84 resultados para Radionuclide


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Myocardial infarction is rare in children, if it occurs, findings are almost similar to adults. In Ouchenne muscular dystrophy (OMO), ST segment displacement associated with typical chest pain can occur. We report the case of a young boy with OMO presenting symptoms suggestive of myocardial ischemia. Case report: 7 year old boy, diagnosed with OMO, eoming to the emergency department with complaints of acute chest pain, dyspnoea and anxiety the night before. Clinical examination was not remarkable, with exception of findings of the OMO. ECG showed important ST-segment elevation in right precordial leads. Major increase in troponin 1 42.33 mcg/(normal, <0.04 mcg/I) was found. Echocardiography revealed slight yskinesia of postero-septal wall without decrease in ventricular function. As acute pain had happened more han 12 hours before referral and as the child was asymptomatic, he received anti-platelets therapy. The serum level of troponin 1 declined and the ECG normalised in a few days. Cardiac catheterization did not show any coronary anomaly or eardiac dysfunction. Cardiac biopsy revealed myocardial cell damaged compatible with OMO cardiomyopathy. Tc99m myocardial single-photon emission computed tomography (SPECT) did not show any radionuclide uptake defect. Conclusions: ln this particular context of children with OMO, the classical signs of myocardial ischemia could be misleading, standard investigation failed to demonstrate the cause of chest pain and inerease of troponin l, there was also no evidence of myocarditis. Role of late enhancement (LE) signal in eontrast-enhanced MRI in the understanding of the occurring process has to be evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies in adults have shown that late gadolinium enhanced cardiac magnetic resonance is a safe and noninvasive diagnostic tool which allows one to differentiate myocardial infarction from myocarditis. We believe that it may also be highly useful in the paediatric population for the same purpose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful detection of inflammatory lesions by planar scintigraphy and SPECT after injection of iodine-123 labelled monoclonal antibodies directed against human granulocytes (123I-Mabgc) is demonstrated. This new tracer has been compared with indium-111 labelled white blood cells (111In-WBC) in selected patients with proven infectious lesions. Scans were equally positive in all cases, but the methodical advantages of the new marker were obvious, namely, there is no need for cell separation and the images of inflammatory lesions were better defined. In addition, SPECT could be performed with 123I-Mabgc and allowed a better anatomic localization and a three-dimensional description of the lesions. No adverse reactions have been seen. It is concluded, therefore, that 123I-Mabgc is a promising agent for the detection of acute focal inflammatory lesions which may, with advantages, replace 111In-WBC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A radiolabeled monoclonal antibody (MAb) that has been shown to react specifically in vitro and ex vivo to human colorectal carcinoma and to inhibit growth of human carcinomas grafted in nude mice was administered to 52 colorectal carcinoma patients and 15 patients with other types of cancer. Of 63 colorectal carcinoma tumor sites studied, 34 showed significant accumulation of antibody by external photoscanning and tomoscintigraphy, whereas none of the 20 sites of other cancer types gave positive results. One-third of the patients received F(ab')2 fragments of the MAb, which gave a slightly higher percentage (61%) of positive results than did intact MAbs (51%). A few patients scheduled for tumor resection were given injections simultaneously of 131I-labeled MAb and 125I-labeled normal immunoglobulin G. Antibody concentration in resected tumors was 3.6 to 6.3 times higher than the average antibody concentration in adjacent normal tissues (1.5, 3.4, and 9.4 as compared with normal mucosa, serosa, and fat, respectively), and the specificity indices, calculated by differential radioactivity analysis, ranged from 2.1 to 5.1. The results show the potential value and limitations of this particular MAb for tumor detection by immunoscintigraphy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the response to F+0 renography and the relative and absolute individual kidney function in neonates and &lt; 6-mo-old infants before and after surgery for unilateral ureteropelvic junction obstruction (UJO). METHODS: The results obtained at diagnosis and after pyeloplasty for 9 children (8 boys, 1 girl; age range, 0.8-5.9 mo; mean age +/- SD, 2.4 +/- 1.5 mo) with proven unilateral UJO (i.e., affected kidney [AK]) and an unremarkable contralateral kidney (i.e., normal kidney [NK]) were evaluated and compared with a control group of 10 children (6 boys, 4 girls; age range, 0.8-2.8 mo; mean age, 1.5 +/- 0.7 mo) selected because of symmetric renal function, absence