49 resultados para Quantum Coherence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no doubt about the necessity of protecting digital communication: Citizens are entrusting their most confidential and sensitive data to digital processing and communication, and so do governments, corporations, and armed forces. Digital communication networks are also an integral component of many critical infrastructures we are seriously depending on in our daily lives. Transportation services, financial services, energy grids, food production and distribution networks are only a few examples of such infrastructures. Protecting digital communication means protecting confidentiality and integrity by encrypting and authenticating its contents. But most digital communication is not secure today. Nevertheless, some of the most ardent problems could be solved with a more stringent use of current cryptographic technologies. Quite surprisingly, a new cryptographic primitive emerges from the ap-plication of quantum mechanics to information and communication theory: Quantum Key Distribution. QKD is difficult to understand, it is complex, technically challenging, and costly-yet it enables two parties to share a secret key for use in any subsequent cryptographic task, with an unprecedented long-term security. It is disputed, whether technically and economically fea-sible applications can be found. Our vision is, that despite technical difficulty and inherent limitations, Quantum Key Distribution has a great potential and fits well with other cryptographic primitives, enabling the development of highly secure new applications and services. In this thesis we take a structured approach to analyze the practical applicability of QKD and display several use cases of different complexity, for which it can be a technology of choice, either because of its unique forward security features, or because of its practicability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The psychological transmission of the noxious effects of a major trauma from one generation to the next remains unclear. The present study aims to identify possible mechanisms explaining this transmission among families of Holocaust Survivors (HS). We hypothesized that the high level of depressive and anxiety disorders (DAD) among HS impairs family systems, which results in damaging coping strategies of their children (CHS) yielding a higher level of DAD. METHODS: 49 CHS completed the Resilience Scale for Adults, the Hopkins Symptom Check List-25, the 13-Item Sense of Coherence (SOC) scale, and the Family Adaptability and Cohesion Scale. We test a mediation model with Family types as the predictor; coping strategies (i.e. Resilience or SOC) as the mediator; and DAD as the outcome variable. RESULTS: Results confirm that the CHS׳ family types are more often damaged than in general population. Moreover, growing in a damaged family seems to impede development of coping strategies and, therefore, enhances the occurrence of DAD. LIMITATIONS: The present investigation is correlational and should be confirmed by other prospective investigations. CONCLUSIONS: At a theoretical level we propose a mechanism of transmission of the noxious effects of a major trauma from one generation to the next through family structure and coping strategies. At a clinical level, our results suggest to investigate the occurrence of trauma among parents of patients consulting for DAD and to reinforce their coping strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lot of research in cognition and decision making suffers from a lack of formalism. The quantum probability program could help to improve this situation, but we wonder whether it would provide even more added value if its presumed focus on outcome models were complemented by process models that are, ideally, informed by ecological analyses and integrated into cognitive architectures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé La cryptographie classique est basée sur des concepts mathématiques dont la sécurité dépend de la complexité du calcul de l'inverse des fonctions. Ce type de chiffrement est à la merci de la puissance de calcul des ordinateurs ainsi que la découverte d'algorithme permettant le calcul des inverses de certaines fonctions mathématiques en un temps «raisonnable ». L'utilisation d'un procédé dont la sécurité est scientifiquement prouvée s'avère donc indispensable surtout les échanges critiques (systèmes bancaires, gouvernements,...). La cryptographie quantique répond à ce besoin. En effet, sa sécurité est basée sur des lois de la physique quantique lui assurant un fonctionnement inconditionnellement sécurisé. Toutefois, l'application et l'intégration de la cryptographie quantique sont un souci pour les développeurs de ce type de solution. Cette thèse justifie la nécessité de l'utilisation de la cryptographie quantique. Elle montre que le coût engendré par le déploiement de cette solution est justifié. Elle propose un mécanisme simple et réalisable d'intégration de la cryptographie quantique dans des protocoles de communication largement utilisés comme les protocoles PPP, IPSec et le protocole 802.1li. Des scénarios d'application illustrent la faisabilité de ces solutions. Une méthodologie d'évaluation, selon les critères communs, des solutions basées sur la cryptographie quantique est également proposée dans ce document. Abstract Classical cryptography is based on mathematical functions. The robustness of a cryptosystem essentially depends on the difficulty of computing the inverse of its one-way function. There is no mathematical proof that establishes whether it is impossible to find the inverse of a given one-way function. Therefore, it is mandatory to use a cryptosystem whose security is scientifically proven (especially for banking, governments, etc.). On the other hand, the security of quantum cryptography can be formally demonstrated. In fact, its security is based on the laws of physics that assure the unconditional security. How is it possible to use and integrate quantum cryptography into existing solutions? This thesis proposes a method to integrate quantum cryptography into existing communication protocols like PPP, IPSec and the 802.l1i protocol. It sketches out some possible scenarios in order to prove the feasibility and to estimate the cost of such scenarios. Directives and checkpoints are given to help in certifying quantum cryptography solutions according to Common Criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:To determine whether the need