62 resultados para SURFACE-PROPERTIES
Resumo:
The aim of this study was to evaluate the combination of abdominoplasty with liposuction of both flanks with regards to length of scar, complications, and patient's satisfaction. A retrospective analysis of 35 patients who underwent esthetic abdominoplasty at our institution between 2002 and 2004 was performed. Thirteen patients underwent abdominoplasty with liposuction of both flanks, 22 patients underwent conventional abdominoplasty. Liposuction of the flanks did not increase the rate of complications of the abdominoplasty procedures. We found a tendency toward shorter scars in patients who underwent abdominoplasty combined with liposuction of the flanks. Implementation of 3-dimensional laser surface scanning to objectify the postoperative outcomes, documented a comparable degree of flatness of the achieved body contouring in both procedures. 3-dimensional laser surface scanning can be a valuable tool to objectify assessment of postoperative results.
Resumo:
Biofilm formation is a multi-step process influenced by surface properties. We investigated early and mature biofilm of Staphylococcus aureus on 4 different biological calcium phosphate (CaP) bone grafts used for filling bone defects. We investigated standardised cylinders of fresh and fresh-frozen human bone grafts were harvested from femoral heads; processed humanand bovine bone grafts were obtained preformed. Biofilm formation was done in tryptic soy broth (TSB) using S. aureus (ATCC 29213) with static conditions. Biofilm density after 3 h (early biofilm) and 24 h (mature biofilm) was investigated by sonication and microcalorimetry. After 3 h, bacterial density was highest on fresh-frozenandfresh bone grafts. After 24 h, biofilm density was lowest on freshbone grafts (p < 0.001) compared to the other 3 materials, which did not differ quantitatively (p > 0.05). The lowest increase in bacterial density was detected on fresh bone grafts (p < 0.001). Despite normal shaped colonies, we found additional small colonies on the surface of the fresh and fresh-frozen samples by sonication. This was also apparent in microcalorimetric heat-flow curves. The four investigated CaP bone grafts showed minor structural differences in architecture but marked differences concerning serum coverage and the content of bone marrow, fibrous tissue and bone cells. These variations resulted in a decreased biofilm density on freshand fresh-frozenbone grafts after 24 h, despite an increased early biofilm formation and might also be responsible for the variations in colony morphology (small colonies). Detection of small colony variants by microcalorimetry might be a new approach to improve the understanding of biofilm formation.
Resumo:
Serine repeat antigen 5 (SERA5) is an abundant antigen of the human malaria parasite Plasmodium falciparum and is the most strongly expressed member of the nine-gene SERA family. It appears to be essential for the maintenance of the erythrocytic cycle, unlike a number of other members of this family, and has been implicated in parasite egress and/or erythrocyte invasion. All SERA proteins possess a central domain that has homology to papain except in the case of SERA5 (and some other SERAs), where the active site cysteine has been replaced with a serine. To investigate if this domain retains catalytic activity, we expressed, purified, and refolded a recombinant form of the SERA5 enzyme domain. This protein possessed chymotrypsin-like proteolytic activity as it processed substrates downstream of aromatic residues, and its activity was reversed by the serine protease inhibitor 3,4-diisocoumarin. Although all Plasmodium SERA enzyme domain sequences share considerable homology, phylogenetic studies revealed two distinct clusters across the genus, separated according to whether they possess an active site serine or cysteine. All Plasmodia appear to have at least one member of each group. Consistent with separate biological roles for members of these two clusters, molecular modeling studies revealed that SERA5 and SERA6 enzyme domains have dramatically different surface properties, although both have a characteristic papain-like fold, catalytic cleft, and an appropriately positioned catalytic triad. This study provides impetus for the examination of SERA5 as a target for antimalarial drug design.
Resumo:
A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.
