42 resultados para RF magnetron sputtering
Resumo:
A 46-year-old man underwent radiofrequency (RF) ablation of three liver metastases 7 months after undergoing right colectomy for a pT2N0Mx colon adenocarcinoma. Three months after the procedure, he developed hepatic abscesses related to a fistula between the distal ileum and segment V biliary branches.
Resumo:
RÉSUMÉ L'exercice est utilisé dans le traitement de la lombalgie depuis plus de cent ans. La recherche dans ce domaine a commencé au milieu du XXème siècle puis s'est développée exponentiellement jusqu'à nos jours. La première étude de cette thèse a eu pour but de passer en revue cette abondante littérature scientifique. Il en est ressorti que l'exercice est un moyen efficace de prévention primaire et secondaire de la lombalgie. En tant que modalité de traitement, l'exercice permet de diminuer l'incapacité et la douleur et d'améliorer la condition physique et le statut professionnel des patients lombalgiques subaigus et chroniques. Parmi les caractéristiques de l'exercice, la supervision est essentielle. Des investigations ultérieures sont nécessaires afin d'identifier des sous-groupes de patients répondant favorablement à d'autres caractéristiques de l'exercice. L'exercice est souvent utilisé dans l'optique de maintenir les résultats obtenus à la suite d'un traitement, bien que peu d'études s'y soient penchées. La deuxième partie de cette thèse a eu pour objectifs d'évaluer l'efficacité d'un programme d'exercice (PE) suivi par des patients lombalgiques chroniques ayant complété une restauration fonctionnelle multidisciplinaire (RFM), en comparaison avec le suivi classique (SC) consistant simplement à encourager les patients à adopter un quotidien aussi actif que possible par la suite. Les résultats ont montré que les améliorations obtenues au terme de RFM étaient maintenues par les deux groupes à un an de suivi. Bien qu'aucune différence n'ait été obtenue entre les deux groupes, seul le groupe PE améliorait significativement l'incapacité et l'endurance isométrique des muscles du tronc. Une analyse économique a ensuite été réalisée afin d'évaluer la rentabilité de PE. L'évaluation de la qualité de vie des patients au terme de RFM et à un an de suivi permettait d'estimer les années de vie ajustées par leur qualité (QALYs) gagnées par chaque groupe. Les coûts directs (visites chez le médecin, spécialiste, physio, autres) et indirects (jours d'absence au travail) étaient estimés avant RFM et à un an de suivi à l'aide d'un agenda. Aucune différence significative n'était obtenue entre les groupes. Une mince différence de QALYs en faveur de PE ne se traduisait néanmoins pas en bénéfices mesurables. La recherche future devrait s'attacher à identifier un ou des sous-groupe(s) de patients pour lesquels SC ne permet pas de maintenir à long terme les améliorations obtenues au terme de RFM, et pour lesquels l'efficacité thérapeutique et la rentabilité économique de PE pourraient être accrues. ABSTRACT Exercise is used to treat low back pain for over a hundred years. Research in this area began in the mid-twentieth century and then grew exponentially until nowadays. The first study of this thesis was aimed to review this abundant scientific literature. It showed that exercise is effective in the primary and secondary prevention of low back pain. As a modality of treatment, exercise can reduce disability and pain and improve physical fitness and professional status of patients with subacute and chronic low back pain. Among different exercise characteristics, supervision is essential. Further investigations are needed to identify subgroups of patients responding positively to other characteristics of exercise. Exercise is often used as a post-treatment modality in order to maintain results over time, although only a few studies addressed this issue directly. The purpose of the second part of this thesis was to evaluate the effectiveness of an exercise program (EP) for patients with chronic low back pain who completed a functional multidisciplinary rehabilitation (FMR), compared to the routine follow-up (RF) which simply consisted of encouraging patients to adopt an active daily life thereafter. The results showed that improvements obtained at the end of FMR were maintained by both groups at one year follow-up. Although no difference was obtained between both groups, only the EP group significantly improved disability and isometric endurance of trunk muscles. An economic analysis was then carried out to assess the cost-effectiveness of EP. Based on the evaluation of patients' quality of life after FMR and at one year follow-up, an estimation of adjusted life years for their quality (QALYs) gained by each group was done. Direct costs (physician, specialist, physiotherapist, other therapists visits) and indirect costs (days off work) were measured before FMR and at one year follow-up using a cost diary. No significant difference was obtained between both groups. A slight difference in QALYs in favour of EP did yet not translate into measurable benefits. Future research should focus on identifying subgroups of patients for which RF is insufficient to reach long-term improvements after FMR, and for which the therapeutic effectiveness and cost-effectiveness of EP could be increased.
