77 resultados para SPME-GC-MS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

For more than a decade scientists tried to develop methods capable of dating ink by monitoring the loss of phenoxyethanol (PE) over time. While many methods were proposed in the literature, few were really used to solve practical cases and they still raise much concern within the scientific community. In fact, due to the complexity of ink drying processes it is particularly difficult to find a reliable ageing parameter to reproducibly follow ink ageing. Moreover, systematic experiments are required in order to evaluate how different factors actually influence the results over time. Therefore, this work aimed at evaluating the capacity of four different ageing parameters to reliably follow ink ageing over time: (1) the quantity of solvent PE in an ink line, (2) the relative peak area (RPA) normalising the PE results using stable volatile compounds present in the ink formulation, (3) the solvent loss ratio (R%) calculated from PE results obtained by the analyses of naturally and artificially aged samples, (4) a modified solvent loss ratio version (R%*) calculated from RPA results. After the determination of the limits of reliable measurements of the analytical method, the repeatability of the different ageing parameters was evaluated over time, as well as the influence of ink composition, writing pressure and storage conditions on the results. Surprisingly, our results showed that R% was not the most reliable parameter, as it showed the highest standard deviation. Discussion of the results in an ink dating perspective suggests that other proposed parameters, such as RPA values, may be more adequate to follow ink ageing over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For more than a decade scientists tried to develop methods capable of dating ink by monitoring the loss of phenoxyethanol (PE) over time. While many methods were proposed in the literature, few were really used to solve practical cases and they still raise much concern within the scientific community. In fact, due to the complexity of ink drying processes it is particularly difficult to find a reliable ageing parameter to reproducibly follow ink ageing. Moreover, systematic experiments are required in order to evaluate how different factors actually influence the results over time. Therefore, this work aimed at evaluating the capacity of four different ageing parameters to reliably follow ink ageing over time: (1) the quantity of solvent PE in an ink line, (2) the relative peak area (RPA) normalising the PE results using stable volatile compounds present in the ink formulation, (3) the solvent loss ratio (R%) calculated from PE results obtained by the analyses of naturally and artificially aged samples, (4) a modified solvent loss ratio version (R%*) calculated from RPA results. After the determination of the limits of reliable measurements of the analytical method, the repeatability of the different ageing parameters was evaluated over time, as well as the influence of ink composition, writing pressure and storage conditions on the results. Surprisingly, our results showed that R% was not the most reliable parameter, as it showed the highest standard deviation. Discussion of the results in an ink dating perspective suggests that other proposed parameters, such as RPA values, may be more adequate to follow ink ageing over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estimating the time since the last discharge of firearms and/or spent cartridges may be a useful piece of information in forensic firearm-related cases. The current approach consists of studying the diffusion of selected volatile organic compounds (such as naphthalene) released during the shooting using solid phase micro-extraction (SPME). However, this technique works poorly on handgun car-tridges because the extracted quantities quickly fall below the limit of detection. In order to find more effective solutions and further investigate the aging of organic gunshot residue after the discharge of handgun cartridges, an extensive study was carried out in this work using a novel approach based on high capacity headspace sorptive extraction (HSSE). By adopting this technique, for the first time 51 gunshot residue (GSR) volatile organic compounds could be simultaneously detected from fired handgun cartridge cases. Application to aged specimens showed that many of those compounds presented significant and complementary aging profiles. Compound-to-compound ratios were also tested and proved to be beneficial both in reducing the variability of the aging curves and in enlarging the time window useful in a forensic casework perspective. The obtained results were thus particularly promising for the development of a new complete forensic dating methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comment l'analyse chimique des produits contrefaits peut-elle contribuer à mieux comprendre le phénomène de la contrefaçon?Pour appréhender cette question, une approche novatrice basée sur l'analyse par SPME GC-MS des composés volatils de trente-neuf bracelets parfumés présents sur des contrefaçons horlogères a été mise en oeuvre.La détection de plusieurs dizaines de composés par montre a permis de définir des profils chimiques discriminants. Au