67 resultados para Sage grouse.
Resumo:
BACKGROUND: We estimated the heritability of three measures of glomerular filtration rate (GFR) in hypertensive families of African descent in the Seychelles (Indian Ocean). METHODS: Families with at least two hypertensive siblings and an average of two normotensive siblings were identified through a national hypertension register. Using the ASSOC program in SAGE (Statistical Analysis in Genetic Epidemiology), the age- and gender-adjusted narrow sense heritability of GFR was estimated by maximum likelihood assuming multivariate normality after power transformation. ASSOC can calculate the additive polygenic component of the variance of a trait from pedigree data in the presence of other familial correlations. The effects of body mass index (BMI), blood pressure, natriuresis, along with sodium to potassium ratio in urine and diabetes, were also tested as covariates. RESULTS: Inulin clearance, 24-hour creatinine clearance, and GFR based on the Cockcroft-Gault formula were available for 348 persons from 66 pedigrees. The age- and gender-adjusted correlations (+/- SE) were 0.51 (+/- 0.04) between inulin clearance and creatinine clearance, 0.53 (+/- 0.04) between inulin clearance and Cockcroft-Gault formula and 0.66 (+/- 0.03) between creatinine clearance and Cockcroft-Gault formula. The age- and gender-adjusted heritabilities (+/- SE) of GFR were 0.41 (+/- 0.10) for inulin clearance, 0.52 (+/- 0.13) for creatinine clearance, and 0.82 (+/- 0.09) for Cockcroft-Gault formula. Adjustment for BMI slightly lowered the correlations and heritabilities for all measurements whereas adjustment for blood pressure had virtually no effect. CONCLUSION: The significant heritability estimates of GFR in our sample of families of African descent confirm the familial aggregation of this trait and justify further analyses aimed at discovering genetic determinants of GFR.
Resumo:
With contributions from leading authors in the most important areas of current research, this book provides insight into the streams that are driving leadership theory and practice today. The Nature of Leadership, Second Edition provides students with an updated and complete yet concise handbook that solidifies and integrates the vast and disparate leadership literature.Key Features of the Second Edition· Provides contributions from twenty-three subject-matter experts-ranging from the eminent to the up-and-coming-giving students an unsurpassed breadth of knowledge and perspective· Organizes the material into the three key thematic areas of Leadership-Science, Nature, and Nurture; the Major Schools of Leadership; and Leadership and Special Domains· Includes nine brand new chapters that provide students with the state-of-the-art of leadership theory and practice such as evolutionary and biological perspectives, individual differences, and shared leadership· Updates the content of seven retained chapters, with reference to recent research and developments in the field· Adds pedagogical features, including discussion questions, a list of practice-focused supplemental readings, and references to case studies
Resumo:
Next-generation sequencing offers an unprecedented opportunity to jointly analyze cellular and viral transcriptional activity without prerequisite knowledge of the nature of the transcripts. SupT1 cells were infected with a vesicular stomatitis virus G envelope protein (VSV-G)-pseudotyped HIV vector. At 24 h postinfection, both cellular and viral transcriptomes were analyzed by serial analysis of gene expression followed by high-throughput sequencing (SAGE-Seq). Read mapping resulted in 33 to 44 million tags aligning with the human transcriptome and 0.23 to 0.25 million tags aligning with the genome of the HIV-1 vector. Thus, at peak infection, 1 transcript in 143 is of viral origin (0.7%), including a small component of antisense viral transcription. Of the detected cellular transcripts, 826 (2.3%) were differentially expressed between mock- and HIV-infected samples. The approach also assessed whether HIV-1 infection modulates the expression of repetitive elements or endogenous retroviruses. We observed very active transcription of these elements, with 1 transcript in 237 being of such origin, corresponding on average to 123,123 reads in mock-infected samples (0.40%) and 129,149 reads in HIV-1-infected samples (0.45%) mapping to the genomic Repbase repository. This analysis highlights key details in the generation and interpretation of high-throughput data in the setting of HIV-1 cellular infection.
Resumo:
Background and Aims: Discriminating irritable bowel syndrome (IBS) from inflammatorybowel disease (IBD) can be a clinical challenge as symptoms can overlap. We and othershave recently shown that fecal calprotectin (FC) is more accurate for discriminating IBSfrom IBD compared to C-reactive protein (CRP) and blood leukocytes. Data on the biomarkersused in daily gastroenterological practice are lacking. We therefore aimed to assess whichbiomarkers are used by gastroenterologists in their daily practice for discriminating IBSfrom IBD.Methods: A questionnaire was sent to all board certified gastroenterologists inSwitzerland focusing on demographic informations, number of IBS patients treated in thetime period from May 2009 to April 2010, and the specific biomarkers evaluated fordiscriminating IBS from IBD.Results: Response rate was 57% (153/270). Mean physician'sage was 50±9years, mean duration of gastroenterologic practice 14±8years, 52% of themwere working in private practice and 48% in hospitals. Thirty-nine percent had taken careof more than 100 IBS patients in the last 12 months, 37% had seen 41-100 and 24% hadseen 1-40 IBS patients. Gastroenterologists in private practice more frequently took care ofat least 40 IBS patients in a year compared to hospital-based gastroenterologists (P<0.001).The following biomarkers were determined for discriminating IBS from IBD: CRP 100%,FC 79%, hematogram (red blood cells and leukocytes) 70%, iron status (ferritin, transferrinsaturation) 59%, erythrocyte sedimentation rate 2.7%, protein electrophoresis 0.7%, andalpha-1 antitrypsin clearance 0.7%. There was a trend for using FC more often in privatepractice than in hospital (P = 0.08). Twenty-four percent of gastroenterologists had usedFC in the workup of more than 70% of patients classified as IBS, 22% had used FC in 30-70% of IBS patients, 39% in less than 30%, and 15% had never used FC for the work-upof suspected IBS. Eighty-nine percent of gastroenterologists considered FC to be superiorto CRP for discriminating IBS from IBD, 87% thought that patient's compliance for fecalsampling is high, and 51% judged the fee of USD 60 for a FC test as appropriate.Conclusions:FC is widely used in clinical practice to discriminate IBS from IBD. In accordance with thescientific evidence, the majority of gastroenterologists consider FC to be more accurate thanCRP for discriminating IBS from IBD. Gastroenterologists in private practice take care ofsignificantly more IBS patients than colleagues in hospital.
Resumo:
Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.