Resumo:
BACKGROUND: There is little information regarding the determinants and trends of the prevalence of low cardiovascular risk factor (RF) profile in the general population. The aim of this study was to assess the prevalence and trends of low RF profile in the Swiss population according to different definitions. METHODS: Population-based cross-sectional studies conducted in 1984-1986 (N=3300), 1988-1989 (N=3331), 1992-1993 (N=3133) and 2003-2006 (N=6170) and restricted to age group 35-75 years. Seven different definitions of low RF profile were used to assess determinants, while two definitions were used to assess trends. RESULTS: Prevalence of low RF profile varied between 6.5% (95% confidence interval: 5.9-7.1) and 9.7% (9.0-10.5) depending on the definition used. This prevalence was higher than in other countries. Irrespective of the definition used, the prevalence of low RF profile was higher in women and in physically active participants, and decreased with increasing age or in the presence of a family history of cardiovascular disease. Using one definition, the prevalence of low RF profile increased from 3.8% (3.1-4.5) in 1984-1986 to 6.7% (6.1-7.3) in 2003-2006; using another definition, the results were 5.9% (5.1-6.8) and 9.7% (9.0-10.5), respectively. CONCLUSION: Switzerland is characterized by a high and increasing prevalence of low RF profile within the age group 35 to 75, irrespective of the criteria used. This high prevalence might partly explain the low and decreasing trend in cardiovascular mortality rates.
Resumo:
The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.
Resumo:
Evaluation of segmentation methods is a crucial aspect in image processing, especially in the medical imaging field, where small differences between segmented regions in the anatomy can be of paramount importance. Usually, segmentation evaluation is based on a measure that depends on the number of segmented voxels inside and outside of some reference regions that are called gold standards. Although some other measures have been also used, in this work we propose a set of new similarity measures, based on different features, such as the location and intensity values of the misclassified voxels, and the connectivity and the boundaries of the segmented data. Using the multidimensional information provided by these measures, we propose a new evaluation method whose results are visualized applying a Principal Component Analysis of the data, obtaining a simplified graphical method to compare different segmentation results. We have carried out an intensive study using several classic segmentation methods applied to a set of MRI simulated data of the brain with several noise and RF inhomogeneity levels, and also to real data, showing that the new measures proposed here and the results that we have obtained from the multidimensional evaluation, improve the robustness of the evaluation and provides better understanding about the difference between segmentation methods.
Resumo:
Purpose: to assess the prevalence and trends of low cardiovascular risk factor (RF) profile in the Swiss population according to different definitions. Methods: Population-based cross-sectional study of 6170 subjects (3241 women) aged 35-75 years living in Lausanne, Switzerland. Trends were assessed using data from the Swiss MONICA population surveys conducted in 1984-6 (N = 3300), 1988-9 (N = 3331) and 1992-3 (N = 3133) and restricted to the same age group. Seven different definitions of low RF profile were used. Results: prevalence of low RF profile varied between 6.5% (95% confidence interval: 5.9-7.1) and 9.7% (9.0-10.5) depending on the definition used (see fig. 1). The prevalence was inversely related to the number of criteria used and higher than in other countries. Irrespective of the definition used, the prevalence of low RF profile was higher in women and in physically active participants, and decreased with increasing age or in the presence of a family history of cardiovascular disease. The prevalence of low RF profile increased from 3.8% (3.1- 4.5) in 1984-6 to 6.7% (6.1-7.3) in 2003-6; using another definition, the results were 5.9% (5.1-6.8) and 9.7% (9.0-10.5), respectively (see fig. 2). Conclusion: the prevalence of low RF profile varies according to the criteria used; this prevalence is relatively high and increasing in the Swiss population, which might partly explain the low and decreasing trend in cardiovascular mortality rates.
Resumo:
PURPOSE: To compare the apparent diffusion coefficient (ADC) values of malignant liver lesions on diffusion-weighted MRI (DWI) before and after successful radiofrequency ablation (RF ablation). MATERIALS AND METHODS: Thirty-two patients with 43 malignant liver lesions (23/20: metastases/hepatocellular carcinomas (HCC)) underwent liver MRI (3.0T) before (<1month) and after RF ablation (at 1, 3 and 6months) using T2-, gadolinium-enhanced T1- and DWI-weighted MR sequences. Jointly, two radiologists prospectively measured ADCs for each lesion by means of two different regions of interest (ROIs), first including the whole lesion and secondly the area with the visibly most restricted diffusion (MRDA) on ADC map. Changes of ADCs were evaluated with ANOVA and Dunnett tests. RESULTS: Thirty-one patients were successfully treated, while one patient was excluded due to focal recurrence. In metastases (n=22), the ADC in the whole lesion and in MRDA showed an up-and-down evolution. In HCC (n=20), the evolution of ADC was more complex, but with significantly higher values (p=0.013) at 1 and 6months after RF ablation. CONCLUSION: The ADC values of malignant liver lesions successfully treated by RF ablation show a predictable evolution and may help radiologists to monitor tumor response after treatment.