total, trois groupes de montres possédant des profils comparables ont été détectés. Ces groupes ont été mis en perspective de liens physiques détectés sur la base du marquage des bracelets (marques et logos) par la fédération de l'industrie horlogère suisse (FH) et des informations spatiotemporelles des saisies. Les montres provenant d'une même saisie présentent systématiquement des liens physiques, mais pas forcément des profils chimiques similaires. Il en ressort que les profils chimiques peuvent fournir une information complémentaire à l'analyse des marquages, qu'ils varient peu dans le temps et que des montres liées chimiquement sont retrouvées dans le monde entier. Cette étude exploratoire révèle ainsi le potentielle d'exploitation de techniques d'analyse complémentaires pour mieux comprendre les modes de production, voire de diffusion de la contrefaçon. Finalement, la méthode analytique a permis de détecter des composés de plastiques en sus des constituants de parfums. Ce résultat laisse entrevoir la possibilité d'exploiterla méthode pour une large gamme de produits contrefaits.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Determining the time since discharge of spent cartridges found on a crime scene may be very useful in firearm investigations. The potential of small calibre munitions was barely studied before and this work did therefore focus on that problematic. The first step was to optimize the detection potential of solidphase microextraction (SPME) followed by gas chromatography coupled to a mass spectrometry detector (GC/MS). This allowed determining the organic volatile composition of empty cartridges immediately after a gunshot. Identification of 32 detected compounds was confirmed by the analysis of reference substances. Preliminary aging studies over 32 hours were carried out on selected target compounds to evaluate their potential for the dating of shotguns.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simple non-targeted differential HPLC-APCI/MS approach has been developed in order to survey metabolome modifications that occur in the leaves of Arabidopsis thaliana following wound-induced stress. The wound-induced accumulation of metabolites, particularly oxylipins, was evaluated by HPLC-MS analysis of crude leaf extracts. A generic, rapid and reproducible pressure liquid extraction procedure was developed for the analysis of restricted leaf samples without the need for specific sample preparation. The presence of various oxylipins was determined by head-to-head comparison of the HPLC-MS data, filtered with a component detection algorithm, and automatically compared with the aid of software searching for small differences in similar HPLC-MS profiles. Repeatability was verified in several specimens belonging to different series. Wound-inducible jasmonates were efficiently highlighted by this non-targeted approach without the need for complex sample preparation as is the case for the 'oxylipin signature' procedure based on GC-MS. Furthermore this HPLC-MS screening technique allowed the isolation of induced compounds for further characterisation by capillary-scale NMR (CapNMR) after HPLC scale-up. In this paper, the screening method is described and applied to illustrate its potential for monitoring polar and non-polar stress-induced constituents as well as its use in combination with CapNMR for the structural assignment of wound-induced compounds of interest

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In forensic investigation of firearm-related cases, determination of the residual amount of volatile compounds remaining inside a cartridge could be useful in estimating the time since its discharge. Published approaches are based on following the decrease of selected target compounds as a function of time by using solid phase micro-extraction (SPME). Naphthalene, as well as an unidentified decomposition product of nitrocellulose (referred to as "TEA2"), are usually employed for this purpose. However, reliability can be brought into question given their high volatility and the low reproducibility of their extracted quantities. In order to identify alternatives and therefore develop improved dating methods, an extensive study on the composition and variability of volatile residues in nine different types of cartridges was carried out. Analysis was performed using headspace sorptive extraction (HSSE), which is a more exhaustive technique compared to SPME. 166 compounds were identified (several of which for the first time), and it was observed that the final compositional characteristics of each residue were strongly dependent on its source. Variability of single identified compounds within and between different types of cartridge, as well as their evolution over time, was also studied. Many explosion products containing up to 4 aromatic rings were found to be globally present in high proportions amongst residues. 27 of them (excluding naphthalene) also presented detectable decreases during the first 24 h. Therefore, they could be used as complementary target analytes in future dating methods.