for retreatment after an initial loading phase of 3 monthly intravitreal injections of ranibizumab shows an intra-individual regular rhythm and to what degree it varies between different patients.SETTING:Prospective mono-centre cohort study.METHODS:Prospective study with 42 patients with exudative age-related macular degeneration (AMD), treatment na?ve, giving informed consent. Loading dose of 3 monthly doses of ranibizumab (0,5mg), followed by a 12 months pro re nata (PRN) regimen according to early exudative signs on spectral domain optical coherence tomography (HD-OCT Cirrus Zeiss?, cube 512x126). The follow-up visits were intensified (week 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, 24, etc after each injection) in order to detect exudative recurrences early, and injection followed within 3 days in cases of subretinal fluid, or intraretinal cysts, or central thickness increase of >50?m. Intervals were calculated between injections and the following recurrence was calculated for the 12 month follow-up with PRN treatment. Variability was expressed as standard deviation (SD). RESULTS Visual acuity (VA) improved from a mean ETDRS letter score of 61.6 (SD 10.8) at baseline to 68.0 (SD 10.2, +6.4 letters) at month 3 and increased further to 74.7 (SD 9.0, +13.1 letters from baseline) at month 12. The 15 patients who have completed the study by October 2010 showed maintenance of the VA improvement. Retinal thickness of the central foveal subfield improved from a mean value of 366?m(baseline) to 253?m(month 3), well maintained thereafter. Mean number of injections was 8.8 (SD 3.5) per 12 months of follow-up (after 3 loading doses), ranging from 0 to 12, with mean individual treatment-recurrence intervals ranging from 28 to >365 days (mean 58 days). Intraindividual variability of treatment-recurrence intervals, measured as SD of the individual intervals, was 7.1days as a mean value(range 1.7 ? 22.6 days) for the 33 patients with more than 1 injection during follow-up. SD was higher for longer intervals of an individual patient. It ranged within 20% of the mean intra-individual interval for 30 patients(91%) and within 15% for 21 patients(64%). The first interval was within 1 week of the mean intra-individual interval in 64% of patients and within 2 weeks in 89% of patients.CONCLUSIONS:The majority of AMD patients showed a relatively stable rhythm for PRN injections of intravitreal ranibizumab after initial loading phase, associated with excellent functional and anatomical results. The initial interval between last loading dose and first recurrence may have a predictive value for further need of treatment, therefore potentially facilitating follow-up and patient care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orientation: Research that considers the effects of individual characteristics and job characteristics jointly in burnout is necessary, especially when one considers the possibility of curvilinear relationships between job characteristics and burnout. Research purpose: This study examines the contribution of sense of coherence (SOC) and job characteristics to predicting burnout by considering direct and moderating effects. Motivation for this study: Understanding the relationships of individual and job characteristics with burnout is necessary for preventing burnout. It also informs the design of interventions. Research design, approach and method: The participants were 632 working adults (57% female) in South Africa. The measures included the Job Content Questionnaire, the Sense of Coherence Questionnaire and the Maslach Burnout Inventory. The authors analysed the data using hierarchical multiple regression with the enter method. Main findings: Job characteristics and SOC show the expected direct effects on burnout. SOC has a direct negative effect on burnout. Job demands and supervisor social support show nonlinear relationships with burnout. SOC moderates the effect of demands on burnout and has a protective function so that the demands-burnout relationship differs for those with high and low SOC. Practical/managerial implications: The types of effects, the shape of the stressor-strain relationship and the different contributions of individual and job characteristics have implications for designing interventions. Contribution/value add: SOC functions differently when combined with demands, control and support. These different effects suggest that it is not merely the presence or absence of a job characteristic that is important for well-being outcomes but how people respond to its presence or absence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of quantum dots (QDs) in the area of fingermark detection is currently receiving a lot of attention in the forensic literature. Most of the research efforts have been devoted to cadmium telluride (CdTe) quantum dots often applied as powders to the surfaces of interests. Both the use of cadmium and the nano size of these particles raise important issues in terms of health and safety. This paper proposes to replace CdTe QDs by zinc sulphide QDs doped with copper (ZnS:Cu) to address these issues. Zinc sulphide-copper doped QDs were successfully synthesized, characterized in terms of size and optical properties and optimized to be applied for the detection of impressions left in blood, where CdTe QDs proved to be efficient. Effectiveness of detection was assessed in comparison with CdTe QDs and Acid Yellow 7 (AY7, an effective blood reagent), using two series of depletive blood fingermarks from four donors prepared on four non-porous substrates, i.e. glass, transparent polypropylene, black polyethylene and aluminium foil. The marks were cut in half and processed separately with both reagents, leading to two comparison series (ZnS:Cu vs. CdTe, and ZnS:Cu vs. AY7). ZnS:Cu proved to be better than AY7 and at least as efficient as CdTe on most substrates. Consequently, copper-doped ZnS QDs constitute a valid substitute for cadmium-based QDs to detect blood marks on non-porous substrates and offer a safer alternative for routine use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this communication we introduce a low or reduced coherence interferometry technique that can be used to retrieve surface topology on samples with high roughness. Moreover, we will show that the approach enables surface topology measurement also at the interface of so-called turbid media, where multiple scattering inside tissues can be a major issue, preventing accurate measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.