalence ofdoping obtained can differ enormously, between 1.3 and39.2% of athletes. Marijuana and drugs for asthma were thetwo banned substances most used. The majority of athletesoften ignored the banned list and did not use prohibitedsubstances to dope. Using various ways to question athletes,observing the usage of substances, cross checking the data,taking into account the aim of substances uses and thevarious definitions of doping are necessary to give morereliable prevalence of doping. Moreover, doping at anamateur level seems to be less of a sport problem than asocial problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today's approach to anti-doping is mostly centered on the judicial process, despite pursuing a further goal in the detection, reduction, solving and/or prevention of doping. Similarly to decision-making in the area of law enforcement feeding on Forensic Intelligence, anti-doping might significantly benefit from a more extensive gathering of knowledge. Forensic Intelligence might bring a broader logical dimension to the interpretation of data on doping activities for a more future-oriented and comprehensive approach instead of the traditional case-based and reactive process. Information coming from a variety of sources related to doping, whether directly or potentially, would feed an organized memory to provide real time intelligence on the size, seriousness and evolution of the phenomenon. Due to the complexity of doping, integrating analytical chemical results and longitudinal monitoring of biomarkers with physiological, epidemiological, sociological or circumstantial information might provide a logical framework enabling fit for purpose decision-making. Therefore, Anti-Doping Intelligence might prove efficient at providing a more proactive response to any potential or emerging doping phenomenon or to address existing problems with innovative actions or/and policies. This approach might prove useful to detect, neutralize, disrupt and/or prevent organized doping or the trafficking of doping agents, as well as helping to refine the targeting of athletes or teams. In addition, such an intelligence-led methodology would serve to address doping offenses in the absence of adverse analytical chemical evidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An intercomparison of the response of different photon and neutron detectors was performed in several measurement positions around a spent fuel cask (type TN 12/2B) filled with 4 MOX and 8 UO2 15 x 15 PWR fuel assemblies at the nuclear power plant Gosgen (KKG) in Switzerland. The instruments used in the study were both active and passive, photon and neutron detectors calibrated either for ambient or personal dose equivalent. The aim of the measurement campaign was to compare the responses of the radiation instruments to routinely used detectors. It has been shown that especially the indications of the neutron detectors are strongly dependent on the neutron spectra around the cask due to their different energy responses. However, routinely used active photon and neutron detectors were shown to be reliable instruments. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: All kinds of blood manipulations aim to increase the total hemoglobin mass (tHb-mass). To establish tHb-mass as an effective screening parameter for detecting blood doping, the knowledge of its normal variation over time is necessary. The aim of the present study, therefore, was to determine the intraindividual variance of tHb-mass in elite athletes during a training year emphasizing off, training, and race seasons at sea level. METHODS: tHb-mass and hemoglobin concentration ([Hb]) were determined in 24 endurance athletes five times during a year and were compared with a control group (n = 6). An analysis of covariance was used to test the effects of training phases, age, gender, competition level, body mass, and training volume. Three error models, based on 1) a total percentage error of measurement, 2) the combination of a typical percentage error (TE) of analytical origin with an absolute SD of biological origin, and 3) between-subject and within-subject variance components as obtained by an analysis of variance, were tested. RESULTS: In addition to the expected influence of performance status, the main results were that the effects of training volume (P = 0.20) and training phases (P = 0.81) on tHb-mass were not significant. We found that within-subject variations mainly have an analytical origin (TE approximately 1.4%) and a very small SD (7.5 g) of biological origin. CONCLUSION: tHb-mass shows very low individual oscillations during a training year (<6%), and these oscillations are below the expected changes in tHb-mass due to Herythropoetin (EPO) application or blood infusion (approximately 10%). The high stability of tHb-mass over a period of 1 year suggests that it should be included in an athlete's biological passport and analyzed by recently developed probabilistic inference techniques that define subject-based reference ranges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a method for the analysis of urinary 16(5alpha)-androsten-3alpha-ol together with 5beta-pregnane-3alpha,20alpha-diol and four testosterone metabolites: androsterone (Andro), etiocholanolone (Etio), 5alpha-androstane-3alpha,17beta-diol (5alphaA), 5beta-androstane-3alpha,17beta-diol (5betaA) by means of gas chromatography/combustion/isotopic ratio mass spectrometry (GC/C/IRMS). The within-assay and between-assay precision S.D.s of the investigated steroids were lower than 0.3 and 0.6 per thousand, respectively. A comparative study on a population composed of 20 subjects has shown that the differences of the intra-individual delta(13)C-values for 16(5alpha)-androsten-3alpha-ol and 5beta-pregnane-3alpha,20alpha-diol are less than 0.9 per thousand. Thereafter, the method has been applied in the frame of an excretion study following