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The detection of testosterone abuse in sports is routinely achieved through the 'steroidal module' of the Athlete Biological Passport by GC-MS(/MS) quantification of selected endogenous anabolic androgenic steroids (EAAS) from athletes' urines. To overcome some limitations of the "urinary steroid profile" such as the presence of confounding factors (ethnicity, enzyme polymorphism, bacterial contamination, and ethanol), ultrahigh performance liquid chromatography (UHPLC) measurements of blood concentrations of testosterone, its major metabolites, and precursors could represent an interesting and complementary strategy. In this work, two UHPLC-MS/MS methods were developed for the quantification of testosterone and related compounds in human serum, including major progestogens, corticoids, and estrogens. The validated methods were then used for the analyses of serum samples collected from 19 healthy male volunteers after oral and transdermal testosterone administration. Results from unsupervised multiway analysis allowed variations of target analytes to be assessed simultaneously over a 96-h time period. Except for alteration of concentration values due to the circadian rhythm, which concerns mainly corticosteroids, DHEA, and progesterone, significant variations linked to the oral and transdermal testosterone administration were observed for testosterone, DHT, and androstenedione. As a second step of analysis, the longitudinal monitoring of these biomarkers using intra-individual thresholds showed, in comparison to urine, significant improvements in the detection of testosterone administration, especially for volunteers with del/del genotype for phase II UGT2B17 enzyme, not sensitive to the main urinary marker, T/E ratio. A substantial extension of the detection window after transdermal testosterone administration was also observed in serum matrix. The longitudinal follow-up proposed in this study represents a first example of 'blood steroid profile' in doping control analysis, which can be proposed in the future as a complement to the 'urinary module' for improving steroid abuse detection capabilities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work is focused on the development of a methodology for the use of chemical characteristic of tire traces to help answer the following question: "Is the offending tire at the origin of the trace found on the crime scene?". This methodology goes from the trace sampling on the road to statistical analysis of its chemical characteristics. Knowledge about the composition and manufacture of tread tires as well as a review of instrumental techniques used for the analysis of polymeric materials were studied to select, as an ansi vi cal technique for this research, pyrolysis coupled to a gas Chromatograph with a mass spectrometry detector (Py-GC/MS). An analytical method was developed and optimized to obtain the lowest variability between replicates of the same sample. Within-variability of the tread was evaluated regarding width and circumference with several samples taken from twelve tires of different brands and/or models. The variability within each of the treads (within-variability) and between the treads (between-variability) could be quantified. Different statistical methods have shown that within-variability is lower than between-variability, which helped differentiate these tires. Ten tire traces were produced with tires of different brands and/or models by braking tests. These traces have been adequately sampled using sheets of gelatine. Particles of each trace were analysed using the same methodology as for the tires at their origin. The general chemical profile of a trace or of a tire has been characterized by eighty-six compounds. Based on a statistical comparison of the chemical profiles obtained, it has been shown that a tire trace is not differentiable from the tire at its origin but is generally differentiable from tires that are not at its origin. Thereafter, a sample containing sixty tires was analysed to assess the discrimination potential of the developed methodology. The statistical results showed that most of the tires of different brands and models are differentiable. However, tires of the same brand and model with identical characteristics, such as country of manufacture, size and DOT number, are not differentiable. A model, based on a likelihood ratio approach, was chosen to evaluate the results of the comparisons between the chemical profiles of the traces and tires. The methodology developed was finally blindly tested using three simulated scenarios. Each scenario involved a trace of an unknown tire as well as two tires possibly at its origin. The correct results for the three scenarios were used to validate the developed methodology. The different steps of this work were useful to collect the required information to test and validate the underlying assumption that it is possible to help determine if an offending tire » or is not at the origin of a trace, by means of a statistical comparison of their chemical profile. This aid was formalized by a measure of the probative value of the evidence, which is represented by the chemical profile of the trace of the tire. - Ce travail s'est proposé de développer une méthodologie pour l'exploitation des caractéristiques chimiques des traces de pneumatiques dans le but d'aider à répondre à la question suivante : «Est-ce que le pneumatique incriminé est ou n'est pas à l'origine de la trace relevée sur