of vesicoureteral reflux or infection, and an initially dilated but not obstructed renal pelvis as proven by follow-up. Renography was performed for 20 min after injection of (123)I-hippuran (OIH) (0.5-1.0 MBq/kg) immediately followed by furosemide (1 mg/kg). The relative and absolute renal functions and the response to furosemide were measured on background-subtracted and depth-corrected renograms. The response to furosemide was quantified by an elimination index (EI), defined as the ratio of the 3- to 20-min activities: An EI &gt; or = 3 was considered definitively normal and an EI &lt; or = 1 definitively abnormal. If EI was equivocal (1 &lt; EI &lt; 3), the response to gravity-assisted drainage was used to differentiate AKs from NKs. Absolute separate renal function was measured by an accumulation index (AI), defined as the percentage of (123)I-OIH (%ID) extracted by the kidney 30-90 s after maximal cardiac activity. RESULTS: All AKs had definitively abnormal EIs at diagnosis (mean, 0.56 +/- 0.12) and were significantly lower than the EIs of the NKs (mean, 3.24 +/- 1.88) and of the 20 control kidneys (mean, 3.81 +/- 1.97; P &lt; 0.001). The EIs of the AKs significantly improved (mean, 2.81 +/- 0.64; P &lt; 0.05) after pyeloplasty. At diagnosis, the AIs of the AKs were significantly lower (mean, 6.31 +/- 2.33 %ID) than the AIs of the NKs (mean, 9.43 +/- 1.12 %ID) and of the control kidneys (mean, 9.05 +/- 1.17 %ID; P &lt; 0.05). The AIs of the AKs increased at follow-up (mean, 7.81 +/- 2.23 %ID) but remained lower than those of the NKs (mean, 10.75 +/- 1.35 %ID; P &lt; 0.05). CONCLUSION: In neonates and infants younger than 6 mo, (123)I-OIH renography with early furosemide injection (F+0) allowed us to reliably diagnose AKs and to determine if parenchymal function was normal or impaired and if it improved after surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monoclonal antibodies (MoAb) that react with the T-lymphocyte markers called cluster of differentiation CD5 and CD2 were labeled with iodine 131 (131I) and were injected intravenously in nude mice bearing solid subcutaneous xenografts derived from the human T-cell leukemia line Ichikawa. Both MoAb anti-CD5 and anti-CD2 yielded favorable mean tumor to whole-body ratios of 3.8 and 5.1, respectively. These ratios were further increased up to 10.0 for MoAb anti-CD5 and 15.5 for MoAb anti-CD2 by using their F(ab')2 fragments. The tumors could be imaged clearly by external scanning after injection of F(ab')2 fragments from both MoAb. F(ab')2 fragments from MoAb anti-CD2 and of a third MoAb recognizing the clonotypic determinant (Ti) of the antigen receptor expressed by the human T-cell line Jurkat were injected in mice bearing intrasplenic Jurkat xenografts. A selective localization of both fragments in tumor tissue was demonstrated with mean tumor to whole-body ratios of 7.5 and 4.1 for MoAb anti-CD2 and anti-Ti, respectively. These in vivo experimental results may provide useful information for the potential use of radiolabeled MoAb and fragments in the diagnosis and treatment of patients with T-cell lymphoma and different other forms of T-cell malignancies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The importance of the right ventricle as a determinant of clinical symptoms, exercise capacity, peri-operative survival and postoperative outcome has been underestimated for a long time. Right ventricular ejection fraction has been used as a measure of right ventricular function but has been found to be dependent on loading conditions, ventricular interaction as well as on myocardial structure. Altered left ventricular function in patients with valvular disease influences right ventricular performance mainly by changes in afterload but also by ventricular interaction. Right ventricular function and regional wall motion can be determined with right ventricular angiography, radionuclide ventriculography, two-dimensional echocardiography or magnetic resonance imaging. However, the complex structure of the right ventricle and its pronounced translational movements render quantification difficult. True regional wall motion analysis is, however, possible with myocardial tagging based on magnetic resonance techniques. With this technique a baso-apical shear motion of the right ventricle was observed which was enhanced in patients with aortic stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perfusion lung scan, whether associated with a ventilation lung scan or not, is frequently used in the diagnosis of pulmonary emboli. The characteristics of perfusion lung scan are reviewed. The added diagnostic value of standard chest X-ray and of ventilation scan is discussed, as well as its use in the intensive care unit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