Resumo:
Mechanically ventilated patients in hospitals are subjected to an increased risk of acquiring nosocomial pneumonia that sometimes has a lethal outcome. One way to minimize the risk could be to make the surfaces on endotracheal tubes antibacterial. In this study, bacterial growth was inhibited or completely prevented by silver ions wet chemically and deposited onto the tube surface. Through the wet chemical treatment developed here, a surface precipitate was formed containing silver chloride and a silver stearate salt. The identity and morphology of the surface precipitate was studied using x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, and x-ray powder diffraction. Leaching of silver ions into solution was examined, and bacterial growth on the treated surfaces was assayed using Pseudomonas aeruginosa wild type (PAO1) bacteria. Furthermore, the minimum inhibitory concentration of silver ions was determined in liquid- and solid-rich growth medium as 23 and 18 microM, respectively, for P. aeruginosa.
Resumo:
The in situ deposition of zinc oxide on gold nanoparticles in aqueous solution has been here successfully applied in the field of fingermark detection on various non-porous surfaces. In this article, we present the improvement of the multimetal deposition, an existing technique limited up to now to non-luminescent results, by obtaining luminescent fingermarks with very good contrast and details. This is seen as a major improvement in the field in terms of selectivity and sensitivity of detection, especially on black surfaces.
Resumo:
OBJECTIVES: To carry out a meta-analysis in order to assess the influencing factors on retention loss and marginal discoloration of cervical restorations made of composites and glass ionomer (derivates). METHODS: The literature was searched for prospective clinical studies on cervical restorations with an observation period of at least 18 months. RESULTS: Fifty clinical studies involving 40 adhesive systems matched the inclusion criteria. On average, 10% of the cervical fillings were lost and 24% exhibited marginal discoloration after 3 years. The variability ranged from 0% to 50% for retention loss and from 0% to 74% for marginal discoloration. Hardly any secondary caries was detected. When linear mixed models with a study and experiment effect were used, the analysis revealed that the adhesive/restorative class had the most significant influence, with 2-step self-etching adhesive systems performing best and 1-step self-etching adhesive systems performing worst; 3-step etch-and-rinse systems, glass ionomers/resin-modified glass ionomers, 2-step etch-and-rinse systems and polyacid-modified resin composites were ranked in between. Restorations placed in teeth whose dentin/enamel had been prepared/roughened showed a statistically significant higher retention rate than those placed in teeth with unprepared dentin (p<0.05). Beveling of the enamel and the type of isolation used (rubberdam/cotton rolls) had no significant influence. SIGNIFICANCE: The clinical performance of cervical restorations is significantly influenced by the type of adhesive system used and/or the adhesive class to which the system belonged and whether the dentin/enamel is prepared or not. 2-Step self-etching- and 3-step etch&rinse systems shall be chosen over 1-step self-etching systems and glass ionomer derivates. The dentin (and enamel) surface shall be roughened before placement of the restoration.
Resumo:
Central to the biological function of microtubules is their ability to modify their length which occurs by addition and removal of subunits at the ends of the polymer, both in vivo and in vitro. This dynamic behavior is strongly influenced by temperature. Here, we show that the lateral interaction between tubulin subunits forming microtubule is strongly temperature dependent. Microtubules deposited on prefabricated substrates were deformed in an atomic force microscope during imaging, in two different experimental geometries. Microtubules were modeled as anisotropic, with the Young's modulus corresponding to the resistance of protofilaments to stretching and the shear modulus describing the weak interaction between the protofilaments. Measurements involving radial compression of microtubules deposited on flat mica confirm that microtubule elasticity depends on the temperature. Bending measurements performed on microtubules deposited on lithographically fabricated substrates show that this temperature dependence is due to changing shear modulus, implying that the lateral interaction between the protofilaments is strongly determined by the temperature. These measurements are in good agreement with previously reported measurements of the disassembly rate of microtubules, demonstrating that the mechanical and dynamic properties of microtubules are closely related.
Resumo:
A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.