les lieux ? ». Cette méthodologie s'est intéressée du prélèvement de la trace de pneumatique sur la chaussée à l'exploitation statistique de ses caractéristiques chimiques. L'acquisition de connaissances sur la composition et la fabrication de la bande de roulement des pneumatiques ainsi que la revue de techniques instrumentales utilisées pour l'analyse de matériaux polymériques ont permis de choisir, comme technique analytique pour la présente recherche, la pyrolyse couplée à un chromatographe en phase gazeuse avec un détecteur de spectrométrie de masse (Py-GC/MS). Une méthode analytique a été développée et optimisée afin d'obtenir la plus faible variabilité entre les réplicas d'un même échantillon. L'évaluation de l'intravariabilité de la bande de roulement a été entreprise dans sa largeur et sa circonférence à l'aide de plusieurs prélèvements effectués sur douze pneumatiques de marques et/ou modèles différents. La variabilité au sein de chacune des bandes de roulement (intravariabilité) ainsi qu'entre les bandes de roulement considérées (intervariabilité) a pu être quantifiée. Les différentes méthodes statistiques appliquées ont montré que l'intravariabilité est plus faible que l'intervariabilité, ce qui a permis de différencier ces pneumatiques. Dix traces de pneumatiques ont été produites à l'aide de pneumatiques de marques et/ou modèles différents en effectuant des tests de freinage. Ces traces ont pu être adéquatement prélevées à l'aide de feuilles de gélatine. Des particules de chaque trace ont été analysées selon la même méthodologie que pour les pneumatiques à leur origine. Le profil chimique général d'une trace de pneumatique ou d'un pneumatique a été caractérisé à l'aide de huitante-six composés. Sur la base de la comparaison statistique des profils chimiques obtenus, il a pu être montré qu'une trace de pneumatique n'est pas différenciable du pneumatique à son origine mais est, généralement, différenciable des pneumatiques qui ne sont pas à son origine. Par la suite, un échantillonnage comprenant soixante pneumatiques a été analysé afin d'évaluer le potentiel de discrimination de la méthodologie développée. Les méthodes statistiques appliquées ont mis en évidence que des pneumatiques de marques et modèles différents sont, majoritairement, différenciables entre eux. La méthodologie développée présente ainsi un bon potentiel de discrimination. Toutefois, des pneumatiques de la même marque et du même modèle qui présentent des caractéristiques PTD (i.e. pays de fabrication, taille et numéro DOT) identiques ne sont pas différenciables. Un modèle d'évaluation, basé sur une approche dite du likelihood ratio, a été adopté pour apporter une signification au résultat des comparaisons entre les profils chimiques des traces et des pneumatiques. La méthodologie mise en place a finalement été testée à l'aveugle à l'aide de la simulation de trois scénarios. Chaque scénario impliquait une trace de pneumatique inconnue et deux pneumatiques suspectés d'être à l'origine de cette trace. Les résultats corrects obtenus pour les trois scénarios ont permis de valider la méthodologie développée. Les différentes étapes de ce travail ont permis d'acquérir les informations nécessaires au test et à la validation de l'hypothèse fondamentale selon laquelle il est possible d'aider à déterminer si un pneumatique incriminé est ou n'est pas à l'origine d'une trace, par le biais d'une comparaison statistique de leur profil chimique. Cette aide a été formalisée par une mesure de la force probante de l'indice, qui est représenté par le profil chimique de la trace de pneumatique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Limited information is available regarding the methodology required to characterize hashish seizures for assessing the presence or the absence of a chemical link between two seizures. This casework report presents the methodology applied for assessing that two different police seizures were coming from the same block before this latter one was split. The chemical signature was extracted using GC-MS analysis and the implemented methodology consists in a study of intra- and inter-variability distributions based on the measurement of the chemical profiles similarity using a number of hashish seizures and the calculation of the Pearson correlation coefficient. Different statistical scenarios (i.e., a combination of data pretreatment techniques and selection of target compounds) were tested to find the most discriminating one. Seven compounds showing high discrimination capabilities were selected on which a specific statistical data pretreatment was applied. Based on the results, the statistical model built for comparing the hashish seizures leads to low error rates. Therefore, the implemented methodology is suitable for the chemical profiling of hashish seizures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A gas chromatography-mass spectrometry (GC-MS) method is presented which allows the simultaneous determination of the plasma concentrations of the levo-alpha-acetylmethadol (LAAM) and of its active metabolites (NorLAAM and DiNorLAAM), after derivatization with the reagent trifluoroacetic anhydride (TFAA). No interferences from endogenous compounds were observed following the extraction of plasma samples from 11 different human subjects. The standard curves were linear over a working range of 5-200ng/ml for the three compounds. Recoveries measured at three concentrations ranged from 47 to 67% for LAAM, from 50 to 69% for NorLAAM and from 28 to 50% for DiNorLAAM. Intra- and interday coefficients of variation determined at three concentrations ranged from 5 to 13% for LAAM, from 3 to 9% for NorLAAM and from 5 to 13% for DiNorLAAM. The limits of quantitation of the method were found to be 4ng/ml for the three compounds. No interference was noted from methadone. This sensitive and specific analytical method could be useful for assessing the in vivo relationship between LAAM's blood levels, clinical efficacy and/or cardiotoxicity