F(ab')2-fragments of the anti-melanoma monoclonal antibody MeI-14 were labelled with 123I for external scanning and with 125I for tissue measurement of radioactivity and injected intravenously into patients scheduled for surgical resection of a glioma. The paired-label study was performed by injecting simultaneously 131I-labelled control (F(ab')2-fragments. The patients were scanned by computerised tomoscintigraphy. After surgery, the activities of 125I and 131I were counted in tumour and normal tissues. The results indicate that there was a low but definite uptake of the antibody in the tumour due to its specificity. The external detection was difficult because of accumulation of antibody fragments in the skull.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: In the radiopharmaceutical therapy approach to the fight against cancer, in particular when it comes to translating laboratory results to the clinical setting, modeling has served as an invaluable tool for guidance and for understanding the processes operating at the cellular level and how these relate to macroscopic observables. Tumor control probability (TCP) is the dosimetric end point quantity of choice which relates to experimental and clinical data: it requires knowledge of individual cellular absorbed doses since it depends on the assessment of the treatment's ability to kill each and every cell. Macroscopic tumors, seen in both clinical and experimental studies, contain too many cells to be modeled individually in Monte Carlo simulation; yet, in particular for low ratios of decays to cells, a cell-based model that does not smooth away statistical considerations associated with low activity is a necessity. The authors present here an adaptation of the simple sphere-based model from which cellular level dosimetry for macroscopic tumors and their end point quantities, such as TCP, may be extrapolated more reliably. METHODS: Ten homogenous spheres representing tumors of different sizes were constructed in GEANT4. The radionuclide 131I was randomly allowed to decay for each model size and for seven different ratios of number of decays to number of cells, N(r): 1000, 500, 200, 100, 50, 20, and 10 decays per cell. The deposited energy was collected in radial bins and divided by the bin mass to obtain the average bin absorbed dose. To simulate a cellular model, the number of cells present in each bin was calculated and an absorbed dose attributed to each cell equal to the bin average absorbed dose with a randomly determined adjustment based on a Gaussian probability distribution with a width equal to the statistical uncertainty consistent with the ratio of decays to cells, i.e., equal to Nr-1/2. From dose volume histograms the surviving fraction of cells, equivalent uniform dose (EUD), and TCP for the different scenarios were calculated. Comparably sized spherical models containing individual spherical cells (15 microm diameter) in hexagonal lattices were constructed, and Monte Carlo simulations were executed for all the same previous scenarios. The dosimetric quantities were calculated and compared to the adjusted simple sphere model results. The model was then applied to the Bortezomib-induced enzyme-targeted radiotherapy (BETR) strategy of targeting Epstein-Barr virus (EBV)-expressing cancers. RESULTS: The TCP values were comparable to within 2% between the adjusted simple sphere and full cellular models. Additionally, models were generated for a nonuniform distribution of activity, and results were compared between the adjusted spherical and cellular models with similar comparability. The TCP values from the experimental macroscopic tumor results were consistent with the experimental observations for BETR-treated 1 g EBV-expressing lymphoma tumors in mice. CONCLUSIONS: The adjusted spherical model presented here provides more accurate TCP values than simple spheres, on par with full cellular Monte Carlo simulations while maintaining the simplicity of the simple sphere model. This model provides a basis for complementing and understanding laboratory and clinical results pertaining to radiopharmaceutical therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current nuclear medicine techniques for the localization of inflammatory processes are based on injection of 111In labelled autologous granulocytes which need to be isolated and radiolabelled in vitro before reinjection. A new technique is presented here that obviates the need for cell isolation by the direct intravenous injection of a granulocyte specific 123I labelled monoclonal antibody. In this publication the basic parameters of the antibody granulocyte interaction are described. Antibody binding does not inhibit vital functions of the granulocytes, such as chemotaxis and superoxide generation. Scatchard analysis of binding data reveals an apparent affinity of the antibody for granulocytes of 6.8 X 10(9) l/mol and approximately 7.1 X 10(4) binding sites per cell. Due to the high specificity of the antibody, the only expected interference is from CEA producing tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD). METHODS: MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used. RESULTS: Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31). CONCLUSION: Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.