Resumo:
Great effort is put into developing reliable, predictive, high-throughput, and low-cost screening approaches for the toxicity evaluation of ambient and manufactured nanoparticles (NP). These tests often consider oxidative reactivity, as oxidative stress is a well-documented pathway in particle toxicology. Based on a panel of six carbonaceous and five metal/metal oxide (Me/MeOx) nanoparticles, we: (i) compared the specifications (linearity, detection limits, repeatability) of three acellular reactivity tests using either dithiothreitol (DTT assay), dichlorofluorescein (DCFH assay), or ascorbic acid (AA-assay) as the reducing agent; and (ii) evaluated which physicochemical properties were important for explaining the observed reactivity. The selected AA assay was found to be neither sensitive nor robust enough to be retained. For the other tests, the surface properties of carbonaceous NP were of utmost importance for explaining their reactivity. In particular, the presence of "strongly reducing" surface functions explained most of its DCFH reactivity and a large part of its DTT reactivity. For the selected Me/MeOx, a different picture emerged. Whereas all particles were able to oxidize DCFH, dissolution and complexation processes could additionally influence the measured reactivity, as observed using the DTT assay. This study suggests that a combination of the DTT and DCFH assays provides complementary information relative to the quantification of the oxidative capacity of NP.
Resumo:
Cyclosporine A (CsA) has been demonstrated to be effective for the treatment of a variety of ophthalmological conditions, including ocular surface disorders such as the dry eye disease (DED). Since CsA is characterised by its low water solubility, the development of a topical ophthalmic formulation represents an interesting pharmaceutical question. In the present study, two different strategies to address this challenge were studied and compared: (i) a water-soluble CsA prodrug formulated within an aqueous solution and (ii) a CsA oil-in-water emulsion (Restasis, Allergan Inc., Irvine, CA). First, the prodrug formulation was shown to have an excellent ocular tolerance as well as no influence on the basal tear production; maintaining the ocular surface properties remained unchanged. Then, in order to allow in vivo investigations, a specific analytical method based on ultra high pressure liquid chromatography coupled with triple quadrupole mass spectrometer (UHPLC-MS/MS) was developed and optimised to quantify CsA in ocular tissues and fluids. The CsA ocular kinetics in lachrymal fluid for both formulations were found to be similar between 15 min and 48 h. The CsA ocular distribution study evidenced the ability of the prodrug formulation to penetrate into the eye, achieving therapeutically active CsA levels in tissues of both the anterior and posterior segments. In addition, the detailed analysis of the in vivo data using a bicompartmental model pointed out a higher bioavailability and lower elimination rate for CsA when it is generated from the prodrug than after direct application as an emulsion. The interesting in vivo properties displayed by the prodrug solution make it a safe and suitable option for the treatment of DED.
Resumo:
A Knudsen flow reactor has been used to quantify functional groups on the surface of seven different types of combustion particle samples: 3 amorphous carbons (FS 101, Printex 60, FW 2), 2 flame soots (hexane soot generated from a rich and a lean diffusion flame), and 2 Diesel particles (SRM 2975, Diesel soot recovered from a Diesel particulate filter). The technique is based on a heterogeneous titration reaction between a probe gas and a specific functional group on the particle surface. Six probe gases have been selected for the quantification of important functional groups: N(CH3)3 for the titration of acidic sites, NH2OH for carbonyl functions of aldehydes and ketones, CF3COOH and HCl for basic sites of different strength, O3 and NO2 for oxidizable groups. The limit of detection was generally well below 1% of a formal monolayer of adsorbed probe gas. Results obtained with N(CH3)3 were higher for the FW 2 amorphous carbon (post-oxidized sample, according to the manufacturer) and the Diesel particles (between 5.2·10 13 and 5.8·10 13 molecule/cm2), indicating a higher state of oxidation than for the other samples (between 1.3·10 12 and 3.7·10 12 molecule/cm2). The ratio of uptakes of CF3COOH and HCl inferred the presence of basic oxides on the particle surface, owing to the larger stability of the acetate compared to the chloride counter ion in the resulting pyrylium salt. The reactivity of the FS 101 amorphous carbon (3.7·10 15 molecule/cm2) and the hexane flame soot (between 1.9·10 15 and 2.7·10 15 molecule/cm2) towards O3 was very high, indicating the presence of a huge amount of oxidizable or reduced groups on the surface of these samples. Besides the quantification of surface functional groups, the kinetics of reactions between particles and probe gases has also been studied. The uptake coefficient γ0 was roughly correlated with the amount of probe gas taken up by the samples. Indeed, the presence of a high density of functional groups led to fast uptake of the probe gas. These different findings indicate that the particle surface appeared multi-functional, with the simultaneous presence of antagonistic functional groups which do not undergo internal chemical reactions, such as acid-base neutralization. Results also point to important differences in the surface reactivity of the samples, depending on the combustion conditions. The relative distribution of the surface functional groups may be a useful indicator for the state of oxidation and the reactivity of the particle surface.
