67 resultados para Quality management in hospitals
Resumo:
The authors present 10 grids which are widely used in Health Sciences for the assessment of quality in research. They proceed through a comparative thematic analysis of these grids and show which points of view are preferred. They insist on the issues that differentiate these grids from each other and suggest the analysis of their differences by distinguishing the theoretical perspectives that underpin each one of these grids. Whilst the authors of the assessment grids rarely refer to the implicit theoretical backgrounds that guide their work, findings show that these grids convey varied epistemologies and research models. This gap renders the comparison of quality assessment in qualitative research a very difficult task, unless we shift our focus on the relationship between the grids, their theoretical backgrounds and their specific research subjects.
Resumo:
In higher plants such as Arabidopsis thaliana, omega-3 trienoic fatty acids (TFAs), represented mainly by alpha-linolenic acid, serve as precursors of jasmonic acid (JA), a potent lipid signal molecule essential for defense. The JA-independent roles of TFAs were investigated by comparing the TFA- and JA-deficient fatty acid desaturase triple mutant (fad3-2 fad7-2 fad8 (fad3 fad7 fad8)) with the aos (allene oxide synthase) mutant that contains TFAs but is JA-deficient. When challenged with the fungus Botrytis, resistance of the fad3 fad7 fad8 mutant was reduced when compared with the aos mutant, suggesting that TFAs play a role in cell survival independently of being the precursors of JA. An independent genetic approach using the lesion mimic mutant accelerated cell death2 (acd2-2) confirmed the importance of TFAs in containing lesion spread, which was increased in the lines in which the fad3 fad7 fad8 and acd2-2 mutations were combined when compared with the aos acd2-2 lines. Malondialdehyde, found to result from oxidative TFA fragmentation during lesion formation, was measured by gas chromatography-mass spectrometry. Its levels correlated with the survival of the tissue. Furthermore, plants lacking TFAs overproduced salicylic acid (SA), hydrogen peroxide, and transcripts encoding several SA-regulated and SA biosynthetic proteins. The data suggest a physiological role for TFAs as sinks for reactive oxygen species.
Resumo:
Although rare, popliteal artery aneurysms are the most common peripheral aneurysms and are frequently associated with abdominal aorta aneurysms. They are often bilateral. One third of patients are asymptomatic at diagnosis, with an insidious evolution. Symptomatic patients may present with symptoms of either acute ischemia or chronic ischemia, or rarely compression or rupture. Surgical exclusion of aneurysm followed by venous bypass remains the treatment of choice. Endovascular treatment is an attractive alternative currently reserved for patients at high risk, with good anatomical criteria. Elective treatment before symptoms onset is preferable given the best results in terms of patency and complications. A conservative approach is allowed for small aneurysms without major embolic risk provided careful monitoring by ultrasound.
Resumo:
Introduction: Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. Methods: During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Results: Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis nor vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis and vertebral fracture (clinical osteoporosis). Conclusion: In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either by changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often used in most of the centers.
Resumo:
Vertebral fracture is one of the major osteoporotic fractures which are unfortunately very often undetected. In addition, it is well known that prevalent vertebral fracture increases dramatically the risk of future additional fracture. Instant Vertebral Assessment (IVA) has been introduced in DXA device couple years ago to ease the detection of such fracture when routine DXA are performed. To correctly use such tool, ISCD provided clinical recommendation on when and how to use it. The aim of our study was to evaluate the ISCD guidelines in clinical routine patients and see how often it may change of patient management. During two months (March and April 2010), a medical questionnaire was systematically given to our clinical routine patient to check the validity of ISCD IVA recommendations in our population. In addition, all women had BMD measurement at AP spine, Femur and 1/3 radius using a Discovery A System (Hologic, Waltham, USA). When appropriate, IVA measurement had been performed on the same DXA system and had been centrally evaluated by two trained Doctors for fracture status according to the semi-quantitative method of Genant. The reading had been performed when possible between L5 and T4. Out of 210 women seen in the consultation, 109 (52%) of them (mean age 68.2±11.5 years) fulfilled the necessary criteria to have an IVA measurement. Out of these 109 women, 43 (incidence 39.4%) had osteoporosis at one of the three skeletal sites and 31 (incidence 28.4%) had at least one vertebral fracture. 14.7% of women had both osteoporosis and at least one vertebral fracture classifying them as "severe osteoporosis" while 46.8% did not have osteoporosis not vertebral fracture. 24.8% of the women had osteoporosis but no vertebral fracture while 13.8% of women did have osteoporosis but vertebral fracture (Clinical osteoporosis). In conclusion, in 52% of our patients, IVA was needed according to ISCD criteria. In half of them the IVA test influenced of patient management either my changing the type of treatment of simply by classifying patient as "clinical osteoporosis". IVA appears to be an important tool in clinical routine but unfortunately is not yet very often use in most of the centers.
Resumo:
Urinary incontinence in women is a largely under-evaluated problem that affects nearly one out of two adult women. Even thouh its physiopathology is complex and its etiologies are multiple (and often intricate), urodynamic investigations are not considered necessary before starting a conservative therapy, which can be initiated by the primary care physician. Conservative management is based upon lifestyle modifications, specialized physiotherapy, and in certain cases medication. In the case of insufficient response after three months, the patient should be recommended to a specialist who can evaluate the need for a surgical procedure.