Resumo:
The double spin-echo point resolved spectroscopy sequence (PRESS) is a widely used method and standard in clinical MR spectroscopy. Existence of important J-modulations at constant echo times, depending on the temporal delays between the rf-pulses, have been demonstrated recently for strongly coupled spin systems and were exploited for difference editing, removing singlets from the spectrum (strong-coupling PRESS, S-PRESS). A drawback of this method for in vivo applications is that large signal modulations needed for difference editing occur only at relatively long echo times. In this work we demonstrate that, by simply adding a third refocusing pulse (3S-PRESS), difference editing becomes possible at substantially shorter echo times while, as applied to citrate, more favorable lineshapes can be obtained. For the example of an AB system an analytical description of the MR signal, obtained with this triple refocusing sequence (3S-PRESS), is provided.
Resumo:
Myocardial tagging has shown to be a useful magnetic resonance modality for the assessment and quantification of local myocardial function. Many myocardial tagging techniques suffer from a rapid fading of the tags, restricting their application mainly to systolic phases of the cardiac cycle. However, left ventricular diastolic dysfunction has been increasingly appreciated as a major cause of heart failure. Subtraction based slice-following CSPAMM myocardial tagging has shown to overcome limitations such as fading of the tags. Remaining impediments to this technique, however, are extensive scanning times (approximately 10 min), the requirement of repeated breath-holds using a coached breathing pattern, and the enhanced sensitivity to artifacts related to poor patient compliance or inconsistent depths of end-expiratory breath-holds. We therefore propose a combination of slice-following CSPAMM myocardial tagging with a segmented EPI imaging sequence. Together with an optimized RF excitation scheme, this enables to acquire as many as 20 systolic and diastolic grid-tagged images per cardiac cycle with a high tagging contrast during a short period of sustained respiration.
Resumo:
Purpose: To evaluate the short- and mid-term evolutions of the apparent diffusion coefficient of lesions treated with RF, in order to determine if the ADC can be used as a marker of tumour response. Methods and Materials: Twenty patients were treated for a liver malignancy with RF and were examined on a 1.5 T/3.0 T machine with T2, gadolinium-enhanced T1 and diffusion sequences: before treatment (< 1 month), just after treatment (< 1 month) and midterm (3-6 months). The ADC was measured in the whole lesion and in the area with the most restricted diffusion (MRDA). The ROI size was also measured on the diffusion map. The Pearson/ANOVA tests were used. Results: All patients were successfully treated with complete disappearance of CE. The lesional size on T2 showed a negative evolution in time (p < 0.002). The ADC in the whole lesion showed a bell-shaped evolution (increasing just after RF, then decreasing, p = 0.02). The ROI size on the diffusion map followed a similar course (p = 0.01). For the MRDA, such evolutions were also found, but they were not significant. There was a negative correlation between CE and the ADC (p < 0.02) and between the lesional size on T2 and ADC (p = 0.03) in the whole lesion. There were also positive correlations between the ROI size and ADC (p = 0.0008) and between CE and the size on T2 (p = 0.0002). The ADC in MRDA showed some non-significant correlations with other variables. Conclusion: The lesions successfully treated with RF have a clear and predictable evolution in terms of T2 size, CE and ADC.
Resumo:
Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.
Resumo:
PURPOSE: Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS: Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. RESULTS: The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. CONCLUSION: Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
Background: There is little information regarding the determinants and trends of the prevalence of low cardiovascular risk factor (RF) profile in the general population. The aim of this study was to assess the prevalence and trends of low RF profile in the Swiss population according to different definitions. Methods: Population-based cross-sectional studies conducted in 1984-6 (N=3300), 1988-9 (N=3331), 1992-3 (N=3133) and 2003-6 (N=6170) and restricted to age group 35-75 years. Seven different definitions of low RF profile were used to assess determinants, while two definitions were used to assess trends. Results: Prevalence of low RF profile varied between 6.5% (95% confidence interval: 5.9-7.1) and 9.7% (9.0-10.5) depending on the definition used. This prevalence was higher than in other countries. Irrespective of the definition used, the prevalence of low RF profile was higher in women and in physically active participants, and decreased with increasing age or in the presence of a family history of cardiovascular disease. Using one definition, the prevalence of low RF profile increased from 3.8% (3.1-4.5) in 1984-6 to 6.7% (6.1-7.3) in 2003-6; using another definition, the results were 5.9% (5.1-6.8) and 9.7% (9.0-10.5), respectively. Conclusion: Switzerland is characterized by a high and increasing prevalence of low RF profile within the age group 35 to 75, irrespective of the criteria used. This high prevalence might partly e
Resumo:
In this work we present a first feasibility study of the ClearPEM technology for simultaneous PET-MR imaging. The mutual electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing the response behavior of the ClearPEM detectors and front-end electronics to pulsed RF power and switched magnetic field gradients; and by analyzing the MR system performance degradation from noise pickup into the RF receiver chain, and from magnetic susceptibility artifacts caused by PET front-end materials.
Resumo:
At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.