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study presents a classification criteria for two-class Cannabis seedlings. As the cultivation of drug type cannabis is forbidden in Switzerland, law enforcement authorities regularly ask laboratories to determine cannabis plant's chemotype from seized material in order to ascertain that the plantation is legal or not. In this study, the classification analysis is based on data obtained from the relative proportion of three major leaf compounds measured by gas-chromatography interfaced with mass spectrometry (GC-MS). The aim is to discriminate between drug type (illegal) and fiber type (legal) cannabis at an early stage of the growth. A Bayesian procedure is proposed: a Bayes factor is computed and classification is performed on the basis of the decision maker specifications (i.e. prior probability distributions on cannabis type and consequences of classification measured by losses). Classification rates are computed with two statistical models and results are compared. Sensitivity analysis is then performed to analyze the robustness of classification criteria.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Rotenone is a botanical pesticide derived from extracts of Derris roots, which is traditionally used as piscicide, but also as an industrial insecticide for home gardens. Its mechanism of action is potent inhibition of mitochondrial respiratory chain by uncoupling oxidative phosphorylation by blocking electron transport at complex-I. Despite its classification as mild to moderately toxic to humans (estimated LD50, 300-500 mg/kg), there is a striking variety of acute toxicity of rotenone depending on the formulation (solvents). Human fatalities with rotenone-containing insecticides have been rarely reported, and a rapid deterioration within a few hours of the ingestion has been described previously in one case. Case report: A 49-year-old Tamil man with a history of asthma, ingested 250 mL of an insecticide containing 1.24% of rotenone (3.125 g, 52.1-62.5 mg/kg) in a suicide attempt at home. The product was not labeled as toxic. One hour later, he vomited repeatedly and emergency services were alerted. He was found unconscious with irregular respiration and was intubated. On arrival at the emergency department, he was comatose (GCS 3) with fixed and dilated pupils, and absent corneal reflexes. Physical examination revealed hemodynamic instability with hypotension (55/30 mmHg) and bradycardia (52 bpm). Significant laboratory findings were lactic acidosis (pH 6.97, lactate 17 mmol/L) and hypokalemia (2 mmol/L). Cranial computed tomography (CT) showed early cerebral edema. A single dose of activated charcoal was given. Intravenous hydration, ephedrine, repeated boli of dobutamine, and a perfusor with 90 micrograms/h norepinephine stabilized blood pressure temporarily. Atropine had a minimal effect on heart rate (58 bpm). Intravenous lipid emulsion was considered (log Pow 4.1), but there was a rapid deterioration with refractory hypotension and acute circulatory failure. The patient died 5h after ingestion of the insecticide. No autopsy was performed. Quantitative analysis of serum performed by high-resolution/accurate mass-mass spectrometry and liquid chromatography (LC-HR/AM-MS): 560 ng/mL rotenone. Other substances were excluded by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS/MS). Conclusion: The clinical course was characterized by early severe symptoms and a rapidly fatal evolution, compatible with inhibition of mitochondrial energy supply. Although rotenone is classified as mild to moderately toxic, physicians must be aware that suicidal ingestion of emulsified concentrates may be rapidly fatal. (n=3): stridor, cyanosis, cough (one each). Local swelling after chewing or swallowing soap developed at the earliest after 20 minutes and persisted beyond 24 hours in some cases. Treatment with antihistamines and/or steroids relieved the symptoms in 9 cases. Conclusion: Bar soap ingestion by seniors carries a risk of severe local reactions. Half the patients developed symptoms, predominantly swellings of tongue and/or lips (38%). Cognitive impairment, particularly in the cases of dementia (37%), may increase the risk of unintentional ingestion. Chewing and intraoral retention of soap leads to prolonged contact with the mucosal membranes. Age-associated physiological changes of oral mucosa probably promote the irritant effects of the surfactants. Medical treatment with antihistamines and corticosteroids usually leads to rapid decline of symptoms. Without treatment, there may be a risk of airway obstruction.