Resumo:
Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).
Resumo:
Complex multimorbid patients are now more common in ambulatory care and the management of their medication more frequently needs interprofessional collaboration. This qualitative study explored health professional's main challenges when introducing, preparing and sharing the use of a pill box for a patient. Another objective of this study was to explore options for improving care in these situations.
Resumo:
Background: Despite the increasing incidences of the publication of assessment frameworks intending to establish the "standards" of the quality of qualitative research, the research conducted using such empirical methods are still facing difficulties in being published or recognised by funding agencies. Methods: We conducted a thematic content analysis of eight frameworks from psychology/psychiatry and general medicine. The frameworks and their criteria are then compared against each other. Findings: The results illustrated the difficulties in reaching consensus on the definition of quality criteria. This showed the differences between the frameworks from the point of views of the underlying epistemology and the criteria suggested. Discussion: The aforementioned differences reflect the diversity of paradigms implicitly referred to by the authors of the frameworks, although rarely explicitly mentioned in text. We conclude that the increase in qualitative research and publications has failed to overcome the difficulties in establishing shared criteria and the great heterogeneity of concepts raises methodological and epistemological problems.
Resumo:
Medication nonadherence is common and its determinants are diverse. Adherence is influenced by many parameters, such as patient's self-efficacy, knowledge of health risk, outcome expectations, benefits of change, and barriers and facilitators. The sociocognitive theory helps professionals to structure their approach and to support patients in managing their treatment. Professionals need skills and time, and benefit from coordination in care, in particular between physicians and pharmacists. This article presents the key elements of a medication adherence program as well as tools and some useful questions.
Resumo:
Introduction Vertebral fracture is one of the major osteoporoticfractures which are unfortunately very often undetected. In addition,it is well known that prevalent vertebral fracture increases dramaticallythe risk of future additional fracture. Instant Vertebral Assessment(IVA) has been introduced in DXA device a couple of years ago toease the detection of such fracture when routine DXA are performed.To correctly use such tool, ISCD provided clinical recommendationon when and how to use it. The aim of our study was to evaluate theISCD guidelines in clinical routine patients and see how often itmay change of patient management.Methods During two months (March and April 2010), a medicalquestionnaire was systematically given to our clinical routine patientto check the validity of ISCD IVA recommendations in our population.In addition, all women had BMD measurement at AP spine,femur and 1/3 radius using a Discovery A System (Hologic, Waltham,USA). When appropriate, IVA measurement had been performedon the same DXA system and had been centrally evaluated by twotrained doctors for fracture status according to the semi-quantitativemethod of Genant. The reading had been performed when possiblebetween L5 and T4.Results Out of 210 women seen in the consultation, 109 (52 %)of them (mean age 68.2 ± 11.5 years) fulfilled the necessary criteriato have an IVA measurement. Out of these 109 women, 43 (incidence39.4 %) had osteoporosis at one of the three skeletal sitesand 31 (incidence 28.4 %) had at least one vertebral fracture. 14.7 %of women had both osteoporosis and at least one vertebral fractureclassifying them as "severe osteoporosis" while 46.8 % did not haveosteoporosis and no vertebral fracture. 24.8 % of the women hadosteoporosis but no vertebral fracture while 13.8 % of women didhave osteoporosis but vertebral fracture (clinical osteoporosis).Conclusions In 52 % of our patients, IVA was needed accordingto ISCD criteria. In half of them the IVA test influenced of patientmanagement either may changing the type of treatment of simplyby classifying patient as "clinical osteoporosis". IVA appears to bean important tool in clinical routine but unfortunately is not yetvery often use in most of the centers.
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
Purpose: To set local dose reference levels (DRL) that allow radiologists to control stochastic and deterministic effects. Methods and materials: Dose indicators for cerebral angiographies and hepatic embolizations were collected during 4 months and analyzed in our hospital. The data were compared when an image amplifier was used instead of a flat panel detector. The Mann and Whitney test was used. Results: For the 40 cerebral angiographies performed the DRL for DAP, fluoroscopy time and number of images were respectively: 166 Gy.cm2, 19 min, 600. The maximum DAP was 490 Gy.cm2 (fluoroscopy time: 84 min). No significant difference for fluoroscopy time and DAP for image amplifier and flat panel detector (p = 0.88) was observed. The number of images was larger for flat panel detector (p = 0.004). The values obtained were slightly over the present proposed DRL: 150 Gy.cm2, 15 min, 400. Concerning the 13 hepatic embolizations the DRL for DAP fluoroscopy time and number of images were: 315 Gy.cm2, 25 min, 370. The maximum DAP delivered was 845 Gy.cm2 (fluoroscopy time of 48 min). No significant difference between image amplifier and flat panel detector was observed (p = 0.005). The values obtained were also slightly over the present proposed DRL: 300 Gy.cm2, 20 min, 200. Conclusion: These results show that the introduction of flat panel detector did not lead to an increase in patient dose. A DRL concerning the cumulative dose (that allow to control the deterministic effect) should be introduced to allow radiologists to have full control on the risks associated with ionizing radiations. Results of this on going study will be presented.