Resumo:
We present a silicon chip-based approach for the enhanced sensitivity detection of surface-immobilized fluorescent molecules. Green fluorescent protein (GFP) is bound to the silicon substrate by a disuccinimidyl terephtalate-aminosilane immobilization procedure. The immobilized organic layers are characterized by surface analysis techniques, like ellipsometry, atomic force microscopy (AFM) and X-ray induced photoelectron spectroscopy. We obtain a 20-fold enhancement of the fluorescent signal, using constructive interference effects in a fused silica dielectric layer, deposited before immobilization onto the silicon. Our method opens perspectives to increase by an order of magnitude the fluorescent response of surface immobilized DNA- or protein-based layers for a variety of biosensor applications.
Evaluation in vitro de la réactivité des particules fines et ultrafines : rapport scientifique final
Resumo:
Une des percées les plus importantes dans la recherche sur les nanoparticules (ambiantes et manufacturées) a été la reconnaissance de leur potentiel à générer un stress oxydatif au niveau cellulaire. Dans cette optique, la mesure du potentiel oxydant intrinsèque des particules pourrait présenter une première étape dans l'évaluation des dangers. Ce projet méthodologique avait pour but de caractériser le potentiel oxydant de différentes nanoparticules « modèles » (ambiantes et manufacturées) au moyen de trois tests acellulaires (Test DTT, Test DCFH, Test oxymétrique) et d'utiliser ces résultats pour proposer une méthode de « référence ». D'autre part, nous avons appliqué la méthode sélectionnée à deux cas (exposition d'ouvriers à des particules de combustion et évaluation du danger de différentes nanoparticules manufacturées) afin de déterminer quels sont les paramètres qui influencent la mesure. Les résultats obtenus indiquent que la préparation des suspensions joue un rôle dans la mesure de ce potentiel oxydant. La réactivité dépend de la concentration du surfactant et de la durée de sonication. D'autre part, l'ordre de réactivité est dépendant de la métrique utilisée (masse ou surface) pour exprimer les résultats. Parmi les trois tests considérés, le test DTT pourrait être le plus utile pour effectuer une évaluation initiale du danger potentiel de nanoparticules ambiantes ou manufacturées. Ce test pourrait être intégré dans une stratégie d'évaluation de la toxicité des nanoparticules. Le test DTT correspond bien un test intégratif. Pour des situations de travail dans lesquelles les particules de combustion sont majoritaires, les paramètres physico-chimiques qui corrèlent de manière significative avec la réactivité DTT sont la surface des particules, les concentrations de carbone organique, la somme des concentrations de quatre quinones et les concentrations de fer et cuivre. Un nombre plus faible de corrélations est observé dans des ateliers mécaniques, suggérant que d'autres composés non mesurés interviennent également dans cette réactivité. Concernant les nanoparticules carbonées manufacturées, les fonctions chimiques de surface corrélées avec la réactivité DTT sont des fonctions acides et des fonctions inconnues pouvant dismuter. D'autre part, la solubilité et la possibilité de former des complexes avec le DTT sur la surface des NP manufacturées influencent le résultat de réactivité.