oral ingestion of 50 mg DHEA initially and oral ingestion of 50mg pregnenolone 48 h later. Our findings show that administration of DHEA does not affect the isotopic ratio values of 16(5alpha)-androsten-3alpha-ol and 5beta-pregnane-3alpha,20alpha-diol, whereas the isotopic ratio values of 5beta-pregnane-3alpha,20alpha-diol vary by more 5 per thousand upon ingestion of pregnenolone. We have observed delta(13)C-value changes lower than 1 per thousand for 16(5alpha)-androsten-3alpha-ol, though pregnenolone is a precursor of the 16-ene steroids. In contrast to 5beta-pregnane-3alpha,20alpha-diol, the 16-ene steroid may be used as an endogenous reference compound when pregnenolone is administered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemoglobin concentration is one of the principal factors of aerobic power and, consequently, of performance in many types of physical activities. The use of recombinant human erythropoietin is, therefore, particularly powerful for improving the physical performances of patients, and, more generally, improving their quality of life. This article discusses procedures for monitoring recombinant erythropoietin and its analogues in doping for athletic performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stimulation of erythropoiesis is one of the most efficient ways of doping. This type of doping is advantageous for aerobic physical exercise and of particular interest to endurance athletes. Erythropoiesis, which takes place in bone marrow, is under the control of EPO, a hormone secreted primarily by the kidneys when the arterial oxygen tension decreases. In certain pathological disorders, such as chronic renal failure, the production of EPO is insufficient and results in anemia. The pharmaceutical industry has, thus, been very interested in developing drugs that stimulate erythropoiesis. With this aim, various strategies have been, and continue to be, envisaged, giving rise to an expanding range of drugs that are good candidates for doping. Anti-doping control has had to deal with this situation by developing appropriate methods for their detection. This article presents an overview of both the drugs and the corresponding methods of detection, and thus follows a roughly chronological order.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their performance enhancing properties, use of anabolic steroids (e.g. testosterone, nandrolone, etc.) is banned in elite sports. Therefore, doping control laboratories accredited by the World Anti-Doping Agency (WADA) screen among others for these prohibited substances in urine. It is particularly challenging to detect misuse with naturally occurring anabolic steroids such as testosterone (T), which is a popular ergogenic agent in sports and society. To screen for misuse with these compounds, drug testing laboratories monitor the urinary concentrations of endogenous steroid metabolites and their ratios, which constitute the steroid profile and compare them with reference ranges to detect unnaturally high values. However, the interpretation of the steroid profile is difficult due to large inter-individual variances, various confounding factors and different endogenous steroids marketed that influence the steroid profile in various ways. A support vector machine (SVM) algorithm was developed to statistically evaluate urinary steroid profiles composed of an extended range of steroid profile metabolites. This model makes the interpretation of the analytical data in the quest for deviating steroid profiles feasible and shows its versatility towards different kinds of misused endogenous steroids. The SVM model outperforms the current biomarkers with respect to detection sensitivity and accuracy, particularly when it is coupled to individual data as stored in the Athlete Biological Passport.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

C.E.R.A. (Continuous Erythropoietin Receptor Activator) is a new third-generation erythropoiesis-stimulating agent that has recently been linked with abuse in endurance sports. The anti-doping community rapidly reacted by releasing a high-throughput screening ELISA allowing the detection of C.E.R.A. doping in athletes' blood. In order to return adverse analytical findings, anti-doping laboratories, however, need, as far as possible, to confirm the presence of the drug in athletes' samples through orthogonal methods. This article focuses on the comparison of 2 proposed confirmation assays based on gel electrophoresis that were coupled with a new sample immunopurification method. IEF, the classical method used to target erythropoietin (EPO) and its recombinant analogues in athletes' samples, and SARKOSYL-PAGE were applied to the plasma samples of subjects having received a single injection of C.E.R.A. It was demonstrated that SARKOSYL-PAGE was at least 6 times more sensitive than IEF, with comparable specificity. A longer detection window coupled with easier interpretation criteria led us to recommend the use of SARKOSYL-PAGE to confirm C.E.R.A. presence in athletes' blood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Big sports events like the 2008 European Football Championship are a challenge for anti-doping activities, particularly when the sports event is hosted by two different countries and there are two laboratories accredited by the World Anti-Doping Agency. This challenges the logistics of sample collection as well as the chemical analyses, which must be carried out timeously. The following paper discusses the handling of whereabouts information for each athlete and the therapeutic use exemption system, experiences in sample collection and transportation of blood and urine samples, and the results of the chemical analysis in two different accredited laboratories. An overview of the analytical results of blood profiling and growth hormone testing in comparison with the distribution of the normal population is also presented.